• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 4
  • 1
  • Tagged with
  • 8
  • 5
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An in situ kinetic investigation of the selective dissolution mechanism of Cu alloys / Une étude cinétique in situ du mécanisme de dissolution sélective des alliages de Cu

Zhou, Peng 13 October 2017 (has links)
Les mécanismes de dissolution sélective des alliages de Cu dans l'eau du robinet et la solution de transpiration ont été étudiés. La spectroélectrochimie d'émission atomique a été utilisée. La première partie de la thèse portait sur le mécanisme de dissolution de Cu. La plupart des espèces de Cu (II) sont solubles et sont libérées dans l'eau, laissant derrière eux un film de Cu2O. Une analyse cinétique suggère que le mécanisme de dissolution implique la dissolution simultanée du Cu et la formation du film. La deuxième partie a étudié la dissolution de Cu-42Zn et Cu-21Zn-3Si-P. Un processus de dissolution en deux étapes a été proposé: une première étape d'une croissance rapide de la couche dézincitée et une deuxième étape où la croissance de la couche dézincitée était plus lente. La troisième partie s'est concentrée sur l'effet du contenu de Zn sur la dissolution des alliages de Cu-Zn. Le mécanisme de dissolution a été clarifié. Pour la phase ?: une étape initiale dans laquelle Cu et Zn sont oxydés de manière congruente, mais seulement Zn2+ a été libéré dans l'eau, Cu formant un film Cu2O et une deuxième étape où le Cu2+ a été libéré dans l'eau. Pour la phase ?', la deuxième étape est identique à la phase initiale. L'augmentation de la teneur en Zn entraîne une extension temporelle du stade initial et retardent la libération de Cu2+. La partie finale a porté sur l'effet de la libération de Sn on Cu provenant des alliages Cu-Sn. L'effet amélioré de la libération de Sn sur Cu a été identifié. Cependant, l'augmentation de la teneur en Sn n'a pas augmenté monotoniquement l'efficacité de libération de Cu des alliages de Cu-Sn, ce qui était dû à la passivité de Sn. / The selective dissolution mechanisms of Cu alloys in tap water and perspiration solution were investigated. Atomic emission spectroelectrochemistry (AESEC) was used to obtain the elemental dissolution kinetics. The first part of the thesis focused on the dissolution mechanism of Cu. Most Cu(II) species are soluble and are released into tap water, leaving behind a Cu2O film on the surface. A kinetic analysis suggests that the dissolution mechanism involves simultaneous Cu dissolution and film formation. The second part investigated the dissolution behavior of Cu-42Zn and Cu-21Zn-3Si-P. A two-stage dissolution process of dezincification was proposed: a first stage of a rapid growth of the dezincified layer and a second stage where the growth of dezincified layer was much slower. The third part concentrated on the effect of Zn content on the dissolution of Cu-Zn alloys, by investigating the dissolution behavior of alloys with various Zn content (0-45 wt%). The two-stage dissolution mechanism was further clarified. For α phase: an initial stage in which Cu and Zn are oxidized congruently, but only Zn2+ was released into water, Cu forming a Cu2O film, and a second stage where Cu was released into water in the form of Cu2+. For β' phase, the second stage is the same to the initial stage. The increase of Zn content in the alloy results in a time extension of the initial stage and retard Cu2+ release. The final part focused on the effect of Sn on Cu release from Cu-Sn alloys. The enhanced effect of Sn on Cu release was identified. However, the increase of Sn content didn’t monotonically increase the Cu release efficacy of Cu-Sn alloys, which was due to the passivity of Sn.
2

