1 |
The Promotion of the Performance Based on Dual Sagnac Interferometer HydrophonesChen, Han-Yang 08 August 2006 (has links)
An interferometer is used for phase detection. Thus, the hydrophone which is based on interferometric optic fiber sensor has extremely high sensitivity. Sagnac interferometric hydrophone has low noise of marine environment, which is more suitably used to detect underwater acoustic signal than that of a Mach-Zehnder interferometer. In this paper, a configuration of dual Sagnac interferometer was proposed. The mathematical model was derived and analyzed.
The fiber optic sensor head contains mandrel type and planar one. The acoustic window are made of silicon rubbers. It was should that we can increase their sensitivities by increase number of wrapping fiber coils.
In our experiment, the result shows that among all the mandrel sensor heads, the most highest dynamic range is up to 37.6¡Ó1.4 dB, and its sensitivity is -223.3¡Ó1.7 dB re V/1µPa ; while the dynamic range of the planar sensor head is 42.1¡Ó1.5 dB, and its sensitivity is -213.8¡Ó1.3 dB re V/1µPa¡C
As for the configuration of the optical interferometers, the intensity of the dual Sagnac interferometer is 20 dB larger than its Sagnac counterpart. Its dynamic range is above 66 dB, which is 24 dB larger than that of the Sagnac interferometer with the sensitivity of -192.0 dB re
V/1µPa. In addition, by using software simulation to design optimal lengths of delay fibers , we can increase interferometer¡¦s the dynamic range of underwater acoustic detection. This paper verify that, by means of adjusting the length of these two delay fibers, we can actually increase the dynamic range of acoustic signal detection.
|
2 |
Fiber-Optic Distributed Sensor System for the Detection of the Leakage of Gas PipelinesMeng-Tsan, Tsai 10 July 2002 (has links)
This system is designed to detect the leakage position of gas pipelines. By Sagnac
interferometric theory, we develop the hybrid configuration of Mach-Zehnder and Sagnac Interferometer. It contains the properties of Sagnac Interferometer and it is easy to spread the fiber on the pipelines. When the leakage happened, it will generate the sound signal. This kind of sound pressure will make the total fiber length changed, and hence it will make phase difference. By getting the phase difference, we will get the information of leakage position. After a series of experiments, we prove our theory is correct and we can get an accurate position.
The Dynamic range of the system is more than 75 dB. The smallest signal that can be detected is about 3.345x10^-4(rad/Hz).
|
3 |
The Design and Demodulation of Fiber-optic Hydrophones Based on Dual Sagnac InterferometersHuang, Guo-ting 08 September 2004 (has links)
Because the acoustic wave is capable of propagating at a long-distance in water, the hydrophone plays a key role in the underwater acoustic sensing all the time. The hydrophone based on fiber optic interferometry has an extremely high sensitivity and large dynamic range. In addition, the electrically passive, immunity to electromagnetic interference, and multiplexing properties of fiber optic sensor offer great advantages over traditional piezoelectric hydrophone.
Due to the complete path-balance between the two counterpropagating waves, a Sagnac interferometric configuration can employ a low-coherent light source to reduce the cost. This configuration can easily route optical paths and replace sensor heads to compare with each other. But, the sensitivity varying with frequency and the polarization-induced signal fading problem make it unsuitable for applications in need of detecting correct amplitude of signals. The Michelson interferometric configuration with Farady rotator mirror (FRM) has a constant sensitivity and solves the polarization-induced signal fading problem. But, this configuration uses a high-coherent light source and expensive FRMs, and be difficult to route. In this paper, we use the polarization-insensitive Michelson fiber optic sensor to adjust the demodulation circuits we design.
