• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Hemodynamic changes in intracranial aneurysms due to stent-induced vascular remodeling /

Santos, Gabriel Bertacco dos. January 2018 (has links)
Orientador: José Luiz Gasche / Resumo: Originalmente, stents foram projetados para agir como barreiras mecânicas, impedindo a herniação de coils para a artéria-mãe. Recentemente, estudos mostraram que a atual geração de stents intracranianos auto-expansíveis altera a geometria local das artérias: um fenômeno com efeitos hemodinâmicos em parte incompreendidos. Nós realizamos simulações numéricas para avaliar a influência da remodelagem arterial induzida por stent sobre a hemodinâmica em aneurismas intracranianos. As simulações foram realizadas utilizando o software open-source OpenFOAM. O sangue foi modelado como fluido Newtoniano incompressível e as paredes arteriais foram consideradas rígidas. Para quantificar as alterações hemodinâmicas, avaliamos os parâmetros wall shear stress, WSS, e oscillatory shear index, OSI. Quatro geometrias reais de aneurismas intracranianos em bifurcações foram utilizadas. Em um aneurisma na bifurcação da artéria comunicante anterior (ACoA), um stent foi implantando, levando ao endireitamento das artérias que o receberam. Após o procedimento, os níveis de WSS e OSI aumentaram aproximadamente 60% e 25%, respectivamente. Em dois aneurismas em bifurcações da artéria cerebral média (MCA), dois stents foram implantados em uma configuração em “Y”, resultando em um endireitamento de ambas as artérias-filhas. O WSS máximo na superfície do aneurisma aumentou aproximadamente 5% em um dos casos e 22% no outro. Em outro aneurisma em uma bifurcação da MCA, um stent foi implantado, resultando no en... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Stents were first designed to act as mechanical barriers, preventing coil herniation into the parent artery. The current generation of self-expanding intracranial stents has recently been shown to change the local vascular geometry, a phenomenon with unclear hemodynamic effects. We carried out numerical simulations to assess the role of stent-induced vascular remodeling in modifying intraaneurysmal hemodynamics. Simulations were performed using the open-source software OpenFOAM. Blood was assumed to behave as an incompressible Newtonian fluid; vessel walls were assumed to be rigid. Wall shear stress, WSS, and oscillatory shear index, OSI, were evaluated to quantify the hemodynamic changes in the aneurysm sac. Four pre- and post-stent patient-specific geometries of intracranial bifurcation aneurysm were used. In one aneurysm at the anterior communicating artery (ACoA) bifurcation, a single stent was deployed, resulting in straightening of the host vessels. After stenting, WSS and OSI increased by approximately 60% and 25%, respectively. In two aneurysms at middle cerebral artery (MCA) bifurcations, two stents in a “Y” configuration were deployed, resulting in straightening of both daughter arteries. The maximum WSS on the aneurysm surface increased by approximately 5% in one case and 22% in the other. In another aneurysm at a bifurcation of the MCA, a single stent was deployed, resulting in straightening of the host vessels. After stenting, WSS and OSI reduced by approximately... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0696 seconds