Un schéma aux volumes finis avec matrice signe pour les systèmes non homogènes

SAHMIM, Slah 15 June 2005 (has links) (PDF)
Cette thèse est consacrée à l'analyse, à l'application et à l'extension bidimensionnelle, d'un nouveau schéma aux volumes finis (SRNH) proposé récemment pour une classe de système non homogène. L'analyse de stabilité du schéma, d'abord dans le cas scalaire ensuite dans le cas de systèmes, mène à une nouvelle formulation où intervient le signe de la matrice Jacobienne du système de lois de bilan considéré. Pour le système de Saint Venant avec terme de pente, on montre formellement que le schéma SRNHS vérifie la C-propriété exacte introduite pour les schémas équilibres par Bermùdez et Vázquez. Les résultats numériques 1D et 2D, en particulier du cas de rupture de barage sur un fond en forme de marche, montrent le degrés d'efficacité du schéma. Pour le système diphasiques des zones de non hyperbolicité peuvent exister, avec apparition de valeurs propres complexes dans la Jacobienne du système. On montre que pour les configurations faiblement non hyperboliques, on peut calculer le signe de la Jacobienne par l'algorithme de Newton-Schultz. Pour les configurations plus raides, où la méthode précédente ne fonctionne plus, on a recours à la méthode de perturbation par densité. Dans les deux cas évoqués, les tests numériques montrent que l'on approche la solution exacte du problème de Ransom avec une grande précision, et que l'on conserve la stabilité des calculs même avec un maillage de finesse relativement élevée.
3

Simulation numérique en volume finis, de problèmes d'écoulements multidimensionnels raides, par un schéma de flux à deux pas

MOHAMED, Kamel 12 October 2005 (has links) (PDF)
Cette thèse est consacrée à la simulation numérique de problèmes d'écoulements de fluides raides régis par des systèmes de lois de bilan non homogènes, dans des configurations monodimensionnelles et bidimensionnelles. La méthode numérique utilisée est une extension d'un schéma à deux pas (SRNH), comportant un paramètre \alpha^n_(j+\frac(1)(2)) ajustable, proposé par le professeur F.Benkhaldoun dans un cadre monodimensionnel. Ainsi, en un premier temps on a introduit une variante SRNHR, obtenue en remplaçant la vitesse numérique (\frac(\Delta x)(\Delta t)) par la vitesse de Rusanov locale, en vue de l'extension du schéma au cas bidimensionnel. Par la suite, une analyse de stabilité du schéma, révèle que celui-ci peut être d'ordre 1 ou 2 selon la valeur du paramètre \alpha^n_(j+\frac(1)(2)). Une stratégie de variation de ce paramètre, basée sur la théorie des limiteurs a alors été adoptée. Le schéma peut ainsi être rendu d'ordre 1 dans les zones à forte variation de l'écoulement, et d'ordre 2, là où l'écoulement est régulier. Ensuite on a établi les conditions pour que ce schéma respecte la C-propriété exacte introduite par Bermùdez et Vazquez. Une étude d'implémentation des conditions aux limites, adaptée à ce schéma, a également été menée en se basant sur les invariants de Riemann. Dans la deuxième partie de la thèse, on a appliqué ce schéma à des systèmes monophasiques homogènes et non homogènes. Par exemple on a réalisé la simulation du problème de rupture de barrage sur une marche, pour des configurations 1D et 2D, en menant en particulier une étude de convergence numérique via la détermination des courbes d'erreurs. Enfin, on a utilisé le schéma pour la simulation numérique de systèmes diphasiques (Ransom 1D et 2D).
4

Analyse de la transmission des sollicitations tribologiques dans un presse-garnitures de robinet pour en maîtriser l’effort de manœuvre et l’étanchéité / An analysis of the transmission of tribological stress in the compression packing of a valve to control the force to move the stem and the quality of sealing

