31 |
"Influência do grau de proficiência técnica dos operadores no preparo de canais curvos, quando do emprego de instrumentos rotatórios de níquel-titânio" / Influence of the operators proficiency in the preparation of curved canals, using of rotary nickel-titanium instrumentsJosé Lauriére Horta Guimarães 26 April 2006 (has links)
O presente estudo avaliou a interferência de operadores com diferentes proficiências no preparo de canais radiculares curvos, simulados em blocos de resina transparente. Os grupos, com 10 indivíduos cada um, foram: Grupo 1 professores de Endodontia; Grupo 2 - alunos de especialização; Grupo 3 alunos de odontologia Monitores de Endodontia e o Grupo 4 alunos de graduação no início do curso de Endodontia. Cada operador instrumentou dois canais com 20 graus de curvatura, o primeiro canal era visualizado para treinamento e o segundo não. O sistema mecanizado com instrumentos rotatórios de níquel-titânio empregado foi o RaCe®. Os parâmetros de avaliação foram: tempo de instrumentação, quantidade de material removido, desvio apical e deformação dos instrumentos. Os resultados encontrados (ANOVA e Teste de Tuckey a= 0,05%), foram: Para o tempo de instrumentação, no primeiro canal, houve diferença estatística entre o grupo 1 e os grupos 3 e 4, o grupo 2 diferiu somente do grupo 4. Já, no segundo canal, não houve diferença estatística entre os grupos. Para a quantidade de material removido do primeiro canal houve diferença estatística entre os graduados (grupos 1 e 2) em relação aos graduandos (grupos 3 e 4), porém, no segundo canal, houve diferença somente entre os grupos 1 e 2. O desvio apical não apresentou diferença estatística entre os grupos em nenhuma das condições experimentais. Após a aplicação do teste do Qui-quadrado (a=0,01%), observou-se que o grupo 1 foi o que produziu as menores deformações nos instrumentos. Conclui-se que: Os desvios apicais promovidos foram semelhantes entre os grupos experimentais. Houve diminuição no tempo de instrumentação do segundo canal em relação ao primeiro, com diferença estatística nos grupos dos monitores e acadêmicos e que não houve diferença estatística entre os grupos, em relação ao tempo de instrumentação do segundo canal. Os grupos dos graduados (professores e alunos de especialização) excisaram maior quantidade de material do primeiro canal, quando comparados aos dos graduandos (monitores e acadêmicos), não havendo diferença estatística entre os grupos em relação à quantidade de material removido do segundo canal, excetuando a comparação entre os professores e os alunos de especialização, onde os primeiros desgastaram significativamente mais que os últimos. Comparados aos demais grupos, os professores produziram menores deformações aos instrumentos. / This study evaluated the interference of operators with different proficiencies in the preparation of curved canals , simulated transparent resin blocks. The groups, with 10 individuals each, were: Group 1 - professors of Endodontics; Group 2 students of specialization; Group 3 undergraduate dental students who had concluded the Endodontics course and Group 4 - undergraduate dental students in the beginning of the Endodontics course. Each operator prepared two canals with 20 degrees of bending, the first canal was visualized for training and second no. The rotary instrumentation used was the RaCe®. The parameters of evaluation were: time of instrumentation, amount of removed material, apical transportation and deformation of the instruments. The results (ANOVA and Test of Tuckey = 0.05%): In relation to the instrumentation time, when of the execution of the first canal, it had statistics difference between group 1 and groups 3 and 4, group 2 only differed from group 4. When of the execution of the second canal it did not have difference statistics between the groups. For the amount of material removed of the first canal it had difference statistics between the graduated (groups 1 and 2) relation to the undegraduated (groups 3 and 4). After the second canal instrumentation, only had difference between groups 1 and 2. The apical transportation did not present statistics difference enters the groups in no ne of the experimental conditions. After the application ?2 test (a=0,01%), was observed that group 1 produced lesser deformations in the instruments. Conclusions: The apical transportation was similar between the different groups. It had reduction in the time of instrumentation of the second canal in relation to the first one, with statistics difference in the groups of the monitors and academics. It did not have difference statistics between the groups, in relation to the time of instrumentation of the second canal. The groups of the graduated ones (professors and students of specialization) removed bigger amount of material of the first canal, when compared with the ones of the undergraduate (monitorial and academic). It did not have statistics difference enters the groups in relation to the amount of material removed of the second canal, excepting the comparison between the professors and the students of specialization, where the first ones had consumed significantly more than the last ones. Compared with all groups, the professors had produced minors deformations to the instruments.
