• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • 1
  • Tagged with
  • 56
  • 44
  • 41
  • 38
  • 34
  • 16
  • 15
  • 15
  • 13
  • 13
  • 13
  • 12
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Efeito do armazenamento prolongado em água sobre a resistência de união entre resinas para reembasamento e resina para base de prótese /

Azevedo, Andréa. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Eunice Teresinha Giampaolo / Banca: Cláudio Rodrigues Leles / Resumo: Este estudo avaliou o efeito da armazenagem prolongada em água sobre a resistência de união entre uma resina acrílica para base de prótese (Lucitone 550) e quatro resinas para reembasamento (Kooliner - K, New Truliner - NT, Tokuso Rebase - TR e Ufi Gel Hard - UGH). Além disso, a resistência de união ao cisalhamento de corpos-de-prova reembasados com a resina acrílica para base de prótese L foi avaliada para comparação. Cilindros (20 mm X 20 mm) de resina acrílica L foram polimerizados (em água a 70°C por 90 minutos, e por 30 minutos à temperatura de ebulição) de acordo com instruções do fabricante e imersos em água destilada (37 l 1°C por 48 l 2 horas). As superfícies de união foram polidas com lixa de granulação 240, escovadas com detergente (20 segundos), limpas com água destilada e secas com papel absorvente. As superfícies foram, então, preparadas por meio da aplicação do monômero da resina L (180 segundos) para a resina K e com os agentes de união (20 segundos) para as demais resinas. Uma fita adesiva com orifício (3,5 mm) foi fixada sobre a superfície tratada para padronizar a área de união. Cada cilindro foi acoplado a uma matriz metálica bipartida com um orifício central (3,5 mm X 5,0 mm). Os materiais para reembasamento foram manipulados, inseridos na matriz e polimerizados de acordo com as instruções dos fabricantes. Após a polimerização, os corpos-de-prova de cada material reembasador foram divididos em cinco grupos (n=8) e submetidos aos testes de cisalhamento (velocidade = 0,5 mm/min). Para o grupo controle (G1), os testes foram realizados imediatamente após a polimerização, para as resinas de reembasamento, e após os corpos-de-prova terem sido imersos em água (37 l 1° C) por 48 l 2 horas para a resina de base L. Os corpos-de-prova relativos aos Grupos 2, 3 e 4 foram testados após terem sido armazenados em água (37 l 1° C)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of long-term water storage on the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. Cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions, and stored in distilled water (37 l 1° C for 48 l 2 hours). The surfaces to be bonded were ground with 240-grit silicon carbide paper, brushed with detergent (20 s), washed in distilled water, and blot-dried. The bonding sites were prepared by painting the surfaces with L monomer (180 seconds) for resin K, and with the bonding agents (30 seconds) for the other resins. A tape with a circular opening (3.5 mm) was placed on the treated surfaces to provide a uniform bonding area. Each cylinder was placed in a stainless steel split mold with a center hole (3.5x5.0 mm). The reline materials were mixed, applied to the mold, and polymerized according to the manufacturers' instructions. After polymerization, specimens of each reline material were divided into 5 groups (n=8), and submitted to shear tests (at a 0.5 mm/min cross-head speed). For control group (G1), the tests were performed immediately after processing for the reline resins, and after the specimens had been stored in water (37 l 1° C) for 48 l 2 hours for the denture base resin L. Groups G2, G3 and G4 specimens were tested after being stored in water (37 l 1° C) for 7 days, 3 months, and 6 months, respectively. The fractured surfaces were examined using scanning electron microscope and an image analysis system to determine the percentage surface area that remained...(Complete abstract click elctronic access below) / Mestre
22

Efeito da desinfecção química e por microondas na alteração dimensional e resistência de união de resinas para reembasamento imediato e resina termopolimerizável /

