• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 9
  • 3
  • Tagged with
  • 23
  • 14
  • 14
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Automatisierte Optimierung von induktiven Bauelementen für Stromrichteranwendungen /

Wallmeier, Peter. January 2001 (has links)
Zugl.: Paderborn, Universiẗat, Diss., 2000.
2

Kompensation schnell veränderlicher Blindströme und Spannungsstabilisierung mit netzgeführtem Stromrichter

Lê, Thanh-Nam, January 1982 (has links)
Thesis (Doctoral)--Ruhr-Universität Bochum, 1982.
3

Untersuchungen zum Einsatz von unipolaren SiC Leistungshalbleiterbauelementen in Antriebsstromrichtern

Domes, Daniel January 2009 (has links)
Zugl.: Chemnitz, Techn. Univ., Diss., 2009
4

Spannungs- und Stromeffektivwerte und Spannungswelligkeiten voll- und halbgesteuerter Stromrichterschaltungen bei berücksichtigter Kommutierung

Sikkema, Ulrich. Unknown Date (has links)
Universiẗat, Diss., 1997--Dortmund. / Dateiformat: PDF.
5

Bewertung der Elektroenergiequalität in Netzen mit leistungsstarken Stromrichteranlagen unter Beachtung des Einflusses ihrer Regelung und Steuerung /

Prinz, Steffen. Stade, Dietrich January 2005 (has links)
Techn. Univ., Diss.--Ilmenau, 2005.
6

Nutzung von Momentanleistung und virtuellem Fluss für den netzfreundlichen und hochdynamischen Betrieb von Netzstromrichtern

Klahn, Michael January 2008 (has links)
Zugl.: Dresden, Techn. Univ., Diss., 2008
7

Models for transient simulations of decentral power generation implementation and verification in PowerFactory /

Braun, Martin. January 2005 (has links)
Stuttgart, Univ., Diplomarb., 2005.
8

Operation of Parallel Connected Converters as a Multilevel Converter

Kannan, Vijay 04 June 2018 (has links) (PDF)
The still increasing demand of electrical energy and the rising popularity of renewable energy sources in today's world are two important developments that necessitate the need for innovative solutions in the field of power electronics. Parallel operation of converters is one possible method in trying to bridge an increased current demand. The classical two-level converters, which are the standard in low voltage applications, are rarely adopted in medium and high voltage applications due to the voltage limits on power semiconductor devices. That is one reason for the growing popularity of multilevel converter topologies in medium and high-voltage applications. Although an increase in the number of voltage levels of a multilevel converter has its advantages, there are also challenges posed due to the increased number of switching devices. This has resulted in three-level converters being the most popular compared to converters of higher voltage levels. In this dissertation, the unified operation of parallel connected three-level converter units as a multilevel converter of higher voltage levels is proposed. The mathematical basis for operating parallel connected converter units as a single multilevel converter and the governing equations for such systems are derived. The analysis and the understanding of these equations are important for assessing practicality of the system and devising appropriate control structures. Parallel operation of converter units operating as multilevel converter have their own set of challenges, the two foremost being that of load-sharing and the possibility of circulating and cross currents. Developing solutions to address these challenges require a thorough understanding of how these manifest in the proposed system. Algorithms are then developed for tackling these issues. The control structures are designed and the developed algorithms are implemented. The operation of the system is verified experimentally. / Die weiterhin steigende Nachfrage nach elektrischer Energie und die zunehmende Verwendung erneuerbarer Energiequellen in der heutigen Welt sind zwei wichtige Entwicklungen, die die Notwendigkeit innovativer Lösungen im Bereich der Leistungselektronik erfordern. Der Parallelbetrieb von Stromrichtern ist eine mögliche Methode, um einen erhöhten Strombedarf zu decken. Der klassische Zweipunkt-Spanungszwischenkreisstromrichter, der bei Niederspannungsanwendungen weit verbreitet ist, wird aufgrund der Spannungsgrenzen für Leistungshalbleiterbauelemente zunehmend weniger in Mittel- und Hochspannungsanwendungen eingesetzt. Die begrenzte Spannungsbelastbarkeit der Leistungshalbleiterbauelemente ist ein Grund für die wachsende Beliebtheit von Mehrpunkt-Stromrichtertopologien in Mittelund Hochspannungsanwendungen. Obwohl eine Erhöhung der Anzahl der Spannungsstufen eines Mehrpunkt-Stromrichters Vorteile hat, gibt es auch Herausforderungen und Nachteile aufgrund der erhöhten Anzahl von Leistungshalbleitern. Dies hat dazu geführt, dass der Dreipunkt-Stromrichter die verbreiteste Topologie im Vergleich zu anderen Stromrichtern mit einer höheren Anzahl von Spannungsstufen ist. In dieser Dissertation wird der Betrieb von parallel geschalteten Dreipunkt-Stromrichtereinheiten als ein Mehrpunkt-Stromrichter mit erhöhter Anzahl an Spannungsstufen vorgeschlagen. Die mathematische Basis für den Betrieb von parallel geschalteten Stromrichtereinheiten als ein Mehrpunkt-Stromrichter und die beschreibenden Gleichungen eines solchen Systems werden abgeleitet. Die Analyse und das Verständnis dieser Gleichungen sind wichtig für die Beurteilung der Praktikabilität des Systems und die Erarbeitung geeigneter Regelstrukturen. Der parallele Betrieb von Stromrichtereinheiten hat seine eigenen Herausforderungen, wobei die beiden wichtigsten die Lastverteilung und die Möglichkeit von Kreis- und Querströmen sind. Die Entwicklung von Lösungen zur Bewältigung dieser Herausforderungen erfordert ein gründliches Verständnis dafür, wie sich diese Phänomene in dem vorgeschlagenen System manifestieren. Algorithmen zur Lösung dieser Probleme werden anschlieend entwickelt. Die Regelstrukturen werden entworfen und die entworfenen Algorithmen implementiert. Die Funktionsweise des Systems wird experimentell überprüft.
9

