• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 48
  • Tagged with
  • 48
  • 48
  • 47
  • 34
  • 34
  • 30
  • 22
  • 16
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Estudo da anatomia dos retalhos pediculados da artéria torácica interna e sua aplicabilidade na reconstrução de cabeça e pescoço / The anatomy of the internal mammary artery pedicled flaps and their use in head and neck reconstructions

Guilherme Cardinali Barreiro 11 March 2015 (has links)
INTRODUÇÃO: As reconstruções com tecidos combinados e bem vascularizados permitem a melhor reabilitação para defeitos extensos em cabeça e pescoço. O padrão-ouro tem sido as transferências microcirúrgicas de tecidos. Porém, há pacientes em que não há vasos receptores cervicais adequados para os transplantes de tecidos livres devido à múltiplas recidivas, ressecções e reconstruções; linfadenectomias cervicais; fístulas e infecções; e o tratamento com radioterapia. Com o aprimoramento do controle oncológico, pacientes nestas circunstâncias são cada vez mais frequentes e há poucas alternativas para reconstrução. OBJETIVO: Descrever a dissecação anatômica de um retalho osteomiocutâneo combinado, pediculado nos vasos torácicos internos, para reconstrução de defeitos complexos em cabeça e pescoço. MÉTODO: Retalhos osteomiocutâneos contendo 6ª e 7ª costelas e músculo reto abdominal foram dissecados bilateralmente em 35 cadáveres, 26 do sexo masculino e 9 do sexo feminino. Estudou-se a vascularização cutânea do abdome superior pelas perfurantes da artéria epigástrica superior superficial (SSEA); e os padrões de vascularização do 6º e 7º arcos costais e músculo reto abdominal a partir dos vasos torácicos internos, musculofrênicos e intercostais. O arco de rotação para segmento cefálico com ponto pivô na margem inferior da primeira costela foi avaliado. RESULTADOS: Foram dissecadas 114 perfurantes SSEA, 62 à direita e 52 à esquerda, com calibre arterial médio homogêneo de 0,68 mm. A maior frequência de perfurantes encontradas foi no grupo de 0,5 a 1,0 mm, com 60 (52,7%) ocorrências. Não houve diferença estatisticamente significativa para localização e calibre em relação ao lado. Também não houve correlação dos calibres com localização, idade, peso e altura dos cadáveres. Sessenta e dois retalhos osteomiocutâneos com pedículo nos vasos torácicos internos, 6° e 7° arcos costais e músculo reto abdominal foram divididos em 3 tipos de acordo com o padrão de vascularização do sexto arco costal. O tipo 1, em que a vascularização da sexta costela é pela artéria musculofrênica, foi o mais frequente, com 46 (74,2%) ocorrências. Dez pedículos vasculares diferentes para os componentes do retalho foram individualizados e medidos bilateralmente. Apenas quatro foram significativamente maiores nos homens e, dois, maiores à direita. Os calibres de todos os pedículos arteriais foram homogêneos em relação ao sexo e ao lado. O comprimento do pedículo para o componente ósseo do retalho variou de 18,5 a 21,6 cm, alcançando mandíbula e maxila em todos as dissecações. Já o componente miocutâneo do reto abdominal atingiu occipício em todos os casos e levou os vasos epigástricos profundos inferiores para possível anastomose vascular. Cinco pacientes foram operados em 2 anos com adequada integração dos retalhos e recuperação do contorno e função mandibulares. CONCLUSÃO: Em todas as dissecações de cadáver as perfurantes SSEA estiveram presentes bilateralmente com calibre maior que 0,3 mm; os retalhos osteomiocutâneos pediculados nos vasos torácicos internos foram constantes e alcançaram o segmento cefálico. Os pacientes operados recuperaram forma e função mandibulares. Este retalho pode ser uma alternativa para reconstruções secundárias em cabeça e pescoço / INTRODUCTION: The use of combined well-vascularized flaps offers better results and rehabilitation for complex head and neck defects. Microsurgical reconstructions are the gold standard. However, there are patients with vessel-depleted necks from multiple recurrences and resections, failed reconstructions, neck dissections, infections, fistulas and radiotherapy, which impair adequate free tissue transfers. With better oncologic therapies, these patients have become more common and lack reconstructive options. OBJECT: To describe a combined ostemyocutaneous pedicled flap based on the internal mammary artery for complex head and neck reconstructions. METHOD: Osteomyocutaneous flaps with 6th and 7th ribs and the rectus abdominis muscle were dissected bilaterally on 35 cadavers, 26 male and 9 female. We studied the upper abdominal irrigation through isolation of the superficial superior epigastric artery perforators (SSEA) and the vascular pedicles to the 6th and 7th ribs, and the rectus abdominis muscle arising from the internal mammary, the musculophrenic and the intercostal arteries. The arc of rotation of the flap to the cephalic segment was tested with the pivot point on the lower margin of the first rib. RESULTS: We dissected 114 SSEA, 62 on the right side and 52 on the left. They had an homogeneous mean arterial diameter of 0,68 mm. Sixty perforators (52,7%) were on the group that ranged from 0,5 to 1,0 mm. After statistical analysis, there were no differences in relation to the side as for location and caliber of the perforators. Neither there was any relation of the arterial calibers to the location, age, weight and height of the cadavers. Sixty-two internal mammary artery pedicled osteomyocutaneous flaps, that carried the 6th and 7th ribs and the rectus abdominis muscle, were divided in 3 types depending on the vascular pattern to the 6th costal arch. Type 1, where the pedicle to the 6th rib branches from the musculophrenic artery, was the most frequent and dissected in 46 flaps (74,2%). Ten different vascular pedicles to the components of the flap were isolated and measured bilaterally. Only four of them were significantly longer in males and, two, were longer on the right side. The arterial diameters were also homogeneous in relation to the side and sex. The pedicle length to the osseous component of the flap varied from 18,5 to 21,6 cm, which allowed to reach mandible and maxilla in all dissections. The myocutaneous component of the rectus abdominis muscle reached the occipitum in all cases and carried along the deep inferior epigastric vessels for vascular anastomosis if needed. Five patients were operated in 2 years with adequate flap integration and recovery of the mandible contour and function. CONCLUSION: In all cadaveric dissections SSEA perforators were bilaterally present with a caliber bigger than 0,3 mm; internal mammary artery osteomyocutaneous pedicled flaps were constant and reached the cephalic segment. The operated patients recovered mandibular form and function. This flap can be an alternative for secondary head and neck reconstructions
42

