• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comparação entre cimentos resinosos e uma resina \"bulk fill\" na cimentação de pinos de fibra de vidro - Análise de resistência adesiva e dureza / Comparison between resin cements and a \"bulk fill\" resin composite on the luting of fiberglass- reinforced posts cementation - Bond strength and hardness analysis

Lobo, Tamile Rocha da Silva 29 January 2018 (has links)
Este estudo comparou a performance de quarto agentes cimentantes com diferentes estratégias adesivas para cimentação de pinos de fibra de vidro em canais radiculares, através do teste de resistência adesiva e avaliando a dureza em diferentes profundidades. Para isto, foram utilizadas 60 raízes bovinas tratadas endodonticamente. Foram cimentados pinos de fibra de vidro Rebilda Post 20 de acordo com os seguintes protocolos divididos nos seguintes grupos: Grupos QM: Adesivo autocondicionante dual Futurabond DC + cimento resinoso dual Bifix QM; Group SE: Cimento resinoso autocondicionante de polimerização dual Bifix SE; Group RB: Adesivo autocondicionante de polimerização dual Futurabond DC + Resina Rebilda; Group XB: aplicação do adesivo autocondicionante de polimerização dual Futurabond DC + resina composta do tipo \"bulk fill\" X-tra Base. As raízes foram cortadas em fatias de 1mm e separadas em terços, sendo obtidos 2 corpos de prova por terço. Foram avaliadas a resistência adesiva (n=10) e a microdureza (n=5), após uma semana e após 4 meses de armazenamento em água. Para o teste de resistência adesiva (push- out) uma fatia de cada terço foi testada depois de uma semana e as outras 3 fatias provenientes do mesmo dente avaliadas após 4 meses. O ensaio de push out foi realizado a uma velocidade de 0,5mm/min até o deslocamento do pino e/ou fratura da interface adesiva. Para o teste de microdureza 20 dentes foram selecionados aleatoriamente e de cada dente foram obtidas seis 6 fatias que foram armazenadas em água destilada por uma semana até a mensuração em microdurômetro, após uma semana e após 4 meses. Os corpos de prova foram submetidos ao teste de microdureza Knoop em microdurômetro HMV-2000 (Shimadzu, Tokyo, Japan), cinco endentações foram realizadas na camada de cimento de cada fatia. Os dados referentes aos testes de resistência adesiva (push- out) e microdureza foram submetidas análise de variância 3 fatores (ANOVA), teste de tukey (p<0,05) e teste de correlação de Person. Os valores de resistência adesiva não apresentaram diferenças estatísticas significantes quando observado os valores de resistência adesiva entre os grupos QM, RB e XB (p>=0.05), porém menores valores de resistência adesiva foram observados no Grupo SE. Quando considerada a variável envelhecimento não foram encontradas diferenças na resistência adesiva medida em uma semana e 4 meses (p>=0.05). Para a microdureza diferenças estatisticamente significantes foram encontradas nos diferentes terços da raiz (p<0.05). Os agentes cimentantes apresentaram diferenças estatísticas significantes na dureza (p<0.05). O grupo XB apresentou os maiores valores seguido por QM, RB e SE. Os grupos SE, RB e XB não apresentaram 80% da dureza máxima nas fatias correspondentes a região apical do canal radicular. O teste de Person mostrou haver correlação positiva linear entre a resistência adesiva e a dureza medidas antes e após o envelhecimento. O uso cimento resinoso dual, associado a uma aplicação anterior do sistema adesivo, ainda é a escolha mais segura, pois apresentou valores de força de adesão elevados, associados a valores de dureza adequados, mesmo em regiões apicais do canal radicular. / This study compared the performance of four cementitious agents with different adhesive strategies for cementing fiberglass pins in root canals, through the adhesive strength test and evaluating the hardness at different depths. For this, 60 endodontically treated bovine roots were used. Rebilda Post 20 fiberglass pins were cemented according to the following protocols divided into the following groups: QM groups: dual self-etching adhesive Futurabond DC + resin cement Bifix QM; Group SE: Dual polymerization resin cement Bifix SE; Group RB: application of self-etching dual-polymerization adhesive Futurabond DC + resin Rebilda; Group XB: application of the self-etching adhesive for dual polymerization Futurabond DC + composite resin of the bulk fill type X-tra Base. The roots were cut into 1mm slices and separated into thirds, obtaining 2 specimens per third. Bond strength (n =10) and microhardness (n = 5) were evaluated after one week and after 4 months of storage in water. For the push-out test one slice of each third was tested after one week and the other 3 slices from the same tooth evaluated after 4 months. The push out test was performed at a speed of 0.5mm / min until the pin displacement and / or fracture of the adhesive interface. For the microtensile test, 20 teeth were randomly selected and six slices were obtained from each