• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 438
  • 96
  • 27
  • 22
  • 21
  • 21
  • 21
  • 19
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 571
  • 332
  • 192
  • 143
  • 110
  • 91
  • 81
  • 67
  • 64
  • 57
  • 56
  • 49
  • 48
  • 46
  • 40
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

A relação entre cancelamento de fluxo magnético e fulgurações solares

Livi, Silvia Helena Becker January 1994 (has links)
As fulgurações têm sido estudadas há muito tempo e continuam intrigando os cientistas solares. Nosso trabalho trata da relação entre fulgurações e cancelamento de fluxo. O cancelamento é um fenômeno observacional descoberto usando séries de magnetogramas na linha de visada, que consiste na aproximação e posterior desaparecimento de fluxo magnético nas zonas em que polaridades magnéticas opostas estão em aparente contato e mantém um alto gradiente de campo magnético. / Flares have been studied for a long time and continue to puzzle solar scientists. Our work is on the relationship between flares and flux cancellation. Flux cancellation is an observational phenomena discovered using series os magnetograms of the line-of-sight component. It consists of the encounter and further disappearance of magnetic flux where opposite magnetic polarities are in apparent contact with each other and maintain a high gradient of magnetic field.
72

Estudo e caracterização de novos corantes naturais para aplicação em células solares sensibilizadas / Study and characterization of new natural dyes for application in sensitized solar cells

Sampaio, Samuel Gondim January 2014 (has links)
SAMPAIO, S. G. Estudo e caracterização de novos corantes naturais para aplicação em células solares sensibilizadas. 2014. 96 f. Dissertação (Mestrado em Engenharia Mecânica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2014-04-03T17:43:46Z No. of bitstreams: 1 2014_dis_sgsampaio.pdf: 1706262 bytes, checksum: 9b40ac3c030adac051d00efc0407c648 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2014-05-07T19:26:32Z (GMT) No. of bitstreams: 1 2014_dis_sgsampaio.pdf: 1706262 bytes, checksum: 9b40ac3c030adac051d00efc0407c648 (MD5) / Made available in DSpace on 2014-05-07T19:26:32Z (GMT). No. of bitstreams: 1 2014_dis_sgsampaio.pdf: 1706262 bytes, checksum: 9b40ac3c030adac051d00efc0407c648 (MD5) Previous issue date: 2014 / This paper presents a study and characterization of dyes with flowers of plants collected in the Northeast of Brazil, such as Sida cordifolia (malva branca), the Catharanthus roseus (boa noite), Torenia fournieri (amor-perfeito-de-verão), Alamanda cathartic (alamanda da flor grande) and Cobaea scandens (sino de catedral). Was studied and observed the influence of flavonoids in the sensitization of natural dyes by means of a prototype solar cell with conductive film with a glass of SnO2: F produced by spray pyrolysis. The conductive glass was obtained precursor solution (HCl/H2O) containing of tin II chloride dihydrate (SnCl2.2H2O), ammonium fluoride (NH4F) and a slide glass heated to 600 ° C. The solution was sprayed on the heated substrate. About conductive glass was deposited a layer of titanium dioxide (TiO2). The layer was obtained by dissolving in commercial TiO2 powder acetic acid (CH3CO2H) and Triton X. The electrolyte was a solution of iodine / triiodide into the intracellular regeneration cycle, the counter electrode was a layer made of graphite. The plants were treated with a by washing with deionized water, drying with heat gun and Silica Gel to absorb moisture. Were macerated and immersed in an organic solvent. After a few days, were concentrated in a rotary evaporator at a speed 160 rpm at room temperature for 40 minutes. This dye was applied on the TiO2 layer and then the cell was tested under sunlight. The values obtained were: Torenia fournieri, short-circuit current = 0.44 mA and open circuit voltage V = 0.16; Catharanthus roseus, short-circuit current = 0.43 mA = 0 and open-circuit voltage, 14 V, Sida cordifolia, short-circuit current = 0.22 mA and open circuit voltage V = 0.19; Allamanda cathartic, short-circuit current = 0.19 mA and open circuit voltage V = 0.12; Cobaea scandens, short-circuit current = 0.32 mA and open circuit voltage = 0.17 V. These results may provide more data for better understanding and use of new natural dyes in solar cells. / Este trabalho apresenta um estudo e caracterização de corantes com flores de plantas coletadas na região Nordeste do Brasil, tais como: a Sida cordifolia (malva branca), a Catharanthus roseus (boa noite) e a Torenia fournieri (amor-perfeito-de-verão), Allamanda catártica (alamanda da flor grande) e Cobaea scandens (sino de catedral). Foi estudado e observado a influência dos flavonoides na sensibilização dos corantes naturais por meio de um protótipo de célula fotovoltaica, com vidros condutores com um filme de SnO2:F produzidos por spray Pirólise. As plantas foram submetidas a um tratamento de lavagem. Foram maceradas e imersas em um solvente extrator. Após alguns dias, foram concentradas no rotaevaporador a uma velocidade 160 rpm em temperatura ambiente por 40 minutos. Este corante foi aplicado sobre uma camada de TiO2 e então a célula foi testada sob a luz solar. Os valores obtidos foram: Torenia fournieri, corrente de curto-circuito = 0,44 mA e tensão de circuito aberto = 0,16 V; Catharanthus roseus, corrente de curto-circuito = 0,43 mA e tensão de circuito aberto = 0,14 V; Sida cordifolia, corrente de curto-circuito = 0,22 mA e tensão de circuito aberto = 0,19 V; Allamanda catártica, corrente de curto-circuito = 0,19 mA e tensão de circuito aberto = 0,12V; Cobaea scandens, corrente de curto-circuito = 0,32 mA e tensão de circuito aberto = 0,17V. Estes resultados podem fornecer mais dados para melhor entendimento e uso de novos corantes naturais em células solares.
73