Gonçalves, Alessandro Ribeiro. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Carlos Eduardo Vergani / Banca: João Neudenir Arioli Filho / Banca: Arlindo Abreu de Castro Filho / Banca: Eduardo Miyashita / Resumo: Esse estudo avaliou o efeito da desinfecção química e por irradiação com microondas sobre a estabilidade dimensional e a resistência ao cisalhamento entre uma resina termopolimerizável para base de prótese (Lucitone 550-L) e quatro resinas autopolimerizáveis para reembasamento (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Foi avaliada também a resistência ao cisalhamento de corpos-de-prova reembasados com a resina L. Para cada material, 48 corpos-de-prova (50 mm diâmetro x 0.5 mm espessura) foram preparados, seguindo-se as recomendações dos fabricantes, utilizando-se uma matriz metálica circular com pontos de referência (A, B, C e D). Um projetor de perfil Nikon foi utilizado para mensurar a distância entre os pontos de referências (AB e CD) na matriz metálica e nos corpos-de-prova. Os corpos-de-prova foram divididos em 6 grupos (n=8) e as mensurações foram realizadas após as seguintes condições experimentais: G1- 2 ciclos de desinfecção química (corpos-de-prova imersos em solução de perborato de sódio a 3,8% aquecida a 50º C por 10 minutos); G2- 2 ciclos de desinfecção com microondas (corpos-de-prova imersos em 200 mL de água e irradiados com 650 W por 6 minutos); G3- 7 ciclos de desinfecção química; G4- 7 ciclos de desinfecção com microondas; C1- grupo controle 1- após a polimerização para as resinas de reembasamento e após imersão em água a 37° C por 48 + 2 horas para a resina de base; C2- grupo controle 2- corpos-de-prova imersos em água a 37° C por 7 dias. Para os grupos G3 e G4, os corpos-de-prova foram mantidos em água a 37° C entre os ciclos de desinfecção. As diferenças entre as mensurações realizadas nos corpos-de-prova e as da matriz foram calculadas e expressas em porcentagem de alteração dimensional linear. Para avaliar a resistência de união, foram confeccionados cilindros ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of chemical and microwave disinfection on the linear dimensional change and the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. For each material, 48 disks (50 mm diameter and 0.5 mm thickness) were made by using a stainless steel split mold with reference points (A, B, C and D), following the manufacturers' instructions. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold and on the specimens. Specimens were divided into 6 groups (n=8) and the measurements were made after the following conditions: G1- 2 cycles of chemical disinfection (specimens immersed in 3,8% sodium perborate solution at 50° C for 10 minutes); G2- 2 cycles of microwave disinfection (specimens immersed in 200 mL of water, and irradiated with 650 W for 6 min); G3- 7 cycles of chemical disinfection; G4- 7 cycles of microwave irradiation; G5- after polymerization for the reline resins and after the specimens had been stored in water at 37° C for 48 + 2 hours; G6- specimens immersed in water at 37° C for seven days. For the groups G3 and G4, the specimens were disinfected daily, and stored in water at 37° C between disinfection. The differences between the measurements made on the specimens and on the stainless steel mold were calculated and expressed as percentage of linear dimensional changes. To evaluate the bond strength, cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions ...(Complete abstract, click electronic access below) / Doutor
23

Efeito de tratamentos da superfície de união e materiais reembasadores na resistência ao impacto de resina para base de prótese /

Perez, Luciano Elias da Cruz. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Ana Cláudia Pavarina / Banca: Luiz Antonio Pessan / Resumo: Este estudo avaliou o efeito de tratamentos da superfície de união e de materiais reembasadores na resistência ao impacto de uma resina para base de prótese. Corpos-de-prova foram confeccionados com a resina Lucitone 550 (60x6x2 mm) e reembasados (2 mm) com o mesmo material (L) ou com as resinas para reembasamento imediato Tokuso Rebase (TR) e Ufi Gel Hard (UH). Para o material L, as superfícies de união permaneceram sem tratamento (L/L/ST) ou foram tratadas com o monômero da resina L (metil metacrilato) for 180 segundos (L/L/M). Quando o reembasamento foi realizado com os reembasadores imediatos, os tratamentos de superfície consistiram de aplicação dos agentes adesivos fornecidos pelos fabricantes (L/TR/A - diclorometano e L/UH/A - diclorometano e 2-hidroxietil metacrilato) ou tratamento com o monômero da resina L seguido pelos adesivos (L/TR/MA e L/UH/MA). Corpos-de-prova do material L intacto (60x6x4 mm) também foram confeccionados para se determinar a resistência ao impacto dessa resina. Um total de 140 corpos-de-prova foi confeccionado, sendo 20 para cada condição experimental. Para metade dos corpos-de-prova, os entalhes foram realizados na largura, na superfície correspondente ao material reembasador, com profundidade de 0,8 mm, permanecendo 3,2 mm de material intacto (E1). Para os corpos-de-prova restantes, o entalhe foi realizado na espessura, envolvendo tanto o material reembasador como a resina de base, com profundidade de 1,2 mm (E2), permanecendo 4,8 mm de material intacto. Todos os entalhes, em forma de V, foram realizados na área central do comprimento dos corpos-de-prova. O teste utilizado foi do tipo Charpy, com pêndulo de 0,5 J e distância de 50 mm entre os suportes. Os resultados (kJ/ m2) de cada entalhe foram analisados, separadamente, utilizando-se ANOVA e teste de ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of surface treatments and reline materials on the impact strength of a denture base acrylic resin. Specimens were made using Lucitone 550 resin (60x6x2 mm) and relined (2 mm) with the same material (L) or with the hard chair-side reline resins Tokuso Rebase (TR) and Ufi Gel Hard (UH). For material L, the bond surfaces remained untreated (L/L/ST) or were wetted with resin L monomer (methyl methacrylate) for 180 seconds (L/L/M). When the relining was made with the hard reline materials, the surface treatments consisted of coating with the bonding agents supplied by the manufacturers (L/TR/A - dichloromethane and L/UH/A - dichloromethane and 2-hydroxyethyl methacrylate) or wetting with the resin L monomer followed by bonding agents application (L/TR/MA and L/UH/MA). Material L intact specimens (60x6x4 mm) were also made to determine the impact strength of the bulk resin. A total of 140 specimens were made, 20 for each experimental condition. Half of the specimens were notched across the width to a depth of 0.8 mm, leaving an effective depth under notch of 3.2 mm (E1). For the remaining specimens, the notch was cut across the thickness to a depth of 1.2 mm (E2) leaving an effective depth under notch of 4.8 mm. All the V-notches were machined at the midpoint of the length of the specimens. Impact tests were carried out on a Charpy type pendulum impact tester (0.5 J pendulum; distance between supporting points - 50 mm). Results (kJ/ m2) from each notch depth were analyzed separately using one-way ANOVA and Tukey's HSD tests (a = .05). No significant differences were noted among the mean impact values of L (1.39 kJ/ m2), L/L/ST (1.28 kJ/ m2) and L/L/M (1.20 kJ/ m2) specimens with the E1 notch (P>.05). Similar results were observed (P>.05) for the specimens with the E2 notch (L - 1.00 kJ/ m2; L/L/ST - 0.93 kJ/ m2; ...(Complete abstract, click electronic access below) / Mestre
24

