• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Fast waveform metrology : generation, measurement and application of sub-picosecond electrical pulses

Smith, Andrew James Alan January 1996 (has links)
This thesis describes work performed at the National Physical Laboratory to improve the electrical risetime calibration of instruments such as fast sampling oscilloscopes. The majority of the work can be divided into four sections: development of an ultrafast optoelectronic pulse generator; measurement of fast electrical pulses with an electrooptic sampling system; de-embedding of transmission line and transition effects as measured at different calibration reference planes; and calibration of an oscilloscope. The pulse generator is a photoconductive switch based on low-temperature Gallium Arsenide, which has a very fast carrier recombination time. Sub-picosecond electrical pulses are produced by illuminated a planar switch with 200 fs optical pulses from a Ti: sapphire laser system. The pulses are measured using a sampling system with an external electro-optic probe in close proximity to the switch. The electro-optic sampling system, with a temporal resolution better than 500 fs, is used to measure the electrical pulses shape at various positions along the planar transmission line. The results are compared to a pulse propagation model for the line. The effects of different switch geometries are examined. Although the pulse generator produces sub-picosecond pulses near to the point of generation, the pulse is shown to broaden to 7 ps after passing along a length of transmission line and a coplanar-coaxial transition. For a sampling oscilloscope with a coaxial input connector, this effect is significant. Frequency-domain measurements with a network analyser, further electro-optic sampling measurements, and the transmission line model are combined to find the network transfer function of the transition. Using the pulse generator, the electro-optic sampling system and the transition knowledge, a 50 GHz sampling oscilloscope is calibrated. The determination of the instrument step response(nominal risetime 7 ps) is improved from an earlier value of 8.5 -3.5 / +2.9 ps to a new value of 7.4 -2.1 / +1.7 ps with the calibration techniques described.
2

Design and Modeling of Schottky Barrier Photodiodes

Joseph, Wai-Ting 04 1900 (has links)
<p>The computer program developed by T.B. Remple for the analysis of PiN photodiodes has been modified to handle Schottky barrier cases. The fundamental physics involved in the original model is summarized and the theories for a metal-semiconductor interface are presented. The boundary values for n, p, and ψ are then defined in such a way that ψ (x) would be in agreement with the thermionic-diffusion theory. An equivalent circuit approach is used to determine the RC response of the photodetector. While the modified version of the computer model provides very detailed analysis of the device, it is also very expensive to run. A simplified model is therefore employed for the design process. The objective is to design an Au-nGe photodiode with a risetime less than 50 psecs. The set of optimum design parameters obtained with the simplified model is then taken as the input to the modified version of Remple's program for further analysis. The theoretical risetime of the optimum design is found to be about 45 psecs.</p> / Thesis / Master of Engineering (ME)

Page generated in 0.029 seconds