Ultrassonografia intraoperatória para avaliação da necessidade de duroplastia no tratamento cirúrgico de doentes com malformação de Chiari tipo I / Intra operative ultrasonography for evaluation of the need of duroplasty in surgery for Chiari I malformation

Brock, Roger Schmidt 03 April 2017 (has links)
Objetivos: Malformação de Chiari do tipo I (MC-I) é a principal doença malformativa congênita da junção craniovertebral, manifestando-se com ampla variedade de sinais e sintomas neurológicos. A melhor técnica cirúrgica a ser empregada no tratamento dos pacientes com malformação de Chiari do tipo I é ainda controversa. A descompressão das estruturas da fossa craniana posterior com plástica de ampliação dural é considerada procedimento padrão. Embora efetiva e de baixa morbidade, a craniectomia occipital isolada, sem abertura e ampliação dural, implica maior taxa de recidiva dos sintomas. Métodos que selecionam os pacientes quanto a necessidade da duroplastia não foram estabelecidos. O presente trabalho avalia a eficácia da mensuração intraoperatória da velocidade do fluxo do líquido cefalorraquidiano através da ultrassonografia (USG) na seleção da técnica cirúrgica a ser utilizada. Métodos: Foram analisados de forma prospectiva 49 pacientes submetidos à cirurgia para MC-I. A indicação de craniectomia da fossa posterior associada ou não à plástica de ampliação da dura-máter baseou-se na velocidade do fluxo do líquido cefalorraquidiano, mensurada pela ultrassonografia intraoperatória. Dor cervical, cefaleia e qualidade de vida foram avaliadas antes e após o tratamento cirúrgico. Resultados: Dos 49 pacientes incluídos, 36 pacientes (73%) apresentavam fluxo do líquido cefalorraquidiano superior a 3 cm/s e não foram submetidos a duroplastia ampliadora. Nos 13 (27%) pacientes com fluxo inicial inferior a 3 cm/s, indicou-se craniectomia occipital com duroplastia de ampliação. Não houve diferença significativa entre os dois grupos com relação aos parâmetros estudados. Conclusão: A ultrassonografia intraoperatória com avaliação da dinâmica e velocidade do fluxo do líquido cefalorraquidiano da junção craniovertebral auxilia a indicação de duroplastia durante descompressão da fossa craniana posterior em pacientes adultos com MC-I / Objectives: Chiari malformation Type I (CM-I) is the main congenital malformation disease of the craniovertebral junction, and may be responsible for a variety of neurological symptoms. The ideal surgical technique used to treat patients with CM-I is still controversial. Invasive procedures that enters CSF space and are associated with dural repair, are considered the gold standard. Although effective and less morbidity, isolated bone decompression without dural opening, implies greater recurrence of symptoms. Objective parameters to select patients, who need or not to have a duroplasty performed, have not been established. Our study evaluates the efficacy of intra-operative CSF flow measurement through the use of ultrasonography (USG) as a determining parameter in the selection of these patients. Methods: We analyzed prospectively 49 posterior fossa surgeries for patients with CM-I. Patients underwent decompressive surgery with or without opening of the dura mater after conducting USG intra-operatively with measured flow rate, being adopted 3cm/s flow rate as a determining value. The quality of life before and after surgery and the improvement of neck pain and headache were the parameters evaluated. Results: Of the 49 patients enrolled, 36 patients (73%) had adequate CSF flow above 3 cm / s and have not undergone duroplasty. In 13 (27%) patients with initial flow < 3 cm / s an opening in dura mater was performed together with duroplasty. There was no significant difference between the two groups regarding the parameters studied. Conclusion: Intraoperative ultrasound with measurement of CSF flow, having a flow of 3 cm / s as cut-off, allows the proper selection of patients with CM-I that can have a less invasive surgery with bone decompression without duroplasty
43