|
32 |
Avaliação do selamento e transporte apical em dentes humanos com canais preparados com o sistema rotatório MTWO® com e sem ampliação foraminal = estudo in-vitro / Evaluation of apical sealing and transportation in human teeth prepared by MTWO® rotatory system with and without foraminal enlargement : in vitro studyWinocur, Estela Marta Doffo de, 1964- 02 July 2012 (has links)
Orientador: Adriana de Jesus Soares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T22:30:40Z (GMT). No. of bitstreams: 1
Winocur_EstelaMartaDoffode_D.pdf: 39787975 bytes, checksum: dfb0acb3bf358d565765b0c840c32986 (MD5)
Previous issue date: 2012 / Resumo: O objetivo deste estudo in vitro foi avaliar o selamento apical após obturação endodôntica, em dentes humanos preparados com e sem ampliação do forame apical, com o Sistema Rotatório Mtwo® (VDW, Munique, Alemanha). Vinte prémolares inferiores foram divididos em dois grupos. No Grupo I, os canais radiculares foram preparados 1mm além do forame apical e, no Grupo II, 1 mm aquém do CRC. Os dentes foram preparados para avaliação no MEV (JEOL, Modelo JSM 5600LV, Tókio, Japão) e as imagens do forame apical obtidas em aumento de 75x, em posições padronizadas, permitindo a mensuração da área foraminal antes, após o preparo e após a obturação. Por meio do processo do Sistema de Subtração de Imagens (Emago® Sistema de Diagnóstico Oral, Louwesweg, Amsterdam, Holanda), foi possível identificar as variações de forma e transporte do forame apical assim como o nível de preenchimento de sua circunferência pelo cimento obturador Pulp Canal Sealer (Sybron Endo, USA) após o preparo. Os resultados encontrados, submetidos à análise estatística, permitiram concluir que os dentes do Grupo I apresentaram maior diâmetro foraminal que os do Grupo II (Teste Anova, p<0,05) e que houve diferença estatisticamente significante quanto ao transporte do forame (Teste Exato de Fisher, p=0,0108); quanto ao selamento apical houve diferença estatisticamente significante entre os grupos I e II (Testes t de Student e Exato de Fisher, p=0,0007) sendo que, no Grupo I, ocorreram selamento em 100% dos espécimes analisados / Abstract: The aim of this in vitro study was to evaluate the apical root sealing after endodontic filling, in human teeth that were prepared with and without apical foramen enlargement by Mtwo® Rotary System (VDW, Munich, Germany). Twenty mandibular premolars were divided in two groups. Group I had root canals prepared 1mm beyond apical foramen, and in Group II, 1mm below RCL. Teeth were prepared for an electronic microscopy analysis (JEOL, Model JSM 5600LV, Tokyo, Japan). Apical foramen images were 75 times magnified, at standardized positions, allowing measurements from apical foramen area before and after root canal preparation, and after root filling. By using the Image Subtraction System (Emago®, Oral Diagnostic System, Louwesweg, Amsterdam, Netherlands) apical foramen shape modifications and transportation as well as the level of its circumferential filling by Pulp Canal Sealer cement (Sybron Endo, USA) after root canal preparation were accessed. After statistical analysis, results allowed to conclude that Group I teeth showed larger foraminal diameter than Group II (Anova Test, p<0,05) and that foramen transportation difference was statistically significant (Fisher Exact Test, p=0,0108); apical foramen sealing also differed statistically between groups I and II (Student t Test and Fisher Exact Test, p=0,0007) and that 100% of Group I specimens showed apical root sealing / Doutorado / Endodontia / Doutor em Clínica Odontológica
|
33 |
EFEITO DA INSTRUMENTAÇÃO ENDODÔNTICA, DO TIPO DE RETENTOR INTRARRADICULAR E DA CICLAGEM MECÂNICA NA RESISTÊNCIA À FRATURA DE RAÍZES / EFFECTS OF ROOT CANAL INSTRUMENTATION, TYPE OF ROOT POST AND MECHANICAL CYCLING ON THE FRACTURE STRENGTH OF ROOTSRippe, Marilia Pivetta 16 March 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the effect of root preparation strategy, the type of post and mechanical cycling on root fracture resistance. Eighty single-rooted human teeth were divided into 8 groups (n=10): G1 and G2 - hand file, glass fiber post, without and with mechanical cycling (MC) respectively; G3 and G4 - hand file, cast post and core, without and with MC respectively; G5 and G6 rotary file, glass fiber post, without and with MC respectively; G7 and G8 rotary file, cast post and core, without and with MC respectively. Obturation was performed by the lateral condensation technique. Root canals were prepared to a length of 10mm, using a #2 preparation bur of a tapered fiber glass post system. The following protocol was used for the cycling: 45o angle, 37°C, 88N, 4Hz, 2 million cycles. All groups were submitted to fracture resistance test in a device in 45°, at 0.05cm/min. The 3-way ANOVA showed the instrumentation strategy (p<0.03) and the post type (p<0.0001) had significant effects, however, mechanical cycling had not (p<0.29). The type of instrumentation caused effect on the fracture strength, only when the roots were restored with fiber glass post and cycled, with disadvantage for hand instrumentation. The cast post and core promoted higher fracture resistance, although showed more irreparable failures than roots restored with glass fiber post. / O objetivo deste estudo foi avaliar o efeito da estratégia de preparo radicular, do tipo de pino e da ciclagem mecânica na resistência à fratura de raízes. Métodos: 80 raízes unirradiculares humanas foram divididas em 8 grupos (n=10): G1 e G2- lima manual, retentor de fibra de vidro (RFV), sem e com ciclagem mecânica (CM) respectivamente; G3 e G4- lima manual, retentor metálico fundido (RMF), sem e com CM respectivamente; G5 e G6- instrumento rotatório, RFV, sem e com CM respectivamente; G7 e G8- instrumento rotatório, RMF, sem e com CM respectivamente. A obturação foi realizada pela técnica da condensação lateral. Todos canais radiculares foram preparados para pino em 10 mm com a broca de preparo do sistema de pinos de fibra de vidro #2. Para a ciclagem, seguiu-se o protocolo: angulação 45°, 37 °C, 88 N, 4 Hz, 2 milhões de pulsos. Todos os grupos foram submetidos ao teste de resistência à fratura, em um dispositivo a 45º a uma velocidade de 0.05 cm/min até a falha ocorrer. A análise de variância 3 fatores mostrou que a estratégia de instrumentação (p<0,03) e o tipo de pino (p<0,0001) tiveram efeitos significativos, mas a ciclagem mecânica não (p<0,29). O tipo de instrumentação causou efeito na resistência à fratura, somente quando as raízes foram restauradas com pinos de fibra de vidro e cicladas, com prejuízo para a instrumentação manual. Os retentores metálicos fundidos proporcionaram maior resistência à fratura, contudo apresentaram mais falhas irreparáveis do que raízes restauradas com pino de fibra.