Automação e otimização energética de uma unidade de aquecimento solar doméstica

Pasetti, Gelson Onir January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Automação e Sistemas, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:21:57Z (GMT). No. of bitstreams: 1 329171.pdf: 3158116 bytes, checksum: f50218dc87a2d867fe1ced6ac4de9cf7 (MD5) Previous issue date: 2014 / Este trabalho aborda o aumento da eficiência energética de uma unidade de aquecimento de água para o banho, uma vez que 24% do consumo energético no setor doméstico é utilizado para esse fim. Além disso, o chuveiro elétrico, que está presente em aproximadamente 73% das residências brasileiras, é o principal responsável pelo pico da demanda energética que ocorre entre as 18h e 21h. Diante disso, propõe-se um sistema de aquecimento híbrido, que utiliza como fontes de energia a solar e a elétrica. O sistema é composto basicamente por coletores solares, um tanque de armazenamento e um chuveiro elétrico. Válvulas automáticas e controladores de potência são inseridos na planta para regular as temperaturas da água do boiler e do chuveiro e as vazões de água quente e fria durante o banho. Um microcontrolador é responsável por controlar todo o sistema, a fim de atender aos requisitos (temperatura e vazão do banho) definidos pelo usuário. O ajuste da abertura das válvulas e da potência do chuveiro é feito de forma automática, aumentando o conforto do usuário. Para garantir que a planta solar híbrida irá operar de forma a minimizar o consumo de energia elétrica e reduzir o erro de seguimento a referência, foi desenvolvida uma função de otimização. Como essa função requer uma grande capacidade de processamento, um algoritmo de controle sub-ótimo foi criado para que pudesse ser utilizado em microcontroladores mais simples e baratos. O sistema híbrido foi modelado matematicamente e as expressões foram validadas utilizando os dados adquiridos em um protótipo construído em Florianópolis, Santa Catarina. Testes de campo e simulações comprovaram que o sistema proposto é economicamente viável, economizando expressivas quantidades de energia elétrica e água se comparado aos sistemas tradicionais. Ao tomar como base a média anual do clima de Florianópolis, a planta solar híbrida é capaz de reduzir o consumo de energia elétrica em mais de 78%. Além disso, o sistema solar proposto, se comparado a uma planta solar tradicional, evita o desperdício do volume de água que fica acumulado no encanamento entre o boiler e o chuveiro, o que pode representar uma economia superior a 4 mil litros de água por ano para uma família com quatro pessoas.<br> / Abstract : This work addresses the increasing energy eciency of a heating waterunit for bath. This motivation is based on the fact that 24% of energyconsumption in the domestic sector is used for this purpose. Moreover,the electric shower, which is used in approximately 73% of Brazilianresidences, is the main responsible for the peak energy demand thatoccurs between 18h and 21h. Therefore, a hybrid heating system usingsolar and electric energy is proposed. The system is basically composedof solar collectors, a storage tank and an electric shower. Automaticvalves and power controllers are used in the plant to regulate watertemperature inside the boiler and in the shower, and to control hot andcold ow rates during bath. A microcontroller is responsible to controlthe entire system, in order to meet the requirements (bath temperatureand water ow) dened by the user. The adjustment of valveopening and shower power is done automatically, enhancing the comfortfor the user. To ensure that the hybrid solar plant will operate tominimize energy consumption and reduce the reference tracking error,an optimization function was developed. Since this function requiresa large processing capacity, a suboptimal control algorithm was createdso it could be used in simpler and cheaper microcontrollers. Thehybrid system was mathematically modeled and expressions were validatedusing data acquired on a prototype built in Florianopolis, SantaCatarina. Field tests and simulations showed that the proposed systemis economically viable, saving signicant amount of energy and watercompared to traditional systems. Based on the annual average of theclimate in Florianopolis, the hybrid solar plant is able to reduce energyconsumption by more than 78%. Moreover, the proposed solar system,compared to a traditional solar plant, avoids wasting the volume ofwater that gets accumulated in the pipeline between the boiler and theshower, which may represent an economy greater than 4000 liters ofwater per year, considering a family with four people.
74

