• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 168
  • 1
  • Tagged with
  • 171
  • 165
  • 84
  • 83
  • 44
  • 30
  • 29
  • 29
  • 26
  • 26
  • 25
  • 25
  • 24
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise e discussão dos conceitos e legislação sobre reuso de águas residuárias / Analysis and argument of the concepts and legislation about reuso of waters residuárias

Muffareg, Marcos Roberto January 2003 (has links)
Made available in DSpace on 2012-09-06T01:11:32Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 556.pdf: 939764 bytes, checksum: a3d41bd191d7609336aab796d680da06 (MD5) Previous issue date: 2003 / Apesar da água ser considerada um recurso natural renovável, a mudança dos ecossistemas, a dinâmica das cidades, a demanda aumentada e diversificada desse recurso mineral nos alerta para sua eminente escassez como fonte de manutenção da vida, seja nas atividades produtivas, agropastoris e até mesmo para o abastecimento público. No Brasil, antes de abordarmos a questão do reuso de água, é importante nos darmos conta do enorme déficit de cobertura de sistemas de esgotos sanitários, com o devido tratamento, adequado aos corpos receptores. Esse déficit além contribuir para a deterioração dos nossos corpos hídricos, interferir na saúde pública, vem cada vez mais, devido ao alto custo no tratamento da água para abastecimento, se transformando em um fator econômico de extrema relevância. Essa demanda por água tem levado os diversos países a se preocupar além da proteção dos seus mananciais a aprofundar estudos sobre reuso das águas servidas. Em todo o mundo, atualmente, estão sendo desenvolvidos vários estudos e revisando várias normas, diretrizes e legislações referentes a reuso de águas residuárias.Pretende-se com esse trabalho, discutir o conceito do reuso de águas, apresentar algumas experiências exitosas pelo mundo e levantar normas e legislações existentes no Brasil e em vários países, a fim de contribuir na construção de um pensar integrado sobre o reuso, que por fim vá ao encontro dos esforços existentes para construção de uma legislação específica sobre o reuso de águas residuárias.
2

Águas cinzas: caracterização, avaliação financeira e tratamento para reuso domiciliar e condominial / Gray waters: characterization, financial evaluation and treatment for use residential and condominial

Rapoport, Beatriz January 2004 (has links)
Made available in DSpace on 2012-09-06T01:12:01Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 643.pdf: 1736397 bytes, checksum: 89cfe1307207187e42c915678805bf08 (MD5) Previous issue date: 2004 / A escassez de água nos grandes centros urbanos, onde a demanda cada vez maior tende a suplantar a oferta, vem sendo motivo de alerta. Uma alternativa para economia do insumo é o seu reuso que vem sendo estimulado principalmente devido à lei de recursos hídricos. Este trabalho propõe o aproveitamento das águas cinzas provenientes de chuveiros e pias de banheiros em descargas sanitárias. Observamos que para implantação de um sistema de reuso das águas cinzas é necessário além de um sistema duplo de distribuição de água, também um tratamento adequado. As análises químicas, físicas e biológicas demonstraram que estas águas apesar de serem menos contaminados que as águas negras necessitam de tratamento para serem reutilizadas com segurança. As águas cinzas analisadas apresentaram baixas concentrações de N e P, SS e Turbidez e alta DQO e DBO além de alta taxa de coliformes totais e fecais. Foram encontrados Estreptococos que estão relacionados com contaminação viral além de helmintos. Sugerimos que para reuso domiciliar em descargas sanitárias seja utilizado o mesmo padrão utilizado para água de banho considerando que os riscos de contaminação são os mesmos. É sugerido nesta dissertação um tratamento simples, de baixo custo e que requer pouca manutenção das instalações. A desinfecção é etapa importante. Deve-se levar em consideração ao se propor o reuso de águas cinzas, as reais condições locais de disponibilidade hídrica. A troca de equipamentos com alto consumo e a educação para economia do insumo não excluem o reuso de águas cinzas em atividades onde a poilidade não é fator preponderante. Relevante seria o controle das perdas do insumo pela concessionária de água e esgoto. A economia gerada com o reuso proposto é significativa podendo chegar a até 60 por cento, tendo como exemplo o modelo de tarifação empregado no Estado do Rio de Janeiro onde é cobrado, além do valor da água, 100 por cento do seu valor devido ao esgotamento sanitário. Estudos sobre demanda e oferta de água no Estado do Rio de Janeiro, indicam que para a região metropolitana, até 2010 haverá uma demanda crescente de água e desta forma, o reuso em médio prazo é uma possibilidade a ser considerada. Medidas imediatas tais como aprovação de projetos com rede dupla de distribuição pelos órgãos competentes e tratamento com vistas ao reuso devem ser incentivadas para que no futuro estas águas possam ser reusadas com segurança em caso de necessidade.
3

Detecção e caracterização molecular de vírus entéricos em águas residuárias na cidade do Rio de Janeiro