|
34 |
Avaliação da capacidade de corte e resistência à fadiga cíclica dos instrumentos Profile Vortex e ProTaper / Evaluation of cutting ability and cyclic fatigue resistance of instruments Profile Vortex and ProTaperGraziela Salum 03 August 2012 (has links)
Objetivo: Analisar in vitro a capacidade de corte e a resistência à fadiga cíclica dos sistemas rotatórios ProFile Vortex (Dentsply Tulsa Dental, USA) e ProTaper (Dentsply Maillefer, Suíça). Metodologia: Para a análise da capacidade de corte, pesou-se em balança analítica digital cem blocos de resina fenólica que continham canais simulados com 75 de curvatura, obtendo-se os pesos iniciais (P0) e após a instrumentação dos canais, estes blocos foram novamente pesados obtendo-se os pesos finais (P1). Dividiram-se quarenta instrumentos em dois grupos. Grupo A: vinte instrumentos ProFile Vortex n25; 25mm; taper.06 e Grupo B: vinte instrumentos ProTaper F1; 25mm. Subdividiu-se em dois subgrupos com dez amostras cada, de acordo com o número de usos, sendo estabelecidos da seguinte maneira: grupos A0 e B0, instrumentos sem nenhum uso e grupos A5 e B5, instrumentos de cinco usos. Avaliou-se a resistência à fadiga cíclica submetendo-se todos os instrumentos a ensaio dinâmico, utilizando-se dispositivo desenvolvido para tal, até a ocorrência da fratura que foi constatada visualmente. O número de ciclos até a fratura assim como o tempo expresso em segundos foram registrados e realizou-se estatística descritiva, o teste `t de Student e o teste de Mann-Whitney. Resultados: Em todos os blocos houve perda de peso, porém sem significado estatístico (Pvalor>0,05). Os instrumentos Profile Vortex removeram mais material e completaram maior número de ciclos até a fratura, com significância estatística (Pvalor>0,05) quando comparados com os instrumentos Protaper. Conclusão: A capacidade de corte em função do número de uso e a resistência à fadiga cíclica, nos parâmetros utilizados neste estudo, foram maiores para os instrumentos Profile Vortex quando comparados com os instrumentos Protaper. / Aim: The aim of this study was to evaluate in vitro the ability to cut and cyclic fatigue resistance of rotary systems ProFile Vortex (Dentsply Tulsa Dental, USA) and ProTaper (Dentsply Maillefer, Switzerland). Methods: To analyze the ability to cut weight in analytical scale digital block one hundred made of phenolic resin containing simulated channels 75 curvature obtaining to the initial weights (P0) and following the instrumentation of canals, these blocks were weighed again obtaining is the end weight (P1). Instruments forty were divided into two groups. Group A: twenty ProFile Vortex instruments n25, 25mm; taper.06 and Group B: twenty ProTaper instruments F1, 25mm. Subdivided into two subgroups with ten samples each, according to the number of uses, is established as follows: A0, B0 groups, without using tools and groups A5 and B5, five uses instruments. To evaluate the fatigue resistance cyclic submitting all the dynamic test instruments using device developed for this purpose, until the occurrence of fracture was observed visually. O number of cycles fracture to and the time in seconds were recorded and analysis descriptive, the `t Student test and Mann-Whitney. Results: In every block there was weight loss, however no statistical significance (Pvalor> 0.05). The Vortex Profile instruments removed more material and completed a greater number of cycles to fracture, with statistical significance when compared with the instruments Protaper (Pvalor> 0.05). Conclusions: The cutting ability the number of use and cyclic fatigue resistance, the parameters used in this study were higher for the Vortex Profile instruments when compared with Protaper instruments.