Investigation of Multi-Level Neutral Point Clamped Voltage Source Converters using Isolated Gate Bipolar Transistor Modules

Wilson Veas, Alan Hjalmar 29 April 2019 (has links)
Among the multilevel (ML)-voltage source converters (VSCs) for medium voltage (MV) and high power (HP) applications, the most used power topology is the three level (3L)-neutral point clamped (NPC)-VSC, due to its features such as common direct current (DC)-bus capability with medium point, absence of switches in series-connection, low part count, and straightforward control. The use of MV-insulated gate bipolar transistor (IGBT) modules as power switches offers further advantages like inexpensive gate drivers and survival capability after short-circuit. However, the IGBT modules have a reduced life cycle due to thermal stress generated by load cycles. Despite the advantages of the 3L-NPC-VSC, its main drawback is the uneven power loss distribution among its power devices. To address this issue and to improve other characteristics, more advanced ML converters have been developed. The 3L-active neutral point clamped (ANPC)-VSC allows an improved power loss distribution thanks to its additional IGBTs, which increase the number of feasible zero-states, but needs a loss balancing scheme to choose the proper redundant zero-state and a more complex commutation sequence between states. The 3L-neutral point piloted (NPP)-VSC improves the power loss distribution thanks to the use of series-connected switches between the output terminal and the positive and negative DC-link terminals. Other advanced power topologies with higher amount of levels include the 5L-ANPC-VSC, which has a flying capacitor per phase to generate the additional levels; and the 5L-stacked multicell converter (SMC), which needs two flying capacitors per phase. The goal of this work is to is to evaluate the performance of the aforementioned NPC-type ML converters with common DC-link, included the ones with flying capacitors, in terms of the power loss distribution and the junction temperature of the most stressed devices, which define, along with the nominal output voltage, the maximum power the converter can deliver. A second objective of this work is to describe the commutations of a MV 3L-ANPC-VSC phase leg prototype with IGBT modules, including all the intermediate switching states to generate the desired commutations.:Figures and Tables V Glossary XIII 1. Introduction 1 2. State of the art of medium voltage source converters and power semiconductors 5 2.1. Overview of medium voltage source converters 5 2.1.1. Multilevel Voltage Source Converter topologies 6 2.1.2. Application oriented basic characteristic of IGCTs and IGBTs 10 2.1.3. Market overview of ML-VSCs 11 2.2. IGBT modules for MV applications 12 2.2.1. Structure and Function 12 2.2.2. Electrical characteristics of the IGBT modules 15 2.2.3. Power losses and junction temperatures estimation 17 2.2.4. Packaging 19 2.2.5. Reliability and Life cycle of IGBT modules 21 2.2.6. Market Overview 23 2.3. Summary of Chapter 2 23 3. Structure, function and characteristics of NPC-based VSCs 25 3.1. The 3L-NPC-VSC 25 3.1.1. Power Topology 25 3.1.2. Switching states, current paths and blocking voltage distribution 26 3.1.3. Modulation of three-level inverters 