Avaliação eletromiográfica e análise da qualidade de vida de edentados totais antes e após o reembasamento das próteses inferiores / Electromyographic evaluation and oral health related quality of life of edentulous before and after mandibular denture relining

Marina Xavier Pisani 30 May 2012 (has links)
O presente estudo teve como objetivo geral analisar o impacto do reembasamento de próteses totais com reembasadores rígido e macio na atividade eletromiográfica e na qualidade de vida relacionada à saúde oral (OHRQoL) de pacientes edentados totais. Quarenta e quatro usuários de próteses totais superiores e inferiores foram distribuídos em dois grupos. No grupo 1 (n=22), as próteses inferiores foram reembasadas com reembasador macio à base de silicone (Mucopren Soft) e no grupo 2, com reembasador rígido à base de resina acrílica (Kooliner) pela técnica direta. A avaliação eletromiográfica dos músculos masseter e temporal e análise da OHRQoL foram realizadas antes do reembasamento (baseline-T0) e após 90 dias (T90) da intervenção. Para avaliação da OHRQoL, foi aplicado o questionário OHIP-EDENT, composto por quatro domínios, e três possíveis respostas (escores) às questões: nunca (0), às vezes (1) e quase sempre (2). Após normalização do sinal eletromiográfico, os pacientes foram instruídos a realizarem a máxima contração voluntária em MIH (teste estático), e as variáveis consideradas foram: POC (%), tors (%) e total de atividade eletromiográfica ou impacto (μV / μ V.s %). Em seguida, mastigaram amendoins, barra de cereal e chocolate (teste dinâmico), com as seguintes variáveis: coordenação neuromuscular (%), frequência (Hz) e impacto (μV / μV.s %). Os resultados foram analisados por meio do modelo linear generalizado (p≤0,05). A comparação dos escores da OHRQoL indicou diferença significante entre T0 e T90, independente do grupo, representando uma melhoria nas questões relacionadas à mastigação (domínio 1; p=0,007), dor oral e desconforto (domínio 4; p= 0,047) e no OHIP em geral (p=0,025). Não houve diferença entre os grupos para nenhum dos domínios e para o OHIP em geral. Os resultados do POC dos músculos masseter e temporal não indicaram diferença significante entre os tempos (POCmas p=0,147; POCtem p=0,469) e entre os grupos (POCmas p=0,549; POCtem p=0,104). Para o tors, não foi encontrada diferença significante entre os grupos (p=0,971), e, houve redução do tors em T90 (p=0). Não houve diferença significante entre os grupos (p=0,067), para o impacto, que aumentou em T90 (p=0). A coordenação neuromuscular durante a mastigação de chocolate (p=0), barra de cereal (p=0) e amendoim (p=0) aumentou em T90 e não houve diferença significante entre os grupos (chocolate p=0,087; barra p=0,185; amendoim p=0,472). Não foi encontrada diferença significante entre os grupos (p=0,530) e tempos (p=0,685) para a frequência da mastigação de chocolate. Para o amendoim e barra de cereal, a frequência aumentou em T90 (amendoim p=0,03; barra p=0,007) e não houve diferença entre os grupos (amendoim p=0,566; barra p=0,173). O impacto, durante mastigação de chocolate, aumentou em T90 (p=0), onde o grupo rígido apresentou maior valor (p=0,018). Durante a mastigação de amendoim e barra de cereal, o impacto aumentou em T90 (amendoim p=0; barra p=0) e não houve diferença significante entre os grupos (amendoim p=0,428; barra p=0,590). Conclui-se que o reembasamento, promoveu aumento na atividade eletromiográfica dos músculos avaliados, bem como melhorias na função mastigatória e na OHRQoL. Para a maioria das variáveis não houve diferença significante entre os reembasadores macio e rígido. / The present study aimed to analyze the impact of denture relining with hard and soft denture liners in the electromyographic activity and oral health related quality of life (OHRQoL) of edentulous patients. Forty and four complete denture wearers were distributed in two groups. In group 1 (n=22), the mandibular dentures were relined with a soft silicone based liner (Mucopren Soft) and in group 2, with a hard acrylic based denture liner (Kooliner) by chairside procedures. The electromyography of masseter and temporal muscles and the OHRQoL analysis were assessed before relining (baseline-T0) and after 90 days (T90) of the intervention. The questionnaire OHIP-EDENT, that was used to evaluate the OHRQoL, is composed of four domains, and three possible answers (scores) to the questions: never (0), sometimes (1) and almost always (2). After the normalization of the electromyographic signal, patients had been instructed to perform the maximum voluntary contraction in MIH (static test), and the following variables were considered: POC (%), tors (%) and total of electromyographic activity or impact (μV / μV.s %). After that, they performed masticatory movements by chewing peanuts, cereal bar and chocolate (dynamic test), with the following variables: neuromuscular coordination (%), frequency (Hz) and impact (μV / μV.s %). The results were analyzed by means of the generalized linear model (p≤0,05). The scores comparison of the OHRQoL indicated significant difference among T0 and T90, regardless the group, which represented an improvement in questions related to mastication (domain 1; p=0,007), oral pain and discomfort (domain 4; p= 0,047) and in overall OHIP (p=0,025). There was no significant difference between the groups for none of the domains and for the overall OHIP. Regarding POC of masseter and temporal, no significant differences between times (POCmas p=0,147; POCtem p=0,469) and groups (POCmas p=0,549; POCtem p=0,104) were found. For tors, significant difference between the groups was not found (p=0,971), and, it decreased in T90 (p=0). There was no significant difference between the groups (p=0,067), for the impact, which increased in T90 (p=0). The neuromuscular coordination during chocolate (p=0), cereal bar (p=0) and peanut (p=0) mastication increased in T90 and there was no significant difference between the groups (chocolate p=0,087; cereal p=0,185; peanut p=0,472). Significant difference between the groups (p=0,530) and times (p=0,685) for the frequency during chocolate mastication was not found. For peanut and cereal bar, the frequency increased in T90 (peanut p=0,03; cereal p=0,007) and there was no difference between the groups (peanut p=0,566; cereal p=0,173). The impact, during chocolate mastication, increased in T90 (p=0), and the hard group presented higher values than the soft (p=0,018). For peanut and bar of cereal mastication, the impact increased in T90 (peanut p=0; bar p=0) and there was no significant difference between the groups (peanut p=0,428; bar p=0,590). It can be concluded that the relining increased the electromyographic activity of the evaluated muscles and improved the masticatory function and the OHRQoL. There was no significant differences among the hard and soft denture liners for most of the tested variables.
25