In this paper, we establish the interferometric hydrophones. The fiber optic coil of the sensor head is embedded with the special materials in order to acoustic impedance matching and waterproofing. We employ phase generated carrier demodulation technology to get the acoustic signal of interest from the output of the interferometer. In our experiment, the dual Sagnac configuration has a dynamic range of 23 dB and a sensitivity of -226 dB re V/1uPa, the Michelson configuration with FRMs has a dynamic range of 25 dB and a sensitivity of -204 dB re V/1uPa.
|
4 |
The study of time- division multiplexed fiber-optic current sensing systemsHuang, Ji-Yao 09 July 2003 (has links)
In this essay, we developed an environmental immunity of multiplexed In-line sagnac interferometric fiber-optic current sensing system. The multiplexedwas used the time-division technique, were proposed to meet this research objective. The theoretical inference and experimental results were presented. The experimental results the system have sensitivity 56£gV/A¡Eturns, and the signal to noise ratio is 70dB. Besides, the multiplexed sensed two current in the same time, those two responses are still linearity. The uniform of these multiplex sensed are less than 2%. The system is hysteresis-free operator, no saturation limit. These features are suit for fiber-optic current sensor in measuring large range variable current. The current waveform can be read directly. In this research, the result let the fiber-optic current sensor approach to application on industrial power delivery line and monitor more current by this system.
|
5 |
Creating and Imaging Surface Acoustic Waves on GaAsMathew, Reuble 08 December 2009 (has links)
The versatility of surface acoustic wave (SAW) devices stems from the accessibility of the propagation path to modification and detection. This has led to the integration of SAWs in a variety of novel fields, including quantum information processing.
The development of technologically competitive devices requires the use of gigahertz frequency SAWs. This thesis develops fabrication processes for high frequency interdigital transducers on gallium arsenide. Optically lithography was used to create linear and stepped transducers, with a minimum feature size of 2 um, that were driven at their fifth harmonic. The highest frequency achieved was 1435 MHz, but the power absorbed was less than 3% and insertion losses were greater than -80 dB. Further improvements in the design and fabrication are required if optically fabricated transducers are to be an alternative to transducers with narrower finger widths. Electron-beam lithography techniques were developed and used to create transducers with finger widths of 500 and 400 nm, with fundamental resonance frequencies of 1387 and 1744 MHz, respectively. The power absorbed was 3 to 6% with insertion losses greater than -45 dB. The performance characteristics can be improved by the removal of residual resist on the surface of the transducer.
An indispensable tool for the characterization of one-port transducers is an all optical probe to measure the displacement field of a SAW. This work details the design and construction of a scanning Sagnac interferometer, that is capable of measuring the outward displacement of a surface. The spatial resolution of the interferometer was 2.4 +/- 0.2 um and the displacement sensitivity was determined to be 4 +/- 1 pm. The instrument was used to map the SAW displacement field from a 358 MHz transducer, with results showing the resonant cavity behaviour of the fingers due to Bragg reflections. It also allowed for the direct detection of the SAW amplitude as a function of the driving frequency of the transducer. The results showed good agreement with the related S21 scattering parameter. Lastly, the interferometer was used to image the attenuated propagation of SAWs through a phononic crystal. Results showed good agreement with theoretical simulations. / Thesis (Master, Physics, Engineering Physics and Astronomy) -- Queen's University, 2009-12-08 12:28:35.962
|
6 |
Automatically phase-locked fibre optic electronic speckle pattern interferometry using laser vibrometryHarvey, David January 1996 (has links)
No description available.
|
7 |
Phononic Crystal Waveguiding in GaAsAzodi Aval, Golnaz 29 November 2013 (has links)
Compared to the much more common photonic crystals that are used to manipulate light, phononic crystals (PnCs) with inclusions in a lattice can be used to manipulate sound. While trying to propagate in a periodically structured media, acoustic waves may experience geometries in which propagation forward is totally forbidden. Furthermore, defects in the periodicity can be used to confine acoustic waves to follow complicated routes on a wavelength scale. Using advanced fabrication methods, we aim to implement these structures to control surface acoustic wave (SAW) propagation on the piezoelectric surface and eventually interact SAWs with quantum structures.