28 3.1.4. Power loss distribution 32 3.1.5. “Short” and “long” commutation paths 33 3.2. The 3L-NPP-VSC 34 3.2.1. Power Topology 34 3.2.2. Switching states, current paths and blocking voltage distribution 35 3.2.3. Power Loss distribution 36 3.3. The 3L-ANPC-VSC 37 3.3.1. Power Topology 37 3.3.2. Switching states, current paths and blocking voltage distribution 38 3.3.3. Commutations and power loss distribution 39 3.3.4. Loss balancing schemes 57 3.4. The 5L-ANPC-VSC 60 3.4.1. Power Topology 60 3.4.2. Switching states, current paths and blocking voltage distribution 61 3.4.3. Commutation sequences 62 3.4.4. Power Loss distribution 70 3.4.5. Modulation and balancing strategies of capacitor voltages 70 3.5. The 5L-SMC 74 3.5.1. Power Topology 74 3.5.2. Switching states, current paths and blocking voltage distribution 75 3.5.3. Commutations and power loss distribution 78 3.5.4. Modulation and balancing strategies of capacitor voltages 80 3.6. Summary of Chapter 3 81 4. Comparative evaluation and performance of NPC-based converters 83 4.1. Motivation and goal of the comparisons 83 4.2. Basis of the comparison 83 4.2.1. Simulation scheme 85 4.2.2. Losses and thermal models for (4.5 kV, 1.2 kA) IGBT modules 86 4.2.3. Operating points, modulation, controllers and general parameters 88 4.2.4. Life cycle estimation 94 4.3. Simulation results of the 3.3 kV 3L-VSCs 97 4.3.1. Loss distribution and temperature at equal phase current 97 4.3.2. Maximum phase current 109 4.3.3. Life cycle 111 4.4. Simulation results of the 6.6 kV 5L and 3L-VSCs 115 4.4.1. Loss distribution and temperature at equal phase current 115 4.4.2. Maximum phase current 120 4.4.3. Life cycle 128 4.5. Summary of Chapter 4 132 5. Experimental investigation of the 3L-ANPC-VSC with IGBT modules 135 5.1. Goal of the work 135 5.2. Description of the 3L-ANPC-VSC test bench 136 5.2.1. Medium voltage stage 136 5.2.2. Gate drivers and digital signal handling 138 5.2.3. Measurement equipment 139 5.3. Double-pulse test and commutation sequences 140 5.3.1. Description of the double-pulse test for the 3L-ANPC-VSC 140 5.3.2. Commutation sequences for the double-pulse test 142 5.4. Commutation measurements 142 5.4.1. Switching and transition times 144 5.4.2. Type I commutations 145 5.4.3. Type I-U commutations 150 5.4.4. Type II commutations 150 5.4.5. Type III commutations 157 5.4.6. Comparison of the commutation times 157 5.4.7. Stray inductances of the “short” and “long” commutations 163 5.5. Summary of Chapter 5 167 6. Conclusions 169 Appendices 173 A. Thermal model of IGBT modules 175 A.1. General “Y” model 175 A.2. “Foster” thermal circuit 177 A.3. “Cauer” thermal circuit 178 A.4. From “Foster” to “Cauer” 179 A.5. Temperature comparison using “Foster” and “Cauer” networks 181 B. The “Rainflow” cycle counting algorithm 183 C. Description of the wind generator example 187 C.1. Simulation models 188 C.1.1. Wind turbine 188 C.1.2. Synchronous generator, grid and choke filter 189 C.1.3. Converters 189 C.2. Controllers 190 C.2.1. MPPT scheme 190 C.2.2. Pitch angle controller 191 C.2.3. Generator side VSC 192 C.2.4. Grid side VSC 193 D. 3D-surfaces of the maximum load currents in NPC-based converters 195 Bibliography 201 Bibliography 201 / Unter den Multilevel-Spannungsumrichtern für