Fumian, Túlio Machado January 2011 (has links)
Submitted by Tatiana Silva (tsilva@icict.fiocruz.br) on 2013-02-15T18:15:25Z No. of bitstreams: 1 tulio_m_fumian_ioc_bcm_0064_2011.pdf: 8754950 bytes, checksum: a088189284585292976a95bd6ca62aec (MD5) / Made available in DSpace on 2013-02-15T18:15:25Z (GMT). No. of bitstreams: 1 tulio_m_fumian_ioc_bcm_0064_2011.pdf: 8754950 bytes, checksum: a088189284585292976a95bd6ca62aec (MD5) Previous issue date: 2011 / Fundação Oswaldo Cruz.Instituto Oswaldo Cruz. Rio de janeiro, RJ, Brasil / Entre a grande diversidade de vírus que infectam o homem, muitos são excretados em grandes concentrações nas fezes ou urina de indivíduos sintomáticos ou assintomáticos, estando presentes em águas residuárias provenientes de esgotos domésticos. Metodologias moleculares de amplificação genômica vêm sendo utilizadas para detecção e quantificação de vírus nestas águas, de modo que os estudos de virologia ambiental representam uma ferramenta a mais na determinação dos vírus circulantes em uma dada área geográfica. Este estudo teve como objetivo avaliar a disseminação dos principais vírus responsáveis pela gastrenterite aguda infantil [rotavírus A (RVA), norovírus (NoV) e astrovírus humanos (HAstV)] , em águas residuárias da cidade do Rio de Janeiro, assim como avaliar os adenovírus humanos (HAdV) e poliomavírus JC (JCPyV) como marcadores virais de contaminação ambiental. Com este propósito,metodologias de concentração, detecção, quantificação e caracterização molecular de vírus foram estabelecidas e aplicadas em águas residuárias de duas Estações de Tratamento de Esgoto (ETE) da cidade. Inicialmente, realizou-se o monitoramento de RVA, NoV, HAstV e JCPyV na ETE Fiocruz (2004 -2005) com a utilização do método de concentração viral baseado na ultrafiltração com membrana carregada negativamente. Nestes estudos demonstrou-se a disseminação destes vírus em amostrar de esgoto bruto e em menor escala em esgoto tratado, assim como se avaliou as taxas de recuperação de NoV e HAstV pelo método de concentração utilizado e metodologias de detecção e quantificação viral. A caracterização dos agentes virais detectados demonstrou a circulação dos genótipos mais prevalentes (RVA G1 e P[8]; NoV GII; HAstV-1 e JCPyV tipo 3). As baixas taxas de recuperação viral obtidas com o método de filtração, assim como a ausência de controle interno nos estudos anteriores, apontaram a necessidade de se estabelecer diferentes métodos para investigações. Deste modo, estabeleceu-se o método de concentração de vírus por ultracentrifugação, assim como um protocolo de quantificação do bacteriófago PP7, utilizado como controle interno, e outro para quantificação de RVA. Estes métodos foram aplicados em um novo monitoramento(2009 -2010) realizado em ETE de grande porte (ETE Alegria) visando obter dados mais consistentes dos vírus circulantes na população do Rio de Janeiro. Os resultados provenientes deste monitoramento demonstraram que os RVA, HAdV e os JCPyV foram os mais prevalentes nas amostras de águas residuárias seguidos pelos NoV e HAstV. A caracterização molecular demonstrou a diversidade de genótipos de vírus circulantes em concordância com oso obtidos anteriormente, exceto para os RVA, RVA G2 e P[4] foram caracterizados em 100% das amostras de esgoto bruto revelando uma alteração do perfil dos genótipos circulantes após a introdução da Rotarix® no país em 2006. Neste estudo não foram detectadas cepas vacinais de RVA. Os resultados obtidos na ETE Alegria demonstraram uma redução de 2 logs na carga viral após o tratamento. Os dados quantitativos confirmaram o potencial do HAdV como marcador viral de contaminação, assim como revelaram a importância de se avaliar a descarga local de vírus no ambiente, de modo a se identificar os vírus presentes em altas concentrações que devem ser considerados em estudos de avaliação de risco. / Among the wide variety of viruses that infect humans, many are excreted in high concentrations in the feces or urine of symptomatic or asymptomatic, present in wastewater from domestic sewage. Molecular genomic amplification methodologies have been used for detecting and quantifying viruses in these waters so that their studies of virology environmental represent an additional tool in the determination of circulating virus in a given geographical area. This study aimed to evaluate the spread of the main viruses responsible for infantile acute gastroenteritis [A rotavirus (RVA), norovirus (NoV) and human astrovirus (HAstV)] in wastewater of the city of Rio de Janeiro, as well as evaluating the adenovirus human (HAdV) and JC polyomavirus (JCPyV) as markers of viral contamination. For this purpose, methods of concentration, detection, quantification and molecular characterization of virus were established and applied in two wastewater treatment plants Wastewater (TEE) in the city. Initially, there was monitoring of RVA, NoV, HAstV and JCPyV in ETE Fiocruz (2004 -2005) with the use of viral concentration method based on ultrafiltration membrane with negatively charged. In these studies demonstrated the spread of these viruses sampled in raw sewage and treated sewage on a smaller scale, as well as assessed the recovery rates of NoV and HAstV by concentration method used and methodologies for detecting and quantifying viral. Characterization of viral agents detected the movement of genotypes showed more prevalent (RVA G1 and P [8]; NoV GII; JCPyV HAstV-1 and type 3). The low recovery rates obtained with the virus filtration method, and the absence of internal controls in previous studies, indicate a need to establish different methods for investigation. Thus, it was established method of virus concentration by ultracentrifugation as well as a protocol of quantification of bacteriophage PP7, used as internal control, and another for quantification RVA. These methods were applied to a new monitoring (2009 -2010) held in ETE large (ETE Joy) to obtain more consistent data of virus circulating in the population of Rio de Janeiro. The results from this monitoring showed that RVA, HAdV JCPyV and were most prevalent in samples of wastewater followed by NoV and HAstV. The molecular characterization demonstrated the diversity of genotypes circulating viruses in concordance with previously obtained oso except for RVA, RVA G2 and P [4] were characterized in 100% of samples of raw sewage revealing a change in the profile of circulating genotypes after introduction of Rotarix ® in the country in 2006. This study were not detected RVA vaccine strains. The results obtained in ETE Joy showed a 2 log reduction in viral load after treatment. Quantitative data confirm the potential of HAdV as a marker of viral contamination, and revealed the importance of evaluating the local discharge of virus in the environment in order to identify viruses present in high concentrations that should be considered in evaluation studies risk.
4

