Spelling suggestions: "subject:"construtivos"" "subject:"reconstrutiva""
31 |
Avaliação pré e pós-operatória, através de ressonância magnética cardiovascular, de pacientes com insuficiência da valva mitral submetidos à plástica mitral pela técnica do duplo teflon / Preoperative and postoperative evaluation, by cardiovascular magnetic resonance, of patients with mitral valve insufficiency submitted to mitral valve repair using the double teflon techniqueAbdouni, Ahmad Ali 21 January 2019 (has links)
Introdução: A plástica valvar mitral é o tratamento de escolha no tratamento da insuficiência mitral de etiologia degenerativa. Estudos recentes têm demonstrado que a utilização de anéis protéticos na plástica mitral altera a dinâmica do anel mitral e do fluxo intraventricular, podendo levar a disfunção ventricular esquerda. Entretanto, a literatura é escassa em relação à morfologia e à dinâmica do anel mitral após a plástica mitral sem a utilização de anéis protéticos, e a ressonância magnética cardiovascular (RMC) é uma ferramenta que pode ser utilizada na avaliação do anel mitral e do remodelamento do átrio e do ventrículo esquerdo. Objetivo: Avaliar as alterações morfofuncionais, a dinâmica do anel mitral e o remodelamento do átrio e ventrículo esquerdo, por meio da RMC, em indivíduos portadores de insuficiência mitral de etiologia degenerativa, submetidos ao tratamento cirúrgico da valva mitral com a técnica do \"Duplo Teflon\". Métodos: No período de julho de 2014 a agosto de 2016, foram selecionados 36 pacientes consecutivos, com insuficiência mitral de etiologia degenerativa e prolapso da cúspide posterior. Três pacientes foram submetidos à troca valvar mitral e quatro não realizaram a RMC, de modo que 29 pacientes foram incluídos no protocolo e fizeram o seguimento proposto. Destes, 17 pacientes eram do sexo masculino (58,6%) e 12 do sexo feminino (41,4%), com idade média de 63,3 anos. Em relação à classe funcional (CF - NYHA), um paciente encontrava-se em CF I (3,4%), 5 pacientes em CF II (17,3%), 19 pacientes em CF III (65,5%) e 4 pacientes em CF IV (13,8%) no período pré-operatório. Os pacientes realizaram o exame de RMC no período pré-operatório, pós-operatório imediato (até 30 dias), 6 meses, um ano e dois anos após a cirurgia, utilizando um protocolo específico para avaliação da valva mitral. Foram obtidas as medidas da circunferência, dos diâmetros e da área do anel mitral em diferentes fases do ciclo cardíaco (diástole, sístole inicial, sístole média e sístole final). Foi analisado o remodelamento cardíaco, sendo utilizados como parâmetros as dimensões, volumes e fração de ejeção do átrio esquerdo e do ventrículo esquerdo, sendo os volumes indexados pela superfície corpórea. Utilizamos o teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante P < 0,05. Resultados: Houve um óbito hospitalar (3,4%). Com dois anos de seguimento, houve significativa melhora da classe funcional (CF), com 18 pacientes em CF I (75%) e 6 em CF II (25%). Após dois anos, 18 pacientes apresentam insuficiência mitral discreta ou ausente (75%) e dois pacientes (8,3%) apresentam insuficiência mitral importante, um deles relacionado ao implante de marcapasso no pós-operatório tardio. Observamos uma redução significativa em todas as medidas da valva mitral. A média da circunferência sistólica do anel mitral foi reduzida de 13,28 ± 1,95 para 11,5 ± 1,59 cm e a circunferência diastólica foi reduzida de 12,51 ± 2,01 para 10,66 ± 2,09 cm no período pós-operatório imediato, medidas que se mantiveram estáveis após 2 anos (P < 0,001). A média da área máxima do anel mitral no pré-operatório, pós-operatório imediato, 6 meses, 1 ano e 2 anos foi 14,34 ± 4,03 cm, 10,72 ± 2,81 cm, 10,92 ± 3,03 cm, 10,98 ± 3,45 cm, 10,45 ± 3,17 cm, respectivamente. A média da área mínima do anel mitral no pré-operatório, pós-operatório imediato, 6 meses, 1 ano e 2 anos foi de 12,53 ± 3,68 cm2, 9,60 ± 2,44 cm2, 9,66 ± 2,9 cm2, 9,60 ± 3,73 cm2 , 9,23 ± 2,84 cm2, respectivamente. Houve uma redução significativa desses parâmetros no seguimento de dois anos (p < 0,001), e essa redução foi maior no diâmetro ântero-posterior do que no diâmetro médio-lateral. A contração ou variação da área valvar mitral durante o ciclo cardíaco foi de 23,31 ± 9,04%, 19,63 ± 7,01%, 23,75 ± 8,09%, 25,75 ± 11,27%, 22,66 ± 9,77% respectivamente no pré-operatório, pós-operatório imediato, 6 meses, 1 ano e 2 anos, sem diferença estatística (p = 0,572), o que significa que a contratilidade do anel foi preservada após a cirurgia. Observamos redução dos volumes ventriculares e atriais esquerdos no seguimento, sendo mais significativa a redução do índice do volume diastólico final do ventrículo esquerdo. Conclusão: Observamos uma redução significativa do anel mitral após a cirurgia, em todas as medidas obtidas, com estabilidade da plástica mitral em 2 anos de seguimento e preservação da contração dinâmica do anel neste período / Introduction: Mitral valve repair is the treatment of choice for mitral regurgitation of degenerative etiology. Recent studies have shown that the use of prosthetic rings in mitral valve repair alters the dynamics of the mitral annulus and intraventricular flow, which may lead to left ventricular dysfunction. However, the literature is scarce in relation to the morphology and dynamics of the mitral annulus after mitral repair without the use of prosthetic rings, and cardiovascular magnetic resonance (CMR) is a tool that can be used in the evaluation of the mitral annulus and the remodeling of the left atrium and left ventricle. Objective: To evaluate the morphological changes and the dynamics of the mitral valve and the remodeling of the left atrium and left ventricle, by CMR, in patients with mitral insufficiency of degenerative etiology who underwent mitral valve surgery with the Double Teflon technique. Methods: From July 2014 to August 2016, 36 consecutive patients with mitral insufficiency of degenerative etiology and prolapse of the posterior leaflet were selected. Three patients underwent mitral valve replacement and four did not perform the CMR, so that 29 patients were included in the protocol and did the proposed follow-up. Of these, 17 patients were male (58.6%) and 12 were female (41.4%), with a mean age of 63.3 years. In relation to functional class (NYHA), one patient was in Class I (3.4%), 5 patients in Class II (17.3%), 19 patients in Class III (65.5%) and 4 patients in Class IV (13.8%) in the preoperative period. Patients underwent CMR examination in the preoperative period, immediate postoperative (up to 30 days), 6 months, one year and two years after surgery, using a specific protocol for mitral valve evaluation. Measurements of the circumference, diameters and mitral ring area were obtained in different phases of the cardiac cycle (diastole, initial systole, mean systole and final systole). Cardiac remodeling was analyzed, and the dimensions, volumes and ejection fraction of the left atrium and left ventricle were used as parameters, and the volumes were indexed by the body surface. We used the analysis of variance of repeated measures for the statistical analysis, being considered statistically significant P < 0.05. Results: There was one hospital death (3,4%). After two years of follow-up, there was a significant improvement in functional class, with 18 patients in Class I (75%) and 6 in Class II (25%). After two years, 18 patients had mild or absent mitral insufficiency (75%) and two patients (8.3%) had important mitral