"Influência da composição de carreador biodegradável na viabilidade do implante de células mesenquimais indiferenciadas do tecido adiposo humano" / Influence of scaffold composition in the viability of implantation of human adipose derived undifferentiated mesenchymal cells

Dietrich, Isa 09 December 2004 (has links)
Células mesenquimais indiferenciadas humanas foram obtidas por digestão enzimática e centrifugação do produto de lipoaspiração, expandidas in vitro, e implantadas no tecido subcutâneo de camundongos atímicos. No grupo I, cada animal recebeu o implante de uma membrana de 0,25cm2 de ácido glicólico e carbonato de trimetileno semeada com 1 x 106 destas células .No grupo II, cada um recebeu a injeção de 0,2ml de gel de ácido hialurônico reticulado contendo o mesmo número destas células. Com três semanas de implante, células humanas e vasos foram identificados nos dois carreadores. Entretanto, com oito semanas, somente no gel de ácido hialurônico as células humanas e os vasos estavam presentes / Human undifferentiated mesenchymal cells were obtained by enzymatic digestion and centrifugation of the product of liposuction. These cells were expanded, in vitro, and implanted subcutaneously in athymic mice. In group I, each animal received the implant of a 0,25cm2 membrane of glycolic acid and trimethylene carbonate, seeded with 1 x 106 of these cells. In group II, each one received 0,2 ml of cross-linked hyaluronic acid gel containing the same amount of these cells. With three weeks of implantation, human cells and vessels were identified in both carriers. However, with eight weeks of implantation, only in hyaluronic acid gel human cells and vessels were present
44

Avaliação do impacto do processo de limpeza na esterilização de medidores de implantes mamários / Assesment of the cleaning process impact in sterilization of mamary implant sizers