To investigate the interaction of SAWs with periodic elastic structures, SAW interdigital transducers (IDTs) and PnC fabrication procedures were developed. GaAs is chosen as a piezoelectric substrate for SAWs propagation. Lift-off photolithography processes were used to fabricate IDTs with finger widths as low as 1.5 micron.
PnCs are periodic structures of shallow air holes created in GaAs substrate by means of a wet-etching process. The PnCs are square lattices with lattice constants of 8 and 4 micron. To predict the behavior of a SAW when interacting with the PnC structures, an FDTD simulator was used to calculate the band structures and SAW wave displacement on the crystal surface. The bandgap (BG) predicted for the 8 micron crystal ranges from 180 MHz to 220 MHz. Simulations show a shift in the BG position for 4 micron crystals ranging from 391 to 439 MHz.
Two main waveguide geometries were considered in this work: a simple line waveguide and a funneling entrance line waveguide. Simulations indicated an increase in acoustic power density for the funneling waveguides. Fabricated device evaluated with electrical measurements. In addition, a scanning Sagnac interferometer is used to map the energy density of the SAWs. The Sagnac interferometer is designed to measure the outward displacement of a surface due to the SAW. Interferometric measurements confirmed waveguiding in the modified funnel entrance waveguide embedded in the 4 micron PnC. However, they also revealed strong dissipation of the SAW in the waveguide due to the non-vertical sidewalls resulting from the wet-etch process. / Thesis (Master, Physics, Engineering Physics and Astronomy) -- Queen's University, 2013-11-29 15:53:46.369
|
8 |
The Novel Sagnac Interferometer for Designing HydrophonesCheng, Bi-Chang 19 August 2004 (has links)
The main purpose of the optical fiber sensing technology is to detect perturbation of physical fields. By means of some demodulating scheme, we can extract the real signal from those light beams which modified by physical fields. In the thesis, we proposed a configuration of modified Sagnac Interferometer as a sensing system. The optical sensing and demodulation system are exploited separately. Next, we study the advantages and disadvantages of the configuration. Besides, we are also measured the sensitivity and dynamic range.
The sensing system used a low coherence light source to reduce cost. This system also improves the shortage of a Sagnac Interferometer which has a blind point in the middle position. In addition, the structure is easily implemented and can detect weak signal in a high noisy water environment.
For matching the main structure, we make many kinds of sensing heads for detecting signals under water. We also use the mathematical model as the base of the theory. The dynamic range is 40 dB and the sensitivity is -231.47 dB re V/uPa.
|
9 |
The Configuration Analysis of Interferometric HydrophonesWu, Tzu-wei 04 September 2004 (has links)
The interferometeric optical fiber sensor has high sensitivity for sound signal. This characteristic is used to design hydrophones. The sound pressure causes the optical fiber to change its shape. So as to induce phase difference between sensing and reference arms. Using the demodulation system, we can get the signal we want. In this thesis, we plan to analyze three different kinds of optic configurations, such as Michelson, compensating Mach-Zehnder, hybrid configuration of Mach-Zehnder and Sagnac interferometers. The mathematical methods are used to compare their characters. We also use software to simulate the relation among sensitivity, delay fiber and frequency character of the Sagnac interferometer.
In our experiment, we use PGC modulation technology and compare the results with a standard hydrophone B&K 8103 for calibration. We also measure the dynamic range of proposed three interferometers. The measurement result of this paper is as following: Michelson and compensating type Mach-Zehnder interferometer dynamic range were about 24.90 dB and 13.98 dB, the acoustic signal sensitivity was -201.67 dB re V/1uPa and -205.97 dB re V/Pa, respectively. The dynamic range of the hybrid of Mach-Zehnder and Sagnac type interferometer was 33.67 dB and acoustic signal sensitivity was -212.47 dB re V/1uPa.
|
10 |
A Study of the Fiber Optic Leak DetectorHuang, Jian-Dau 17 July 2000 (has links)
non
|
Page generated in 0.0406 seconds