• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise de desgaste de técnicas de correção de erros em phase-change memories / Analysis of wear-out of error correction techniques in phase-change memories

Hoffman, Caio, 1983- 07 January 2013 (has links)
Orientadores: Guido Costa Souza de Araújo, Rodolfo Jardim de Azevedo / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Computação / Made available in DSpace on 2018-08-23T10:06:28Z (GMT). No. of bitstreams: 1 Hoffman_Caio_M.pdf: 5338735 bytes, checksum: d93e38ef7846b0ba3f7f3b0ea459fc67 (MD5) Previous issue date: 2013 / Resumo: Phase-change memory (PCM) traz novos ensejos para indústria eletrônica. Devido às projeções de alta escalabilidade do processo de fabricação da PCM, cogita-se usá-la como memória principal em sistemas de computação, substituindo à tradicional DRAM cujos problemas de miniaturização do processo de fabricação demandam tecnologias ainda desconhecidas. Contudo, PCM tem problemas de durabilidade e técnicas de recuperação de falhas robustas são extremamente necessárias para recuperação e prolongamento do seu tempo de vida, medido em número de escritas. As técnicas mais comuns de recuperação de falhas são os códigos de correção de erros. Porém, outras técnicas de recuperação vêm sendo propostas na literatura, aproveitando as características de não-volatilidade da PCM. Neste trabalho, usando uma modelagem matemática, analisou-se como a probabilidade de bit-ip dos principais códigos de correção de erros { paridade, SECDED e BCH { e das principais técnicas de recuperação de falhas { ECP e SAFER { está relacionada _a durabilidade da PCM. A partir da taxa de bit-ip medida através da execução do SPEC2006 e por meio dos modelos matemáticos, comparou-se os resultados dos modelos de simulação utilizando-se a probabilidade teórica de 50% e a taxa obtida experimentalmente de 15%. Os resultados revelaram uma visível degradação da durabilidade dos mecanismos de recuperação de falhas que usam códigos de correção de erros, contradizendo os resultados da literatura. A técnica ECP foi à única que não mostrou degradação. Além disso, uma análise de eficiência energética foi feita, relacionando durabilidade da PCM e o consumo de energia. Novamente, a técnica ECP se destacou nos resultados, como também a técnica SAFER. Finalmente, foram propostos modelos analíticos probabilísticos das técnicas ECP, SECDED e uma análise da técnica PAYG baseada no modelo analítico da ECP / Abstract: Phase-change memory brings new opportunities for the electronics industry. Due to projections of high scalability of the fabrication process, PCM is seen as a new main memory in computing systems, replacing the traditional DRAM, whose scale problems require new future technologies that are still unknown. However, PCM has low endurance when compared with DRAM and robust failure recovery techniques are required to increase its lifetime. To address that, some error correcting techniques have been proposed, based on the non-volatile features of the PCM memories. In this work, we model and analyze the bit-ip probabilities of five such techniques (ECP, parity, SECDED, SAFER and BCH), in order to evaluate its impact to the wear out of the PCM. Using the bit-ip rate of 15%, obtained experimentally from the execution of the SPEC2006 benchmark, we mathematically modeled and simulated these techniques using both an empirical and theoretical probability rates. Our results show a clear degradation in techniques that use error-correcting codes, contradicting the previous results in the literature. Only ECP has not shown any degradation. We have also done power analyses of the above listed techniques so as to relate the endurance and the energy required by each technique. Again, the ECP stood out in the results, like SAFER as well. Finally, analytical probabilistic models for ECP and SECDED were proposed and an analysis of PAYG technique (based on ECP's analytical model) was performed / Mestrado / Ciência da Computação / Mestre em Ciência da Computação
2

RPCs design, development and tests for the Pierre Auger Observatory / Desenvolvimento, construção e testes de RPCs para o observatório Pierre Auger