Ho, Xiao Joe 03 October 2013 (has links)
Depuis plus de 150 ans, le presse-garnitures (ou presse-étoupes) est le moyen le plus simple de réaliser l’étanchéité d’un robinet tout en permettant le mouvement de la tige pour ouvrir/fermer le robinet. C’est aussi la principale cause de fuites sur un robinet. Malgré l’utilisation de garnitures en graphite expansé qui réduit de manière significative le nombre de fuites, des problèmes comme l’augmentation de l’effort de manœuvre de la tige y ont été aussi associés. L’amélioration de l’étanchéité tout en réduisant l’effort de manœuvre de la tige est constamment recherchée sur un presse-garnitures de robinet afin d’optimiser industriellement. Pour atteindre cet objectif, le presse-garnitures est au cœur des études scientifiques et industrielles depuis 1957. Toutes les études identifiées dans la littérature ne permettent pas de maîtriser l’étanchéité et l’effort de manœuvre puisqu’elles ne prennent pas en compte le troisième corps présent dans le contact tige-garnitures lors des manœuvres de la tige. Les travaux de cette thèse proposent alors d’étudier le comportement tribologique du contact tige-garnitures. La démarche adoptée nécessite d’identifier les conditions de contact, ce qui est difficile par une instrumentation directe. Il faut donc reconstituer ces conditions par le couplage entre une approche expérimentale et une approche numérique. L’approche expérimentale est utilisée pour reproduire les conditions du contact tige-garnitures sur un banc d’essai simulant le fonctionnement d’un robinet à l’échelle 1:1. Afin d’améliorer la compréhension du comportement tribologique, des caractérisations tribologiques ont été réalisées sur la tige et les garnitures en graphite expansé après essai. Ainsi, elles ont permis de définir le circuit tribologique du contact tige-garnitures, qui contrôle à la fois l’étanchéité autour de la tige et l’effort de manœuvre. En effet, les débits du troisième corps contrôlent l’étanchéité tandis que le mécanisme d’accommodation de vitesse du troisième corps par cisaillement contrôle l’effort de manœuvre. Afin de compléter l’analyse expérimentale précédente, une approche numérique a été utilisée par l’intermédiaire d’un modèle par éléments finis. Le modèle permet d’évaluer la qualité d’étanchéité d’un presse-garnitures, vis-à-vis de la pression du fluide à étancher. De plus, l’influence du frottement aux interfaces tige-garnitures et boîte-garnitures sur l’étanchéité et l’effort de manœuvre est mise en évidence par l’intermédiaire d’une étude de sensibilité. Les travaux de cette thèse permettent l’appréciation de l’importance de prendre en compte l’influence du troisième corps dans un contact. Dans le cas d’un presse-garnitures, le troisième corps dans le contact tige-garnitures modifie des conditions de contact et celles-ci influent à leur tour l’étanchéité autour de la tige et l’effort de manœuvre. / For over 150 years, compression packing has been the simplest method of sealing a valve while allowing movement of the stem to move to open or close the valve. It is also the major source of valve leakage. Despite the use of flexible graphite packing, which reduces significantly the number of valve leakage incidents, it leads to other problems such as the increasing force required to cycle the stem. Improvement in quality of sealing while decreasing force required to cycle the stem is required in a valve compression packing in order to optimize the industrial system. To achieve this objective, compression packing has been a topic of scientific and industrial research since 1957. All published research does not allow to control the sealing quality and the force required the cycle the stem as it takes no account of the third body in the stem-packing contact while the stem moves. Thus, the work of this thesis designed to investigate the tribological behaviour of the stem-packing contact. The chosen approach requires identification of the contact conditions, which is practically impossible using local measurement. Hence, the contact conditions should be reconstructed using a coupled experimental and numerical investigation. The experimental investigation is carried out on a test rig, which simulates a full-scale operated valve to reproduce the conditions of the stem-packing contact. In order to improve the understanding of the tribological behaviour, the tribological characterization is made of the stem and the flexible graphite packing after the test. Hence, they helped to define the tribological circuit of the stem-packing contact, which controls both the sealing quality around the stem and the force required to cycle the stem. Indeed, the third body flow controls the sealing quality while the third body velocity shearing mode controls the force required to cycle the stem. In order to complete the experimental analysis, numerical investigation is carried out using a finite element model. The model allows to evaluate the sealing quality of a compression packing, with the regards to the fluid pressure. In addition, the influence of friction at the stem-packing and housing-packing interfaces is highlighted through a parametric analysis. The work in this thesis helps to raise awareness about the importance of taking into account the influence of the third body in a contact. In the case of compression packing, the third body changes the contact conditions which in turn, influence the sealing quality around the stem and the force required to cycle the stem
5

Ecologie de la santé humaine : contribution à l'étude et à la surveillance des épidémies de gastro-entérite aigüe d'origine hydrique / Ecology of human health : contribution to the study and to the surveillance of waterborne disease outbreaks of gastrointestinal illness