Efeito do armazenamento prolongado em água sobre a resistência de união entre resinas para reembasamento e resina para base de prótese

Azevedo, Andréa [UNESP] 24 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-24Bitstream added on 2014-06-13T18:58:04Z : No. of bitstreams: 1 azevedo_a_me_arafo.pdf: 1794729 bytes, checksum: de3688df34dcd910d44637e0076e7e4c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito da armazenagem prolongada em água sobre a resistência de união entre uma resina acrílica para base de prótese (Lucitone 550) e quatro resinas para reembasamento (Kooliner - K, New Truliner - NT, Tokuso Rebase - TR e Ufi Gel Hard - UGH). Além disso, a resistência de união ao cisalhamento de corpos-de-prova reembasados com a resina acrílica para base de prótese L foi avaliada para comparação. Cilindros (20 mm X 20 mm) de resina acrílica L foram polimerizados (em água a 70°C por 90 minutos, e por 30 minutos à temperatura de ebulição) de acordo com instruções do fabricante e imersos em água destilada (37 l 1°C por 48 l 2 horas). As superfícies de união foram polidas com lixa de granulação 240, escovadas com detergente (20 segundos), limpas com água destilada e secas com papel absorvente. As superfícies foram, então, preparadas por meio da aplicação do monômero da resina L (180 segundos) para a resina K e com os agentes de união (20 segundos) para as demais resinas. Uma fita adesiva com orifício (3,5 mm) foi fixada sobre a superfície tratada para padronizar a área de união. Cada cilindro foi acoplado a uma matriz metálica bipartida com um orifício central (3,5 mm X 5,0 mm). Os materiais para reembasamento foram manipulados, inseridos na matriz e polimerizados de acordo com as instruções dos fabricantes. Após a polimerização, os corpos-de-prova de cada material reembasador foram divididos em cinco grupos (n=8) e submetidos aos testes de cisalhamento (velocidade = 0,5 mm/min). Para o grupo controle (G1), os testes foram realizados imediatamente após a polimerização, para as resinas de reembasamento, e após os corpos-de-prova terem sido imersos em água (37 l 1° C) por 48 l 2 horas para a resina de base L. Os corpos-de-prova relativos aos Grupos 2, 3 e 4 foram testados após terem sido armazenados em água (37 l 1° C)... / This study evaluated the effect of long-term water storage on the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. Cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions, and stored in distilled water (37 l 1° C for 48 l 2 hours). The surfaces to be bonded were ground with 240-grit silicon carbide paper, brushed with detergent (20 s), washed in distilled water, and blot-dried. The bonding sites were prepared by painting the surfaces with L monomer (180 seconds) for resin K, and with the bonding agents (30 seconds) for the other resins. A tape with a circular opening (3.5 mm) was placed on the treated surfaces to provide a uniform bonding area. Each cylinder was placed in a stainless steel split mold with a center hole (3.5x5.0 mm). The reline materials were mixed, applied to the mold, and polymerized according to the manufacturers' instructions. After polymerization, specimens of each reline material were divided into 5 groups (n=8), and submitted to shear tests (at a 0.5 mm/min cross-head speed). For control group (G1), the tests were performed immediately after processing for the reline resins, and after the specimens had been stored in water (37 l 1° C) for 48 l 2 hours for the denture base resin L. Groups G2, G3 and G4 specimens were tested after being stored in water (37 l 1° C) for 7 days, 3 months, and 6 months, respectively. The fractured surfaces were examined using scanning electron microscope and an image analysis system to determine the percentage surface area that remained...(Complete abstract click elctronic access below)
26