|
35 |
Desvio, capacidade de centralização e fadiga cíclica promovidos por instrumentos TF Adaptive e Navigator EVO, em diferentes cinemáticasDuarte, Pedro Henrique Marks January 2017 (has links)
Introdução: A evolução dos instrumentos de NiTi pode ser dividida em gerações de acordo com algumas modificações tais como: tratamento térmico da liga, secção transversal e movimento utilizado para o preparo do canal, que pode ser movimento rotatório contínuo ou movimento oscilatório assimétrico. Essas mudanças tem como objetivo prover maior flexibilidade aos instrumentos, permitindo uma melhor modelagem do canal, com menor desvio e menor risco de perfurações. Outro aspecto relevante é a maior resistência à fadiga cíclica, das ligas com tratamento térmico, colaborando para uma maior resistência à fratura do instrumento. Objetivos: Este estudo comparou a fadiga cíclica, o transporte do canal , a capacidade de centralização e o volume do canal pós preparo, produzidos pelos sistemas TF Adaptive e Navigator EVO, quando utilizados em rotação contínua ou no movimento Adaptive. Métodos: Quarenta raízes mésio-vestibulares de molares superiores foram analisadas através de micro-CT antes e depois do preparo do canal radicular com os dois sistemas e dois movimentos (Adaptive e Rotação Contínua). As amostras foram divididas em quatro grupos: TFA – instrumentos TF Adaptive utilizados no movimento Adaptive; TFC –instrumentos TF Adaptive utilizados em rotação contínua; NA – instrumentos Navigator EVO utilizados no movimento Adaptive; e NC – instrumentos Navigator EVO utilizados em rotação contínua. Adaptive; e NC – instrumentos Navigator EVO utilizados em rotação contínua. Os canais radiculares foram preparados até instrumentos 35.04. O transporte apical, a capacidade de centralização e o volume de preparo foram analisados utilizando-se micro-CT em três níveis: 3, 6 e 9mm do ápice.O teste de fadiga cíclica foi realizado utilizando um equipamento apropriado, onde, dez instrumentos de cada marca foram utilizados em um contraângulo redutor 6:1 e um motor elétrico com controle de torque, com programas prédefinidos ‘‘custom mode'' e ‘‘TF Adaptive'' para ativar os instrumentos 25.06 e 35.04.Os resultados foram analisados com os testes Kruskal-Wallis eDunn para se verificar o transporte do canal, a capacidade de centralização e o volume do canal. O teste Student-T foi usado para avaliar a fadiga cíclica (P = 0,05). Conclusões: Ambos sistemas podem ser usados no movimento Adaptive ou em rotação contínua. Porém, a resistência à fratura dos instrumentos foi maior quando utilizados em rotação contínua. Pouco transporte de canal ocorreu, quando os canais mésio-vestibulares de molares superiores foram preparados até instrumentos 35.04. / Introduction: The evolution of NiTi instruments can be divided in generations, according to changes like in the NiTi alloy, heat treatment, cross-section format, and in the movement used for root preparation that goes form continuous rotation to asymmetric oscillation. These changes aim to provide greater flexibility to the instruments, allowing a better shaping, with less transportation and risk of perforation. Other aspect is the increased fracture resistance of the alloys with heat treatment, which is a big concern about NiTi instruments. Aim: This study compared the cyclic fatigue and the canal transportation promotedby TF Adaptive and Navigator EVO systems when used with two different motions. Methods: Forty mesiobuccal roots of maxillary molars were scanned using micro-CT imaging before and after root canal preparation with the two instrument systems two motions (adaptive and continuous rotation). Samples were divided into four groups: TFA – TF Adaptive instruments under adaptive motion; TFC - TF Adaptive instruments under continuous motion; NA - Navigator instruments under adaptive motion; and NC – Navigator instruments under continuous motion. Root canals were prepared until 35.04 instruments. Apical transportation, centering ability and volume were analyzed using micro- CT at three levels: 3, 6 and 9 mm from the apex. The cyclic fatigue tests were performed using a custom-made device. Ten instruments of each brand were activated by using a 6:1 reduction handpiece powered by a torque-controlled motor using the preset programs ‘‘custom mode'' and ‘‘TF Adaptive'' to activate25.06 and 35.04 instruments. Data were analyzed with Kruskal-Wallis and Dunn tests were used to assess canal transportation, centering ability and canal volume. Student-T test was used to evaluate cyclic fatigue (P = .05). Conclusions: Both systems can be used under adaptive or continuous rotation. However; the lifespan of the instruments was higher when used under continuous rotation. Little canal transportation occurred when mesiobuccal root canals from maxillary molars were prepared until 35.04instruments.
|
36 |
An in-vitro SEM study comparing the debridement efficacy of the EndoVac® system versus the Canal CleanMax® following hand-rotary istrumentationRicketts, Benjamin P. (Benjamin Paul), 1980- January 2010 (has links)
Indiana University School of Dentistry located on the campus of Indiana University-Purdue University Indianapolis (IUPUI) / This in-vitro, prospective, randomized study microscopically compared the debridement efficacy of negative pressure irrigation with the EndoVac (Discus Dental, Culver City, CA) versus the Canal CleanMax (Maximum Dental, Inc., Secaucus, NJ). Sixty extracted human canines were instrumented using a combination of hand-instrumentation with Lexicon K-type files and rotary instrumentation with ProTaper files. All canals were irrigated with 6.0-percent sodium hypochlorite and 17- percent ethylenediaminetetraacetic acid (EDTA). However, the irrigation/aspiration techniques differed among three groups of 20 randomly selected teeth. Group one (control) was irrigated with only a 12-ml Monoject syringe via 30-gauge side-vented, closed-end needle. Group two was irrigated with the EndoVac system. Group three was irrigated similar to group one, but with the adjunct of the Canal CleanMax system. All teeth were sectioned longitudinally, and the more intact sections were divided into coronal, middle, and apical thirds. Each portion of the canal was photographed with a scanning electron microscope (SEM). The photographs were scored by two independent examiners according to relative amount of debris and/or smear layer present, as well as relative number of patent dentinal tubules. These scores were statistically analyzed using a Krustal-Wallis test and Wilcoxon Rank Sum tests to determine differences between groups. The coronal aspect of root canal walls irrigated with the EndoVac system exhibited significantly less debris and/or smear layer present when compared to the coronal aspect of root canals irrigated with only a standard 12-ml Monoject syringe equipped with 30-gauge ProRinse side-vented, closed-end needle (control). There were no other significant differences in scores between any groups at any location. For all locations combined, the EndoVac system produced significantly cleaner root canal walls as compared to the control. No significant differences were seen between the Canal CleanMax and Control or Canal CleanMax and EndoVac. This study suggested negative pressure irrigation delivery with the EndoVac system during and after hand-rotary instrumentation is more effective in removal of debris and smear layer from the coronal third and combined thirds of root canal walls compared to irrigation with a standard 12-ml Monoject syringe equipped with 30-gauge ProRinse side-vented, closed-end needle.