Mouly, Damien 23 June 2016 (has links)
Les épidémies de gastro-entérite aigüe liées à l’eau du robinet demeurent un enjeu de santé publique au 21ème siècle dans les pays développés. La majorité des dispositifs de surveillance mis en place dans les pays se caractérisent par une sous-déclaration. En France, l’amélioration de la surveillance de ces évènements repose sur l’exploitation des données de l’Assurance Maladie. L’objectif de notre travail est de proposer une méthode pour améliorer la sensibilité et la spécificité de la détection des épidémies de gastro-entérite aigüe d’origine hydrique. Trois études ont été menées pour i) évaluer la capacité des données de l’Assurance Maladie à décrire des épidémies de gastro-entérite aigüe d’origine hydrique, ii) adapter une méthode de détection spatio-temporelle en intégrant l’exposition à l’eau du robinet, iii) évaluer les performances de cette méthode. Notre travail a permis de développer une méthode de détection spatio-temporelle des épidémies hydriques en tenant compte des unités géographiques de distribution d’eau avec une bonne sensibilité et une bonne valeur prédictive positive. Les performances de détection sont principalement liées à la taille de l’épidémie. La capacité des données de l’Assurance Maladie à détecter des épidémies d’origine hydrique peut être influencée par les habitudes de recours aux soins, la sensibilisation de la population au risque infectieux d’origine hydrique et le niveau d’agrégation temporel des cas de gastro-entérite aigüe. La finalité de nos travaux de recherche est l’application opérationnelle pour la détection automatisée des épidémies hydriques dans une finalité de prévention et de réduction de leur impact sanitaire. / Waterborne disease outbreaks (WBDO) of acute gastrointestinal illness remain a public health concern in the 21st century in developed countries. Almost all surveillance systems implemented in countries are characterized by underreporting. In France, the improvement of monitoring these events is based on the use of data from the French Health Insurance. The aim of our work was to propose a method to improve the sensitivity and specificity of the detection of WBDO. Three studies were conducted to i) evaluate the ability of French Health Insurance data to describe WBDO ii) apply a method of space-time detection by integrating the exposure to tap water, iii) evaluate the performance of this method. Our work allowed developing a method of space-time detection of WBDO by taking into account geographical units for drinking water networks units with a good sensitivity and positive predictive value. The performances for detection are mainly related to the size of the epidemic. The ability of the data from the French Health Insurance to detect WBDO can be influenced by the health-seeking behavior of people, awareness of the population to the risk of WBDO and the temporal aggregation level of cases of acute gastrointestinal illness. The purpose of our research is to carry out an operational design for the automated detection of WBDO in a purpose of prevention and reduction of health impact.
6

Chlorine flavor perception and neutralization in drinking water / Perception et neutralisation de la flaveur chlore dans l'eau de boisson