Martins, Victor Barbosa 20 August 2018 (has links)
The cosmic rays are the most energetic particles in the universe. Their production, propagation, and detection are objects of studies. Surface detectors aim to identify particles from extensive air showers (EAS) which the result from the cosmic-ray interactions with the atmosphere. Resistive Plate Chambers (RPCs) have shown to be a suitable muon detector to be integrated into the Pierre Auger Observatory. An instrumentation was developed to assembly RPCs in São Carlos (BRA). Data from RPCs already built by our collaborators in Coimbra (POR) were analyzed. The detector efficiency to muons was calculated and is approximately 88%, which is in good agreement with the values quoted in the literature. Direction maps were built to investigate the muon incoming direction and the quantity of matter traversed by the muons. The dependence of the muon flux on the zenith angle was calculated and compared with results from the simulation. A square cosine dependence is expected, though it is seen that the building structure has enough matter to block some of the incident muons and alter the dependence curve. The total muon flux was estimated based on the detector efficiencies and solid angle as 1.6.10−5. mm−2.sr−1. s−1 compared with the literature value of 7.1.10−5 mm−2.sr−1.s−1, which gives an absorption by the building of approximately 77%. / Os raios cósmicos são as partículas mais energéticas do universo. Sua produção, propagação e detecção são objetos de estudos. Os detectores de superfície têm como objetivo identificar partículas dos chuveiros atmosféricos extensos (EAS), o qual é o resultado das interações do raio cósmico com a atmosfera. A Câmaras de Placas Resistivas (RPCs) demonstra ser um detector de múons adequado para ser integrado ao Observatório Pierre Auger. Foi desenvolvida em São Carlos (BRA) uma instrumentação para montagem de RPCs. Dados de RPCs já construídas por nossos colaboradores em Coimbra (POR) foram analisados. A eficiência dos detectores para múons foi calculada como sendo de aproximadamente 88%, o que está de acordo com os valores citados na literatura. Mapas de direção foram construídos para investigar a direção de chegada e a quantidade de matéria atravessada pelos múons. A dependência do fluxo de múons com o ângulo zenital foi comparada com os resultados da simulação. Embora uma dependência com o quadrado do cosseno é esperada, foi constatado que a estrutura do prédio tem matéria suficiente para bloquear parte dos múons incidentes e alterar a curva da dependência. O fluxo total de múons foi estimado baseado nas eficiências do detector e no ângulo sólido é de 1.6.10−5 mm−2.sr−1.s−1. Comparado com o valor da literatura de 7.1.10−5 mm−2.sr−1.s−1 resulta em uma absorção pelo prédio de aproximadamente 77% do fluxo de múons.
3

RPCs design, development and tests for the Pierre Auger Observatory / Desenvolvimento, construção e testes de RPCs para o observatório Pierre Auger

Victor Barbosa Martins 20 August 2018 (has links)
The cosmic rays are the most energetic particles in the universe. Their production, propagation, and detection are objects of studies. Surface detectors aim to identify particles from extensive air showers (EAS) which the result from the cosmic-ray interactions with the atmosphere. Resistive Plate Chambers (RPCs) have shown to be a suitable muon detector to be integrated into the Pierre Auger Observatory. An instrumentation was developed to assembly RPCs in São Carlos (BRA). Data from RPCs already built by our collaborators in Coimbra (POR) were analyzed. The detector efficiency to muons was calculated and is approximately 88%, which is in good agreement with the values quoted in the literature. Direction maps were built to investigate the muon incoming direction and the quantity of matter traversed by the muons. The dependence of the muon flux on the zenith angle was calculated and compared with results from the simulation. A square cosine dependence is expected, though it is seen that the building structure has enough matter to block some of the incident muons and alter the dependence curve. The total muon flux was estimated based on the detector efficiencies and solid angle as 1.6.10−5. mm−2.sr−1. s−1 compared with the literature value of 7.1.10−5 mm−2.sr−1.s−1, which gives an absorption by the building of approximately 77%. / Os raios cósmicos são as partículas mais energéticas do universo. Sua produção, propagação e detecção são objetos de estudos. Os detectores de superfície têm como objetivo identificar partículas dos chuveiros atmosféricos extensos (EAS), o qual é o resultado das interações do raio cósmico com a atmosfera. A Câmaras de Placas Resistivas (RPCs) demonstra ser um detector de múons adequado para ser integrado ao Observatório Pierre Auger. Foi desenvolvida em São Carlos (BRA) uma instrumentação para montagem de RPCs. Dados de RPCs já construídas por nossos colaboradores em Coimbra (POR) foram analisados. A eficiência dos detectores para múons foi calculada como sendo de aproximadamente 88%, o que está de acordo com os valores citados na literatura. Mapas de direção foram construídos para investigar a direção de chegada e a quantidade de matéria atravessada pelos múons. A dependência do fluxo de múons com o ângulo zenital foi comparada com os resultados da simulação. Embora uma dependência com o quadrado do cosseno é esperada, foi constatado que a estrutura do prédio tem matéria suficiente para bloquear parte dos múons incidentes e alterar a curva da dependência. O fluxo total de múons foi estimado baseado nas eficiências do detector e no ângulo sólido é de 1.6.10−5 mm−2.sr−1.s−1. Comparado com o valor da literatura de 7.1.10−5 mm−2.sr−1.s−1 resulta em uma absorção pelo prédio de aproximadamente 77% do fluxo de múons.

Page generated in 0.0734 seconds