Aquecedor solar de água integrado ao telhado

Silva, Roberta Costa Ribeiro da January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:56:13Z (GMT). No. of bitstreams: 1 331136.pdf: 6758512 bytes, checksum: 3b5b8004e6f65fa5b335d840695bc543 (MD5) Previous issue date: 2014 / A busca por uma tecnologia que contribua para a real introdução do aproveitamento da energia solar no cotidiano das pessoas de modo integrado à edificação, bem como, a otimização de soluções em produtos finais na área da construção civil, impulsionaram as ideias que serão desenvolvidas neste trabalho. A materialização destas aspirações é apresentada por meio de um modelo de aquecedor solar com algumas particularidades que o diferenciam dos existentes no mercado. Estas diferenças estão baseadas na inserção do mesmo nos telhados convencionais que se utilizam de telhas cerâmicas e de fibrocimento e nos princípios de funcionamento que resultam na sua forma final. A ideia de inserção, foco do trabalho, consiste na proposta de módulos projetados para servirem não só como coletores solares, mas também como reservatório da água quente, dispensando o espaço extra no telhado para seu armazenamento, diferenciando-se dos sistemas existentes por integrar os módulos às particularidades das estruturas de madeira, e fazendo o papel de cobertura nestas regiões, não sendo necessário o uso das telhas. A forma que materializa o aquecedor está fundamentada em características dos materiais empregados, constatadas pela ciência em relação ao seu comportamento diante da radiação solar. O principal deles, é o Glass Fiber Reinforced Concrete (GFRC) que funcionará como irradiador de calor para o líquido por atraso térmico, proporcionando que a reserva de água quente fique dentro dos módulos, para que se possa assim, dispensar o reservatório. O resultado apresenta uma nova forma de pensar a configuração das coberturas estudadas de modo otimizado e harmônico. A proposta de projeto do aquecedor integra-se aos telhados estudados, com dois módulos atendendo ao volume de água por pessoa, com instalação e manutenção simples, sem que seu peso acarrete em sobrecarga nas estruturas de madeira e com possibilidade de custo competitivo com os modelos existentes no mercado. A ideia desenvolvida nesta dissertação possui pedido de patente registrado junto ao Instituto Nacional da Propriedade Industrial (INPI).<br> / Abstract : The search for a technology which contributes for an actual effort to start using solar energy in people?s daily lives, integrated to construction in general, as well as for the optimization of solutions producing materials for construction and engineering, have stimulated the ideas which are going to be presented in this work. Such aspirations resulted in a model of solar heater with a few peculiarities, that make it different from the others available on the market. Those differences can be denoted by its installation on regular roofs, built with ceramic or fiber cement roof tiles, and by the way it works, which establish its main characteristics. This piece of work is focused on the proposal in which the modules are projected to not only be solar beam concentrators but also hot water reservoirs, dismissing the need for extra room for its stocking, different from what is today available, since it integrates the modules to the particularities of the regular wooden structures of roofs, replacing the tiles on the spot where it?s installed. The main characteristics of this solar heater is are due to the characteristics of the materials used in its construction, properly tested in relation to the effects caused on them by the solar radiation. The main raw material is Glass Fiber Reinforced Concrete (GFRC), which irradiates the heat to the water by thermal delay, thus the hot water stock will stay inside the modules, in a way its not necessary to keep a tank to stock the hot water. It resulted in a new, harmonic and optimized way to think and conceive heaters and roofs. The project is about the installation of two modules, which is simple as well as its maintenance, supplying the amount of water needed per person, without overloading the structures of the roof, at a competitive price in relation to what is currently available on the market. The patent of this project has been required at the Instituto Nacional da Propriedade Industrial (INPI).
75