|
37 |
Avaliação do preparo de canais radiculares com secção transversal oval longa realizado pelos sistemas Reciproc e Biorace utilizando a microtomografia computadorizada / Evaluation of the preparation of long oval root canals with Reciproc and Biorace systems using micro-computed tomographyBusquim, Sandra Soares Kühne 24 September 2013 (has links)
Os instrumentos endodônticos de níquel-titânio (NiTi) influenciaram positivamente o preparo dos canais radiculares. Entretanto, algumas dificuldades inerentes à própria anatomia do sistema endodôntico, permanecem. Canais radiculares com secção transversal oval longa dificultam a ação dos instrumentos rotatórios, os quais não conseguem se adaptar às suas paredes em toda extensão. O sistema Reciproc de lima única (VDW, Munique, Alemanha), recentemente lançado, foi desenvolvido para o preparo do canal radicular pela técnica de movimento de trabalho recíproco. Este movimento alivia o estresse do instrumento, reduzindo o risco de fatiga cíclica causada pela tensão e compressão. Com a finalidade de comparar o efeito deste movimento no preparo do canal, foi utilizado o sistema Biorace (FKG Dentaire, LA Chaux-de Fonds, Suíça) por ser um sistema de instrumentação rotatória completa, onde o instrumento final tem diâmetro compatível com o instrumento Reciproc R40 utilizado. O objetivo deste estudo foi avaliar, ex vivo, o preparo de canais ovais longos de molares inferiores com o sistema Reciproc comparando-o ao preparo com instrumentos do sistema Biorace, por meio da microtomografia computadorizada (CT). Raízes distais de trinta molares inferiores foram utilizadas e divididas aleatoriamente em dois grupos: G1 Reciproc R40 e G2 Biorace. Os dentes foram escaneados por um microtomógrafo de raios-X SkyScan 1172 antes e após o preparo dos canais radiculares. As imagens obtidas foram importadas e reconstruídas, fornecendo secções transversais da estrutura interna das amostras. Em seguida, com o auxílio dos softwares CTan, CTVol, MeshLab e MatLab foram possíveis a análise tridimensional e a visualização do canal radicular antes e após o procedimento do preparo químico-cirúrgico, para comparação das mudanças no volume e superfícies não preparadas da parede do canal. Os resultados foram submetidos ao teste estatístico não paramétrico de Mann-Whitney para análise do aumento do volume e das superfícies não preparadas. O teste não paramétrico de Kruskal-Wallis foi o de escolha para análise intra-grupo, ou seja, do mesmo sistema nos diferentes terços do canal. O preparo do canal radicular com o sistema Reciproc resultou em maior aumento do volume no canal como um todo e no seu terço apical (p < 0,5). Quanto à comparação das superfícies não preparadas da parede do canal, o sistema Reciproc mostrou-se superior ao sistema Biorace no terço apical (p < 0,0001). O sistema Biorace apresentou os melhores resultados, estatisticamente significantes, nos terços cervical e médio (p < 0,0001). Na avaliação das superfícies não preparadas no mesmo sistema, o sistema Reciproc mostrou melhores resultados no terço apical, em relação aos terços cervical e médio (p < 0,05), assim como o sistema Biorace. Concluiu-se que nenhum sistema conseguiu preparar completamente o canal oval longo. O sistema Reciproc determinou maior desgaste de dentina no canal como um todo e no terço apical. Em relação às superfícies não preparadas do canal, o sistema Reciproc melhor preparou o terço apical, enquanto que o sistema Biorace melhor preparou os terços cervical e médio (áreas mais ovaladas). Na comparação no mesmo sistema, Reciproc e Biorace mostraram melhores resultados, deixando menos superfícies não preparadas, no terço apical do canal. / The endodontic instruments of nickel-titanium (NiTi) positively influenced the preparation of root canals. However, some difficulties inherent to the anatomy of the endodontic system, remain. Root canals with long oval cross-section hinder the action of rotating instruments, which cant adapt to the root canal walls in all its extension. The single-file Reciproc system (VDW, Munich, Germany), recently launched, was developed to prepare the root canal in reciprocating movement. This movement relieves the stress of the instrument, thus reducing the risk of cyclic fatigue caused by tension and compression. With the purpose of comparing the effect of this movement on root canal preparation, the Biorace system (FKG Dentaire, La Chaux-de-Fonds, Switzerland) was used. This full rotary sequence system has a final instrument diameter compatible with the instrument Reciproc R40 used. The aim of this study was to evaluate, ex vivo, the preparation of long oval canals of mandibular molars with the Reciproc system comparing it to the Biorace system using micro-computed tomography (CT). Distal canals of thirty mandibular molars were used and randomly divided into two groups: G1 - Reciproc R40 and G2 - Biorace. Teeth were scanned by a micro-computed tomography SkyScan 1172 before and after the preparation of the root canals. The images obtained were imported and rebuilt, providing cross-sections of the internal structure of the samples. Then, with the aid of softwares CTan, CTVol, MeshLab and MatLab, threedimensional analysis and visualization of root canal before and after the biomechanical preparation were performed. Morphometric variations were measured by volume increases and remaining untreated canal surface area. The results were subjected to a non-parametric Mann-Whitney test for volume and untreated surface analysis and to a Kruskal-Wallis test for intra-group analysis, i.e., the same system in all different thirds of the canal. The root canal preparation with the Reciproc system resulted in greater volume increase of the whole root canal and its apical third (p < 0,5). Regarding untreated canal surface area, the Reciproc system was superior to the Biorace system in the