Estudo cinético do Processo de Valo Cynamon-Roque: caracterização e obtenção de parâmetros de projeto / Cynamon-Roque ditch process kinetics study: characterization and design criteria establisment

Silva, Dalton Marcondes January 2000 (has links)
Made available in DSpace on 2016-02-26T13:26:11Z (GMT). No. of bitstreams: 2 162.pdf: 5694761 bytes, checksum: 9c22514a37e7fa915b7fe998fc46e8a9 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2000 / O processo de valo Cynamon-Roque, de tratamento de esgotos, constituído de um reator anaeróbio e outro aeróbio, vem sendo testado desde 1986, através de uma unidade piloto, construída no Campus da FIOCRUZ, que recebe uma mistura de esgotos domésticos e industriais, oriundos de unidades de ensino, pesquisa, manutenção e fábricas de vacinas. A validade do processo foi amplamente demonstrada, o que resultou na patente obtida em 1996. As características funcionais vantajosas do processo, em relação aos tradicionais são: requer pouca área, sua operação é simples, a remoção de matéria orgânica é elevada, fruto de uma operação semelhante à do processo dos lodos ativados, permite considerável remoção de nutrientes, não libera aerossóis no meio ambiente, pois a unidade aeróbia é fechada, apresenta boa remoção de patogênicos e economia energética. Neste trabalho, avaliamos as características operacionais do valo Cynamon-Roque, quando sujeito a vazões superiores às do projeto original. Devido às grandes variações horárias de vazão, concentração, do afluente da unidade piloto, e a perda de sólidos, foi empregado um modelo cinético transiente, de pouca complexidade, mas adequado para modelagem matemática do processo de degradação. As perdas de sólidos foram ocasionadas em virtude dos decantadores terem sido dimensionados para vazões muito inferiores às utilizadas. Através deste modelo, testamos a validade de duas equações cinéticas, a de Monod e a de Eckenfelder, para degradação de substrato, obtendo-se ajustes semelhantes. Uma metodologia para obtenção de parâmetros para um projeto racional é apresentada e discutida ao longo deste trabalho. O comportamento do processo, noutras condições operacionais, foi previsto, utilizando-se o modelo cinético, com os parâmetros determinados através do ajuste deste, aos dados experimentais. / Foi realizado um levantamento preliminar sobre a estabilidade do reator anaeróbio, o consumo de oxigênio do reator aeróbio e o desempenho dos decantadores. A comparação do consumo de energia do valo Cynamon-Roque com dois processos tradicionais, o valo clássico e o lodo ativado, demonstrou a grande potencialidade do processo em estudo. / Cynamon-Roque ditch process, a sewage treatment process, given by an anaerobic reactor followed by an aerobic reactor, has been tested since 1986, throw a pilot plant, build in FIOCRUZ Campus, which receive domestic and industrial sewage from teaching, research, repairing units and vaccines industries. The process validity has been quite demonstrated, so it was patented in 1996. The advantageous functional features of the process, taking into account the traditional process are: it needs small areas, its operation is simple, organic matter removal is high, because it works in a similar way to the activated sludge process, nutrients removal is remarkable, it does not release aerosols in the environment, because the aerobic unit is closed, exhibits good removal of pathogenic organism and saves energy.In this work, Cynamon-Roque ditch operational features has been evaluated, when subject to flows bigger than the original project ones. Due to the great hour variations of flow, concentration, of the influent from the pilot plant, and the loss of solids, it was used a transient kinetic model, of little complexity, but appropriate for the bio-degradation process mathematical modeling. The loss of solids was caused by the fact that the settling tanks were designed to operate at much lower flows than those used. Taking into account the model, the validity of two kinetic equations was tested - Monod and Eckenfelder - for the bio-degradation of substrate, and similar fit resulted.A methodology for determining the coefficients necessary for establishing rational design criteria is presented and discussed throughout this work.The process behavior, under other operational conditions, was previewed, through the kinetic model, which coefficients were determined by adjusting it to the experimental data. / A preliminary evaluation was realized about the stability of the anaerobic reactor, the consumption of oxygen in the aerobic reactor and the settling tanks performance. The energy consumption comparison between Cynamon-Roque ditch and two traditional processes - classical ditch and activated sludge - showed the great potential of the process being studied. (AU)^ien
5