regurgitation, one of them related to late postoperative pacemaker implantation. We observed a significant reduction in all measures of the mitral valve. The mean systolic circumference of the mitral annulus was reduced from 13.28 ± 1.95 to 11.5 ± 1.59 cm and the diastolic circumference was reduced from 12.51 ± 2.01 to 10.66 ± 2.09 cm in the immediate postoperative period, measures that remained stable after 2 years (P < 0.001). The mean maximal area of the mitral annulus in the preoperative, immediate postoperative, 6 months, 1 year and 2 years was 14.34 ± 4.03 cm, 10.72 ± 2.81 cm, 10.92 ± 3,03 cm, 10.98 ± 3.45 cm, 10.45 ± 3.17 cm, respectively. The mean minimal area of the mitral annulus in the preoperative, immediate postoperative, 6 months, 1 year and 2 years was 12.53 ± 3.68 cm2, 9.60 ± 2.44 cm2, 9.66 ± 2.9 cm2, 9.60 ± 3.73 cm2, 9.23 ± 2.84 cm2, respectively. There was a significant reduction of these parameters at two-year follow-up (p < 0.001), and this reduction was greater in the antero-posterior diameter than in the midlateral diameter. The contraction or variation of the mitral valve area during the cardiac cycle was 23.31 ± 9.04%, 19.63 ± 7.01%, 23.75 ± 8.09%, 25.75 ± 11.27%, 22.66 ± 9.77% respectively in the preoperative, postoperative, 6 months, 1 year and 2 years, without statistical difference (p = 0.572), which means that the contractility of the ring was preserved after surgery. We observed reduction of left ventricular and left atrial volumes in the follow-up, being more significant the reduction of the left ventricle end-diastolic volume index. Conclusion: We observed a significant reduction of the mitral annulus after surgery, in all the measurements obtained, with stability of the mitral repair in 2 years of follow-up and preservation of the dynamic contraction of the ring in this period
|
32 |
Análise morfofuncional cardíaca com o uso da ecocardiografia tridimensional em tempo real em indivíduos submetidos à plastia valvar mitral pela técnica de duplo teflon / Cardiac morphologic and functional analysis using real time tridimensional echocardiography in individuals submitted to mitral valve repair by double teflon techniqueGuedes, Marco Antonio Vieira 17 August 2010 (has links)
INTRODUÇÃO: A plastia valvar mitral é o tratamento de escolha para a correção da insuficiência mitral mixomatosa. Estudos ecocardiográficos tridimensionais demonstram que a plastia mitral com implante de anéis protéticos altera a morfologia e a função do anel valvar mitral, porém a literatura é escassa em relação ao comportamento do anel mitral após a plastia mitral sem utilização de anéis protéticos. OBJETIVO: Analisar a morfologia e a função cardíaca de indivíduos submetidos à plastia valvar mitral pela técnica de Duplo Teflon, através da ecocardiografia tridimensional em tempo real. CASUÍSTICA: Foram incluídos 14 pacientes portadores de insuficiência mitral secundária a degeneração mixomatosa, que foram submetidos à plastia valvar mitral pela técnica de Duplo Teflon. Destes, 10 pacientes eram do sexo masculino e a idade média foi de 61,3 ± 11,2 anos. Em relação à classe funcional, 13 pacientes encontravam-se em classe III ou IV no período pré-operatório. Na análise ecocardiográfica pré-operatória, o valor médio do volume diastólico final do ventrículo esquerdo foi 156,57 ± 46,61ml, e a fração de ejeção do ventrículo esquerdo variou de 38 a 68%, com média de 57,93 ± 6,67%. O valor médio do anel mitral posterior foi 6,97 ± 0,13 cm. MÉTODOS: Os pacientes foram avaliados nos períodos pré-operatório, pós-operatório imediato (POI), 6 meses e 1 ano após a plastia mitral. A ecocardiografia tridimensional avaliou a morfologia do anel mitral através das medidas do anel anterior e posterior, dos diâmetros transversos e da área valvar. A função anular foi avaliada pela relação entre as áreas valvares internas durante a sístole e diástole. Foram avaliados os volumes e a função do átrio e do ventrículo esquerdos. Foi utilizado teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante p < 0,05. RESULTADOS: O anel mitral posterior demonstrou uma redução significativa (p<0,001) no POI, que manteve-se estável durante o estudo. Não houve variação significativa na área valvar durante o estudo. Houve uma redução significativa nos diâmetros ântero-posterior e médio-lateral no POI (p<0,001), porém houve um aumento significativo no diâmetro médio-lateral entre POI e 1 ano. A fração de variação do anel mitral durante o ciclo cardíaco, ao longo do estudo, variou entre 30,92 e 35,75%, não havendo diferença estatisticamente significante. A análise dos volumes sistólicos, atrial e ventricular, demonstrou uma redução volumétrica significativa entre POI e 1 ano (p=0,028 e p=0,020, respectivamente). Entre o pré-operatório e 1 ano, houve uma redução média de 19,9% e 15,4% nos volumes atrial e ventricular, respectivamente. Os volumes diastólicos atrial e ventricular apresentaram uma redução significativa no POI (p<0,001 e p=0,024, respectivamente), permanecendo estáveis ao longo do estudo. Houve aumento na fração de ejeção do átrio esquerdo após 6 meses (p<0,001), porém não houve variação na função ventricular esquerda. CONCLUSÕES: A plastia mitral com a anuloplastia segmentar pela técnica do Duplo Teflon reduziu o anel posterior da valva mitral, que permaneceu estável no período de um ano. A variação da área anular mitral durante o ciclo cardíaco permaneceu estável durante o estudo. Além disso, houve um remodelamento reverso atrial e ventricular esquerdo, associado à melhora na função do átrio esquerdo / INTRODUCTION: Mitral valve repair is the treatment of choice to correct mixomatous mitral insufficiency. Tridimensional echocardiography studies demonstrate that mitral repair using prosthetic ring implant modifies mitral valve annulus morphology and function, although the literature related to mitral valve annulus behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE: Analyze cardiac morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon technique. CASUISTIC: Were included 14 patients with mitral valve insufficiency secondary to mixomatous degeneration that were submitted to mitral valve repair with the Double Teflon technique. Of them, 10 patients were male and the mean age was 61.3 ± 11.2 years. According to preoperatively functional class, 13 patients were in class III or IV. In preoperative echocardiographic analysis, the mean value of left ventricle end diastolic volume was 156.57 ± 46.61ml, and the left ventricle ejection fraction ranged between 38 and 68%, with average of 57.93 ± 6.67%. The mean value of the posterior annulus was 6.97 ± 0.13 cm. METHODS: Patients were evaluated in preoperative period, immediate postoperative period, 6 months and 1 year after mitral repair. Tridimensional echocardiography evaluated mitral annulus morphology by anterior and posterior measurements, transverse diameters and valve area. The annular function was evaluated through the ratio between internal valve areas during systole and diastole. Were evaluated left atrial and ventricle volumes and function. Statistic analysis was made by repeated measures ANOVA test and was considered statistically significant p < 0.05. RESULTS: Posterior mitral annulus demonstrated a significant reduction in immediate postoperative period (p<0.001), remaining stable during the study. There was no significant variation in valve area during the study. There was a significant reduction in anteroposterior and mediolateral diameters in the immediate postoperative