• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 47
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 56
  • 56
  • 43
  • 40
  • 28
  • 25
  • 23
  • 23
  • 22
  • 20
  • 13
  • 13
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A comparison of boiler laws with suggestions for a uniform law

Mainland, John. January 1914 (has links)
Thesis (M.E.)--University of Wisconsin--Madison, 1914. / Typescript. Includes index. eContent provider-neutral record in process. Description based on print version record.
2

Suppression of vapor explosions during rapid quenching of char beds in chemical recovery boilers

Delaney, James Carroll 05 1900 (has links)
No description available.
3

Přepočet kotle při změně jmenovitých parametrů / Recalculation boiler at change of nominal parametrs

Haška, Miroslav January 2009 (has links)
This thesis concerns with recalculation of steam boiler. Arrangement for reaching of new steam boiler parameters and temperature of combustion gases was suggested at first. Then it was verified with thermal calculation, all necessities included.
4

Plynofikace uhelného kotle 210 t/h; 13,63 MPa; 540 °C / Gasification of coal boiler 210 t/h; 13,63 MPa; 540 °C

Zajíc, Josef January 2013 (has links)
This thesis aims to gas installation of the coal boiler and its thermal recount. In the first part, there is implemented calculation of the combusting chamber. After that follows the recalculation of heat exchange surfaces and proposal tube air heater, which will replace the existing air heater Ljungström. The emphasis is placed on the preservation of the exsiting steam parametrs and keeps emission limit of NOx.
5

Conversion of Furnace oil fired boiler to biomass (Gliricidia) fired (External/Internal) furnace boiler

Channa Gaya Siriwardhana, Kahandawa Arachchilage January 2010 (has links)
In the present era, with the prevailing competition, the cost of production plays a vital role. As the price of petroleum oils, especially diesel and furnace oil are growing at a steeper rate than solid fuel price, finding a substitute for furnace oil is one of the alternative available. Furnace oil used in boilers can be totally substitute by biomass with an equivalent ratio of 3.5:1 kg/liter on the basis of calorific value. This may results in saving of more than 60% of operating cost and would have attractive payback period of 6-8 months. Sri Lanka has large agriculture base and very common of having Gliricidia as an under-grow. The other biomass fuels such as paddy husk, saw dust, firewood are also available in large quantities around the country. Objective of this article is to study the conversion of presently  running furnace oil fired boiler, which is located at Ambilipitiya paper factory,Sri Lanka to biomass fired external furnace boiler namely water-wall boiler, techno economical study of the project and commissioning. Further a case study, which was done previous to this study and running successfully, is described to show the viability of the conversion using the internal furnace method. This case study was done at a Textile factory namely Brandix Finishing, Siduwa, and Sri Lanka. The results will be reducing the operating cost of the boilers and reduction of green house gas emission.  Opportunities for rural people to get extra income by farming Gliricidia, extra income from saw dust, paddy husk, and firewood are indirect benefits of the project. This report gives details of technical, environmental and commercial aspects of this unique opportunity.      Supervised by: Dr.Primal Fernando, Senior Lecturer, University of Peradeniya
6

Emprego da energia solar para pré-aquecimento de água de reposição de caldeira. / Use of solar energy for boiler feed water preheating.

Fabrício dos Santos Dantas 15 August 2013 (has links)
Apresenta-se uma avaliação técnico-econômica para o préaquecimento solar da água de reposição em caldeiras de sistemas de vapor abertos. São empregados, para compor um estudo de caso, os dados de uma indústria de laticínios de médio porte situada próximo da cidade do Rio de Janeiro. Quarenta e oito simulações computacionais do sistema de aquecimento solar (SAS) foram realizadas em TRNSYS, correspondendo aos 5% melhores resultados econômicos de uma série de 2.700 simulações mais simples (método φ-f-chart), programados em MATLAB. Foram empregados dados horários de ano típico meteorológico (TMY) para a cidade do Rio de Janeiro. O ganho econômico foi baseado no consumo evitado dos três combustíveis mais comuns na indústria de laticínios, enquanto o custo de investimento foi composto a partir de valores comerciais e da literatura. Os resultados da avaliação econômica mostraram-se desfavoráveis para a substituição de óleo combustível, favoráveis no caso de caldeiras a gás natural, condicionado a existência de subsídios, e bem competitivos para a substituição de GLP. A eficiência térmica do sistema mostrou ser o parâmetro técnico chave para o desempenho econômico, consequentemente, uma vez que a eficiência se mostrou inversamente proporcional tanto ao volume do reservatório quanto à área de coletores, não há uma configuração ótima para o sistema. Não obstante, os resultados permitiram a proposição de políticas públicas para incentivar o uso da energia solar na indústria leiteira e, consequentemente, contribuir para a preservação ambiental. / It is presented a technical and economical feasibility assessment of solar preheating of steam boiler feed water for opened vapor systems. Data from a medium sized dairy industry near Rio de Janeiro city, in Brazil, is used to compose a case study. Forty eight solar heating system (SAS) computer simulations were carried out in TRNSYS, for a range of design parameters corresponding to the 5% best economical results of a series of 2700 simpler simulations (φ,f-chart method), programmed on MATLAB. Rio de Janeiro typical meteorological year (TMY) hourly weather data was used. Revenue was based on the avoided consumption of the three most used fuels on dairy industries, while investment cost was composed from both commercial and literature values. Economical assessment results showed unfavorable for the displacement of fuel oil, favorable for substituting natural gas, provided subsidizing, and well competitive against LPG. Systems thermal efficiency showed to be the key technical factor for economical performance, thus, as efficiency was found to be inversely proportional for both storage volume and collector area, there isnt an optimal system configuration. The results, though, made it possible to address environmentally sound public policies to encourage solar energy use on dairy industries.
7