tooth, which were stored in distilled water for one week until microdurometer measurement, after one week and after four months. The specimens were submitted to the Knoop microhardness test in HMV-2000 microdurometer (Shimadzu, Tokyo, Japan), five indentations were performed in the cement layer of each slice. The data for the tests of bond strenght (push-out) and microhardness were submitted to analysis of variance 3 factors (ANOVA) and Tukey test (p <0.05) and Person correlation test. The bond strength values did not present significant statistical differences when the adhesive strength values were observed between the groups QM, RB and XB (p>=0.05), but lower values of adhesive strength were observed in the SE Group. When the aging variable was considered, differences in adhesive strength measured at one week and 4 months (p>=0.05) were not found. For microhardness, statistically significant differences were found in the different thirds of the root (p <0.05). The cementing agents presented significant statistical differences in the hardness (p <0.05). The XB group presented the highest values followed by QM, RB and SE. The groups SE, RB and XB did not present 80% of the maximum hardness in the slices corresponding to the apical region of the root canal. The Person test showed a linear positive correlation between the adhesive strength and the hardness measured before and after aging. The use of dual resin cement, combined with a previous application of the adhesive system, is still the safest choice, since it presented high values of bond strength, associated with adequate hardness values, even in apical regions of the root canal.
2

Comparação entre cimentos resinosos e uma resina \"bulk fill\" na cimentação de pinos de fibra de vidro - Análise de resistência adesiva e dureza / Comparison between resin cements and a \"bulk fill\" resin composite on the luting of fiberglass- reinforced posts cementation - Bond strength and hardness analysis

Tamile Rocha da Silva Lobo 29 January 2018 (has links)
Este estudo comparou a performance de quarto agentes cimentantes com diferentes estratégias adesivas para cimentação de pinos de fibra de vidro em canais radiculares, através do teste de resistência adesiva e avaliando a dureza em diferentes profundidades. Para isto, foram utilizadas 60 raízes bovinas tratadas endodonticamente. Foram cimentados pinos de fibra de vidro Rebilda Post 20 de acordo com os seguintes protocolos divididos nos seguintes grupos: Grupos QM: Adesivo autocondicionante dual Futurabond DC + cimento resinoso dual Bifix QM; Group SE: Cimento resinoso autocondicionante de polimerização dual Bifix SE; Group RB: Adesivo autocondicionante de polimerização dual Futurabond DC + Resina Rebilda; Group XB: aplicação do adesivo autocondicionante de polimerização dual Futurabond DC + resina composta do tipo \"bulk fill\" X-tra Base. As raízes foram cortadas em fatias de 1mm e separadas em terços, sendo obtidos 2 corpos de prova por terço. Foram avaliadas a resistência adesiva (n=10) e a microdureza (n=5), após uma semana e após 4 meses de armazenamento em água. Para o teste de resistência adesiva (push- out) uma fatia de cada terço foi testada depois de uma semana e as outras 3 fatias provenientes do mesmo dente avaliadas após 4 meses. O ensaio de push out foi realizado a uma velocidade de 0,5mm/min até o deslocamento do pino e/ou fratura da interface adesiva. Para o teste de microdureza 20 dentes foram selecionados aleatoriamente e de cada dente foram obtidas seis 6 fatias que foram armazenadas em água destilada por uma semana até a mensuração em microdurômetro, após uma semana e após 4 meses. Os corpos de prova foram submetidos ao teste de microdureza Knoop em microdurômetro HMV-2000 (Shimadzu, Tokyo, Japan), cinco endentações foram realizadas na camada de cimento de cada fatia. Os dados referentes aos testes de resistência adesiva (push- out) e microdureza foram submetidas análise de variância 3 fatores (ANOVA), teste de tukey (p<0,05) e teste de correlação de Person. Os valores de resistência adesiva não apresentaram diferenças estatísticas significantes quando observado os valores de resistência adesiva entre os grupos QM, RB e XB (p>=0.05), porém menores valores de resistência adesiva foram observados no Grupo SE. Quando considerada a variável envelhecimento não foram encontradas diferenças na resistência adesiva medida em uma semana e 4 meses (p>=0.05). Para a microdureza diferenças estatisticamente significantes foram encontradas nos diferentes terços da raiz (p<0.05). Os agentes cimentantes apresentaram diferenças estatísticas significantes na dureza (p<0.05). O grupo XB apresentou os maiores valores seguido por QM, RB e SE. Os grupos SE, RB e XB não apresentaram 80% da dureza máxima nas fatias correspondentes a região apical do canal radicular. O teste de Person mostrou haver correlação positiva linear entre a resistência adesiva e a dureza medidas antes e após o envelhecimento. O uso