Puget, Sabine 07 May 2010 (has links)
Pour les distributeurs d’eau, l’utilisation de chlore permet d’assurer la qualité bactériologique de l’eau, de l’usine de traitement au robinet du consommateur. Cependant, la flaveur chlore constitue une des plaintes les plus importantes adressée à l’encontre de l’eau du robinet et constitue donc un enjeu majeur de satisfaction des consommateurs. Dans ce contexte, l’objectif des travaux engagés dans cette thèse a été de mettre en évidence des moyens potentiels de neutralisation sensorielle de la flaveur chlore dans l’eau. Néanmoins, les mécanismes impliqués dans la perception de cette flaveur étant largement méconnu, notre première étape a consisté à préciser la nature de ces mécanismes. Nos résultats ont ainsi mis en évidence que l’acide hypochloreux sous sa forme associée, qui est le stimulus supposé de la flaveur chlore dans l’eau, active le système olfactif à faibles concentrations et le système trigéminal à partir de 4 mg/L. De plus, nous avons observé que la consommation d’eau du robinet ne semble pas liée à la sensibilité au chlore mais plutôt à la représentation qu’ont les consommateurs de l’eau du robinet. Dans un deuxième temps, nous avons exploré le rôle de la matrice de l’eau dans la perception de la flaveur chlore. Nous avons d’abord montré que les variations de molarité et de composition en cations de l’eau modulent le goût de l’eau. Nous avons ensuite mis en évidence une modulation de l’intensité chlorée en fonction de la matrice minérale de l’eau. Cependant, nos données suggèrent l’existence de mécanismes multiples, physicochimiques, physiologiques en bouche et sensoriels, susceptibles de moduler la perception de la flaveur chlore. Enfin, nous avons exploré les interactions perceptives entre un arôme supposé neutralisant et ajouté à l’eau de boisson et la flaveur chlore. Nos résultats montrent que l’ajout d’un arôme à un niveau péri-liminaire augmente la perception de la flaveur chlore et diminue l’acceptabilité des consommateurs. A plus forte concentrations, certains arômes semblent capables de diminuer la perception du chlore, mais ces conditions sont incompatibles avec les contraintes liées à l’eau de distribution / For water suppliers, using chlorine is necessary to ensure water bacteriological quality from the treatment plant to the consumers’ tap. However, chlorine flavour is one of the most common reasons advocated for choosing tap water alternatives as drinking water. As a consequence, the putative link between chlorine flavour perception and tap water consumption is an issue in drinking water habits studies. Since the sensory mechanisms involved in chlorine flavour perception remained largely unknown, the main objective of this thesis work was to first highlight those mechanisms and then to identify potential lever chlorine flavour sensory neutralisation.In a first step, we demonstrated that hypochlorous acid associated, which is likelyresponsible of chlorine flavour in tap water, could activate the olfactory system at low concentrations and the trigeminal system for concentrations up to 4 mg/L Cl2. Additionally, our results suggested that tap water consumption does not seem to be related to sensitivity to chlorine flavour but rather to consumers’ tap water representation.In a second stage, we explored the impact of water mineral matrix on chlorine flavour perception. We demonstrated first that water molarity and cationic content variations modulate drinking water taste. We also evidenced that chlorine flavour intensity is modulated according to water composition. Nevertheless, our data suggest that physico-chemical, in- mouth physiological and sensory mechanisms are likely involved in such modulation.In the last part of the Thesis work, we investigate the putative influence of aroma perceptionon chlorine flavour. Our results showed that beyond chemical reactions between hypochlorous acid and odorants, aromas at peri-threshold concentration enhance chlorine flavour and decrease tap water acceptability