Síntese e caracterização de complexos de rutênio para aplicação em células solares sensibilizadas por corante / Synthesis and characterization of ruthenium complexes for application in Dye-Sensitized Solar Cells

Lima, Paula Aragão January 2012 (has links)
LIMA, P. A. Síntese e caracterização de complexos de rutênio para aplicação em células solares sensibilizadas por corante. 2012. 70 f. Dissertação (Mestrado em Química) - Centro de Ciências, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Daniel Eduardo Alencar da Silva (dealencar.silva@gmail.com) on 2014-11-26T23:34:34Z No. of bitstreams: 1 2012_dis_palima.pdf: 1750850 bytes, checksum: f0936c03fba536ccd27489c0db17e580 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa(jairo@ufc.br) on 2016-01-25T20:04:23Z (GMT) No. of bitstreams: 1 2012_dis_palima.pdf: 1750850 bytes, checksum: f0936c03fba536ccd27489c0db17e580 (MD5) / Made available in DSpace on 2016-01-25T20:04:23Z (GMT). No. of bitstreams: 1 2012_dis_palima.pdf: 1750850 bytes, checksum: f0936c03fba536ccd27489c0db17e580 (MD5) Previous issue date: 2012 / Dye-Sensitized Solar Cells (DSSCs) are devices capable of converting light into electricity. DSSCs are based on the absorption of light by a dye, which injects electrons into the conduction band of a semiconductor. This study aims to synthesize, characterize and employ as sensitizers the complexes [Ru(dcbpy)(bpy)(bqdi)], [Ru(dcbpy)(bpy)(bqdi-Cl)] and cis-[Ru(H2dcbpy)(bpy)(nic)Cl]PF6, where H2dcbpy and dcbpy are, respectively, 4,4’-dicarboxy-2,2’-bipyridine and its deprotonated form, bpy is 2,2’-bipyridine, bqdi is 1,2-benzoquinonediimine, bqdi-Cl is 4-chloro-1,2-benzoquinonediimine and nic is nicotinamide. The complexes were characterized by spectroscopic and electrochemical techniques. These complexes showed broad metal-to-ligand charge transfer (MLCT) absorptions bands at about 520 nm. 1H NMR spectra for the compounds with bqdi and bqdi-Cl showed peaks consistent with the respective oxidized form. Cyclic voltammetry showed a significant positive shift in redox potential for the RuIII/II redox couple in comparison to the starting material. The photovoltaic performances of the solar cells based on these complexes are under investigation. The results for the sensitizers [Ru(dcbpy)(bpy)(bqdi)] and [Ru(dcbpy)(bpy)(bqdi-Cl)] were not promising. On the other hand, the results for cis-[Ru(H2dcbpy)(bpy)(nic)Cl]PF6 revealed a short-circuit current density of 2.4 mA cm-2, an open-circuit voltage of 610 mV and a fill factor of 0.73 under standard AM 1.5 sunlight. These results were lower than that obtained to N3, but it shows that this complex needs further investigation. / Os objetivos deste trabalho foram sintetizar, caracterizar e empregar como corantes sensibilizadores os complexos [Ru(dcbpy)(bpy)(bqdi)], [Ru(dcbpy)(bpy)(bqdi-Cl)] e cis-[Ru(H2dcbpy)(bpy)(nic)Cl]PF6, em que H2dcbpy e dcbpy são, respectivamente, o ligante 4,4’-dicarboxi-2,2’-bipiridina e sua forma deprotonada, bpy é 2,2’-bipiridina, bqdi é 1,2-benzoquinonadiimina, bqdi-Cl é 4-cloro-1,2-benzoquinonadiimina e nic é nicotinamida. Os complexos sintetizados foram caracterizados por técnicas espectroscópicas e eletroquímica. Os espectros UV-vis