apical third (p < 0,0001). The Biorace system presented the best results, statistically significant, in the cervical and middle thirds of the root canal (p < 0,0001). In the evaluation of untreated canal surface area in the same system, the Reciproc system showed better results in the apical third, in relation to the cervical and middle thirds (p < 0,05), as well as the Biorace system. In conclusion, regardless of the instrumentation technique used, the long oval canal couldnt be completely prepared. The Reciproc system not only removed more dentin layer in the whole canal and its apical third, but also left less untreated canal surface area in the apical third (oval shaped section). The Biorace system left less untreated canal surface area in the cervical and middle thirds. In comparison on the same system, Reciproc and Biorace showed better results, leaving less untreated surface in the apical third of the root canal.
|
38 |
Análise comparativa em microtomografia do preparo dos canais mesiais de molares inferiores por quatro sistemas rotatórios de níquel-titânio / A comparison of four nickel-titanium Rotary system to prepare mesial root canals of mandibular molars. A microcomputed tomography studyVillas Bôas, Marcelo Haas 27 May 2011 (has links)
O objetivo deste estudo foi avaliar por meio da microtomografia computadorizada (micro-CT), a qualidade do preparo dos canais mesiais de molares inferiores, realizado pelos sistemas rotatórios de níquel-titânio (NiTi), ProTaper, Mtwo, BioRaCe e Twisted File. As variáveis testadas foram: habilidade em manter o canal centralizado, extensão e direção dos eventuais transportes, quantidade de dentina removida, espessura mínima de dentina remanescente e variações quanto aos volumes apical e total, antes e após a instrumentação. Sessenta e seis molares inferiores foram escaneados no microtomógrafo (Skyscan 1076) utilizando uma resolução de 18 µm. Após a reconstrução das imagens, quarenta dentes foram selecionados e divididos em quatro grupos de acordo com a similaridade da anatomia interna dos canais radiculares (N=10). Os dentes foram instrumentados com os sistemas rotatórios de NiTi até os instrumentos 25/.06 Mtwo e BioRaCe, 25/.08 Twisted File e F2 ProTaper. Após a instrumentação os dentes foram novamente escaneados e os parâmetros testados foram analisados, comparando os valores obtidos antes e após a instrumentação. Os resultados foram submetidos ao teste estatístico não-paramétrico de Mann Whitney e de Kruskal-Wallis e Dunn. Nos quatro grupos, não houve diferença entre os sistemas rotatórios relativos ao transporte do canal em todos os níveis radiculares. Adicionalmente, o terço cervical apresentou a maior quantidade de transporte quando comparado aos níveis apicais e a menor quantidade de dentina remanescente, especialmente para a zona de perigo em comparação com os demais níveis. A avaliação da variável dentina remanescente demostrou que não houve diminuição da quantidade de dentina em nenhuma das direções avaliadas nos níveis apicais em nenhum dos sistemas rotatórios. Similarmente não houve aumento significativo do volume apical e total em comparação ao volume pré-operatório. Não foram encontradas perfurações ou rasgos, o que indica que todos os sistemas avaliados foram seguros nesse item. Conclui-se que os sistemas rotatórios de NiTi avaliados não aumentaram significativamente os volumes apical e total dos canais radiculares, o maior índice de transporte foi no terço cervical e médio para todos os sistemas avaliados. A quantidade de dentina remanescente diminuiu significativamente nos terços cervical e médio na direção voltada para a furca, em todos os sistemas utilizados. / The aim of this study was to evaluate by microcomputed tomography (micro-CT), the quality of mesial canal preparation achieved by 4 nickel-titanium rotary systems (NiTi), ProTaper Mtwo, BioRaCe and Twisted File. The variables tested were: ability to maintain the center of the canal, the extent and direction of any transport, the amount of dentine removed, the remaining dentin thickness and variations in the apical and total volumes, before and after instrumentation. Sixty-six molars were scanned using a X-ray micro-CT scanner (SkyScan 1076) with a resolution of 18 micrometers, after image reconstruction forty teeth were selected and divided into four groups according to the similarity of the internal anatomy of root canals (N = 10). The root canals were instrumented with NiTi rotary systems Mtwo BioRaCe until the 25/.06 instrument, and to the 25.08 Twisted File and F2 ProTaper instruments. After instrumentation the teeth were again scanned and the tested parameters were analyzed by comparing the values obtained before and after instrumentation. The results were tested using statistical non-parametric Mann Whitney and Kruskal-Wallis and Dunn. The transportation of the root canal was similar using the evaluated Rotary systems at all levels. Additionally, the cervical showed the greatest amount of transport when compared to apical levels and the lowest amount of remaining dentin especially for the danger zone in comparison with other levels. The evaluation of the variable remaining dentin showed that there was no decrease in the amount of dentin in either direction evaluated at the apical levels in any of rotary systems. In addition, there was no significant increase in apical or total volume as compared to preoperative values. There were no perforations found indicating that all systems evaluated were safe in this item. It can be concluded that NiTi rotary systems evaluated did not significantly increase the volumes of the root canal system, the transport was higher in the cervical and middle third for all systems evaluated. The amount of remaining dentin decreased significantly in the cervical and middle thirds in the direction toward the furcation in all the systems used.
