The optimization of combined power-power generation cycles

Al-Anfaji, Ahmed Suaal Bashar January 2015 (has links)
An investigation into the performance of several combined gas-steam power generating plants’ cycles was undertaken at the School of Engineering and Technology at the University of Hertfordshire and it is predominantly analytical in nature. The investigation covered in principle the aspect of the fundamentals and the performance parameters of the following cycles: gas turbine, steam turbine, ammonia-water, partial oxidation and the absorption chiller. Complete thermal analysis of the individual cycles was undertaken initially. Subsequently, these were linked to generate a comprehensive computer model which was employed to predict the performance and characteristics of the optimized combination. The developed model was run using various input parameters to test the performance of the cycle’s combination with respect to the combined cycle’s efficiency, power output, specific fuel consumption and the temperature of the stack gases. In addition, the impact of the optimized cycles on the generation of CO2 and NOX was also investigated. This research goes over the thermal power stations of which most of the world electrical energy is currently generated by. Through which, to meet the increase in the electricity consumption and the environmental pollution associated with its production as well as the limitation of the natural hydrocarbon resources necessitated. By making use of the progressive increase of high temperature gases in recent decades, the advent of high temperature material and the use of large compression ratios and generating electricity from high temperature of gas turbine discharge, which is otherwise lost to the environment, a better electrical power is generated by such plant, which depends on a variety of influencing factors. This thesis deals with an investigation undertaken to optimize the performance of the combined Brayton-Rankine power cycles' performance. This work includes a comprehensive review of the previous work reported in the literature on the combined cycles is presented. An evaluation of the performance of combined cycle power plant and its enhancements is detailed to provide: A full understanding of the operational behaviour of the combined power plants, and demonstration of the relevance between power generations and environmental impact. A basic analytical model was constructed for the combined gas (Brayton) and the steam (Rankine) and used in a parametric study to reveal the optimization parameters, and its results were discussed. The role of the parameters of each cycle on the overall performance of the combined power cycle is revealed by assessing the effect of the operating parameters in each individual cycle on the performance of the CCPP. P impacts on the environment were assessed through changes in the fuel consumption and the temperature of stack gases. A comprehensive and detailed analytical model was created for the operation of hypothetical combined cycle power and power plant. Details of the operation of each component in the cycle was modelled and integrated in the overall all combined cycle/plant operation. The cycle/plant simulation and matching as well as the modelling results and their analysis were presented. Two advanced configurations of gas turbine cycle for the combined cycle power plants are selected, investigated, modelled and optimized as a part of combined cycle power plant. Both configurations work on fuel rich combustion, therefore, the combustor model for rich fuel atmosphere was established. Additionally, models were created for the other components of the turbine which work on the same gases. Another model was created for the components of two configurations of ammonia water mixture (kalina) cycle. As integrated to the combined cycle power plant, the optimization strategy considered for these configurations is for them to be powered by the exhaust gases from either the gas turbine or the gases leaving the Rankine boiler (HRSG). This included ChGT regarding its performance and its environmental characteristics. The previously considered combined configuration is integrated by as single and double effect configurations of an ammonia water absorption cooling system (AWACS) for compressor inlet air cooling. Both were investigated and designed for optimizing the triple combination power cycle described above. During this research, tens of functions were constructed using VBA to look up tables linked to either estimating fluids' thermodynamic properties, or to determine a number of parameters regarding the performance of several components. New and very interesting results were obtained, which show the impact of the input parameters of the individual cycles on the performance parameters of a certain combined plant’s cycle. The optimized parameters are of a great practical influence on the application and running condition of the real combined plants. Such influence manifested itself in higher rate of heat recovery, higher combined plant thermal efficiency from those of the individual plants, less harmful emission, better fuel economy and higher power output. Lastly, it could be claimed that various concluding remarks drawn from the current study could help to improve the understanding of the behaviour of the combined cycle and help power plant designers to reduce the time, effort and cost of prototyping.
2