apresentaram bandas na região do visível (aproximadamente 520 nm) atribuídas a transições do tipo MLCT com máximos diferentes do complexo de partida devido à modificação da esfera de coordenação. Os espectros vibracionais na região do infravermelho mostraram bandas características do composto de partida e dos ligantes. Os espectros de RMN 1H obtidos para os compostos com bqdi e bqdi-Cl mostraram sinais referentes aos prótons destes ligantes coordenados na forma oxidada. A voltametria cíclica mostrou processos relativos ao par redox RuIII/II positivamente deslocados em relação ao composto de partida, apresentando-se irreversíveis para os complexos contendo os ligantes bqdi e bqdi-Cl e quasi-reversível para o complexo de nicotinamida. Foram montadas DSSCs utilizando os complexos sintetizados como sensibilizadores. Para os complexos [Ru(dcbpy)(bpy)(bqdi)] e [Ru(dcbpy)(bpy)(bqdi-Cl)], observou-se que não houve conversão de luz em corrente elétrica. Para o complexo cis-[Ru(H2dcbpy)(bpy)(nic)Cl]PF6, verificou-se um potencial de circuito aberto de 610 mV, uma corrente de curto-circuito de 2,4 mA cm-2 e um fator de preenchimento de 0,73. Estes valores são inferiores aos obtidos para o corante N3 nas mesmas condições experimentais, mas são indicativos promissores que demonstram que este complexo deve ser melhor investigado como sensibilizador em Células Solares Sensibilizadas por Corante.
76

Estudio de localización para el empleo de energía solar térmica de generación eléctrica en localidades de las regiones de Antofagasta, Atacama y Coquimbo

Jiménez Núñez, Andrea Alicia January 2017 (has links)
Ingeniera Civil Mecánica / El trabajo de título consiste en el estudio de localización de Centrales Solares Térmicas con generación de electricidad utilizando Ciclo de Rankine. La potencia de trabajo es de 25 [MW] y las centrales se sitúan en cinco localidades a especificar entre las regiones de Antofagasta, Atacama y Coquimbo, ya que estas zonas poseen mayor recurso solar, el cual se puede comprobar mediante el Explorador Solar de la Universidad de Chile, página web que tiene información histórica de la irradiancia en todo Chile. Las centrales del estudio de localización deben operar 24 horas todos los días del año, con 25% de energía solar térmica como mínimo y el resto con energía de respaldo o de apoyo, en las que se permiten escoger entre Energías Convencionales y Energías Renovables No Convencionales (ERNC), cuya decisión final fue usar las energías ERNC como Biomasa, Eólica y Mareomotriz. Las centrales pueden ser de Tipo Torre o con Colectores Cilindro-Parabólicos, ya que estas tecnologías presentan mayor madurez respecto a las otras existentes, en las que solo se han investigado y no han operado comercialmente. Todo el estudio realizado indicó que uno de los parámetros más relevantes para el emplazamiento de una central termosolar con generación de electricidad junto con la intensidad de radiación solar es el relieve de la superficie y el recurso hídrico. Otros parámetros importantes estudiados fueron: redes viales, centros poblados, planes reguladores vigentes, etc.
77

Arquitetura Solarenga rural de Campos dos Goytacazes no seculo XIX: uma analise historica e tipologica.