period (p<0.001), although there was a significant increase in mediolateral diameter between immediate postoperative period and 1 year. Annular area variation over the cardiac cycle during the study ranged between 30.92 and 35.75%, without statistic significance. The analysis of systolic volumes, atrial and ventricular, demonstrated a significant volumetric reduction between immediate postoperative period and 1 year (p=0.028 and p=0.020, respectively). Between preoperative period and 1 year, there was a mean reduction in atrial and ventricle volumes of 19.9% and 15.4%, respectively. Atrial and ventricle diastolic volumes presented a significant reduction in immediate postoperative period (p<0.001 and p=0.024, respectively), remaining stable during the study. There was an increase in left atrial ejection fraction after 6 months (p<0.001), although there was no significant variation in left ventricle ejection fraction. CONCLUSIONS: Mitral valve repair with segmentar annuloplasty with the Double Teflon technique reduced the posterior mitral annulus, which remained stable in 1 year period. The variation in mitral annulus area during cardiac cycle remained stable during the study. Furthermore, there was a left atrial and ventricle reverse remodeling, associated with an improvement in left atrial function
|
33 |
Emprego de veias preservadas em glicerol como substituto de enxerto de nervo: estudo experimental em ratos / Use of glycerol preserved veins as substitute of nerve graft: experimental study in ratsCunha, Armando dos Santos 03 September 2007 (has links)
Grandes perdas de tecido neural não permitem a reparação por meio de anastomose primária. Nesses casos, a auto-enxertia de nervo é considerado o melhor tratamento. A despeito de um tratamento cirúrgico adequado, déficits funcionais são observados e melhoras quanto à recuperação funcional e diminuição das seqüelas são desejáveis. Várias são as técnicas que almejaram esse propósito. A interposição de condutores tubulares, como ponte entre os cotos proximal e distal do nervo seccionado, apresenta-se como uma técnica alternativa que oferece vantagens teóricas. A veia é um material estudado como possível condutor tubular avaliado experimentalmente e em casos clínicos. Estudos recentes têm dado importância na utilização de transplantes de tecidos armazenados em banco de tecidos. O glicerol é utilizado para preservação de tecidos, tendo sido relatado seu uso em nervos e vasos. Entretanto, não há relatos da utilização de veias preservadas em glicerol como substituto de enxerto de nervo. O objetivo deste trabalho foi comparar, em ratos, o grau de regeneração neural, utilizando análise histológica e análise funcional, obtida com a interposição de enxerto autógeno de nervo, veia autógena, veia autógena preservada em glicerol e veia alógena preservada em glicerol. Com técnica microcirúrgica, foram criados defeitos de 5 mm do nervo fibular de ratos da raça Lewis. Os animais foram divididos em quatro grupos de seis, de acordo com o tratamento empregado para correção do defeito: nos animais do Grupo A (grupo controle), foi realizado o reposicionamento do fragmento de nervo retirado (auto-enxerto); nos animais do Grupo B, foi interposto um segmento de 1 cm de veia jugular externa autógena; nos animais do Grupo C, foi interposto a veia jugular externa autógena preservada em glicerol a 98% a 4ºC por sete dias; no Grupo D os animais doadores foram ratos da raça Sprague-Dawley que tiveram a veia jugular externa preservada em glicerol de forma igual ao Grupo C e utilizadas para reconstrução do defeito neural em ratos da raça Lewis, sendo considerado um enxerto alógeno preservado em glicerol. Os animais foram sacrificados após seis semanas para realização dos estudos histológicos. Para a avaliação da recuperação funcional foram estudados os padrões de deambulação dos ratos (\"walking track analysis\") no pós-operatório imediato, 3 e 6 semanas de pós-operatório. O grupo controle (auto-enxerto) apresentou resultados histológicos semelhantes aos grupos de veias preservadas em glicerol (autógena e alógena), entretanto apresentou uma maior reação tecidual perineural e maior presença de escape axonal se comparada a todos os grupos. A utilização de veia autógena sem preservação demonstrou padrão histológico com maior neoangiogênese e áreas de rarefação axonal com presença de tecido conectivo no estroma neoformado. O padrão histológico foi semelhante nos demais grupos. O grupo que utilizou veia autógena (sem glicerol) apresentou menor recuperação funcional quando comparado com os demais grupos para 3 e 6 semanas. O resultado funcional foi estatisticamente semelhante entre os grupos de veias preservadas (autógena e alógena) e o auto-enxerto. / Great losses of neural tissue cannot be repaired by primary conventional suturing. In such cases, nerve autografting is considered to be the treatment of choice. In spite of adequate surgical treatment, functional deficits occur. Also, improvement in functional recuperation and decrease in sequelae are expected. There are many techniques aiming at this purpose. The interposition of tubular conduits, as a bridge between the ends of a sectioned nerve, among these the vein graft, is an alternative technique which offers theoretical advantages. The vein is a studied material as possible evaluated tubular conductor experimentally and in clinical cases. Recent studies have given importance in the use of tissues transplants stored in banks. Glycerol is used for tissue preservation, having been told to its use in nerves and vessels. However, it does not have studies of the use of glycerol reserved veins in as substitute of nerve graft. The purpose of this study was to compare, in rats, the neural regeneration degree, using histological analysis and functional analysis, obtained after interposition of a nerve graft, autogenous vein, autogenous vein preserved in glycerol and allograft vein preserved in glycerol. A 5 mm neural gap in the fibular nerve of rats (Lewis breed) has been created under microsurgical techinique. Four groups of six animals each have been divided according to the treatment employed: Group A - control group: replacement of the fibular nerve itself (autograft); Group B - a 1omm segment of external jugular vein was interposed; Group C - a preserved external jugular vein in glycerol 98% per 7 days was interposed in the fibular nerve gap; Group D - external jugular vein preserved in glycerol of Sprague-Dawley rats had been used equal form to group C in Lewis rats. The animals had been sacrificed after 6 weeks for accomplishment of the histological studies. The functional walking track analysis was performed after in the pre-op, and in the pos-op (immediately, 3 and 6 weeks). The control group (autograft) presented similar histological results to the groups of glycerol preserved veins (autogenous vein and allograft vein), however it presented a bigger perineural tecidual reaction and bigger presence of escape axonal if compared with all the groups. The use of autogenous vein without preservation demonstrated histological results with greater neoangiogenesis and presence of connective tissue inside the neo-formed stroma. Histological pattern was similar to other studied groups. The group that used autogenous vein (without glycerol) presented little functional recovery for 3 and 6 weeks. No statistical difference was seen between groups A (autograft) and groups C and C(preserved veins) in the degree of functional recovery.