7

Density and proximity of unconventional oil and gas wells and concentrations of trace elements in urine, hair, nails and tap water samples from pregnant women living in Northeastern British Columbia

Gasparyan, Lilit 07 1900 (has links)
The Peace River Valley (British Columbia, Canada) is an area of intensive unconventional oil and gas (UOG) exploitation, an activity that can release contaminants with possible adverse effects on the fetus. My project aimed to estimate the importance of this exposure. For this aim, we 1) measured concentrations of 21 trace elements in tap water and biological (hair, urine, nails) samples from 85 pregnant women in this region; 2) compared them with those from the general population and health-based guidance values; 3) assessed their correlations between matrices; and 4) evaluated their associations with the density and proximity of UOG wells (i.e., wells within radii of 2.5 km, 5 km, 10 km, and with all wells in British Columbia around residences). Spearman's rank correlation and multiple linear regression analyses adjusted covariates were performed. Our results showed higher urinary and hair levels of certain trace elements compared to reference populations (e.g., Co, Ba, Sr, Mn, V, Ga). Concentrations in tap water correlated strongest with concentrations in hair, followed by nails and urine. Positive (e.g., Al, Mn, Cu, Ga, Cd, Ba, Cr, Sr, U) and negative (e.g., Fe) associations were observed between the density and proximity of UOG wells and the concentrations of certain trace elements in tap water, hair, and nails. Our results suggest that pregnant women living in an active area of UOG exploitation are likely to be more exposed to certain trace elements than the general population, but the association with density and proximity to wells remains uncertain. / La vallée de la rivière de la Paix (Colombie-Britannique, Canada) est une zone d’exploitation de pétrole et de gaz naturel par méthodes non-conventionnelles (PGNNC), une activité qui est susceptible de libérer des contaminants avec des effets nocifs possibles sur le foetus. Mon projet visait à estimer l’importance de cette exposition. À cette fin, nous avons 1) mesuré les concentrations de 21 éléments traces dans des échantillons de cheveux, d'ongles, d'urine et d'eau du robinet de 85 femmes enceintes de cette région, 2) comparé celles-ci avec celles de la population générale et des valeurs-guides, 3) évalué leur corrélation entre matrices et 4) évalué leur association avec la densité et proximité des puits (mesures pour des rayons de 2,5 km, 5 km, 10 km, et sans limite autour des résidences). Des analyses de corrélation de Spearman et de régression linéaire multiple ajustées pour certaines variables ont été effectuées. Les concentrations urinaires et capillaires étaient plus élevées pour certains éléments traces par rapport aux populations de référence (p. ex. Co, Ba, Sr, Mn, V, Ga). Les concentrations dans l'eau du robinet étaient plus fortement corrélées avec les concentrations dans les cheveux, suivis des ongles et de l'urine. Des associations positives (p. ex. Al, Mn, Cu, Ga, Cd, Ba, Cr, Sr, U) et négatives (p. ex. Fe) ont été observées entre la densité/proximité des puits de PGNNC et les concentrations de certains éléments traces dans les échantillons d'eau, de cheveux et d’ongles. Nos résultats portent à croire que les femmes enceintes vivant dans une zone active de PGNNC sont susceptibles d’être plus exposées à certains éléments traces que la population générale, mais le lien avec la densité et la proximité des puits demeure incertain.
8