Mittelspannungs- und Hochleistungsanwendungen ist die am häufigsten verwendete Leistungstopologie der NPC-VSC, wegen seinen Merkmalen wie die Gleichstrom-Bus fähigkeit mit mittlerem Punkt, das Fehlen von Schaltern in Reihenschaltung, eine geringe Anzahl von Bauteilen und eine einfache Steuerung. Die Verwendung von Bipolartransistor Modulen mit isolierter Gate-Elektrode als Leistungsschalter bietet weitere Vorteile wie kostengünstige Gatetreiber und Überlebensfähigkeit nach einem Kurzschluss. Die IGBT-Module haben jedoch aufgrund der durch Lastzyklen erzeugten thermischen Belastung eine verkürzte Lebensdauer. Trotz der Vorteile des 3L-NPC-VSC ist der Hauptnachteil die ungleichmäßige Verteilung der Leistungsverluste zwischen den Leistungsgeräten. Um dieses Problem zu beheben und andere Eigenschaften zu verbessern, wurden fortgeschrittenere ML-Konverter entwickelt. Das 3L-ANPC-VSC ermöglicht dank seiner zusätzlichen IGBTs eine verbesserte Verlustleistungsverteilung, wodurch die Anzahl der möglichen Null-Zustände erhöht wird, es ist jedoch ein Verlustausgleichsschema erforderlich, um den richtigen redundanten Null-Zustand, und benötigt auszuwählende komplexere Kommutierungssequenz zwischen Zuständen. Das 3L-NPP-VSC verbessert die Verlustleistungsverteilung durch die Verwendung von in Reihe geschalteten Schaltern zwischen der Ausgangsklemme und den positiven und negativen Zwischenkreisklemmen. Andere fortgeschrittene Leistungstopologien mit einer höheren Anzahl von Stufen umfassen den 5L-ANPC-VSC, der pro Phase einen fliegenden Kondensator zur Erzeugung der zusätzlichen Stufen aufweist; und den 5L-SMC, der pro Phase zwei fliegende Kondensatoren benötigt. Das Ziel dieser Arbeit ist es, die Leistung der oben genannten NPC-VSC, einschließlich der mit fliegenden Kondensatoren, hinsichtlich der Verlustleistungsverteilung und der Sperrschichttemperatur der am stärksten beanspruchten Geräte zu bewerten. Diese definieren zusammen mit der Nennausgangsspannung die maximale Leistung, die der Umrichter liefern kann. Ein zweites Ziel dieser Arbeit ist die Beschreibung der Kommutierungen eines MV 3L-ANPC-VSC- Prototyps mit IGBT-Modulen einschließlich aller Zwischenschaltzustände, um die gewünschten Kommutierungen zu erzeugen.:Figures and Tables V Glossary XIII 1. Introduction 1 2. State of the art of medium voltage source converters and power semiconductors 5 2.1. Overview of medium voltage source converters 5 2.1.1. Multilevel Voltage Source Converter topologies 6 2.1.2. Application oriented basic characteristic of IGCTs and IGBTs 10 2.1.3. Market overview of ML-VSCs 11 2.2. IGBT modules for MV applications 12 2.2.1. Structure and Function 12 2.2.2. Electrical characteristics of the IGBT modules 15 2.2.3. Power losses and junction temperatures estimation 17 2.2.4. Packaging 19 2.2.5. Reliability and Life cycle of IGBT modules 21 2.2.6. Market Overview 23 2.3. Summary of Chapter 2 23 3. Structure, function and characteristics of NPC-based VSCs 25 3.1. The 3L-NPC-VSC 25 3.1.1. Power Topology 25 3.1.2. Switching states, current paths and blocking voltage distribution 26 3.1.3. Modulation of three-level inverters 28 3.1.4. Power loss distribution 32 3.1.5. “Short” and “long” commutation paths 33 3.2. The 3L-NPP-VSC 34 3.2.1. Power Topology 34 3.2.2. Switching