|
34 |
Reconstrução de defeito de nervo fibular em ratos com veia glicerolada: análise histológica e funcional / Peroneal nerve gap reconstruction in rats by using glycerol-preserved veins: histological and functional assessmentCunha, Armando dos Santos 28 May 2013 (has links)
A auto-enxertia de nervo é considerado o melhor tratamento para a restauração de grandes perdas de nervo periférico. Mesmo com o tratamento cirúrgico adequado, déficits funcionais são observados e melhoras quanto à recuperação funcional e diminuição das seqüelas são desejáveis. Várias são as técnicas que almejaram esse propósito. A interposição de condutores tubulares, como ponte entre os cotos proximal e distal do nervo seccionado, apresenta-se como uma técnica alternativa que oferece vantagens teóricas. A veia é um material estudado como possível condutor tubular avaliado experimentalmente e em casos clínicos. Estudos recentes têm dado importância na utilização de transplantes de tecidos armazenados em banco de tecidos. O glicerol é utilizado para preservação de tecidos, tendo sido relatado seu uso em nervos e vasos. Entretanto, não há relatos da utilização de veias preservadas em glicerol como substituto de enxerto de nervo. O objetivo deste trabalho foi comparar, em ratos, o grau de regeneração neural, utilizando análise histológica qualitativa e quantitativa e a recuperação funcional, obtida com a interposição de enxerto autógeno de nervo, veia autógena, veia autógena preservada em glicerol e veia alógena preservada em glicerol. Com técnica microcirúrgica, foram criados defeitos de 5 mm do nervo fibular de ratos da raça Lewis. Os animais foram divididos em quatro grupos de seis, de acordo com o tratamento empregado para correção do defeito: nos animais do Grupo A (grupo controle), foi realizado o reposicionamento do fragmento de nervo retirado (auto- enxerto); nos animais do Grupo B, foi interposto um segmento de 1 cm de veia jugular externa autógena; nos animais do Grupo C, foi interposto a veia jugular externa autógena preservada em glicerol a 98% a 4ºC por sete dias; no Grupo D os animais doadores foram ratos da raça Sprague-Dawley que tiveram a veia jugular externa preservada em glicerol de forma igual ao Grupo C e utilizadas para reconstrução do defeito neural em ratos da raça Lewis, sendo considerado um enxerto alógeno preservado em glicerol. Os animais foram sacrificados após seis semanas para realização dos estudos histológicos. Para a avaliação da recuperação funcional foram estudados os padrões de deambulação dos ratos (walking track analysis)no pós-operatório imediato, 3 e 6 semanas de pós-operatório. O grupo controle (auto-enxerto) apresentou resultados histológicos semelhantes aos grupos de veias preservadas em glicerol (autógena e alógena), entretanto apresentou uma maior reação tecidual perineural e maior presença de escape axonal se comparada a todos os grupos. A utilização de veia autógena sem preservação demonstrou padrão histológico com maior neoangiogênese e áreas de rarefação axonal com presença de tecido conectivo no estroma neoformado. O padrão histológico foi semelhante nos demais grupos. A análise histológica quantitativa demonstrou estatisticamente menor concentração de axônios regenerados no grupo B (veia autógena) do que a dos demais grupos. O grupo que utilizou veia autógena (sem glicerol) apresentou menor recuperação funcional quando comparado com os demais grupos para 3 e 6 semanas. O resultado funcional foi estatisticamente semelhante entre os grupos de veias preservadas (autógena e alógena) e o auto-enxerto / Nerve autografting is considered the best treatment for the restoration of great losses of peripheral nerve. In spite of adequate surgical treatment, functional deficits occur. Also, improvement in functional recuperation and decrease in sequelae are expected. There are many techniques aiming at this purpose. The interposition of tubular conduits, as a bridge between the ends of a sectioned nerve, among these the vein graft, is an alternative technique which offers theoretical advantages. The vein is a studied material as possible evaluated tubular conductor experimentally and in clinical cases. Recent studies have given importance in the use of tissues transplants stored in banks. Glycerol is used for tissue preservation, having been told to its use in nerves and vessels. However, it does not have studies of the use of glycerol reserved veins in as substitute of nerve graft. The purpose of this study was to compare, in rats, the neural regeneration degree, using qualitative and quantitative histological analysis and functional recovery, obtained after interposition of a nerve graft, autogenous vein, autogenous vein preserved in glycerol and allograft vein preserved in glycerol. A 5 mm neural gap in the fibular nerve of rats (Lewis breed) has been created under microsurgical techinique. Four groups of six animals each have been divided according to the treatment employed: Group A Î control group: replacement of the fibular nerve itself (autograft); Group B Î a 1omm segment of external jugular vein was interposed; Group C Î a preserved external jugular vein in glycerol 98% per 7 days was interposed in the fibular nerve gap; Group D - external jugular vein preserved in glycerol of Sprague-Dawley rats had been used equal form to group C in Lewis rats. The animals had been sacrificed after 6 weeks for accomplishment of the histological studies. The functional walking track analysis was performed after in the pre-op, and in the pos-op (immediately, 3 and 6 weeks). The control group (autograft) presented similar histological results to the groups of glycerol preserved veins (autogenous vein and allograft vein), however it presented a bigger perineural tecidual reaction and bigger presence of escape axonal if compared with all the groups. The use of autogenous vein without preservation demonstrated histological results with greater neoangiogenesis and presence of connective tissue inside the neo- formed stroma. Histological pattern was similar to other studied groups. Quantitative histological analysis showed statistically lower concentration of regenerated axons in group B (autogenous vein) than the other groups.The group that used autogenous vein (without glycerol) presented little functional recovery for 3 and 6 weeks. No statistical difference was seen between groups A (autograft) and groups C and C (preserved veins) in the degree of functional recovery
|
35 |
Variáveis hematológicas e perfil do ferro na abdominoplastia após a cirurgia bariátrica / Hematological variables and iron status in abdominoplasty after bariatric surgeryPedroso, Juan Carlos Montano [UNIFESP] 25 May 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:27Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-05-25 / Introdução: O tratamento da deformidade na parede abdominal resultante do emagrecimento após a cirurgia bariátrica é a abdominoplastia, a qual pode induzir anemia pós-operatória. Além disso, a cirurgia bariátrica promove uma tendência a deficiência de ferro. Baixas reservas de ferro comprometem a eritropoese. Não há estudo avaliando o grau de anemia e sua evolução após a abdominoplastia pós-bariátrica. Objetivo: Avaliar a anemia e sua evolução após a abdominoplastia pós-bariátrica. Métodos: Os valores de hemoglobina, reticulócitos, ferro, ferritina, e índice de saturação da transferrina foram mensurados na véspera da abdominoplastia e na primeira, quarta e oitava semana de pós-operatório. A hemoglobina também foi mensurada com 48h de pós-operatório. Vinte mulheres adultas foram operadas e tiveram seus dados comparados com 12 controles. Resultados: Os níveis de hemoglobina caíram, em média, de 12,98g/dL para 10,8g/dL com 48h. Houve um aumento significante da hemoglobina no sétimo dia com correção de um terço do déficit, sem aumentos significantes posteriores. Houve um aumento dos reticulócitos na primeira semana. O ferro sérico e índice de saturação de transferrina caíram na primeira semana e mantiveram-se baixos. Os níveis de ferritina apresentaram aumento não significante na primeira semana e posteriormente caíram. Nenhuma das pacientes foi transfundida. Conclusão: Os níveis de hemoglobina caíram após a abdominoplastia e demonstraram um aumento na primeira semana de pós-operatório, com correção de um terço do déficit de hemoglobina, porém, não recuperaram por completo na oitava semana. Ao término do seguimento, 45% das pacientes desenvolveram deficiência de ferro