Tratamento termofílico do metanol em reatores anaerobicos

de Oliveira Cysneiros, Denise January 2002 (has links)
Made available in DSpace on 2014-06-12T17:42:06Z (GMT). No. of bitstreams: 2 arquivo6695_1.pdf: 452243 bytes, checksum: 57aa68abe10f33f9b564e4e7e6cba46c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2002 / O metanol é um importante composto orgânico presente em diversos tipos de águas residuárias, como em indústrias de polpa e papel, amido de batata e unidades de gaseificação de carvão. Algumas águas residuárias contendo metanol são descarregadas com altas temperaturas, tornando atrativa a aplicação do tratamento termofílico. Em ambiente anaeróbio, o metanol pode ser consumido por acetogênicas e metanogênicas. Em condições mesofílicas, a concentração do substrato, o pH do reator, a concentração de bicarbonato e a concentração de cobalto foram os fatores ambientais relevantes na conversão anaeróbia do metanol. Entretanto, pouco se conhece sobre a degradação de metanol em ambientes termofilicos. Dessa forma, este trabalho tem como objetivo investigar alguns fatores ambientais que podem ser importantes para o tratamento termofílico do metanol. Para isso, foram realizados experimentos contínuos e em batelada onde foram avaliados os efeitos da exposição de lodo termofílico em baixo pH, os efeitos da adição de micronutrientes e cobalto para o tratamento. Os resultados encontrados mostraram que lodo exposto a pH 4.0 por 120 dias, não causou inibição nos microrganismos acetogênicos metilotróficos e metanogênicos hidrogenotróficos, pois quando os ensaios foram realizados com pH neutro, rapidamente recuperaram suas atividades. Em contraste, as metanogênicas metilotróficas estavam praticamente inativas. Em relação ao efeito de micronutrientes, foi observado que, quando o lodo foi cultivado com micronutrientes, o reator removeu 98,7% do metanol aplicado com uma atividade metanogênica específica para metanol de 1,69 g CH4-DQO/ g SSV⋅ d. Já para o lodo cultivado com todos micronutrientes, exceto cobalto, a eficiência foi de 97,3% com atividade de 1,27 g CH4-DQO/ g SSV⋅d. Para o lodo cultivado sem a adição de micronutrientes, a eficiência do reator foi 92, 4% que resultou numa atividade específica para metanol de 0,94 g CH4/ g SSV⋅d. A concentração de ácidos graxos voláteis foi menor que 0,11 g COD/ L em todos os reatores. Os resultados obtidos indicaram que outros micronutrientes, além do cobalto, também são importantes no tratamento termofílico do metanol. Para que haja metanogênese do metanol na faixa termofílica são necessários que o pH seja neutro, a presença de bicarbonato e a adição de micronutrientes
6

Estudo da remoção de nitrogênio via nitrito e via nitrato em sistemas de lodo ativado alimentados por despejo com elevada concentração de fenol. / Study of nitrogen removal via nitrite and via nitrate in activated sludge systems fed by wastewater with high phenol concentration.

Aun, Mariana Vivolo 11 October 2007 (has links)
Efluentes com grandes concentrações de fenol e nitrogênio amoniacal apresentam grande potencial poluidor ao meio ambiente. Exemplo deste tipo de despejo é o da unidade de coqueria da indústria siderúrgica que apresenta em termos quantitativos os fenóis como os principais constituintes orgânicos. Constituintes inorgânicos também estão presentes neste tipo de despejo e são principalmente cianeto, tiocianato, sulfato e nitrogênio amoniacal, sendo que a concentração deste último pode atingir níveis de centenas de miligramas por litro. No Estado de São Paulo, para atendimento às legislações em vigor - Decreto Estadual 8468/76 e Resolução CONAMA 357/05 - em termos de nitrogênio amoniacal e fenóis, as fontes poluidoras devem atender aos limites de emissão de 20 mg N/L para nitrogênio amoniacal total e 0,5 mg C6H5OH/L para índice de fenóis, e além disso, devem atender a classificação do corpo d\'água. Após resultados bem sucedidos de pesquisas realizadas anteriormente no Departamento de Engenharia Hidráulica e Sanitária da EPUSP objetivando remoção de compostos fenólicos e nitrogênio amoniacal, presentes em uma água residuária sintética de coqueria, através de nitrificação/desnitrificação do afluente em sistemas de lodo ativado, idealizou-se a presente pesquisa objetivando promover a nitrificação/desnitrificação de um despejo similar contendo altas concentrações de fenol (1000 mg/L) e nitrogênio amoniacal (500 a 1000 mgN/L) em sistema piloto de lodo ativado de lodo único, com duas concepções distintas: parcial (\"P\") a nitrito (ou \"nitritação/desnitritação\") em um primeiro caso, somente com fonte interna de carbono para a desnitrificação, e total (\"T\") num segundo caso, com fontes interna e externa de carbono. Além disso, também foi objetivo comparar os resultados obtidos do sistema piloto \"P\" com um sistema em bateladas seqüenciais operado paralelamente para remoção de nitrogênio via nitrito. A pesquisa permitiu concluir que o sistema contínuo, em virtude de seu regime operacional, não foi eficiente para remoção de nitrogênio via nitrito por não favorecer a manutenção de amônia livre na fase aeróbia em concentrações inibitórias aos microrganismos oxidadores de nitrito, já que segundo os resultados satisfatórios do sistema em bateladas seqüenciais, a existência de amônia livre e o pH se mostraram os principais parâmetros que regem o acúmulo de nitrito no reator. Apesar disso, o sistema apresentou resultados satisfatórios quanto à desnitrificação com fenol como fonte de carbono sendo que, durante toda a operação do sistema, o efluente final apresentou concentrações de fenol desprezíveis. Resumindo, o sistema contínuo só se mostrou adequado para remoção de nitrogênio via nitrato, ao passo que o sistema em batelada favoreceu a remoção via nitrito. Quanto ao sistema \"T\", que visava nitrificação/desnitrificação completa com fontes interna e externa de carbono, os resultados permitiram concluir que, apesar do etanol ser utilizado com eficiência pelas bactérias heterotróficas para promover a desnitrificação, seu uso como fonte externa de carbono não foi adequado em sistema de lodo único. Isto porque os microrganismos deixaram de utilizar o fenol na desnitrificação passando a utilizar somente o etanol, provocando acúmulo de fenol e desequilíbrio do sistema. Sendo assim, concluiu-se que o uso de etanol como fonte externa de carbono para a desnitrificação só seria recomendável em reator anóxico em separado, ou seja, em sistema de dois lodos e não de lodo único, como o da presente pesquisa. / Wastewaters containing high phenol and ammonium concentrations present a great pollutant potential to the environment. An example of this kind of effluent is the discharge of coke-plants, which presents, quantitatively, the phenols as the main organic compound. Inorganic compounds are also present in these wastewaters and are mainly cyanide, thiocyanate, sulphate and ammonium, the last one being able to achieve hundreds of milligrammes per litre. In Sao Paulo State, there are two legislations to be accomplished, State Decree 8468/76 and CONAMA Resolution 357/05 that stand that the polluters must accomplish the discharge limits of 20 mg N/L to total ammonium nitrogen and 0,5 mg C6H5OH/L to phenols, as well as accomplish the waterbody classification. The present research was planned after well succeded results of former researches in EPUSP\'s Hydraulic and Sanitation Engineering Department aiming to remove phenolic compounds and ammonium from a synthetic coke-plant wastewater, by nitrification/denitrification of the influent in activated sludge plants. The main purpose of this work was to remove nitrogen of a similar wastewater containing high phenol (1000 mg/L) and ammonium (500 a 1000 mgN/L) concentrations in two activated sludge pilot plants (single sludge): a partial one (\"P\") to remove nitrite (or \"nitritation/denitritation\") in the first case, only with internal carbon source for the denitrification, and a total one (\"T\") in a second case, with internal and external carbon sources. It was also aim of this work to compare the results obtained by the Partial (\"P\") pilot system with a parallel batch sequence reactor operated to remove nitrogen via nitrite. The research concluded that the continuos system, due to its operational characteristic, was not efficient to remove nitrogen via nitrite that does not favor the maintenance of free ammonia in the oxic phase in inhibitory concentrations to the nitrite oxidizers, as according to the wellsucceeded batch system, the existance of free ammonia and the pH have been the main parameters to raise the nitrite accumulation in the reactor. Nevertheless, the system presented satisfactory results to the denitrification with phenol as carbon source and, during the whole experimental work, the final effluent just showed despicable phenol concentrations. Summing up, continuos system was just adequate to remove nitrogen via nitrate, while the batch system favored its removal via nitrite. Due to the Total (\"T\") system which aims to complete nitrification/denitrification with internal and external carbon sources, the results showed that, despite ethanol having been successfully used by the heterotrophic bacteria to denitrification, its use as external carbon source was not adequate in single sludge system, because the microorganisms do not use phenol in denitrification, just using ethanol, causing phenol accumulation and unbalance of the system. Therefore, it was concluded that the use of ethanol as external carbon source to denitrification would be recommended only in anoxic separated reactor, i.e., in a double sludge system and not in a single sludge one, as this research.
7

