Energibesparing för uppvärmning av vatten i simhall : Exempel från Sunnerbohallen i Ljungby / Energy savings for the heating of water in swimming pools : Example from Sunnerbohallen in Ljungby

Trubarac, Miki, Trubarac, Nikola January 2014 (has links)
Den genomsnittliga energianvändningen för badhus på 403 kWh/m2 vilket gör denna lokaltyp till den mest energikrävande i Sverige. Detta examensarbete visar att användning av värmeväxlare generar stora energibesparingar vilket minskar den totala kostnaden för vattenuppvärmning i badanläggningar. Genom att samutnyttja olika anläggningars resurser (t.ex kylanläggningar för ishallar) kan värmetillförseln för vattenuppvärmning nästintill vara gratis.
2

Rening av rökgaskondensat i ett fjärrvärmeverk : Återanvändning av rökgaskondensat som spädvatten / Purification of flue gas condensate in heat plants : Reuse of flue gas condensate as feed water

Dabrowski, Patrik January 2017 (has links)
Arvika Fjärrvärme AB is manufacturing and distributing district heating to around 300 customers in Arvika. Heat production consists of a BFB boiler fed with GROT fuel (branches and peaks) and delivers a maximum power of 30 MW. In order to operate the plant, an average of 60 m3 of water per day is consumed from the urban water network. The water consumption is divided between water treatment, sooting and process cooling. In the processes, sulfur is dosed to obtain a more complete combustion of the hazardous flue gases that can occur. This is a result of previous thesis made for Arvika fjärrvärme. GROT is a fuel that contains high levels of moisture, which means that a high amount of condensate is formed during combustion, averaging 100 m3 per day. At present, condensate is sufficient to meet the condensate limit values ​​to be flushed into the drain. This is achieved by sand filtration and pH neutralization. Today, Arvika heat production is equipped with a purification stage for the feed water consisting of a softening filter and membrane filtration. This creates good conditions for cleaning the condensate and recirculating it in the process. Questions for this study are which hazardous substances the condensate can contain and how the condensate composition affected due to sulfur dosage. In addition, Arvika fjärrvärme wants to find out whether the purified condensate can replace the use of the urban water and, finally, if the condensate can be purified and used as feed water in the process. The execution of the work was based on a full-scale attempt in two operating cases of 9 and 18 MW. The tank collecting all condensate after purification in the sand filter and pH neutralization was coupled to the feed water purification stage. Thus, the condensate was pumped and purified in the softening filter and membrane filter. Assay substrates were collected before and after purification of the condensate. In addition to the topics that Arvika investigates, high levels of alkalinity were found in the condensate. The sulfur dosage that Arvika technology works with can be the cause of the high concentrations of sulphate. However, it appears that both the sulfate and alkalinity were purified in the membrane filter. The amount of condensate formed cannot completely replace the entire water requirement, but definitely large parts. The condensate can be used as feed water based on the retention rate for all substances. However, it appears that two substances, chloride and sulphate can create problems for the membrane filter. To investigate this, the condensate should be tested over a longer period of time to see the affect the chloride as well as the sulphate in the long run. / Arvika Fjärrvärme AB bedriver produktion och distribution av fjärrvärme till ca 300 kunder runt om i Arvika. Värmeproduktionen består av en BFB-panna som matas med bränslet GROT (grenar och toppar) och levererar en maxeffekt på 30 MW. För att driva anläggningen förbrukas i snitt 60 m3 vatten per dag från stadsvattennätet för spädvattenförberedning, sotning och processkylning. I denna typ av värmeproduktion som Arvika Fjärrvärme bedriver doseras svavel. Detta är ett resultat av ett tidigare examensarbete som visade att vid en dosering av svavel bildas det färre farliga rökgaser som kan uppstå vid förbränningen. GROT är ett bränsle som innehåller höga halter fukt vilket innebär att höga mängder kondensat bildas vid förbränningen, i snitt 100 m3 per dag. I dagsläget renas kondensatet tillräckligt för att möta de gränsvärden för att kondensatet ska få spolas ner i avloppet. Detta uppnås genom en sandfiltrering och pH-neutralisering. Idag är Arvika Fjärrvärme utrustade med ett reningssteg för spädvattnet bestående av ett avhärdningsfilter samt membranfilter. Detta skapar goda förutsättningar för att rena kondensatet och återcirkulera det i processen. Funderingar som uppstår är vilka farliga ämnen som kondensatet kan innehålla samt hur kondensatsammansättningen påverkas av svaveldoseringen. Dessutom ställer sig värmeverket frågan om det renade kondensatet kan ersätta förbrukningen av stadsvattnet och slutligen om kondensatet kan renas och användas som spädvatten i processen. Genomförandet av arbetet baserades på ett fullskaligt försök under två driftfall på 9 samt 18 MW. Tanken som samlar upp allt kondensat efter rening i sandfiltret och pH neutraliseringen kopplades på i steget för spädvattenrening. På så sätt pumpades kondensatet igenom och renades i avhärdningsfiltret samt membranfiltret. Analysunderlag samlades in före samt efter rening av kondensatet. Förutom de ämnen som Arvika fjärrvärme undersöker förkommer höga halter alkalinitet i kondensatet som bidrar till bildning av pannsten. Svaveldoseringen som Arvika fjärrvärme jobbar med kan vara orsaken till de höga koncentrationerna av sulfat. Det visar sig dock att både sulfatet och alkaliniteten renas bort i membranfiltret. Mängden kondensat som bildas kan inte helt ersätta hela vattenbehovet men definitivt stora delar. Kondensatet kan användas som spädvatten om retentionsgraden för ämnena anses hög nog. Det visar sig dock att två ämnen, klorid och sulfat, kan skapa problem för membranfiltret. För att undersöka detta bör kondensatet testas under en längre tidsperiod för att se vilken påverkan klorid och sulfat har i längden.