e apresentaram déficit de hemoglobina maior que as pacientes que mantiveram estoques de ferro normais / Background: The treatment of the abdominal wall deformity resulted from weight loss after bariatric surgery is a mixed type of abdominoplasty, which can induce post-operative anemia. In addition, bariatric surgery itself promotes a tendency to iron deficiency which could compromise erythropoiesis. To our knowledge, there is no study evaluating the degree of anemia and its recovery after post-bariatric abdominoplasty. Methods: The values of hemoglobin, reticulocytes, iron, ferritin and transferrin saturation index were measured the day prior to abdominoplasty and the first, fourth and eighth weeks after surgery. Hemoglobin was measured within 48h after surgery. Twenty adult women underwent surgery and had their data compared with 12 controls. Results: Hemoglobin levels dropped significantly from 12,98g/dL to 10,8g/dL within 48h. Hemoglobin increased significantly to 11,5g/dL by day seven, with correction of one third of the deficit, without significant increases thereafter. There was an increase in reticulocytes in the first week. Serum iron and transferrin saturation index fell in the first week and remained low. Ferritin levels showed no significant increase in the first week and subsequently fell. None of the patients received blood transfusion. Conclusion: Hemoglobin levels fell from 12,98 g/dL to 10,8 g/dL after abdominoplasty and showed an increase in the first week after surgery, with correction of one third of the deficit, but did not completely recover in the eighth week. At the end of the follow-up, 45% of the patients developed an iron deficiency and had a hemoglobin deficit higher than the patients that maintained normal iron stores. / TEDE / BV UNIFESP: Teses e dissertações
|
36 |
Neobexiga gastroileal ortotópica e gastroileocistoplastia laparoscópicas: viabilidade técnica e análise crítica de um modelo experimental em suínos / Laparoscopic orthotopic gastroileal neobladder and gastroileocystoplasty: technical feasibility and critical analysis of an experimental porcine modelEduardo Franco Carvalhal 13 September 2004 (has links)
Introdução: Reservatórios gastroileais (GI) compostos podem apresentar vantagens em relação a segmentos intestinais isolados em cirurgias de reconstrução urinária em pacientes selecionados. Apresentamos aqui as técnicas laparoscópicas de gastroileocistoplastia (ampliação vesical) e de neobexiga gastroileal ortotópica (substituição vesical), realizadas de forma completamente intracorpórea em um modelo suíno experimental. Avalia-se sua viabilidade técnica e resultados funcionais. Métodos: Após padronização da técnica em estudo piloto (três animais), realizaram-se as cirurgias de gastroileocistoplastia (Grupo I; N = 5) e neobexiga GI ortotópica (Grupo II; N = 10), envolvendo os mesmos princípios de ressecção laparoscópica de cunha gástrica e íleo. No grupo II, a criação da neobexiga GI incluiu reimplante ureteral bilateral no segmento gástrico com técnica antirefluxo e anastomose uretro-ileal. Foram utilizados exclusivamente grampeadores e técnicas de sutura livre laparoscópica, de forma completamente intracorpórea. Análise pré e pós-operatória de dados laboratoriais, capacidade vesical, avaliação histológica e por imagem (uretrocistografia, urografia venosa) dos reservatórios resultantes foi concluída ao final do seguimento de 8 a 12 semanas (Grupo I) e quatro a oito semanas (Grupo II). Resultados: Os segmentos ileal e gástrico alcançaram a pelve do animal em todos os casos. Tempo cirúrgico foi de 5,2 h para o Grupo I e 7,4 h para o Grupo II. Não houve conversões ou óbitos intra-operatórios. Todos os reservatórios GI apresentavam-se viáveis por ocasião da eutanásia em ambos os grupos. No Grupo I, quatro dos cinco animais completaram sem intercorrências o seguimento de 8 (N = 2) e 12 (N = 2) semanas. Um animal apresentou deterioração clínica, sendo levado precocemente à eutanásia por pielonefrite e alcalose metabólica. Houve aumento da capacidade vesical (a uma pressão vesical de 20cmH2O) de 650ml para 1025ml (p < 0,05) após a cirurgia de ampliação vesical. No Grupo II, cinco dos 10 animais completaram o seguimento previsto em quatro (N = 3) e oito (N = 2) semanas, com mínima alteração da função renal (Cr pré e pós-operatório=1,4 e 2,2mg/dl, respectivamente; p = 0,09). Três animais tiveram a eutanásia antecipada devido a obstrução ureteral com pielonefrite (N = 2) e alcalose hipoclorêmica severa (N=1). Dois óbitos foram associados a obstrução ureteral bilateral e sepse. Capacidade vesical média das neobexigas foi de 400ml. Não houve casos de refluxo vesico-ureteral à cistografia. Porém, sete das 20 unidades renais (35%) apresentaram estenose uretero-gástrica. Obstrução intestinal (N = 1), fístula gástrica (N = 1) e urinoma (N = 1) foram outras complicações do Grupo II. Conclusões: A ressecção gástrica laparoscópica para ampliação e substituição vesicais é viável e reprodutível. A gastroileocistoplastia laparoscópica apresenta adequado resultado funcional após três meses no modelo suíno. A neobexiga GI laparoscópica é tecnicamente viável no modelo suíno, apesar de sua complexidade. A descrição inicial é apresentada. Aperfeiçoamento da técnica de reimplante ureteral anti-refluxo laparoscópico é necessário antes de sua aplicação clínica. / Introduction: Composite gastroileal (GI) urinary reservoirs may present advantages over the use of isolated intestinal segments for urinary reconstructive procedures in selected patients. Herein, we present the laparoscopic techniques of gastroileocystoplasty (bladder augmentation) and GI orthotopic neobladder (bladder substitution), performed completely intracorporeally in a porcine model. Technical feasibility and functional results of these procedures are evaluated. Methods: After a pilot study (three animals) to technically standardize the procedures, gastroileocystoplasty (Group I, N = 5) and GI orthotopic neobladder (Group II; N = 10) were performed applying the same principles of wedge gastric resection and ileal resection. In Group II, creation of the neobladder included bilateral ureteral reimplantation into the gastric segment with an anti-reflux technique and an urethro-ileoanastomosis. Staplers and free-hand laparoscopic suture techniques were utilized exclusively, in a completely intracorporeal manner. Preop and postoperative analysis of laboratory data, bladder capacity, image (cystourethrography, intravenous urography) and histological evaluation of the resulting GI reservoirs was concluded at the end of follow-up, at eight and 12 weeks (Group I) and four and eight weeks (Group II). Results: Ileal and gastric patches reached the animal pelvis in all cases. Operative times were 5.2h for Group I and 7.4h for Group II. No conversions or intraoperative deaths occurred. All GI reservoirs were viable by the time of euthanasia in both groups. In Group I, four of the five animals completed the scheduled follow-up of 8 (N = 2) and 12 (N = 2) weeks without complications. One animal received early euthanasia due to pyelonephritis and metabolic alkalosis. Bladder capacity (at a bladder pressure of 20cmH2O) increased from 650ml to 1025ml (p < 0.05) after the bladder augmentation procedure. In Group II, five of 10 animals completed the scheduled follow-up at four (N = 3) and eight (N = 2) weeks, with minimal alteration on renal function (pre and postoperative Cr = 1.4 and 2.2mg/dl, respectively; p = 0.09). Three animals had an early euthanasia due to ureteral obstruction and pyelonephritis (N=2) and severe hipochloremic alkalosis (N = 1). Two deaths were associated to bilateral ureteral obstruction and sepsis. Mean bladder capacity for the neobladders was 400ml. No cases of vesico-ureteral reflux were seen at cystourethrography. However, seven of 20 renal units (35%) presented with uretero-gastric stenosis. Bowel obstruction (N = 1), gastric fistula (N = 1) and urinoma (N = 1) were other complications in Group II. Conclusions: Laparoscopic gastric resection for bladder augmentation and substitution purposes is feasible and reproducible. Laparoscopic gastroileocystoplasty presents adequate functional results after three months in the porcine model. Laparoscopic GI neobladder is technically viable in the porcine model, despite its complexity. The initial report is presented. Refinements of laparoscopic anti-reflux ureteral reimplantation techniques are necessary before its clinical application.