Padrão quali-quantitativo do descarte de águas residuárias em áreas carentes: um estudo no Alto do Bom Viver em Salvador.

Assunção, Dilma Maria Santos January 2005 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2013-04-11T15:42:34Z No. of bitstreams: 1 Dilma.pdf: 7226288 bytes, checksum: 9f18d82cc7f0093b4276e7317a5ea5af (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-04-13T19:57:17Z (GMT) No. of bitstreams: 1 Dilma.pdf: 7226288 bytes, checksum: 9f18d82cc7f0093b4276e7317a5ea5af (MD5) / Made available in DSpace on 2013-04-13T19:57:17Z (GMT). No. of bitstreams: 1 Dilma.pdf: 7226288 bytes, checksum: 9f18d82cc7f0093b4276e7317a5ea5af (MD5) Previous issue date: 2005 / Discorre-se sobre o volume de água residuária, expresso em lâmina, descartado pela população que ocupa alguns dos assentamentos carentes ocorrentes nas partes altas das encostas e taludes de corte de Salvador. Utiliza-se para tal, como exemplo, um sítio do Subúrbio Ferroviário de Salvador conhecido como Alto da Boa Vista do Lobato. Em geral, tais assentamentos dispõem de abastecimento de água mas não dispõem de sistemas de esgotamento. Como consequência, as águas consumidas pela população retornam exoravelmente ao ambiente e são descartadas de modo concentrado e não disciplinado em um ou dois pontos da crista do talude. Discorre-se também, de um modo geral, acerca da taxa de ocupação de assentamentos que iguala ou faz essa lâmina superar a lâmina anual total precipitada pela chuva. Em adição, compara-se quantitativamente e se realça as diferenças associadas à intensidade, à duração e à freqüência das lâminas precipitadas pela ocupação e pela chuva. Conclui-se que as lâminas anuais descartadas pela população são surpreendentemente elevadas, comparáveis às precipitações pluviométricas e,quando o lote unidomiciliar alcança ou é inferior a cerca de 70 a 100 metros quadrados, a lâmina descartada pela população iguala-se ou supera a precipitação pluviométrica - a depender do ano hidrológico. Apoiando-se em conceitos relacionados à hidrologia e à infiltração, bservou-se que, em períodos de baixa precipitação pluviométrica, a lâmina diária gerada pela população que infiltra no subsolo tende a ser menor que a evapotranspiração. Já nos períodos de chuva intensa esta lâmina tende a ser da ordem do centésimo das lâminas geradas pelas chuvas intensas, portanto desprezível. Em ambos os períodos, as vazões geradas pela população e descartadas nas cristas dos taludes, de modo concentrado e pontual, são muito baixas em termos absolutos e desprezíveis quando comparadas às vazões geradas pela chuva. Não alcançam valores capazes de sobrecarregar os sistemas rudimentares de drenagem existentes, ou gerar erosões nas faces dos taludes, ou inundar as partes baixas do relevo. Podem, entretanto, infiltrar-se sistemática e continuamente por pontos da face do talude, sobretudo se o mesmo tiver sido cortado e exposto camadas subjacentes mais permeáveis, tal como ocorre nas encostas de solos residuais que são antropizadas por toda a cidade, criando pré-condições favoráveis à ocorrência de escorregamentos. / Salvador
8

Estudo da remoção de nitrogênio via nitrito e via nitrato em sistemas de lodo ativado alimentados por despejo com elevada concentração de fenol. / Study of nitrogen removal via nitrite and via nitrate in activated sludge systems fed by wastewater with high phenol concentration.