cimento resinoso dual, associado a uma aplicação anterior do sistema adesivo, ainda é a escolha mais segura, pois apresentou valores de força de adesão elevados, associados a valores de dureza adequados, mesmo em regiões apicais do canal radicular. / This study compared the performance of four cementitious agents with different adhesive strategies for cementing fiberglass pins in root canals, through the adhesive strength test and evaluating the hardness at different depths. For this, 60 endodontically treated bovine roots were used. Rebilda Post 20 fiberglass pins were cemented according to the following protocols divided into the following groups: QM groups: dual self-etching adhesive Futurabond DC + resin cement Bifix QM; Group SE: Dual polymerization resin cement Bifix SE; Group RB: application of self-etching dual-polymerization adhesive Futurabond DC + resin Rebilda; Group XB: application of the self-etching adhesive for dual polymerization Futurabond DC + composite resin of the bulk fill type X-tra Base. The roots were cut into 1mm slices and separated into thirds, obtaining 2 specimens per third. Bond strength (n =10) and microhardness (n = 5) were evaluated after one week and after 4 months of storage in water. For the push-out test one slice of each third was tested after one week and the other 3 slices from the same tooth evaluated after 4 months. The push out test was performed at a speed of 0.5mm / min until the pin displacement and / or fracture of the adhesive interface. For the microtensile test, 20 teeth were randomly selected and six slices were obtained from each tooth, which were stored in distilled water for one week until microdurometer measurement, after one week and after four months. The specimens were submitted to the Knoop microhardness test in HMV-2000 microdurometer (Shimadzu, Tokyo, Japan), five indentations were performed in the cement layer of each slice. The data for the tests of bond strenght (push-out) and microhardness were submitted to analysis of variance 3 factors (ANOVA) and Tukey test (p <0.05) and Person correlation test. The bond strength values did not present significant statistical differences when the adhesive strength values were observed between the groups QM, RB and XB (p>=0.05), but lower values of adhesive strength were observed in the SE Group. When the aging variable was considered, differences in adhesive strength measured at one week and 4 months (p>=0.05) were not found. For microhardness, statistically significant differences were found in the different thirds of the root (p <0.05). The cementing agents presented significant statistical differences in the hardness (p <0.05). The XB group presented the highest values followed by QM, RB and SE. The groups SE, RB and XB did not present 80% of the maximum hardness in the slices corresponding to the apical region of the root canal. The Person test showed a linear positive correlation between the adhesive strength and the hardness measured before and after aging. The use of dual resin cement, combined with a previous application of the adhesive system, is still the safest choice, since it presented high values of bond strength, associated with adequate hardness values, even in apical regions of the root canal.
3

Restauração de dentes tratados endodonticamente: ensaio clínico randomizado e revisão sistemática com metánalise / Restoration of endodontically treated teeth: a randomized clinical trial and a systematic review with meta-analysis

Onofre, Rafael Sarkis 13 December 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:09Z (GMT). No. of bitstreams: 1 Dissertacao_rafael_sarkis_onofre.pdf: 1491340 bytes, checksum: 00453dc2916d638be0bec47f9d29aa11 (MD5) Previous issue date: 2012-12-13 / The best way to restore endodontically treated teeth has been discussed in the literature because some factors can influence the post selection and the final restoration. Two of the most used intra-radicular posts are cast metal posts and glass fiber posts. Moreover, there is a large variability of in vitro studies that evaluate the use of different resin cement and the alterations of technique and the influence in the bond strength of glass fiber posts. The aims of the study were to compare the survival of two types of dental posts used to restore endodontically treated teeth with great damage of coronal walls and verify through a systematic review if there is difference on bond strength of glass fiber posts to dentin between self-adhesive and regular resin cements. Systematic review: In vitro studies that investigated the bond strength of glass fiber post luted with self-adhesive (RC) and regular (RC) were selected. Global comparison between self-adhesive (RC) and regular resin cement was performed. Two subgroup analyses were performed: self-adhesive resin cement x regular resin cement (etch-and-rinse adhesive), self-adhesive resin cement x regular resin cement (self-etch adhesive). The three analyses