|
37 |
Análise morfofuncional cardíaca com o uso da ecocardiografia tridimensional em tempo real em indivíduos submetidos à plastia valvar mitral pela técnica de duplo teflon / Cardiac morphologic and functional analysis using real time tridimensional echocardiography in individuals submitted to mitral valve repair by double teflon techniqueMarco Antonio Vieira Guedes 17 August 2010 (has links)
INTRODUÇÃO: A plastia valvar mitral é o tratamento de escolha para a correção da insuficiência mitral mixomatosa. Estudos ecocardiográficos tridimensionais demonstram que a plastia mitral com implante de anéis protéticos altera a morfologia e a função do anel valvar mitral, porém a literatura é escassa em relação ao comportamento do anel mitral após a plastia mitral sem utilização de anéis protéticos. OBJETIVO: Analisar a morfologia e a função cardíaca de indivíduos submetidos à plastia valvar mitral pela técnica de Duplo Teflon, através da ecocardiografia tridimensional em tempo real. CASUÍSTICA: Foram incluídos 14 pacientes portadores de insuficiência mitral secundária a degeneração mixomatosa, que foram submetidos à plastia valvar mitral pela técnica de Duplo Teflon. Destes, 10 pacientes eram do sexo masculino e a idade média foi de 61,3 ± 11,2 anos. Em relação à classe funcional, 13 pacientes encontravam-se em classe III ou IV no período pré-operatório. Na análise ecocardiográfica pré-operatória, o valor médio do volume diastólico final do ventrículo esquerdo foi 156,57 ± 46,61ml, e a fração de ejeção do ventrículo esquerdo variou de 38 a 68%, com média de 57,93 ± 6,67%. O valor médio do anel mitral posterior foi 6,97 ± 0,13 cm. MÉTODOS: Os pacientes foram avaliados nos períodos pré-operatório, pós-operatório imediato (POI), 6 meses e 1 ano após a plastia mitral. A ecocardiografia tridimensional avaliou a morfologia do anel mitral através das medidas do anel anterior e posterior, dos diâmetros transversos e da área valvar. A função anular foi avaliada pela relação entre as áreas valvares internas durante a sístole e diástole. Foram avaliados os volumes e a função do átrio e do ventrículo esquerdos. Foi utilizado teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante p < 0,05. RESULTADOS: O anel mitral posterior demonstrou uma redução significativa (p<0,001) no POI, que manteve-se estável durante o estudo. Não houve variação significativa na área valvar durante o estudo. Houve uma redução significativa nos diâmetros ântero-posterior e médio-lateral no POI (p<0,001), porém houve um aumento significativo no diâmetro médio-lateral entre POI e 1 ano. A fração de variação do anel mitral durante o ciclo cardíaco, ao longo do estudo, variou entre 30,92 e 35,75%, não havendo diferença estatisticamente significante. A análise dos volumes sistólicos, atrial e ventricular, demonstrou uma redução volumétrica significativa entre POI e 1 ano (p=0,028 e p=0,020, respectivamente). Entre o pré-operatório e 1 ano, houve uma redução média de 19,9% e 15,4% nos volumes atrial e ventricular, respectivamente. Os volumes diastólicos atrial e ventricular apresentaram uma redução significativa no POI (p<0,001 e p=0,024, respectivamente), permanecendo estáveis ao longo do estudo. Houve aumento na fração de ejeção do átrio esquerdo após 6 meses (p<0,001), porém não houve variação na função ventricular esquerda. CONCLUSÕES: A plastia mitral com a anuloplastia segmentar pela técnica do Duplo Teflon reduziu o anel posterior da valva mitral, que permaneceu estável no período de um ano. A variação da área anular mitral durante o ciclo cardíaco permaneceu estável durante o estudo. Além disso, houve um remodelamento reverso atrial e ventricular esquerdo, associado à melhora na função do átrio esquerdo / INTRODUCTION: Mitral valve repair is the treatment of choice to correct mixomatous mitral insufficiency. Tridimensional echocardiography studies demonstrate that mitral repair using prosthetic ring implant modifies mitral valve annulus morphology and function, although the literature related to mitral valve annulus behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE: Analyze cardiac morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon technique. CASUISTIC: Were included 14 patients with mitral valve insufficiency secondary to mixomatous degeneration that were submitted to mitral valve repair with the Double Teflon technique. Of them, 10 patients were male and the mean age was 61.3 ± 11.2 years. According to preoperatively functional class, 13 patients were in class III or IV. In preoperative echocardiographic analysis, the mean value of left ventricle end diastolic volume was 156.57 ± 46.61ml, and the left ventricle ejection fraction ranged between 38 and 68%, with average of 57.93 ± 6.67%. The mean value of the posterior annulus was 6.97 ± 0.13 cm. METHODS: Patients were evaluated in preoperative period, immediate postoperative period, 6 months and 1 year after mitral repair. Tridimensional echocardiography evaluated mitral annulus morphology by anterior and posterior measurements, transverse diameters and valve area. The annular function was evaluated through the ratio between internal valve areas during systole and diastole. Were evaluated left atrial and ventricle volumes and function. Statistic analysis was made by repeated measures ANOVA test and was considered statistically significant p < 0.05. RESULTS: Posterior mitral annulus demonstrated a significant reduction in immediate postoperative period (p<0.001), remaining stable during the study. There was no significant variation in valve area during the study. There was a significant reduction in anteroposterior and mediolateral diameters in the immediate postoperative period (p<0.001), although there was a significant increase in mediolateral diameter between immediate postoperative period and 1 year. Annular area variation over the cardiac cycle during the study ranged between 30.92 and 35.75%, without statistic significance. The analysis of systolic volumes, atrial and ventricular, demonstrated a significant volumetric reduction between immediate postoperative period and 1 year (p=0.028 and p=0.020, respectively). Between preoperative period and 1 year, there was a mean reduction in atrial and ventricle volumes of 19.9% and 15.4%, respectively. Atrial and ventricle diastolic volumes presented a significant reduction in immediate postoperative period (p<0.001 and p=0.024, respectively), remaining stable during the study. There was an increase in left atrial ejection fraction after 6 months (p<0.001), although there was no significant variation in left ventricle ejection fraction. CONCLUSIONS: Mitral valve repair with segmentar annuloplasty with the Double Teflon technique reduced the posterior mitral annulus, which remained stable in 1 year period. The variation in mitral annulus area during cardiac cycle remained stable during the study. Furthermore, there was a left atrial and ventricle reverse remodeling, associated with an improvement in left atrial function
|
38 |
Emprego de veias preservadas em glicerol como substituto de enxerto de nervo: estudo experimental em ratos / Use of glycerol preserved veins as substitute of nerve graft: experimental study in ratsArmando dos Santos Cunha 03 September 2007 (has links)
Grandes perdas de tecido neural não permitem a reparação por meio de anastomose primária. Nesses casos, a auto-enxertia de nervo é considerado o melhor tratamento. A despeito de um tratamento cirúrgico adequado, déficits funcionais são observados e melhoras quanto à recuperação funcional e diminuição das seqüelas são desejáveis. Várias são as técnicas que almejaram esse propósito. A interposição de condutores tubulares, como ponte entre os cotos proximal e distal do nervo seccionado, apresenta-se como uma técnica alternativa que oferece vantagens teóricas. A veia é um material estudado como possível condutor tubular avaliado experimentalmente e em casos clínicos. Estudos recentes têm dado importância na utilização de transplantes de tecidos armazenados em banco de tecidos. O glicerol é utilizado para preservação de tecidos, tendo sido relatado seu uso em nervos e vasos. Entretanto, não há relatos da utilização de veias preservadas em glicerol como substituto de enxerto de nervo. O objetivo deste trabalho foi comparar, em ratos, o grau de regeneração neural, utilizando análise histológica e análise funcional, obtida com a interposição de enxerto autógeno de nervo, veia autógena, veia autógena preservada em glicerol e veia alógena preservada em glicerol. Com técnica microcirúrgica, foram criados defeitos de 5 mm do nervo fibular de ratos da raça Lewis. Os animais foram