Muradian Filho, José 12 November 2007 (has links)
O procedimento cirúrgico para implantes mamários inclui os chamados medidores, utilizados para a mensuração de volume e geometria antes colocação do implante definitivo na paciente. Esses dispositivos são constituídos por um invólucro de elastômero de silicone grau médico da classe siloxano ou poliuretano e cheios com volumes pré-estabelecidos de gel ou elastômero de silicone, grau médico, sendo apresentados em diversos volumes e formas equivalentes ao volume e forma do implante correspondente. Este trabalho avaliou o processo de limpeza manual dos medidores para implantes, sob o ponto de vista da redução da carga microbiana, propiciando a eficácia do processo de esterilização, nas condições encontradas nos Centros Cirúrgicos Hospitalares e utilizando seus equipamentos usuais. Foram realizados testes de desafio microbiológico em amostras de medidores com superfície texturizada e superfície revestida com poliuretano, utilizando cinco microrganismos (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans e Aspergillus niger) e dois tipos de detergente para comparação: não enzimático e enzimático. Determinou-se a biocarga antes e após a limpeza, e em seguida realizou-se a esterilização a 126°C por 30 minutos (1,4 kgf/cm2) das amostras, que foi avaliada por teste de esterilidade. Os resultados mostraram que a etapa de lavagem contribuiu para a redução de 4 ciclos logarítmicos da população inicialmente considerada e não houve diferença entre os resultados de biocarga dos medidores com superfície texturizada e superfície revestida com poliuretano. O processo de limpeza dos medidores com detergente não enzimático ou enzimático seguido de esterilização apresenta eficiência suficiente para garantir a esterilidade requerida para a utilização dos medidores. / The surgical procedure for mammary implants include the so called sizers, used to measure both volume and geometry prior to the definitive placement in the womans breast. These devices present a silicon elastomer or polyurethane external capsule, medical grade, siloxan class filled with predetermined gel or silicon elastomer volumes, also medical grade and are presented in several shapes and volumes equivalent to the shapes and volumes of the corresponding final implant. This study evaluated the manual cleaning process of the sizers focusing in the bioburden thus rendering an effective sterilization process, under the usual equipment and conditions found in the hospital surgery centers. Microbial challenge tests were performed using 5 microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans and Aspergillus niger) and two types of detergent , non enzymatic and enzymatic for comparison. Bioburden was determined before and after the cleaning procedure and after that samples were sterilized at 126°C (1,4 kgf/cm2) for 30 minutes, which was evaluated through sterility testing. Results shown that the cleaning step contributed to a 4 log cycle reduction in the samples initial bioburden and that there was no difference between bioburden results in both types of sizers (textured or polyurethane capsule). The cleaning process using non enzymatic or enzymatic detergents followed by sterilization shows enough effectiveness to ensure the required sterility for using the sizers.
45

Análise das complicações vasculares em receptores de transplante hepático intervivos

Steinbrück, Klaus January 2012 (has links)
Submitted by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-09-28T13:11:50Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) DISSERTAÇÃO KLAUS STEINBRUCK.pdf: 1704112 bytes, checksum: 061dda187540e95c23369cc5a57f8c98 (MD5) / Approved for entry into archive by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-09-28T13:12:05Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) DISSERTAÇÃO KLAUS STEINBRUCK.pdf: 1704112 bytes, checksum: 061dda187540e95c23369cc5a57f8c98 (MD5) / Made available in DSpace on 2017-09-28T13:12:05Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) DISSERTAÇÃO KLAUS STEINBRUCK.pdf: 1704112 bytes, checksum: 061dda187540e95c23369cc5a57f8c98 (MD5) Previous issue date: 2012 / Hospital Federal de Bonsucesso, Serviço de Cirurgia Hepato-Biliar / O objetivo deste estudo foi avaliar as complicações associadas às reconstruções vasculares nos receptores de Transplante Hepático Intervivos operados no Hospital Federal de Bonsucesso, no período de dezembro de 2001 e fevereiro de 2011. Foram levantados dados referentes aos receptores, seus respectivos doadores e relacionados ao procedimento cirúrgico, visando identificar possíveis fatores de risco ao desenvolvimento das complicações vasculares. Cento e quarenta e quatro transplantes foram realizados em 141 receptores, 76 adultos e 65 crianças. Foram identificadas sete complicações (4,9% do total) da artéria hepática, cinco complicações (3,5%) da veia porta e uma complicação (0,7%) da veia hepática. Devido ao pequeno número de complicações, não foi possível realizar análise estatística de fatores de risco. A sobrevida em um ano dos pacientes com e sem complicação vascular foi de 26% e 82%, respectivamente. A sobrevida em um ano dos enxertos utilizados em pacientes com e sem complicação vascular foi de 15% e 82%, respectivamente. Houve diferença estatística (p < 0,001) na sobrevida de pacientes e enxertos, que foi menor no grupo que apresentou complicações vasculares. Concluiu-se que as técnicas de reconstrução vascular utilizadas no Hospital Federal de Bonsucesso apresentam resultados comparáveis aos grandes centros internacionais. A presença de complicação na reconstrução vascular diminui a sobrevida do receptor e do enxerto / The objective of this study was to evaluate the complications associated with vascular reconstruction in recipients of living donor liver transplantation at Bonsucesso Federal Hospital, between December 2001 and February 2011. Data associated to recipients, their donors and surgical procedure were collected to identify possible risk factors for vascular complications development. One hundred and forty-four transplants were performed in 141 recipients, 76 adults and 65 children. We identified seven hepatic artery complications (4.9% of total), five complications (3.5%) of portal vein and one complication (0.7%) of hepatic vein. Due to the small number of complications, statistical analysis of risk factors could not be performed. The 1-year survival of patients with and without vascular complications was 26% and 82%, respectively. The 1-year survival of grafts in patients with and without vascular complications was 15% and 82%, respectively. There was statistical difference (p <0.001) on survival of patients and grafts, which was lower in the group with vascular complications. It was concluded that techniques used in vascular reconstruction at Bonsucesso Federal Hospital showed results comparable to major international centers. The presence of vascular complications in the reconstruction decreases survival of recipients and grafts
46