performed showed favorable results to self-adhesive resin cement. Clinical trial: The teeth were randomly allocated into two groups depending on the post used: glass fiber or cast metal post. Fifty-four (45 women) patients and 72 teeth were evaluated up to 3 years and the survival probabilities were 97.1% and 91.9% to cast metal posts and glass fiber posts. Four failures were observed, 2 glass fiber posts debonding (premolar and anterior tooth), 1 glass fiber post debonding associate with root fracture and 1 root fracture with a cast metal post. We can conclude that in vitro literature seems to suggest that the use of self-adhesive cement could help to achieve higher bond strength of GFPs to the root canal and after 3 years of follow up, both posts presented the same clinical performance and / A melhor maneira de se restaurar dentes tratados endodonticamente vem sendo muito discutida na literatura principalmente porque alguns fatores como a escolha do pino a ser utilizado pode influenciar o resultado final da restauração. Dois dos retentores intra-radiculares mais utilizados atualmente são os núcleos metálicos fundidos e os pinos de fibra de vidro. Além disso, existe uma grande variabilidade de estudos in vitro que avaliam tanto a utilização de diferentes cimentos resinosos como alterações das técnicas e a influência na resistência de união de pinos de fibra de vidro. O objetivo deste trabalho foi avaliar as taxas de sucesso clínico de dentes tratados endodonticamente sem remanescente coronário e restaurados com de pino de fibra de vidro ou núcleo metálico fundido através de um ensaio clínico randomizado. Além disso, realizar uma revisão sistemática da literatura de ensaios in vitro que comparassem a resistência de união de pinos de fibra de vidro cimentados com cimento resinoso regular e cimento resinoso autoadesivo. Para a revisão sistemática, estudos in vitro que avaliaram a resistência de união de pinos de fibra de vidro cimentados com cimento autoadesivo e cimento regular foram selecionados. As seguintes metánalises foram realizadas: comparação global entre cimento autoadesivo x cimento regular e análises de subgrupo cimento autoadesivo x cimento regular (adesivo etch-and-rinse) e cimento autoadesivo x cimento regular (adesivo self-etch). As três análises mostraram resultados estatisticamente significantes e favorecendo o uso de cimento autoadesivo. No ensaio clínico, os dentes selecionados foram randomizados e alocados em 2 grupos dependendo do pino utilizado. Após 3 anos, 54 pacientes (72 dentes: 35 núcleos metálicos fundidos e 37 pinos de fibra de vidro) foram avaliados. As taxas de sobrevivência foram 97,1% e 91,9% para núcleos metálicos fundidos e pinos de fibra de vidro respectivamente. Quatro falhas foram observadas: duas descimentações de pinos de fibra de vidro (pré-molar e dente anterior), uma descimentação de pino de fibra de vidro associada a fratura radicular (pré-molar) e uma fratura radicular associada ao uso de núcleo metálico fundido (molar). Conclui-se que a literatura sugere que o uso de cimento resinoso autoadesivo poderia ajudar a conseguir maior resistência de pinos de fibra vidro ao canal radicular e que após 3 anos, ambos os pinos apresentaram performance semelhante
4

Uso de materiais diretos e indiretos para amplas restaurações: implicações clínicas e laboratoriais / Use of direct and indirect materials for extensive restorations: clinical and laboratory implications

Skupien, Jovito Adiel 14 March 2014 (has links)
Made available in DSpace on 2014-08-20T14:30:19Z (GMT). No. of bitstreams: 1 Tese_Jovito_Adiel_Skupien.pdf: 8297294 bytes, checksum: 72ce694b2bb9e499cf0353c4c4b8df4e (MD5) Previous issue date: 2014-03-14 / Glass fiber posts and composite resins are widely used materials in restorative dentistry. The various forms of presentation and technical approach, as well as different handling prior to their use, can result in diverse outcomes, which can determine the success or failure of the restorative procedure. Thus, the aim of this study was to evaluate the performance of glass fiber posts and composite resins in front of several factors related to it uses in dentistry. For this, the study was divided into three parts: An in vitro study, an in vivo study and a systematic review. The in vitro study aimed to evaluate the effect of cementation delay of indirect composite resin restorations in previously hybridized dentin. Three strategies of cementation were tested through different protocols. Beam-shaped specimens from tooth/restoration were obtained and submitted to microtensile testing to evaluate the bond strength and types of failures, where the results were analyzed by ANOVA and Tukey s post hoc tests and linear regression. Regular cement and adhesive threestep etch-and-rinse adhesive system showed the highest values of bond strength, followed by the same cement and two-step etch-and-rinse adhesive system and the lowest values for self-adhesive cement groups. Linear