|
39 |
Análise da capacidade de limpeza promovida por dois sistemas de lima única em movimento reciprocanteCarvalho, Maira de Souza 21 February 2014 (has links)
Submitted by Geyciane Santos (geyciane_thamires@hotmail.com) on 2015-06-11T13:40:10Z
No. of bitstreams: 1
Dissertação - Maira de Souza Carvalho.pdf: 2238687 bytes, checksum: f28d34b00b61c32ff388e13ceda7d2eb (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-11T20:35:54Z (GMT) No. of bitstreams: 1
Dissertação - Maira de Souza Carvalho.pdf: 2238687 bytes, checksum: f28d34b00b61c32ff388e13ceda7d2eb (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-11T20:36:53Z (GMT) No. of bitstreams: 1
Dissertação - Maira de Souza Carvalho.pdf: 2238687 bytes, checksum: f28d34b00b61c32ff388e13ceda7d2eb (MD5) / Made available in DSpace on 2015-06-11T20:36:53Z (GMT). No. of bitstreams: 1
Dissertação - Maira de Souza Carvalho.pdf: 2238687 bytes, checksum: f28d34b00b61c32ff388e13ceda7d2eb (MD5)
Previous issue date: 2014-02-21 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / The purpose of this study was to evaluate hystologically the cleaning capacity promoted by two reciprocating single-file systems the root canal system. To perform the experiment, 25 mandibular molars were selected, with mesial root canal curvature degree between 20º and 40º and radius of canal curvature ≤10 mm. Using K-type files, it was evaluated the presence of independent foramens with anatomical diameters compatible with #15 instrument. To standardize the size of the teeth in 16 mm crowns were partially sectioned. The selected specimens were divided in two experimental groups of 10 teeth each, Reciproc Group and WaveOne Group, and a Control Group, formed by 5 teeth. Then silicone blocks were prepared, which to be posted in a vise-grip, enabled the standardization of instrumentation position. The working length of the mesiobuccal canals was determined subtracting 0,5mm from apical foramen; Reciproc Group was prepared only with a R25 file in three peck motions towards the apex. The WaveOne Group used the Primary instrument, the same way formerly described. 2,5% sodium hypochlorite was used as irrigant solution, 1ml being used at each insertion of the instrument. The Control Group was uninstrumented and unirrigated. After canal preparation, the apical thirds were submitted to histological processing to obtain 15 serial transverse cross sections (5 μm), stained with hematoxylin and eosin. Histological analysis was performed by analysis of the cross-sections with 230x magnification and quantification of debris through the superposition of a grid. Data were submitted to Kruskal-Wallis test and Dunn's Multiple Comparisons Test (P = 005). The results showed no differences (P>0,05) between Reciproc (286,38) and WaveOne (325,20) Groups. In comparing the experimental groups with the Control Group (654,36), a statistically significant difference was found (P <0.001). Based on the methodology used and the results obtained, it may be concluded that there was no statistically significant difference between the the single-file and reciprocating motion systems. / O objetivo do presente estudo foi avaliar, por meio da análise histológica, a capacidade de limpeza do sistema de canais radiculares promovida por dois sistemas de lima única em movimento reciprocante. Para realização do experimento foram selecionados 25 molares inferiores com grau de curvatura da raiz mesial entre 20° e 40° e raio de curvatura ≤10 mm. Com a utilização de limas tipo K, avaliou-se a presença de forames independentes com diâmetros anatômicos compatíveis com um instrumento #15. Para padronização do tamanho dos dentes em 16 mm as coroas foram parcialmente seccionadas. Os espécimes selecionados foram divididos em dois grupos experimentais com 10 dentes cada, Grupo Reciproc e Grupo WaveOne, e um Grupo Controle, composto por 5 dentes. A seguir, foi confeccionado um bloco de silicone, que ao ser afixado em uma morsa de bancada, possibilitou a padronização da posição de instrumentação. O comprimento de trabalho dos canais mesiais foi definido a 0,5 mm aquém ao ápice, sendo o Grupo Reciproc preparado apenas com a lima R25 em três movimentos de entrada e saída em direção apical, no Grupo WaveOne utilizou-se o instrumento Primary com a mesma cinemática. Hipoclorito de sódio a 2,5% foi a solução irrigante empregada, sendo utilizado 1 ml a cada inserção do instrumento. O Grupo Controle não passou por preparo químico-mecânico e protocolo de irrigação. Após a instrumentação, o terço apical de cada espécime foi submetido ao processamento histológico de rotina para obtenção de 15 cortes com 5 μm de espessura, corados com hematoxilina e eosina. A análise histológica se deu pela avaliação das lâminas com aumento de 230x e determinação do percentual de debris por meio da superposição de uma grade de integração. Os dados obtidos foram submetidos ao teste de Kruskall-Wallis e teste de Múltiplas Comparações de Dunn (P=0,05). Os resultados mostraram não haver diferenças (P>0,05) entre Grupo Reciproc (286,38) e Grupo WaveOne (325,20). Na comparação dos grupos experimentais com o Grupo Controle (654,36), diferença estatística significante foi encontrada (P<0,001). Com base na metodologia empregada e nos resultados obtidos, conclui-se que não houve diferença estatisticamente significante entre os dois sistemas de instrumentação que empregam lima única e movimento reciprocante.