Efeito de tratamentos da superfície de união e materiais reembasadores na resistência ao impacto de resina para base de prótese

Perez, Luciano Elias da Cruz [UNESP] 04 March 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-03-04Bitstream added on 2014-06-13T19:58:17Z : No. of bitstreams: 1 perez_lec_me_arafo.pdf: 742869 bytes, checksum: 6a15f2294a9963313f8b26b36009e31b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito de tratamentos da superfície de união e de materiais reembasadores na resistência ao impacto de uma resina para base de prótese. Corpos-de-prova foram confeccionados com a resina Lucitone 550 (60x6x2 mm) e reembasados (2 mm) com o mesmo material (L) ou com as resinas para reembasamento imediato Tokuso Rebase (TR) e Ufi Gel Hard (UH). Para o material L, as superfícies de união permaneceram sem tratamento (L/L/ST) ou foram tratadas com o monômero da resina L (metil metacrilato) for 180 segundos (L/L/M). Quando o reembasamento foi realizado com os reembasadores imediatos, os tratamentos de superfície consistiram de aplicação dos agentes adesivos fornecidos pelos fabricantes (L/TR/A - diclorometano e L/UH/A - diclorometano e 2-hidroxietil metacrilato) ou tratamento com o monômero da resina L seguido pelos adesivos (L/TR/MA e L/UH/MA). Corpos-de-prova do material L intacto (60x6x4 mm) também foram confeccionados para se determinar a resistência ao impacto dessa resina. Um total de 140 corpos-de-prova foi confeccionado, sendo 20 para cada condição experimental. Para metade dos corpos-de-prova, os entalhes foram realizados na largura, na superfície correspondente ao material reembasador, com profundidade de 0,8 mm, permanecendo 3,2 mm de material intacto (E1). Para os corpos-de-prova restantes, o entalhe foi realizado na espessura, envolvendo tanto o material reembasador como a resina de base, com profundidade de 1,2 mm (E2), permanecendo 4,8 mm de material intacto. Todos os entalhes, em forma de V, foram realizados na área central do comprimento dos corpos-de-prova. O teste utilizado foi do tipo Charpy, com pêndulo de 0,5 J e distância de 50 mm entre os suportes. Os resultados (kJ/ m2) de cada entalhe foram analisados, separadamente, utilizando-se ANOVA e teste de... / This study evaluated the effect of surface treatments and reline materials on the impact strength of a denture base acrylic resin. Specimens were made using Lucitone 550 resin (60x6x2 mm) and relined (2 mm) with the same material (L) or with the hard chair-side reline resins Tokuso Rebase (TR) and Ufi Gel Hard (UH). For material L, the bond surfaces remained untreated (L/L/ST) or were wetted with resin L monomer (methyl methacrylate) for 180 seconds (L/L/M). When the relining was made with the hard reline materials, the surface treatments consisted of coating with the bonding agents supplied by the manufacturers (L/TR/A - dichloromethane and L/UH/A - dichloromethane and 2-hydroxyethyl methacrylate) or wetting with the resin L monomer followed by bonding agents application (L/TR/MA and L/UH/MA). Material L intact specimens (60x6x4 mm) were also made to determine the impact strength of the bulk resin. A total of 140 specimens were made, 20 for each experimental condition. Half of the specimens were notched across the width to a depth of 0.8 mm, leaving an effective depth under notch of 3.2 mm (E1). For the remaining specimens, the notch was cut across the thickness to a depth of 1.2 mm (E2) leaving an effective depth under notch of 4.8 mm. All the V-notches were machined at the midpoint of the length of the specimens. Impact tests were carried out on a Charpy type pendulum impact tester (0.5 J pendulum; distance between supporting points - 50 mm). Results (kJ/ m2) from each notch depth were analyzed separately using one-way ANOVA and Tukey's HSD tests (a = .05). No significant differences were noted among the mean impact values of L (1.39 kJ/ m2), L/L/ST (1.28 kJ/ m2) and L/L/M (1.20 kJ/ m2) specimens with the E1 notch (P>.05). Similar results were observed (P>.05) for the specimens with the E2 notch (L - 1.00 kJ/ m2; L/L/ST - 0.93 kJ/ m2; ...(Complete abstract, click electronic access below)
27

Avaliação clínica do efeito de dois métodos de desinfecção sobre a rugosidade, estabilidade de cor e formação de biofilme de próteses reembasadas