Mariana Vivolo Aun 11 October 2007 (has links)
Efluentes com grandes concentrações de fenol e nitrogênio amoniacal apresentam grande potencial poluidor ao meio ambiente. Exemplo deste tipo de despejo é o da unidade de coqueria da indústria siderúrgica que apresenta em termos quantitativos os fenóis como os principais constituintes orgânicos. Constituintes inorgânicos também estão presentes neste tipo de despejo e são principalmente cianeto, tiocianato, sulfato e nitrogênio amoniacal, sendo que a concentração deste último pode atingir níveis de centenas de miligramas por litro. No Estado de São Paulo, para atendimento às legislações em vigor - Decreto Estadual 8468/76 e Resolução CONAMA 357/05 - em termos de nitrogênio amoniacal e fenóis, as fontes poluidoras devem atender aos limites de emissão de 20 mg N/L para nitrogênio amoniacal total e 0,5 mg C6H5OH/L para índice de fenóis, e além disso, devem atender a classificação do corpo d\'água. Após resultados bem sucedidos de pesquisas realizadas anteriormente no Departamento de Engenharia Hidráulica e Sanitária da EPUSP objetivando remoção de compostos fenólicos e nitrogênio amoniacal, presentes em uma água residuária sintética de coqueria, através de nitrificação/desnitrificação do afluente em sistemas de lodo ativado, idealizou-se a presente pesquisa objetivando promover a nitrificação/desnitrificação de um despejo similar contendo altas concentrações de fenol (1000 mg/L) e nitrogênio amoniacal (500 a 1000 mgN/L) em sistema piloto de lodo ativado de lodo único, com duas concepções distintas: parcial (\"P\") a nitrito (ou \"nitritação/desnitritação\") em um primeiro caso, somente com fonte interna de carbono para a desnitrificação, e total (\"T\") num segundo caso, com fontes interna e externa de carbono. Além disso, também foi objetivo comparar os resultados obtidos do sistema piloto \"P\" com um sistema em bateladas seqüenciais operado paralelamente para remoção de nitrogênio via nitrito. A pesquisa permitiu concluir que o sistema contínuo, em virtude de seu regime operacional, não foi eficiente para remoção de nitrogênio via nitrito por não favorecer a manutenção de amônia livre na fase aeróbia em concentrações inibitórias aos microrganismos oxidadores de nitrito, já que segundo os resultados satisfatórios do sistema em bateladas seqüenciais, a existência de amônia livre e o pH se mostraram os principais parâmetros que regem o acúmulo de nitrito no reator. Apesar disso, o sistema apresentou resultados satisfatórios quanto à desnitrificação com fenol como fonte de carbono sendo que, durante toda a operação do sistema, o efluente final apresentou concentrações de fenol desprezíveis. Resumindo, o sistema contínuo só se mostrou adequado para remoção de nitrogênio via nitrato, ao passo que o sistema em batelada favoreceu a remoção via nitrito. Quanto ao sistema \"T\", que visava nitrificação/desnitrificação completa com fontes interna e externa de carbono, os resultados permitiram concluir que, apesar do etanol ser utilizado com eficiência pelas bactérias heterotróficas para promover a desnitrificação, seu uso como fonte externa de carbono não foi adequado em sistema de lodo único. Isto porque os microrganismos deixaram de utilizar o fenol na desnitrificação passando a utilizar somente o etanol, provocando acúmulo de fenol e desequilíbrio do sistema. Sendo assim, concluiu-se que o uso de etanol como fonte externa de carbono para a desnitrificação só seria recomendável em reator anóxico em separado, ou seja, em sistema de dois lodos e não de lodo único, como o da presente pesquisa. / Wastewaters containing high phenol and ammonium concentrations present a great pollutant potential to the environment. An example of this kind of effluent is the discharge of coke-plants, which presents, quantitatively, the phenols as the main organic compound. Inorganic compounds are also present in these wastewaters and are mainly cyanide, thiocyanate, sulphate and ammonium, the last one being able to achieve hundreds of milligrammes per litre. In Sao Paulo State, there are two legislations to be accomplished, State Decree 8468/76 and CONAMA Resolution 357/05 that stand that the polluters must accomplish the discharge limits of 20 mg N/L to total ammonium nitrogen and 0,5 mg C6H5OH/L to phenols, as well as accomplish the waterbody classification. The present research was planned after well succeded results of former researches in EPUSP\'s Hydraulic and Sanitation Engineering Department aiming to remove phenolic compounds and ammonium from a synthetic coke-plant wastewater, by nitrification/denitrification of the influent in activated sludge plants. The main purpose of this work was to remove nitrogen of a similar wastewater containing high phenol (1000 mg/L) and ammonium (500 a 1000 mgN/L) concentrations in two activated sludge pilot plants (single sludge): a partial one (\"P\") to remove nitrite (or \"nitritation/denitritation\") in the first case, only with internal carbon source for the denitrification, and a total one (\"T\") in a second case, with internal and external carbon sources. It was also aim of this work to compare the results obtained by the Partial (\"P\") pilot system with a parallel batch sequence reactor operated to remove nitrogen via nitrite. The research concluded that the continuos system, due to its operational characteristic, was not efficient to remove nitrogen via nitrite that does not favor the maintenance of free ammonia in the oxic phase in inhibitory concentrations to the nitrite oxidizers, as according to the wellsucceeded batch system, the existance of free ammonia and the pH have been the main parameters to raise the nitrite accumulation in the reactor. Nevertheless, the system presented satisfactory results to the denitrification with phenol as carbon source and, during the whole experimental work, the final effluent just showed despicable phenol concentrations. Summing up, continuos system was just adequate to remove nitrogen via nitrate, while the batch system favored its removal via nitrite. Due to the Total (\"T\") system which aims to complete nitrification/denitrification with internal and external carbon sources, the results showed that, despite ethanol having been successfully used by the heterotrophic bacteria to denitrification, its use as external carbon source was not adequate in single sludge system, because the microorganisms do not use phenol in denitrification, just using ethanol, causing phenol accumulation and unbalance of the system. Therefore, it was concluded that the use of ethanol as external carbon source to denitrification would be recommended only in anoxic separated reactor, i.e., in a double sludge system and not in a single sludge one, as this research.
9