Avaliação do impacto do processo de limpeza na esterilização de medidores de implantes mamários / Assesment of the cleaning process impact in sterilization of mamary implant sizers

José Muradian Filho 12 November 2007 (has links)
O procedimento cirúrgico para implantes mamários inclui os chamados medidores, utilizados para a mensuração de volume e geometria antes colocação do implante definitivo na paciente. Esses dispositivos são constituídos por um invólucro de elastômero de silicone grau médico da classe siloxano ou poliuretano e cheios com volumes pré-estabelecidos de gel ou elastômero de silicone, grau médico, sendo apresentados em diversos volumes e formas equivalentes ao volume e forma do implante correspondente. Este trabalho avaliou o processo de limpeza manual dos medidores para implantes, sob o ponto de vista da redução da carga microbiana, propiciando a eficácia do processo de esterilização, nas condições encontradas nos Centros Cirúrgicos Hospitalares e utilizando seus equipamentos usuais. Foram realizados testes de desafio microbiológico em amostras de medidores com superfície texturizada e superfície revestida com poliuretano, utilizando cinco microrganismos (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans e Aspergillus niger) e dois tipos de detergente para comparação: não enzimático e enzimático. Determinou-se a biocarga antes e após a limpeza, e em seguida realizou-se a esterilização a 126°C por 30 minutos (1,4 kgf/cm2) das amostras, que foi avaliada por teste de esterilidade. Os resultados mostraram que a etapa de lavagem contribuiu para a redução de 4 ciclos logarítmicos da população inicialmente considerada e não houve diferença entre os resultados de biocarga dos medidores com superfície texturizada e superfície revestida com poliuretano. O processo de limpeza dos medidores com detergente não enzimático ou enzimático seguido de esterilização apresenta eficiência suficiente para garantir a esterilidade requerida para a utilização dos medidores. / The surgical procedure for mammary implants include the so called sizers, used to measure both volume and geometry prior to the definitive placement in the womans breast. These devices present a silicon elastomer or polyurethane external capsule, medical grade, siloxan class filled with predetermined gel or silicon elastomer volumes, also medical grade and are presented in several shapes and volumes equivalent to the shapes and volumes of the corresponding final implant. This study evaluated the manual cleaning process of the sizers focusing in the bioburden thus rendering an effective sterilization process, under the usual equipment and conditions found in the hospital surgery centers. Microbial challenge tests were performed using 5 microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, Candida albicans and Aspergillus niger) and two types of detergent , non enzymatic and enzymatic for comparison. Bioburden was determined before and after the cleaning procedure and after that samples were sterilized at 126°C (1,4 kgf/cm2) for 30 minutes, which was evaluated through sterility testing. Results shown that the cleaning step contributed to a 4 log cycle reduction in the samples initial bioburden and that there was no difference between bioburden results in both types of sizers (textured or polyurethane capsule). The cleaning process using non enzymatic or enzymatic detergents followed by sterilization shows enough effectiveness to ensure the required sterility for using the sizers.
47

Ultrassonografia intraoperatória para avaliação da necessidade de duroplastia no tratamento cirúrgico de doentes com malformação de Chiari tipo I / Intra operative ultrasonography for evaluation of the need of duroplasty in surgery for Chiari I malformation