states, current paths and blocking voltage distribution 35 3.2.3. Power Loss distribution 36 3.3. The 3L-ANPC-VSC 37 3.3.1. Power Topology 37 3.3.2. Switching states, current paths and blocking voltage distribution 38 3.3.3. Commutations and power loss distribution 39 3.3.4. Loss balancing schemes 57 3.4. The 5L-ANPC-VSC 60 3.4.1. Power Topology 60 3.4.2. Switching states, current paths and blocking voltage distribution 61 3.4.3. Commutation sequences 62 3.4.4. Power Loss distribution 70 3.4.5. Modulation and balancing strategies of capacitor voltages 70 3.5. The 5L-SMC 74 3.5.1. Power Topology 74 3.5.2. Switching states, current paths and blocking voltage distribution 75 3.5.3. Commutations and power loss distribution 78 3.5.4. Modulation and balancing strategies of capacitor voltages 80 3.6. Summary of Chapter 3 81 4. Comparative evaluation and performance of NPC-based converters 83 4.1. Motivation and goal of the comparisons 83 4.2. Basis of the comparison 83 4.2.1. Simulation scheme 85 4.2.2. Losses and thermal models for (4.5 kV, 1.2 kA) IGBT modules 86 4.2.3. Operating points, modulation, controllers and general parameters 88 4.2.4. Life cycle estimation 94 4.3. Simulation results of the 3.3 kV 3L-VSCs 97 4.3.1. Loss distribution and temperature at equal phase current 97 4.3.2. Maximum phase current 109 4.3.3. Life cycle 111 4.4. Simulation results of the 6.6 kV 5L and 3L-VSCs 115 4.4.1. Loss distribution and temperature at equal phase current 115 4.4.2. Maximum phase current 120 4.4.3. Life cycle 128 4.5. Summary of Chapter 4 132 5. Experimental investigation of the 3L-ANPC-VSC with IGBT modules 135 5.1. Goal of the work 135 5.2. Description of the 3L-ANPC-VSC test bench 136 5.2.1. Medium voltage stage 136 5.2.2. Gate drivers and digital signal handling 138 5.2.3. Measurement equipment 139 5.3. Double-pulse test and commutation sequences 140 5.3.1. Description of the double-pulse test for the 3L-ANPC-VSC 140 5.3.2. Commutation sequences for the double-pulse test 142 5.4. Commutation measurements 142 5.4.1. Switching and transition times 144 5.4.2. Type I commutations 145 5.4.3. Type I-U commutations 150 5.4.4. Type II commutations 150 5.4.5. Type III commutations 157 5.4.6. Comparison of the commutation times 157 5.4.7. Stray inductances of the “short” and “long” commutations 163 5.5. Summary of Chapter 5 167 6. Conclusions 169 Appendices 173 A. Thermal model of IGBT modules 175 A.1. General “Y” model 175 A.2. “Foster” thermal circuit 177 A.3. “Cauer” thermal circuit 178 A.4. From “Foster” to “Cauer” 179 A.5. Temperature comparison using “Foster” and “Cauer” networks 181 B. The “Rainflow” cycle counting algorithm 183 C. Description of the wind generator example 187 C.1. Simulation models 188 C.1.1. Wind turbine 188 C.1.2. Synchronous generator, grid and choke filter 189 C.1.3. Converters 189 C.2. Controllers 190 C.2.1. MPPT scheme 190 C.2.2. Pitch angle controller 191 C.2.3. Generator side VSC 192 C.2.4. Grid side VSC 193 D. 3D-surfaces of the maximum load currents in NPC-based converters 195 Bibliography 201 Bibliography 201
10

Grid friendly digital control of active front-end converters minimizing of power interferences

Luu, Hong Viet January 2006 (has links)
Zugl.: Dresden, Techn. Univ., Diss., 2006

Page generated in 0.0749 seconds