CHAGAS, H. N. 13 December 2010 (has links)
Made available in DSpace on 2016-08-26T15:18:45Z (GMT). No. of bitstreams: 1 tese_3810_Dissertação Humberto - Texto Completo.pdf: 42921672 bytes, checksum: 7dd5cc9d2ad9e1f6bfce3463274b3596 (MD5) Previous issue date: 2010-12-13 / Com a descoberta do Brasil pelos portugueses no século XVI, se tem início dentre outras agriculturas a da cana-de-açúcar. Desde então, alguns locais despontaram como principais produtores, tendo se destacado logo nos primeiros séculos as capitanias de Pernambuco e São Tomé, esta última hoje parte do Estado do Rio de Janeiro. Esta agricultura trouxe consigo a construção de inúmeros engenhos de açúcar e demais instalações necessárias ao bom desempenho destas atividades, tendo destaque as casas grandes dos senhores de engenho. A presente pesquisa pretende discutir as tipologias encontradas em três solares remanescentes destes engenhos de açúcar na região de Campos dos Goytacazes, construídos no século XIX, através do cadastramento, levantamento histórico e iconográfico destas edificações. Tem como objetivo geral colaborar no fomento à preservação do patrimônio edificado na cidade de Campos dos Goytacazes e região, demonstrando a relevância histórica destes antigos engenhos de açúcar, que apesar de se tratarem de imóveis tombados pelo patrimônio histórico nacional, não se encontram com documentação informativa sistematizada. Entende-se que seja importante para a pretensão da permanência de um registro vivo da arquitetura rural da região de Campos dos Goytacazes, a preservação destas edificações, que contribuirão para a constituição de um modelo construtivo, histórico e estilístico dos solares de engenhos de açúcar da região norte do estado do Rio de Janeiro. Palavras-chave: Solares Rurais; Cana-de-açúcar; Campos dos Goytacazes
78

Transferência eletrônica em sistemas moleculares

Velasco Villamizar, David January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Física, Florianópolis, 2012 / Made available in DSpace on 2013-06-25T18:30:16Z (GMT). No. of bitstreams: 1 313601.pdf: 4138516 bytes, checksum: 59e55a9c07eb3ddd5ac2b175a6a33af6 (MD5) / O presente trabalho apresenta uma análise teórica do fenômeno de transferência eletrônica (ET) para dois sistemas moleculares. Inicialmente é apresentada uma breve introdução sobre o processo de transferência eletrônica, seguida de uma descrição de seu papel em dispositivos fotovoltaicos orgânicos e poliméricos. Prossegue-se com uma descrição detalhada da teoria usada nesta dissertação e das diferentes técnicas computacionais utilizadas para realizar a propagação temporal de pacotes de onda eletrônicos em sistemas moleculares. Dois modelos físicos são investigados pelo formalismo. No primeiro caso apresenta-se uma análise do fenômeno de transferência eletrônica em um sistema doador-aceitador assistido por ponte: dois átomos de berílio atuam como o par doado-aceitador, para os quais a transferência é intermediada por uma estrutura molecular rígida (cadeia de polietileno) C17H36. Examinou-se as consequência para a transferência dos diferentes comprimentos de ligação que conectam doador e aceitador com a ponte, e a variação do número de unidades de etileno na ponte. Os cálculos demonstram a transição entre a transferência de carácter ôhmico e a super-trânsferência, em acordo com outros formalismos. O segundo modelo de estudo consiste de uma cadeia triatômica dinâmica idealizada para a investigação dos efeitos do movimento iônico sobre a dinâmica eletrônica. Fica evidenciado que em frequências nucleares baixas a dinâmica eletrônica é de carácter adiabático. Em contrapartida, frequências maiores conduzem à efeitos de carácter não adiabático.<br> / Abstract : This work presents a theoretical analysis of the electron transfer process for two types of molecular systems. It begins with a brief introduction about the electron transfer process, which is followed by a discussion about the relevance of the process to the operation of organic and polymeric photovoltaic devices. In the sequence, the relevant theory is explained in detail, particularly the computational methods that are used to time propagate electronic wavepackets in molecular structures. Two physical models are investigated with the formalism. In the first case, the analysis of the electron transfer mechanism is carried for a donor-acceptor system coupled by a bridge: two beryllium atoms act as the donor-acceptor pair, and the electronic transfer takes place through a rigid molecular structure (polyethylene chain) C17H36. The effects caused by changing bond lengths between donor/acceptor sites and the bridge as well as varying the number of ethylene units in the bridge were investigated. The calculations show a transition of the transfer behaviour from ohmic to super-exchange, in accordance with predictions made by different formalisms. The second model system consists of a tri-atomic dynamic chain, which is thought for studying the effects of the ionic motion on the electronic dynamics. The present study shows that the electronic dynamics is adiabatic at low nuclear frequencies whereas at high nuclear frequencies non-adiabatic effects arise.
79