|
40 |
Análise tomográfica Cone Beam e histológica do preparo do canal radicular com três sistemas rotatórios /Moraes, Sergio Herrero. January 2010 (has links)
Orientador: Marcelo Gonçalves / Banca: Yara Teresinha Correa Silva Sousa / Banca: Ivaldo Gomes de Moraes / Banca: Fábio Luiz Camargo Villela Berbert / Banca: Mario Tanomaru Filho / Resumo: O presente estudo teve como objetivos as análise tomográfica e histológica do preparo do canal radicular com três sistemas rotatórios de NiTi: ProTaper (grupo 1), Mtwo (grupo 2) e K3 (grupo 3). Trinta e seis molares superiores foram radiografados pela técnica de tomografia cone beam (feixe cônico) antes e depois do preparo rotatório do canal mésio-vestibular. Os dentes foram pesados antes e depois do preparo para analisar a capacidade de corte dos instrumentos pela remoção de dentina. Aumento na área do canal, no alargamento do comprimento mésio-distal do canal, centralização e transporte do canal nos terços cervical, médio e apical foram analisadas nas tomografias computadorizadas transferidas para o software Canvas 11. Após o preparo dos canais radiculares as raízes foram descalcificadas, cortadas com 6 μm de espessura e coradas com hematoxilina-eosina, para exame das irregularidades das paredes de dentina do canal radicular e da presença de resíduos no canal. Para avaliar estatisticamente os resultados foi utilizado o método de variância (ANOVA).Os resultados revelaram que houve diferença estatisticamente significante entre os grupos. ProTaper removeu significativamente mais dentina do que Mtwo e K3 (p<0,05). Mtwo removeu mais do que o K3 (p<0,05). Protaper, Mtwo e K3 aumentaram significativamente a área do canal depois do preparo (p<0,05). A diferença foi significativa no terço cervical entre ProTaper e K3 (p<0,05), Mtwo e K3; terço médio entre ProTaper e K3 (p<,0,05), Mtwo e K3 (p<0,05); no terço apical entre ProTaper e K3 (p<0,05), Mtwo e K3.p<0,05). Protaper, Mtwo e K3 aumentaram significativamente o comprimento mésio-distal do canal. A diferença foi significativa entre ProTaper e K3 (p<0,05) , Mtwo e K3 nos terços cervical, médio e apical. Na avaliação da centralização do canal foi encontrada diferença significativa de desvio entre os grupos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The key goal of the present study was the histological and tomographic analysis of the root canal preparation with three NiTi rotatory systems: ProTaper (group 1), Mtwo (group 2) e K3 (group 3). Thirty six maxillary molar teeth were radiographed with the cone beam technique before and after the mesial-buccal root canal preparation. The teeth were weighted before and after preparation to analyse dentine removal capacity of the cutting instruments. Images from computed tomography were transferred to the software Canvas 11 to allow for analysis of the increase of the root canal area, the widening of the mesial-distal distance, and the root canal centring and transport in the cervical, mesial and apical thirds. After the root canal preparation, the roots were decalcified, cut to 6 μm thickness, from the cervical third to the apical one and dyed with hematoxylin-eosin. The roots were then analysed as to irregularities in the dentine wall of the root canal, and presence of any residue. The variance method (ANOVA) was used to statistically evaluate the results, which presented statistically relevant difference amongst the groups. ProTaper removed dentine more significantly than Mtwo and K3 (p<0,05). Mtwo removed more than K3 (p<0,05). All groups presented significant increase in the area of the root canal after preparation (p<0,05), mainly in the cervical third and the apical third. Cervical third the difference was ProTaper and K3 (p<0,05), Mtwo and K3, and in the apical third the difference was ProTaper and K3 (p<0,05), Mtwo and K3 (p<0,05). Protaper, Mtwo e K3 significantly increased the mesial-distal distance... (Complete abstract click electronic access below) / Doutor
|
Page generated in 0.1546 seconds