Moffa, Eduardo Buozi [UNESP] 08 December 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-12-08Bitstream added on 2014-06-13T19:37:33Z : No. of bitstreams: 1 moffa_eb_me_arafo.pdf: 364520 bytes, checksum: 78b88b4b24e8bf9b375126539ce30932 (MD5) / Este estudo avaliou clinicamente o efeito de dois métodos para limpeza de próteses sobre a rugosidade, estabilidade de cor e a quantificação de micro-organismos de um reembasador rígido em diferentes intervalos de tempo. Foram selecionados 30 pacientes de ambos os gêneros com idade entre 40 e 80 anos, portadores de prótese total superior com necessidade de reembasamento. Essas próteses foram reembasadas com o material Tokuyama Rebase II Fast segundo as recomendações do fabricante. Em seguida, a amostra foi dividida em três grupos (n=10): GC (Grupo Controle) – os pacientes higienizaram suas próteses três vezes ao dia por meio de escovação com sabão de coco; GP (Grupo Perborato) – os pacientes realizaram escovação com sabão de coco e imersão diária da prótese em solução de perborato de sódio durante 5 minutos; GChx (Grupo Clorexidina) – nesse grupo, além da escovação com sabão de coco, foi realizada diariamente a imersão da prótese por 5 minutos em solução de digluconato de clorexidina 2%. Antes da colocação da prótese, os pacientes foram orientados a enxaguá-la adequadamente. A rugosidade superficial e estabilidade de cor do material reembasador foram avaliadas pelo profissional imediatamente após o reembasamento e após 7, 15, 30, 90, e 180 dias. A coleta de microoganismos foi realizada após 7, 15, 30, 90, e 180 dias. A rugosidade superficial foi mensurada através da utilização de um rugosímetro, que fornece valores em Ra-μm. A estabilidade de cor foi avaliada por meio de um espectrofotômetro portátil (BYK – Gardner). Os valores de ΔE obtidos foram comparados utilizando-se a classificação determinada pelo National Bureau of Standards (NBS). Análise de variância de medidas repetidas no tempo (p=0,05) foi empregada na avaliação dos métodos de desinfecção sobre a rugosidade superficial, estabilidade de cor e contagem... / This study evaluated the effect of two disinfection methods for dentures on the clinical performance and quantification of microorganisms of a hard chairside reline resin in different time period. Thirty patients aged between 40 and 80 who required denture reline treatment, participated in this study. Tokuyama Rebase II was used to reline the complete dentures. After that, the edentulous subjects were ramdomly divided into three groups (n=10) and dentures were cleansed according to three methods: CG (control group) - brushing with coconut soap and soft toothbrush; PG (Perborate group) - brushing according to previous methods and disinfection with sodium perborate for 5 minutes once a day during the entire evaluation period (180 days) and ChxG (Chlorhexidine Group) - brushing according to CG and disinfection with chlorhexidine digluconate 2% for 5 minutes once a day during the entire evaluation period (180 days). Surface roughness and color stability were assessed immediately after the relining and after 7, 15, 30, 90 and 180 days of treatment. Quantitative microbial cultures were taken from the tissue side of each maxillary denture after 7, 15, 30, 90 and 180 days of dentures disinfection. The surface roughness was measured using a roughnes meter, which provides values in Ramicrometers. The color stability was evaluated by means of a portable espctrofotômetro (BYK - Gardner). The ΔE values were compared using the classification determined by the National Bureau of Standards (NBS). Analysis of variance for repeated measures (p = 0.05) were used in the evaluation of disinfection methods on the surface roughness, color stability and microbial counts (cfu / ml). The analysis of variance with repeated measures identified a significant effect only on the time factor (p <0.001) for the values of surface roughness, discoloration and microbial quantification... (Complete abstract click electronic access below)
28

Avaliação mecânica e microbiológica de resinas acrílicas reforçadas com partículas de sílica revestidas com prata / Mechanical and microbiological evaluation of acrylic resins reinforced with sílica-silver particles