Řízení systému parního čištění kotle

Příkazský, Petr January 2015 (has links)
Diploma thesis focuses on the topic of cleaning boilers in heating and power generation industry and automation of boiler cleaning process. There are summarized facts about cleaning devices, from which these systems consist of and as well as about support and control devices. Based on this facts, is developed control system and visualization interfaces with an emphasis on functionality into the system.
8

Emprego da energia solar para pré-aquecimento de água de reposição de caldeira. / Use of solar energy for boiler feed water preheating.

Fabrício dos Santos Dantas 15 August 2013 (has links)
Apresenta-se uma avaliação técnico-econômica para o préaquecimento solar da água de reposição em caldeiras de sistemas de vapor abertos. São empregados, para compor um estudo de caso, os dados de uma indústria de laticínios de médio porte situada próximo da cidade do Rio de Janeiro. Quarenta e oito simulações computacionais do sistema de aquecimento solar (SAS) foram realizadas em TRNSYS, correspondendo aos 5% melhores resultados econômicos de uma série de 2.700 simulações mais simples (método φ-f-chart), programados em MATLAB. Foram empregados dados horários de ano típico meteorológico (TMY) para a cidade do Rio de Janeiro. O ganho econômico foi baseado no consumo evitado dos três combustíveis mais comuns na indústria de laticínios, enquanto o custo de investimento foi composto a partir de valores comerciais e da literatura. Os resultados da avaliação econômica mostraram-se desfavoráveis para a substituição de óleo combustível, favoráveis no caso de caldeiras a gás natural, condicionado a existência de subsídios, e bem competitivos para a substituição de GLP. A eficiência térmica do sistema mostrou ser o parâmetro técnico chave para o desempenho econômico, consequentemente, uma vez que a eficiência se mostrou inversamente proporcional tanto ao volume do reservatório quanto à área de coletores, não há uma configuração ótima para o sistema. Não obstante, os resultados permitiram a proposição de políticas públicas para incentivar o uso da energia solar na indústria leiteira e, consequentemente, contribuir para a preservação ambiental. / It is presented a technical and economical feasibility assessment of solar preheating of steam boiler feed water for opened vapor systems. Data from a medium sized dairy industry near Rio de Janeiro city, in Brazil, is used to compose a case study. Forty eight solar heating system (SAS) computer simulations were carried out in TRNSYS, for a range of design parameters corresponding to the 5% best economical results of a series of 2700 simpler simulations (φ,f-chart method), programmed on MATLAB. Rio de Janeiro typical meteorological year (TMY) hourly weather data was used. Revenue was based on the avoided consumption of the three most used fuels on dairy industries, while investment cost was composed from both commercial and literature values. Economical assessment results showed unfavorable for the displacement of fuel oil, favorable for substituting natural gas, provided subsidizing, and well competitive against LPG. Systems thermal efficiency showed to be the key technical factor for economical performance, thus, as efficiency was found to be inversely proportional for both storage volume and collector area, there isnt an optimal system configuration. The results, though, made it possible to address environmentally sound public policies to encourage solar energy use on dairy industries.
9

Návrh parního plynového kotle / Gas steam boiler design

Vacek, Jiří January 2021 (has links)
The aim of this thesis is a draft of a gas steam boiler with steam output of 200 t/h. The first part of the paper provides stoichiometric calculations, then there are calculations of the dew point, boiler efficiency and the amount of gas. After that, calculations and a draft of the combustion chamber are carried out and then heat balances are drafted. In the following text, geometric properties of individual heat exchanging surfaces are drafted. At the end, there are control calculations. This thesis contains a blueprint of the gas steam boiler.
10

Kotel na spalování výpalků lihovarů / Steam boiler for fytomass

Baláš, Jiří January 2008 (has links)
The purpose of this Diploma Thesis was the construction design of the steam boiler for fytomass. For the specified parameters of biomass have been gradually implemented stoichiometric calculations of which are further based calculation of enthalpies of combustion gas. In the next part have been dealt with heat balance of the boiler, the efficiency of the boiler, recirculation of exhaust gases and the temperature of the combustion gases in outlet from fire. Thereinafter, the proposal of particular heat surfaces of steam boiler was solved, so that the resulting number and size correspond to the desired parameters. The parameters are temperature, pressure and the amount of steam.

Page generated in 0.0718 seconds