Análise experimental de um sistema solar com concentrador cilindro parabólico

Pigozzo Filho, Victor César January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2013 / Made available in DSpace on 2013-12-05T22:02:23Z (GMT). No. of bitstreams: 1 319742.pdf: 2707493 bytes, checksum: 784586559c476181ee8f41253b7b4a60 (MD5) Previous issue date: 2013 / Neste trabalho foi realizado um estudo experimental de um coletor solar cilindro parabólico, com 4m de comprimento e 3m de largura, operando em Florianópolis, Santa Catarina. O projeto e construção do coletor também foram realizados durante este trabalho. O fluido de trabalho utilizado foi água destilada, com vazões variando de 0,05 kg/s a 0,3 kg/s. A temperatura de operação variou entre a temperatura ambiente, 25°C, até 150°C e a pressão dos testes foi mantida entre 4 e 6 bar. O concentrador cilindro parabólico é equipado com elementos absorvedores com recobrimento seletivo e isolamento térmico evacuado. O diâmetro interno dos elementos absorvedores, por onde escoa a água é de 67 mm, semelhante ao utilizado em centrais solares de grande porte. Dados de radiação solar global e direta foram realizados durante os testes e confrontados com os resultados das medições realizadas no coletor. Com isso obteve-se os parâmetros de rendimento global e ótico do coletor. Foram realizados também testes de perdas térmicas para se obter um coeficiente global de perdas de calor e assim o rendimento térmico. <br> / Abstract: At the present work, an experimental analysis of a parabolic trough solar collector, which is 4m long and 3m wide, was carried out at the city of Florianópolis, Santa Catarina, Brazil. In this work the project and the assembly of the collector were entirely done. Tests were carried out with water as the working fluid. The water mass flow rate ranged from 0,05 kg/s to 0,3kg/s. The temperature of operation ranged between the ambient temperature, 25°C, until 150°C, and the pressure was maintained between 4 and 6 bar. The parabolic trough collector is equipped with heat collector element recovered with selective coating and with vacuum for thermal insulation. The inner diameter of the heat collector element, where the water flows, is 67mm, the same used in commercial scale solar power plants. Direct and global solar radiation was measured during the testes and confronted with the measurements in the collector. With these measurements the global and optical efficiencies of the collector was determined. To determine the thermal efficiency and to obtain a global heat loss coefficient, thermal losses tests were carried out.
80

Eletrodos transparentes e flexíveis baseados em compósitos de grafeno oxidado : preparação, caracterização e aplicação em células solares orgânicas