Sacorague, Sâmia 03 February 2016 (has links)
Submitted by Sâmia Carolina Mota Cavalcanti Sacorague (samiacmc@gmail.com) on 2016-04-01T02:29:04Z No. of bitstreams: 1 Tese Oficial Sacorague.pdf: 138789678 bytes, checksum: 64a0549f6b21193b17f2359358326d21 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-04-05T16:34:30Z (GMT) No. of bitstreams: 1 sacorague_scm_dr_sjc.pdf: 138789678 bytes, checksum: 64a0549f6b21193b17f2359358326d21 (MD5) / Made available in DSpace on 2016-04-05T16:34:30Z (GMT). No. of bitstreams: 1 sacorague_scm_dr_sjc.pdf: 138789678 bytes, checksum: 64a0549f6b21193b17f2359358326d21 (MD5) Previous issue date: 2016-02-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desta pesquisa foi sintetizar e caracterizar partículas de sílica recobertas com nanopartículas de prata, e avaliar a influência destas quando incorporadas à resina acrílica termicamente ativada e reembasador rígido, em suas características mecânicas e microbiológicas. Uma solução de sílica foi sintetizada pelo método de hidrólise controlada do tetraetilortosilicato (TEOS) em meio alcoólico. Foi adicionada a essa uma solução de nitrato de prata, em duas molaridades (10 mmols e 30 mmols) formando partículas do tipo núcleo-casca. Após centrifugação e secagem, cada pó obtido foi adicionado em duas concentrações: 0.5% e 2%, às resinas analisadas. Foram confeccionadas barras retangulares (n=9) de 30 x 10x 3mm para realização do teste de resistência a flexão de três pontos, rugosidade e ângulo de contato; e 120 amostras em forma de disco (2 mmx10 mm) para análise microbiológica. Como grupo controle teve-se amostras sem nanopartículas. As nanopartículas foram analisadas em microscopia eletrônica de varredura com microanalisador por energia dispersiva de raios-X integrado (EDS), Difratômetro de Raios-X e microscopia eletrônica de transmissão. Uma suspensão de Candida albicans foi utilizada para análise de aderência fúngica, halo de inibição e concentração inibitória mínima. As fotomicrografias mostraram que as nanopartículas de 10 mmols apresentam uma distribuição mais homogênea e menor agregação das nanopartículas de prata na superfície da sílica do que as de 30 mmols. Os resultados indicaram que a resistência a flexão foi afetada negativamente, em ambos materiais, com a adição de 2% de partículas, independente da molaridade. A adição das partículas não alterou a molhabilidade da superfície dos materiais, nem a rugosidade, exceto do grupo de reembasador com partículas de 10mmols, em ambas concentrações. As partículas não apresentaram ação antifúngica para os materiais testados em nenhuma concentração, nem houve a formação de halo. Entretanto, a solução apresentou concentração inibitória mínima a partir de 2.000 ppm. Concluiu-se que em baixas concentrações as nanopartículas não afetaram as características mecânica e de superfície da resina acrílica e do reembasador, entretanto elas não inibiram a formação de biofilme por C. albicans sob os materiais. / This research aimed to synthesize, characterize, and evaluate the influence of the addition of silica-silver core/shell particles in mechanical and antifungal characteristics of thermally active acrylic resins or hard reliner . Silica solution was produced by controlled hydrolysis method of tetraethylorthosilicate (TEOS) in an alcoholic. It was added a silver nitrate solution in two molarities, 10 and 30 milimols, forming core-shell particles. After centrifugation and drying, each obtained powder was added in two concentrations 0.5% and 2% in the resins analyzed. Rectangular samples (n=9) with 30 x10 x3 mm were made to three point bend test), roughness and contact angle, and 120 samples in disc (2 mmx10 mm) for microbiological analysis Samples without particles were used as control. The nanoparticles were analyzed by scanning electron microscopy with dispersive energy microanalyzer integrated X-rays (EDS), X-ray diffractometer and transmission electron microscopy. Candida albicans suspension was used to adhesion test, inhibition zone and minimum inhibitory concentration. Photomicrograph showed that nanoparticles with 10 milimols show a distribution more uniform and less aggregation of silver nanoparticles on the silica surface than 30 millimols. The Three point bend test results showed that the flexural strength was negatively affected in both materials, with the addition of 2% particles, in both molarity. The addition of the nanoparticles did not change the surface wettability or roughness of the materials, except for except the reliner group with 10mmols, in both concentrations. The nanoparticles showed no antifungal action for the materials tested at any concentration, neither was zone innibition. However, the solution presented minimal inhibitory concentration to 2.000 ppm. We conclude that low concentrations nanoparticles do not affect the mechanical characteristics and surface of the acrylic resin or reliner, however they do not reduce biofilm adhesion by C. albicans in the materials.
29

Efeito da desinfecção química e por microondas na alteração dimensional e resistência de união de resinas para reembasamento imediato e resina termopolimerizável

Gonçalves, Andréa [UNESP] 04 April 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-04-04Bitstream added on 2014-06-13T20:06:12Z : No. of bitstreams: 1 goncalves_ar_dr_arafo.pdf: 1974874 bytes, checksum: cb90cfb07e456ba101c0f7c18597c3d6 (MD5) / Esse estudo avaliou o efeito da desinfecção química e por irradiação com microondas sobre a estabilidade dimensional e a resistência ao cisalhamento entre uma resina termopolimerizável para base de prótese (Lucitone 550-L) e quatro resinas autopolimerizáveis para reembasamento (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Foi avaliada também a resistência ao cisalhamento de corpos-de-prova reembasados com a resina L. Para cada material, 48 corpos-de-prova (50 mm diâmetro x 0.5 mm espessura) foram preparados, seguindo-se as recomendações dos fabricantes, utilizando-se uma matriz metálica circular com pontos de referência (A, B, C e D). Um projetor de perfil Nikon foi utilizado para mensurar a distância entre os pontos de referências (AB e CD) na matriz metálica e nos corpos-de-prova. Os corpos-de-prova foram divididos em 6 grupos (n=8) e as mensurações foram realizadas após as seguintes condições experimentais: G1- 2 ciclos de desinfecção química (corpos-de-prova imersos em solução de perborato de sódio a 3,8% aquecida a 50º C por 10 minutos); G2- 2 ciclos de desinfecção com microondas (corpos-de-prova imersos em 200 mL de água e irradiados com 650 W por 6 minutos); G3- 7 ciclos de desinfecção química; G4- 7 ciclos de desinfecção com microondas; C1- grupo controle 1- após a polimerização para as resinas de reembasamento e após imersão em água a 37° C por 48 + 2 horas para a resina de base; C2- grupo controle 2- corpos-de-prova imersos em água a 37° C por 7 dias. Para os grupos G3 e G4, os corpos-de-prova foram mantidos em água a 37° C entre os ciclos de desinfecção. As diferenças entre as mensurações realizadas nos corpos-de-prova e as da matriz foram calculadas e expressas em porcentagem de alteração dimensional linear. Para avaliar a resistência de união, foram confeccionados cilindros... / This study evaluated the effect of chemical and microwave disinfection on the linear dimensional change and the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. For each material, 48 disks (50 mm diameter and 0.5 mm thickness) were made by using a stainless steel split mold with reference points (A, B, C and D), following the manufacturers' instructions. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold and on the specimens. Specimens were divided into 6 groups (n=8) and the measurements were made after the following conditions: G1- 2 cycles of chemical disinfection (specimens immersed in 3,8% sodium perborate solution at 50° C for 10 minutes); G2- 2 cycles of microwave disinfection (specimens immersed in 200 mL of water, and irradiated with 650 W for 6 min); G3- 7 cycles of chemical disinfection; G4- 7 cycles of microwave irradiation; G5- after polymerization for the reline resins and after the specimens had been stored in water at 37° C for 48 + 2 hours; G6- specimens immersed in water at 37° C for seven days. For the groups G3 and G4, the specimens were disinfected daily, and stored in water at 37° C between disinfection. The differences between the measurements made on the specimens and on the stainless steel mold were calculated and expressed as percentage of linear dimensional changes. To evaluate the bond strength, cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions ...(Complete abstract, click electronic access below)
30