Analyse d’hormones stéroïdiennes par spectrométrie de masse dans les eaux du robinet, de surface et les eaux usées

Goeury, Ken 02 1900 (has links)
Il apparaît au grand jour que de nombreuses substances telles que les perturbateurs endocriniens sont introduites quotidiennement dans l’environnement. Ces molécules organiques bien souvent d’origine anthropique peuvent être employées dans d’innombrables circonstances : pharmaceutique, médecine, agriculture, cosmétique, agroalimentaire pour citer quelques exemples. Parmi ce large panel de composés, se trouvent les hormones stéroïdiennes. Un certain nombre de maladies et de modifications aussi bien comportementales que physiologiques tant chez l’humain que sur la faune aquatique sont attribuées à l’usage et aux rejets chroniques de ces perturbateurs endocriniens. Il est donc indispensable de développer une approche portée sur la prévention et l’étude des niveaux de contamination selon un seul maître-mot : précaution. Dans ce contexte, ce projet de doctorat visait à développer de nouvelles méthodes de détection des hormones stéroïdiennes à niveau ultra-trace dans diverses matrices environnementales. La sélection des composés ciblés dans ce projet s’est basée sur la nouvelle liste de perturbateurs endocriniens prioritaires de l’agence de protection de l’environnement des États-Unis (US EPA), récemment élargie à d’autres classes de substances dont le bisphénol A. Les méthodes analytiques ont été développées non seulement dans l’eau du robinet (EPA 539), mais également dans d’autres matrices plus complexes (eaux de surface, eaux usées). Commune à l’ensemble des procédures testées, la phase de validation analytique a permis de vérifier la conformité avec les exigences de performance de l’EPA. La première méthode mise au point repose sur une pré-concentration rapide de l’échantillon par extraction sur phase solide en ligne (on-line SPE) couplée à la chromatographie liquide à ultra-haute performance (UHPLC) et à la spectrométrie de masse en tandem (MS/MS). La méthode validée présente de nombreux avantages—reproductibilité, automatisation, temps d’analyse minimal, logistique réduite et surtout des limites de détection de 0,10 ng·L-1 à 7,5 ng·L-1 selon les différentes matrices étudiées. Cette méthode apparaît particulièrement adaptée pour la détection des hormones dans les eaux usées, en lien avec les plus fortes concentrations attendues. Cependant, il est apparu pertinent d’améliorer encore la sensibilité des méthodes dans certains contextes, notamment dans le cadre des iv analyses d’eau de surface, compte tenu des critères de qualité applicables. La principale modification fut apportée au niveau de l’extraction et de la purification des échantillons. Amendée à la faveur des différentes matrices, l’étape d’extraction par SPE hors-ligne automatisée (off-line SPE) a permis d’atteindre des limites de détection adéquates variant de 0,010 ng·L-1 à 6,0 ng·L-1 dépendamment de la matrice et du composé. Un aspect original de cette étude a consisté à étudier de façon plus systématique les facteurs de robustesse de la méthode lorsque soumise à certaines variations, tant au niveau de l’analyse instrumentale (phases mobiles, volume d’injection) que des protocoles (emploi de différents agents de conservation, par exemple). L’analyse de la phase dissoute ne saurait être suffisante pour comprendre le devenir environnemental des perturbateurs endocriniens dans les milieux aquatiques, notamment leur distribution. Dans cette optique, la phase particulaire en suspension dans la colonne d’eau (SPM) fut également étudiée après optimisation et validation de la méthode d’extraction. Les limites de détection obtenues étaient comprises entre 0,10 ng/g et 3,0 ng/g, un degré de performance adéquat au regard des teneurs attendues dans l’environnement. De telles méthodes ne trouveraient pas de fondement si elles n’étaient pas employées à l’analyse d’échantillons réels. C’est pourquoi, pour chaque méthode développée, une série d’échantillons d’eau a été analysée pour toutes les matrices étudiées. La quantification des hormones stéroïdiennes a permis de rendre compte des niveaux de concentrations retrouvés dans l’environnement. Une étude saisonnière d’un cours d’eau a également été réalisée durant quatre saisons (hiver, printemps, été et automne) afin d’évaluer les éventuelles variations saisonnières en termes d’occurrence et de concentration. / It is now admitted that many substances such as endocrine disruptors are released daily into the environment. This process can be of natural origin but is predominantly linked to human activity. Endocrine disruptors originate from numerous fields: medicine, agriculture, cosmetics, and the food industry, to name a few. Steroid hormones belong to this wide array of compounds. A significant number of human diseases and behavioral and physiological changes in both humans and aquatic life have been attributed to the use and chronic release of these endocrine disruptors. The effects of such a cocktail of substances are difficult to understand and evaluate. To date, the synergistic mechanisms or the potential cumulative effects are not well known. It remains essential to develop an approach focused on the prevention and the study of contamination levels with one key word in mind: precaution. In this context and aiming to detect steroid hormones in tap water, surface water and wastewater at trace levels, new analytical methods have been developed within the framework of this project. The first method developed is based on high performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS / MS). LC-MS/MS hyphenation involved using an electrospray ionization source at atmospheric pressure with heating element (H-ESI). Pre-concentration and purification of the samples were executed by on-line solid phase extraction (on-line SPE). The validated method presents several advantages: reproducibility, automation, minimum analysis time, reduced logistics and above all, detection limits ranging from 0.10 ng·L-1 to 7.5 ng·L-1 considering the different matrices studied. The second approach proposed herein is based on the development of an analysis method allowing lower detection limits compared to the previous workflow. The same detection method was used, but a modification was made to the sample extraction and purification. Allowing for greater pre-concentration than online SPE, manual SPE (off-line SPE) was used in this method. Depending on the particular matrix, the extraction step allowed to reach adequate detection limits for the analysis of environmental aqueous samples: 0.010 ng·L-1 up vi to 6.0 ng·L-1 from the matrix-free sample to the most complex matrices. The use of an automated system also made it possible to make the extraction step robust and reproducible. The analysis of the dissolved phase of water samples cannot be sufficient to understand and comprehensively assess the contamination of aquatic environments. The particulate phase in suspension in the water column (SPM) was also studied. The extraction method was optimized and validated. Coupled with the previous method of analysis, it was possible to quantify the steroid hormones attached to suspended materials. The obtained detection limits ranged from 0.10 ng/g to 3.0 ng/g dry weight. For each developed method, dissolved phase samples were analyzed for all the studied matrices (tap water, surface water and wastewater). Quantification of steroid hormones allowed the comprehension of concentration levels found in the environment under usual discharge conditions in multiples matrices. A seasonal study of a watercourse was also carried out during the winter, spring, summer and fall seasons to observe possible seasonal variations in terms of occurrence and concentration.

Page generated in 0.049 seconds