Roger Schmidt Brock 03 April 2017 (has links)
Objetivos: Malformação de Chiari do tipo I (MC-I) é a principal doença malformativa congênita da junção craniovertebral, manifestando-se com ampla variedade de sinais e sintomas neurológicos. A melhor técnica cirúrgica a ser empregada no tratamento dos pacientes com malformação de Chiari do tipo I é ainda controversa. A descompressão das estruturas da fossa craniana posterior com plástica de ampliação dural é considerada procedimento padrão. Embora efetiva e de baixa morbidade, a craniectomia occipital isolada, sem abertura e ampliação dural, implica maior taxa de recidiva dos sintomas. Métodos que selecionam os pacientes quanto a necessidade da duroplastia não foram estabelecidos. O presente trabalho avalia a eficácia da mensuração intraoperatória da velocidade do fluxo do líquido cefalorraquidiano através da ultrassonografia (USG) na seleção da técnica cirúrgica a ser utilizada. Métodos: Foram analisados de forma prospectiva 49 pacientes submetidos à cirurgia para MC-I. A indicação de craniectomia da fossa posterior associada ou não à plástica de ampliação da dura-máter baseou-se na velocidade do fluxo do líquido cefalorraquidiano, mensurada pela ultrassonografia intraoperatória. Dor cervical, cefaleia e qualidade de vida foram avaliadas antes e após o tratamento cirúrgico. Resultados: Dos 49 pacientes incluídos, 36 pacientes (73%) apresentavam fluxo do líquido cefalorraquidiano superior a 3 cm/s e não foram submetidos a duroplastia ampliadora. Nos 13 (27%) pacientes com fluxo inicial inferior a 3 cm/s, indicou-se craniectomia occipital com duroplastia de ampliação. Não houve diferença significativa entre os dois grupos com relação aos parâmetros estudados. Conclusão: A ultrassonografia intraoperatória com avaliação da dinâmica e velocidade do fluxo do líquido cefalorraquidiano da junção craniovertebral auxilia a indicação de duroplastia durante descompressão da fossa craniana posterior em pacientes adultos com MC-I / Objectives: Chiari malformation Type I (CM-I) is the main congenital malformation disease of the craniovertebral junction, and may be responsible for a variety of neurological symptoms. The ideal surgical technique used to treat patients with CM-I is still controversial. Invasive procedures that enters CSF space and are associated with dural repair, are considered the gold standard. Although effective and less morbidity, isolated bone decompression without dural opening, implies greater recurrence of symptoms. Objective parameters to select patients, who need or not to have a duroplasty performed, have not been established. Our study evaluates the efficacy of intra-operative CSF flow measurement through the use of ultrasonography (USG) as a determining parameter in the selection of these patients. Methods: We analyzed prospectively 49 posterior fossa surgeries for patients with CM-I. Patients underwent decompressive surgery with or without opening of the dura mater after conducting USG intra-operatively with measured flow rate, being adopted 3cm/s flow rate as a determining value. The quality of life before and after surgery and the improvement of neck pain and headache were the parameters evaluated. Results: Of the 49 patients enrolled, 36 patients (73%) had adequate CSF flow above 3 cm / s and have not undergone duroplasty. In 13 (27%) patients with initial flow < 3 cm / s an opening in dura mater was performed together with duroplasty. There was no significant difference between the two groups regarding the parameters studied. Conclusion: Intraoperative ultrasound with measurement of CSF flow, having a flow of 3 cm / s as cut-off, allows the proper selection of patients with CM-I that can have a less invasive surgery with bone decompression without duroplasty
48

"Influência da composição de carreador biodegradável na viabilidade do implante de células mesenquimais indiferenciadas do tecido adiposo humano" / Influence of scaffold composition in the viability of implantation of human adipose derived undifferentiated mesenchymal cells

Isa Dietrich 09 December 2004 (has links)
Células mesenquimais indiferenciadas humanas foram obtidas por digestão enzimática e centrifugação do produto de lipoaspiração, expandidas in vitro, e implantadas no tecido subcutâneo de camundongos atímicos. No grupo I, cada animal recebeu o implante de uma membrana de 0,25cm2 de ácido glicólico e carbonato de trimetileno semeada com 1 x 106 destas células .No grupo II, cada um recebeu a injeção de 0,2ml de gel de ácido hialurônico reticulado contendo o mesmo número destas células. Com três semanas de implante, células humanas e vasos foram identificados nos dois carreadores. Entretanto, com oito semanas, somente no gel de ácido hialurônico as células humanas e os vasos estavam presentes / Human undifferentiated mesenchymal cells were obtained by enzymatic digestion and centrifugation of the product of liposuction. These cells were expanded, in vitro, and implanted subcutaneously in athymic mice. In group I, each animal received the implant of a 0,25cm2 membrane of glycolic acid and trimethylene carbonate, seeded with 1 x 106 of these cells. In group II, each one received 0,2 ml of cross-linked hyaluronic acid gel containing the same amount of these cells. With three weeks of implantation, human cells and vessels were identified in both carriers. However, with eight weeks of implantation, only in hyaluronic acid gel human cells and vessels were present

Page generated in 0.3625 seconds