Efeito do tempo e da desinfecção por micro-ondas no desempenho clínico e na quantificação de micro-organismos de um reembasador rígido

Ribeiro, Roberta Chuqui [UNESP] 28 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-28Bitstream added on 2014-06-13T20:25:49Z : No. of bitstreams: 1 ribeiro_rc_dr_arafo.pdf: 3026200 bytes, checksum: e7d101d0ede455ed6dd85a16d9ab477c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito da desinfecção por micro-ondas sobre o desempenho clínico e a quantificação de micro-organismos de um reembasador rígido em diferentes intervalos de tempo. Foram selecionados 40 pacientes de ambos os sexos com idade entre 30 e 75 anos, utilizando prótese total superior com necessidade de reembasamento. Essas próteses foram reembasadas com o material Tokuyama Rebase II. Logo após o reembasamento, foi avaliado o escoamento e a lisura do material, classificando-os em satisfatório ou insatisfatório. Em seguida, a amostra foi separada em dois grupos: grupo GC (controle) – os pacientes higienizaram sua prótese três vezes ao dia por meio de escovação com sabão de coco. Além disso, a prótese foi retirada durante a noite, ficando imersa em água e grupo GD (desinfecção por micro-ondas) – nesse grupo, além da escovação com escova dental macia e sabão de coco, foi realizada a desinfecção da prótese por micro-ondas uma vez por semana utilizando a potência de 650W e o tempo de 3 minutos. No período noturno, a prótese também foi imersa em água. O material reembasador foi avaliado por dois profissionais treinados trabalhando separadamente após 7 dias, 15 dias, 1 mês, 3 meses, 6 meses, 9 meses e 1 ano. Foram analisadas as seguintes características: estabilidade de cor, brilho, descoloração ou manchamento, irritação dos tecidos orais, separação ou fratura do material e rugosidade superficial. Além disso, foi realizada a quantificação de micro-organismos presentes na superfície interna da prótese em todos os períodos experimentais. Os dados obtidos foram analisados por análise de variância e pelos testes de Tukey e Friedman, ao nível de significância de 5%. O material apresentou lisura e escoamento satisfatórios em todas as análises após o reembasamento. As próteses reembasadas submetidas à desinfecção... / This study evaluated the effect of disinfection method on the clinical performance and quantification of microbial of a hard chairside reline resin after 1-year service period. Forty adult patients aged between 30 and 75 years, who required denture reline treatment, participated in this study. Tokuyama Rebase II was used to reline complete maxillary dentures. Immediately after the reline, assessment of the flow and smoothness was rated by the clinician as satisfactory and unsatisfactory. The edentulous subjects were randomly divided into 2 groups (n=20) and dentures were cleansed according to two methods: CG (control group)- brushing with coconut soap and soft toothbrush; DG (disinfection group)-brushing according to previous methods and microwave disinfection once a week for 3 min at 650W. Furthermore, all dentures were immersed in water at night. Evaluations were conducted by two examiners working separately. Color stability, gloss, staining or material discoloration, irritation to oral tissue, detachment or frature of material and surface roughness were assessed at 7 and 15 days, 1, 3, 6 and 9 months and 1 year post-placement. Quantitative microbial cultures were taken from the tissue side of each maxillary denture at all experimental periods. The data were analyzed by ANOVA and Friedman and Tukey tests. A 95% confindence level was used. Flow and smoothness of the material during relining were considered to be good or satisfactory in all the cases. Values color alterations of DG were significantly lower than those of CG (P<0.05). Color change observed after 15 days are greater than values obtained at 7 days recall (P<0.05). All color changes observed for the CG were considered noticeable (between 1.5 and 3.0 NBS). In disinfection group, color change was slight (between 0.5 and 1.5 NBS). There were statistically significant... (Complete abstract click electronic access below)

Page generated in 0.0648 seconds