Lima, Lucas Ferreira January 2016 (has links)
Orientadora: Profa. Dra. Lucimara Stolz Roman / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências Exatas, Programa de Pós-Graduação em Física. Defesa: Curitiba, 26/02/2016 / Inclui referências : f. 95-102 / Resumo: Este trabalho apresenta a caracterização e aplicação de filmes finos, flexíveis, transparentes e condutores elétricos baseados em compósitos entre grafeno oxidado (GO) e o polímero condutor o poli(3,4-etilenodioxitiofeno):poli(estireno sulfonato) (PEDOT:PSS). A dispersão em água do óxido de grafeno utilizada nesse trabalho foi obtida pelo emprego da oxidação química da grafite natural cristalina. Os compósitos GO:PEDOT:PSS foram obtidos através da mistura em meio aquoso de diferentes proporções desses materiais. Os filmes foram depositados diretamente em substratos de politereftalato de etileno (PET) e secos em atmosfera ambiente. A caracterização óptica foi realizada através da técnica de espectrofotometria. O desempenho elétrico foi determinado pelo uso da técnica de medida da resistência de folha a 4 pontas. Foram encontrados valores de transmitância óptica e resistividade elétrica que tornam esses compósitos atrativos para aplicações em dispositivos optoeletrônicos. Além disso, submetendo o conjunto substrato/compósito a ensaios de torção, os materiais exibiram uma excelente estabilidade mecânica de suas propriedades elétricas, mantendo a mesma resistência de folha mesmo após 1000 ciclos de torção de 45º. O estudo da proporção de mistura entre GO e PEDOT mostrou que existe um valor de razão GO/PEDOT ótimo do ponto de vista das propriedades elétricas. Essa característica indica um efeito sinérgico entre os componentes. A análise morfológica, realizada por meio da comparação das micrografias obtidas através do uso da técnica de microscopia de força atômica (AFM), endossa esses argumentos. Os filmes foram aplicados como eletrodos transparentes em células solares orgânicas em estrutura de bicamada. São apresentados estudos detalhado do efeito da concentração de PEDOT:PSS na mistura, da diluição do PEDOT, efeito da temperatura de tratamento térmico e da espessura dos filmes. Essas variáveis impactam diretamente na transmitância e resistividade dos compósitos. Consequentemente, o desempenho das células solares baseadas nesses compósitos é diretamente afetado. O dispositivo no qual é empregado o filme do compósito cuja razão GO/PEDOT é ótima obteve uma eficiência de conversão de potência 1,10%, valor duas vezes maior que aquele baseado somente em PEDOT:PSS. Palavras-chave: Óxido de Grafeno, PEDOT:PSS, Células Solares Orgânicas, Eletrodos Transparentes, Eletrônica Flexível. / Abstract: In this work we present the graphene oxide (GO) and conductive polymer poly(3,4–ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) based composite characterization and application as a flexible, transparent and electrical conductive thin films. The graphene oxide water dispersion used in this work was obtained through a crystalline natural graphite chemical oxidation route. The composite GO:PEDOT:PSS were obtained by mixing different proportions of these materials in aqueous media. The films were drop casted onto polyethylene terephthalate (PET) substrates in environmental atmosphere. The optical characterization was performed by spectrophotometric technique. The electrical performance was determined by using the 4–probe technique. It was found an optical transmittance and an electrical resistivity that make this composite attractive for optoelectronic devices application. Furthermore, the substrate/composite bend essays showed that the composite electrical properties presents an excellent mechanical stability, keeping the same sheet resistance figures even after 1000 cycles of 45° twist. The study of the mixing ratio of GO and PEDOT have shown that there is an optimal value of GO/PEDOT ratio from the electrical properties point of view. This characteristic indicates a synergetic effect between the compounds. The morphological analyses performed by comparing the micrographs obtained by atomic force microscopy (AFM) endorse this argument. The films were applied as transparent electrodes in bilayer structured organic solar cells. It is presented a detailed study of PEDOT:PSS concentration effect in the blend, the PEDOT:PSS solution dilution, the annealing temperature effect and the films thick. These variables directly impact in the composite film transmittance, resistivity and hence the devices performance. The cell–based composite film which optimal GO/PEDOT ratio could reach a power conversion efficiency around 1.10%, which is twice higher than the PEDOT:PSS based one. Key–words: Graphene oxide, PEDOT:PSS, Organic Solar Cells, Transparent Electrodes, Flexible Electronics.

Page generated in 0.0645 seconds