divididos em quatro grupos de seis, de acordo com o tratamento empregado para correção do defeito: nos animais do Grupo A (grupo controle), foi realizado o reposicionamento do fragmento de nervo retirado (auto-enxerto); nos animais do Grupo B, foi interposto um segmento de 1 cm de veia jugular externa autógena; nos animais do Grupo C, foi interposto a veia jugular externa autógena preservada em glicerol a 98% a 4ºC por sete dias; no Grupo D os animais doadores foram ratos da raça Sprague-Dawley que tiveram a veia jugular externa preservada em glicerol de forma igual ao Grupo C e utilizadas para reconstrução do defeito neural em ratos da raça Lewis, sendo considerado um enxerto alógeno preservado em glicerol. Os animais foram sacrificados após seis semanas para realização dos estudos histológicos. Para a avaliação da recuperação funcional foram estudados os padrões de deambulação dos ratos (\"walking track analysis\") no pós-operatório imediato, 3 e 6 semanas de pós-operatório. O grupo controle (auto-enxerto) apresentou resultados histológicos semelhantes aos grupos de veias preservadas em glicerol (autógena e alógena), entretanto apresentou uma maior reação tecidual perineural e maior presença de escape axonal se comparada a todos os grupos. A utilização de veia autógena sem preservação demonstrou padrão histológico com maior neoangiogênese e áreas de rarefação axonal com presença de tecido conectivo no estroma neoformado. O padrão histológico foi semelhante nos demais grupos. O grupo que utilizou veia autógena (sem glicerol) apresentou menor recuperação funcional quando comparado com os demais grupos para 3 e 6 semanas. O resultado funcional foi estatisticamente semelhante entre os grupos de veias preservadas (autógena e alógena) e o auto-enxerto. / Great losses of neural tissue cannot be repaired by primary conventional suturing. In such cases, nerve autografting is considered to be the treatment of choice. In spite of adequate surgical treatment, functional deficits occur. Also, improvement in functional recuperation and decrease in sequelae are expected. There are many techniques aiming at this purpose. The interposition of tubular conduits, as a bridge between the ends of a sectioned nerve, among these the vein graft, is an alternative technique which offers theoretical advantages. The vein is a studied material as possible evaluated tubular conductor experimentally and in clinical cases. Recent studies have given importance in the use of tissues transplants stored in banks. Glycerol is used for tissue preservation, having been told to its use in nerves and vessels. However, it does not have studies of the use of glycerol reserved veins in as substitute of nerve graft. The purpose of this study was to compare, in rats, the neural regeneration degree, using histological analysis and functional analysis, obtained after interposition of a nerve graft, autogenous vein, autogenous vein preserved in glycerol and allograft vein preserved in glycerol. A 5 mm neural gap in the fibular nerve of rats (Lewis breed) has been created under microsurgical techinique. Four groups of six animals each have been divided according to the treatment employed: Group A - control group: replacement of the fibular nerve itself (autograft); Group B - a 1omm segment of external jugular vein was interposed; Group C - a preserved external jugular vein in glycerol 98% per 7 days was interposed in the fibular nerve gap; Group D - external jugular vein preserved in glycerol of Sprague-Dawley rats had been used equal form to group C in Lewis rats. The animals had been sacrificed after 6 weeks for accomplishment of the histological studies. The functional walking track analysis was performed after in the pre-op, and in the pos-op (immediately, 3 and 6 weeks). The control group (autograft) presented similar histological results to the groups of glycerol preserved veins (autogenous vein and allograft vein), however it presented a bigger perineural tecidual reaction and bigger presence of escape axonal if compared with all the groups. The use of autogenous vein without preservation demonstrated histological results with greater neoangiogenesis and presence of connective tissue inside the neo-formed stroma. Histological pattern was similar to other studied groups. The group that used autogenous vein (without glycerol) presented little functional recovery for 3 and 6 weeks. No statistical difference was seen between groups A (autograft) and groups C and C(preserved veins) in the degree of functional recovery.
|
39 |
"Estudo anatômico comparativo entre o retalho escapular e o retalho perfurante da artéria toracodorsal" / Comparative anatomical study between the thoracodorsal artery perforator flap and the scapular flapLuís Henrique Ishida 16 August 2006 (has links)
Desde a primeira descrição do retalho perfurante de artéria toracodorsal (TAP), sua indicação tem sido questionada por se tratar de um retalho de características semelhantes aos retalhos fasciocutâneos escapulares baseados na artéria circunflexa escapular, que são bem conhecidos e reprodutíveis. Este estudo visa comparar características anatômicas destes dois retalhos, distinguindo-os para uma melhor indicação. Adicionalmente o estudo visa estudar o posicionamento do pedículo perfurante do retalho TAP. Vinte e um pares de retalhos (TAP e escapular) foram dissecados simultaneamente em cadáveres frescos. Os músculos latíssimo do dorso e redondo maior foram seccionados e os dois retalhos foram retirados em peça única. O comprimento do pedículo, diâmetro externo da artéria e da veia, espessura da derme e espessura do tecido celular subcutâneo de ambos os retalhos foram avaliados e comparados de forma pareada. A localização dos pedículos dos retalhos foi avaliada em ambos os retalhos. Os dados obtidos foram analisados estatisticamente através do teste t de Student. O retalho TAP apresentou um pedículo com média de 16,95 cm de comprimento, sendo 50% maior que o do retalho escapular (p<0,05). A espessura média da derme foi 2,12 mm, sendo 42% mais fina do que a do retalho escapular; e a do tecido subcutâneo foi 1,37 cm, sendo 28% mais fina do que a do retalho escapular (p<0,05). O pedículo do retalho TAP apresentou artéria com diâmetro médio de 3,14 mm e veia com diâmetro médio de 3,03 mm, enquanto o pedículo do retalho escapular apresentou artéria com diâmetro médio de 3,33 mm e veia com diâmetro médio de 2,95mm, ambos sem diferenças estatísticas. Nas dissecções estudadas, todos os pedículos dos retalhos escapulares se localizavam no espaço triangular. Já a localização dos pedículos perfurantes do retalho TAP não apresentou nenhum parâmetro constante. O estudo demonstrou que, apesar de se localizarem em sítios anatômicos adjacentes, o retalho TAP possui um pedículo mais longo e sua pele é mais fina do que o retalho escapular. Por outro lado, o posicionamento do pedículo do retalho escapular é constante, enquanto o pedículo perfurante do retalho TAP possui localização variável. / Indication of the thoracodorsal artery perforator (TAP) flap has been questioned because its characteristics are similar to those of scapular flaps based on the scapular circumflex artery. The scope of this study is to compare the anatomic features of these two flaps, differentiating them for a better indication. Twenty-one pairs of flaps (TAP and scapular) were dissected simultaneously in fresh cadavers. The length of the pedicles, thickness of the arteries and veins of the pedicles, and the thickness of the dermis and subcutaneous tissue of the flaps were assessed and compared. The position of the pedicles of both flaps was evaluated. The average length of the TAP flap pedicle was 16.95 cm, and it was 50% longer than the scapular flap (p<0.05). The mean thickness of the dermis was 2.12 mm and of the subcutaneous tissue 1.37 cm, respectively 42% and 28% thinner than the scapular flaps (p<0.05). No significant difference was evident between the thicknesses of the pedicles. The TAP arterial pedicle was 3.14 mm and the venous one 3.03 mm. The scapular flap demonstrated a 3.33 mm arterial pedicle and 2.95 mm for the venous one. The evaluation of the position of the pedicle of the scapular flap was constant; on the other hand, the perforator pedicle of the TAP flap did not show any constant anatomical parameter. The study revealed that although the TAP flap and the scapular flap lie in adjacent anatomical areas, the TAP flap has a longer pedicle and a thinner skin; their vascular pedicles have similar thickness; though the position of the thoracodorsal perforator pedicle is variable, when compared with the scapular flap.