Avaliação da eficiência de um sistema de tratamento de efluente hospitalar por processo anaeróbio na remoção de coliformes, Pseudomonas aeruginosa, Klebsiella pneumoniae resistentes a antibióticos e Vírus da Hepatite A / Evaluation of the efficiency of a system of handling of efluente hospital by trial anaeróbio in the removal of coliformes, Pseudomonas aeruginosa, Klebsiella pneumoniae resistant to antibiotic and Virus of the Hepatitis A

Prado, Tatiana January 2007 (has links)
Made available in DSpace on 2012-09-06T01:11:34Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 925.pdf: 4327495 bytes, checksum: 2ac1e3c8c4ff6b52a165f9a04e3937d8 (MD5) Previous issue date: 2007 / O presente trabalho abrange a discussão sobre as características microbiológicas de esgotos hospitalares, bem como os impactos do lançamento destes efluentes sem um prétratamento adequado em corpos receptores, cujos riscos associados incluem a disseminação de microrganismos patogênicos no ambiente. Desta forma, estudou-se a eficiência de um sistema de tratamento de esgoto hospitalar localizado na cidade do Rio de Janeiro, para verificar se o mesmo era capaz de eliminar coliformes totais e fecais, Pseudomonas aeruginosa, Klebsiella pneumoniae resistentes a antibióticos e vírus da hepatite A. O sistema experimental se constitui de uma unidade de reator UASB seguido de pós-tratamento por três filtros anaeróbios dispostos em série, conferindo-lhe uma característica particular. Também teve como meta a verificação da adequação de uma técnica para detectar vírus da hepatite A em amostras de esgoto e lodo de esgoto. Concluiu-se que o sistema de tratamento estudado não foi capaz de eliminar os coliformes totais e fecais, Pseudomonas aeruginosa e bactérias resistentes do efluente tratado. Entretanto, nenhum vírus da hepatite A foi detectado no efluente final tratado, indicando que este sistema pode ser eficiente na remoção de vírus patogênicos. (...) Estes resultados confirmam a emergência do problema da alta prevalência de bactérias resistentes a antibióticos nos hospitais, bem como em amostras ambientais.
10

Tratamento de despejo de coqueria via nitritação/desnitritação operando um sistema de lodo ativado em bateladas sequenciais. / Coke-oven wastewater treatment over nitritation/denitritation in an activated sludge sequencing batch reactor.