regression showed an improvement in the bond strength values when three-step adhesive system was used, however, all groups had adequate values of bond strength, even in unfavorable situations. The randomized clinical trial evaluated the longevity of metal-ceramic crown and composite resin restorations performed in endodontically treated teeth that received a glass fiber post. Fifty-six severely damaged teeth but with at least one entire wall were randomly allocated into two groups according to the type of restoration. The longevity was assessed through Kaplan-meier and clinical evaluation by descriptive analysis. The recall rate was 100%, fifty-six teeth were re-evaluated with no absolute failure. However, eight composite resin restorations had failed (all reparable). A significant difference between type of restoration was found. Indirect restorations provided higher acceptable clinical performance after two-year of followup, although composite failures were liable to repair. The systematic review compared factorts that can influence retention of glass fiber posts to intraradicular based on in vitro studies which compared the bond strength of resin cements. Searches were carried out in Pubmed and Scopus database up to December 2013. Thirty-four studies were included in the review and several variables were extracted. The presence of endodontic treatment significantly decrease the bond strength, meanwhile other variables can influence according to the type of resin cement. Thus, factors as type of cement application and pretreatment of post can influence glass fiber post retention, however, self-adhesive resin cements are less sensitive to luting procedures / Pinos de fibra de vidro e resinas compostas são materiais amplamente utilizados em odontologia restauradora. As diferentes formas de apresentação e técnicas de emprego, bem como diferentes manobras prévias às suas utilizações podem implicar em desfechos clínicos mais ou menos favoráveis, que podem determinar o sucesso ou falha de um procedimento restaurador. Assim, o objetivo deste estudo foi avaliar o desempenho de pinos de fibra de vidro e resinas compostas frente a diversos fatores relacionados ao seu uso em odontologia. Para isso, o estudo foi dividido em três partes: estudo in vitro, estudo in vivo e revisão sistemática. O estudo in vitro objetivou avaliar o efeito do retardamento da cimentação de restaurações indiretas de resinas compostas em dentina previamente hibridizada. Três estratégias de cimentação foram testadas com diferentes protocolos. Palitos do conjunto dente/restauração foram obtidos e submetidos ao teste de microtração para avaliação da resistência de união e padrão de fratura, onde os valores foram analisados através de ANOVA e teste post hoc Tukey (!=0,05) e regressão linear. Cimento convencional e sistema adesivo de 3 passos apresentaram os maiores valores de resistência de união, seguidos do mesmo cimento e sistema de 2 passos, sendo os menores valores para o grupo do cimento auto-adesivo. A regressão linear demonstrou uma melhora significativa nos valores de resistência quando o sistema de 3 passos foi utilizado, entretanto, todos os grupos tiveram resultados adequados, mesmo em condições desfavoráveis. O ensaio controlado randomizado avaliou a longevidade de restaurações metalo-cerâmicas e de resinas compostas confeccionadas em dentes tratados endodonticamente que receberam um pino de fibra de vidro. Cinqüenta e seis dentes com a coroa danificada, porém, com uma face intacta, foram alocados em dois grupos aleatoriamente, de acordo com o tipo de restauração. A longevidade das restaurações foi avaliadas através de Kaplan- Meier e critérios clínicos foram analisados de forma descritiva. Com uma taxa de rechamada de 100%, 56 dentes foram reavaliados e nenhum foi perdido. Porém, 8 restaurações de resina composta falharam e sofreram reparos. Houve uma diferença significativa para o tipo de restauração em relação ao sucesso. Assim, restaurações indiretas apresentaram uma melhor performance clínica após 2 anos de acompanhamento, embora as falhas apresentadas no grupo que recebeu resinas diretas tenham sido reparáveis. A revisão sistemática comparou fatores que podem influenciar na retenção de pinos de fibra de vidro em dentina intra-radicular baseado em estudos in vitro que compararam a resistência de união de cimentos resinosos. Após uma busca realizada nos bancos de dados Pubmed e Scopus até dezembro de 2013, trinta e quatro estudos foram incluídos na revisão e diferentes variáveis foram extraídas. A presença de tratamento endodôntico diminuiu significativamente a resistência de união, enquanto que demais variáveis variam sua influência de acordo com o tipo de cimento resinoso. Assim, fatores como método de aplicação do cimento e pré-tratamento do pino podem influenciar a retenção de pinos de fibra de vidro, porém, cimentos auto-adesivos são menos sensíveis à técnica de cimentação

Page generated in 0.0604 seconds