|
40 |
Reconstrução de defeito de nervo fibular em ratos com veia glicerolada: análise histológica e funcional / Peroneal nerve gap reconstruction in rats by using glycerol-preserved veins: histological and functional assessmentArmando dos Santos Cunha 28 May 2013 (has links)
A auto-enxertia de nervo é considerado o melhor tratamento para a restauração de grandes perdas de nervo periférico. Mesmo com o tratamento cirúrgico adequado, déficits funcionais são observados e melhoras quanto à recuperação funcional e diminuição das seqüelas são desejáveis. Várias são as técnicas que almejaram esse propósito. A interposição de condutores tubulares, como ponte entre os cotos proximal e distal do nervo seccionado, apresenta-se como uma técnica alternativa que oferece vantagens teóricas. A veia é um material estudado como possível condutor tubular avaliado experimentalmente e em casos clínicos. Estudos recentes têm dado importância na utilização de transplantes de tecidos armazenados em banco de tecidos. O glicerol é utilizado para preservação de tecidos, tendo sido relatado seu uso em nervos e vasos. Entretanto, não há relatos da utilização de veias preservadas em glicerol como substituto de enxerto de nervo. O objetivo deste trabalho foi comparar, em ratos, o grau de regeneração neural, utilizando análise histológica qualitativa e quantitativa e a recuperação funcional, obtida com a interposição de enxerto autógeno de nervo, veia autógena, veia autógena preservada em glicerol e veia alógena preservada em glicerol. Com técnica microcirúrgica, foram criados defeitos de 5 mm do nervo fibular de ratos da raça Lewis. Os animais foram divididos em quatro grupos de seis, de acordo com o tratamento empregado para correção do defeito: nos animais do Grupo A (grupo controle), foi realizado o reposicionamento do fragmento de nervo retirado (auto- enxerto); nos animais do Grupo B, foi interposto um segmento de 1 cm de veia jugular externa autógena; nos animais do Grupo C, foi interposto a veia jugular externa autógena preservada em glicerol a 98% a 4ºC por sete dias; no Grupo D os animais doadores foram ratos da raça Sprague-Dawley que tiveram a veia jugular externa preservada em glicerol de forma igual ao Grupo C e utilizadas para reconstrução do defeito neural em ratos da raça Lewis, sendo considerado um enxerto alógeno preservado em glicerol. Os animais foram sacrificados após seis semanas para realização dos estudos histológicos. Para a avaliação da recuperação funcional foram estudados os padrões de deambulação dos ratos (walking track analysis)no pós-operatório imediato, 3 e 6 semanas de pós-operatório. O grupo controle (auto-enxerto) apresentou resultados histológicos semelhantes aos grupos de veias preservadas em glicerol (autógena e alógena), entretanto apresentou uma maior reação tecidual perineural e maior presença de escape axonal se comparada a todos os grupos. A utilização de veia autógena sem preservação demonstrou padrão histológico com maior neoangiogênese e áreas de rarefação axonal com presença de tecido conectivo no estroma neoformado. O padrão histológico foi semelhante nos demais grupos. A análise histológica quantitativa demonstrou estatisticamente menor concentração de axônios regenerados no grupo B (veia autógena) do que a dos demais grupos. O grupo que utilizou veia autógena (sem glicerol) apresentou menor recuperação funcional quando comparado com os demais grupos para 3 e 6 semanas. O resultado funcional foi estatisticamente semelhante entre os grupos de veias preservadas (autógena e alógena) e o auto-enxerto / Nerve autografting is considered the best treatment for the restoration of great losses of peripheral nerve. In spite of adequate surgical treatment, functional deficits occur. Also, improvement in functional recuperation and decrease in sequelae are expected. There are many techniques aiming at this purpose. The interposition of tubular conduits, as a bridge between the ends of a sectioned nerve, among these the vein graft, is an alternative technique which offers theoretical advantages. The vein is a studied material as possible evaluated tubular conductor experimentally and in clinical cases. Recent studies have given importance in the use of tissues transplants stored in banks. Glycerol is used for tissue preservation, having been told to its use in nerves and vessels. However, it does not have studies of the use of glycerol reserved veins in as substitute of nerve graft. The purpose of this study was to compare, in rats, the neural regeneration degree, using qualitative and quantitative histological analysis and functional recovery, obtained after interposition of a nerve graft, autogenous vein, autogenous vein preserved in glycerol and allograft vein preserved in glycerol. A 5 mm neural gap in the fibular nerve of rats (Lewis breed) has been created under microsurgical techinique. Four groups of six animals each have been divided according to the treatment employed: Group A Î control group: replacement of the fibular nerve itself (autograft); Group B Î a 1omm segment of external jugular vein was interposed; Group C Î a preserved external jugular vein in glycerol 98% per 7 days was interposed in the fibular nerve gap; Group D - external jugular vein preserved in glycerol of Sprague-Dawley rats had been used equal form to group C in Lewis rats. The animals had been sacrificed after 6 weeks for accomplishment of the histological studies. The functional walking track analysis was performed after in the pre-op, and in the pos-op (immediately, 3 and 6 weeks). The control group (autograft) presented similar histological results to the groups of glycerol preserved veins (autogenous vein and allograft vein), however it presented a bigger perineural tecidual reaction and bigger presence of escape axonal if compared with all the groups. The use of autogenous vein without preservation demonstrated histological results with greater neoangiogenesis and presence of connective tissue inside the neo- formed stroma. Histological pattern was similar to other studied groups. Quantitative histological analysis showed statistically lower concentration of regenerated axons in group B (autogenous vein) than the other groups.The group that used autogenous vein (without glycerol) presented little functional recovery for 3 and 6 weeks. No statistical difference was seen between groups A (autograft) and groups C and C (preserved veins) in the degree of functional recovery
|
Page generated in 0.1414 seconds