Queiroz, Luciano Matos 19 June 2009 (has links)
A presente pesquisa objetivou estudar a remoção dos poluentes presentes em uma água residuária de coqueria, através do processo biológico de nitritação/desnitritação operando um reator de lodo ativado em bateladas seqüenciais em duas etapas sucessivas. Durante a primeira, o reator foi alimentado com um efluente sintético composto por dois poluentes abundantes em despejos de coqueria: nitrogênio amoniacal (500 mg N/L) e fenol (1.000 mg C6H5OH/L). Na segunda, o reator foi alimentado com o despejo gerado na unidade de coqueria de uma indústria siderúrgica integrada. Ao longo da primeira etapa, ao final da fase aeróbia dos 28 ciclos de tratamento, foi possível alcançar eficiências de remoção de N-NH3 superiores a 90% com predominância do N-NO2 - na massa líquida do reator evidenciado pelas relações N-NO2 -/ (N-NO2 - + N-NO3 -) superiores a 86%. O principal mecanismo de inibição das bactérias oxidantes de nitrito (BON) foram concentrações de amônia livre no conteúdo do reator entre 3,2 e 19,5 mg NH3/L. As taxas específicas de nitritação variaram entre 0,03 e 0,11 kg N-NH3/ kg SSV.dia, para temperaturas no conteúdo do reator entre 15 e 34°C. Durante a fase anóxica, o fenol mostrou-se adequado como fonte de carbono para a biomassa desnitritante, desde que as taxas de aplicação volumétricas fossem inferiores a 0,02 kg fenol/m³.hora. Respeitando essa condição, foi possível alcançar: eficiências de remoção de fenol entre 45 e 56%; taxas específicas de remoção de fenol entre 0,03 e 0,09 kg C6H5OH / kg SSV.dia; taxas específicas de desnitritação entre 0,03 e 0,06 kg N-NO2 -/ kg SSV.dia e eficiências de remoção de (N-NO2 - + N-NO3 -) superiores a 95%. Ao longo da fase anóxica foram retiradas amostras do conteúdo do reator para a realização de análises de nitrofenóis (NF). Os resultados acusaram a presença de 2 nitrofenol e 4 nitrofenol em concentrações proporcionais à taxa de aplicação volumétrica do fenol na massa líquida do reator. A presença desses compostos em concentrações inferiores a 0,5 mg/L não causou impacto sobre a desnitritação biológica. As análises realizadas em amostras coletadas ao final da reação anóxica, não acusaram a presença de 2 e 4 NF, demonstrando que esses compostos podem ser biodegradados por uma biomassa bem adaptada ao fenol. A concepção do sistema para tratamento da água residuária de coqueria via nitritação/desnitritação envolveu a operação de dois reatores (principal e reator de polimento) operados em bateladas seqüenciais. As condições de operação do reator principal eram manipuladas para viabilizar o acúmulo de NNO2 - ao final da fase aeróbia e promover a desnitritação durante a fase anóxica, utilizando como fonte de carbono a própria matéria orgânica presente no despejo. Como o sobrenadante do reator principal apresentava concentrações elevadas de N-NO2 -, esse efluente era aplicado no reator de polimento, juntamente com etanol como fonte de carbono para redução do NNO2 -. Ao final da fase aeróbia dos ciclos de tratamento conduzidos no reator principal alcançaram-se: relações NO2 -/ (N-NO2 - + N-NO3 -) superiores a 88%; eficiências de remoções de nitrogênio total superiores a 60%; remoções de N-NH3 superiores a 90%, para valores de pH na massa líquida do reator entre 7,8 e 8,5 e, temperatura entre 23 e 31°C. Tal qual ocorrido durante a primeira etapa da investigação, o principal mecanismo de inibição da atividade das bactérias oxidantes de nitrito foi a toxicidade conferida pelas concentrações de amônia livre (3,7 a 15,7 mg NH3/L) no conteúdo do reator. Durante a fase anóxica, as eficiências de remoção de (N-NO2 - foram limitadas pela disponibilidade de matéria orgânica biodegradável no despejo da coqueria, razões DBO/DQOafluente superiores a 80% resultaram em remoções de N-NO2 - próximas de 100%. Quanto ao reator de polimento, pode-se afirmar que o etanol teve um efeito positivo sobre a remoção de matéria orgânica da água residuária da coqueria, considerando a configuração (dois lodos) utilizada. / The present research aimed to study the coke-oven wastewater treatment over nitritation/denitritation in an activated sludge sequencing batch reactor in two successive phases. During the first one, the reactor was fed with a synthetic effluent composed by two abundant pollutants present in coke-oven wastewaters: total ammonia nitrogen (500 mg TAN.l-1) and phenol (1,000 mg C6H5OH.l-1). During the second phase, the reactor was fed with the wastewater produced in an integrated steel industrys coke-plant. The results of the first phase (28 cycles) showed that was possible to achieve TAN removal efficiencies higher than 90% with NO2 --N predominance in the reactor content, evidenced by the rates NO2 --N/ (NO2 --N + NO3 --N) higher than 86%. The main mechanism of the nitrite oxidizer bacteria (NOB) inhibition was free ammonia concentrations between 3.2 and 19.5 mg NH3.l-1. The specific nitritation rates varied between 0.03 and 0.11 kg TAN. kg VSS-1.d-1, for temperatures between 15 and 34oC. Phenol showed to be suitable as carbon source for denitrifying biomass, once the volumetric application rates were lower than 0.02 kg phenol.m-3.h-1. Obeying this condition, it was possible to achieve: phenol removal efficiencies between 45 and 56%; specific phenol removal rates between 0.03 and 0.09 kg C6H5OH. kg VSS-1.d-1; specific denitritation rates between 0.03 and 0.06 kg NO2 --N . kg VSS-1.d-1 and removal efficiencies of (NO2 --N + NO3 --N) higher than 95%. During the anoxic phase, samples were collected from the reactor content for nitrophenols analyses. The results showed the presence of 2- nitrophenol (2-NP) and 4-nitrophenol (4-NP) in concentrations proportional to phenol volumetric application rate in the reactor liquid mass. The presence of those compounds in concentrations lower than 0.5 mg/L does not cause impact over the biological denitritation. The analyses accomplished in samples collected at the end of the anoxic reaction do not show the presence of 2 and 4-NP, demonstrating that these compounds can be biodegraded by a well-adapted biomass. The arrangement of the system for the treatment of coke-oven wastewater (Phase 02) over nitritation/denitritation involved the operation of two sequencing batch reactors (the main reactor and the polishing one). The operational conditions of the main reactor were manipulated to make feasible the NO2 --N accumulation at the end of the aerobic stage and promote the denitritation using the own organic matter present in the cokeoven wastewater as carbon source. As the supernatant of the main reactor presented high nitrite concentrations, this effluent was conducted to a biological denitrifying polishing reactor with ethanol as carbon source. At the end of the aerobic stage of the treatment cycles conducted in the main reactor, it was achieved: NO2 --N/ (NO2 --N + NO3 --N) higher than 88%; total nitrogen removal efficiencies higher than 60%; ammonia nitrogen removal higher than 90%. As occurred during the first phase of the investigation, the main NOB activity inhibition was the toxicity of the free ammonia concentrations (3.7 to 15.7 mg NH3.l-1) in the reactor content. At the end of anoxic stage, the NO2 --N removal efficiencies were limited by the availability of the biodegradable organic matter in the coke-oven wastewater but BOD/CODinfluent higher than 80% resulted in NO2 --N removals next to 100%. Regarding to the polishing reactor, it can be stated that the ethanol had a positive effect over the organic matter removal of the coke-oven wastewater.

Page generated in 0.0757 seconds