Thermal energy storage in metallic phase change materials

Kotze, Johannes Paulus 12 1900 (has links)
Thesis (PhD) -- Stellenbosch University, 2014. / ENGLISH ABSTRACT: Currently the reduction of the levelised cost of electricity (LCOE) is the main goal of concentrating solar power (CSP) research. Central to a cost reduction strategy proposed by the American Department of Energy is the use of advanced power cycles like supercritical steam Rankine cycles to increase the efficiency of the CSP plant. A supercritical steam cycle requires source temperatures in excess of 620°C, which is above the maximum storage temperature of the current two-tank molten nitrate salt storage, which stores thermal energy at 565°C. Metallic phase change materials (PCM) can store thermal energy at higher temperatures, and do not have the drawbacks of salt based PCMs. A thermal energy storage (TES) concept is developed that uses both metallic PCMs and liquid metal heat transfer fluids (HTF). The concept was proposed in two iterations, one where steam is generated directly from the PCM – direct steam generation (DSG), and another where a separate liquid metal/water heat exchanger is used – indirect steam generation, (ISG). Eutectic aluminium-silicon alloy (AlSi12) was selected as the ideal metallic PCM for research, and eutectic sodium-potassium alloy (NaK) as the most suitable heat transfer fluid. Thermal energy storage in PCMs results in moving boundary heat transfer problems, which has design implications. The heat transfer analysis of the heat transfer surfaces is significantly simplified if quasi-steady state heat transfer analysis can be assumed, and this is true if the Stefan condition is met. To validate the simplifying assumptions and to prove the concept, a prototype heat storage unit was built. During testing, it was shown that the simplifying assumptions are valid, and that the prototype worked, validating the concept. Unfortunately unexpected corrosion issues limited the experimental work, but highlighted an important aspect of metallic PCM TES. Liquid aluminium based alloys are highly corrosive to most materials and this is a topic for future investigation. To demonstrate the practicality of the concept and to come to terms with the control strategy of both proposed concepts, a storage unit was designed for a 100 MW power plant with 15 hours of thermal storage. Only AlSi12 was used in the design, limiting the power cycle to a subcritical power block. This demonstrated some practicalities about the concept and shed some light on control issues regarding the DSG concept. A techno-economic evaluation of metallic PCM storage concluded that metallic PCMs can be used in conjunction with liquid metal heat transfer fluids to achieve high temperature storage and it should be economically viable if the corrosion issues of aluminium alloys can be resolved. The use of advanced power cycles, metallic PCM storage and liquid metal heat transfer is only merited if significant reduction in LCOE in the whole plant is achieved and only forms part of the solution. Cascading of multiple PCMs across a range of temperatures is required to minimize entropy generation. Two-tank molten salt storage can also be used in conjunction with cascaded metallic PCM storage to minimize cost, but this also needs further investigation. / AFRIKAANSE OPSOMMING: Tans is die minimering van die gemiddelde leeftydkoste van elektrisiteit (GLVE) die hoofdoel van gekonsentreerde son-energie navorsing. In die kosteverminderingsplan wat voorgestel is deur die Amerikaanse Departement van Energie, word die gebruik van gevorderde kragsiklusse aanbeveel. 'n Superkritiese stoom-siklus vereis bron temperature hoër as 620 °C, wat bo die 565 °C maksimum stoor temperatuur van die huidige twee-tenk gesmelte nitraatsout termiese energiestoor (TES) is. Metaal fase veranderingsmateriale (FVMe) kan termiese energie stoor by hoër temperature, en het nie die nadele van soutgebaseerde FVMe nie. ʼn TES konsep word ontwikkel wat gebruik maak van metaal FVM en vloeibare metaal warmteoordrag vloeistof. Die konsep is voorgestel in twee iterasies; een waar stoom direk gegenereer word uit die FVM (direkte stoomopwekking (DSO)), en 'n ander waar 'n afsonderlike vloeibare metaal/water warmteruiler gebruik word (indirekte stoomopwekking (ISO)). Eutektiese aluminium-silikon allooi (AlSi12) is gekies as die mees geskikte metaal FVM vir navorsingsdoeleindes, en eutektiese natrium – kalium allooi (NaK) as die mees geskikte warmteoordrag vloeistof. Termiese energie stoor in FVMe lei tot bewegende grens warmteoordrag berekeninge, wat ontwerps-implikasies het. Die warmteoordrag ontleding van die warmteruilers word aansienlik vereenvoudig indien kwasi-bestendige toestand warmteoordrag ontledings gebruik kan word en dit is geldig indien daar aan die Stefan toestand voldoen word. Om vereenvoudigende aannames te bevestig en om die konsep te bewys is 'n prototipe warmte stoor eenheid gebou. Gedurende toetse is daar bewys dat die vereenvoudigende aannames geldig is, dat die prototipe werk en dien as ʼn bevestiging van die konsep. Ongelukkig het onverwagte korrosie die eksperimentele werk kortgeknip, maar dit het klem op 'n belangrike aspek van metaal FVM TES geplaas. Vloeibare aluminium allooie is hoogs korrosief en dit is 'n onderwerp vir toekomstige navorsing. Om die praktiese uitvoerbaarheid van die konsep te demonstreer en om die beheerstrategie van beide voorgestelde konsepte te bevestig is 'n stoor-eenheid ontwerp vir 'n 100 MW kragstasie met 15 uur van 'n TES. Slegs AlSi12 is gebruik in die ontwerp, wat die kragsiklus beperk het tot 'n subkritiese stoomsiklus. Dit het praktiese aspekte van die konsep onderteken, en beheerkwessies rakende die DSO konsep in die kollig geplaas. In 'n tegno-ekonomiese analise van metaal FVM TES word die gevolgtrekking gemaak dat metaal FVMe gebruik kan word in samewerking met 'n vloeibare metaal warmteoordrag vloeistof om hoë temperatuur stoor moontlik te maak en dat dit ekonomies lewensvatbaar is indien die korrosie kwessies van aluminium allooi opgelos kan word. Die gebruik van gevorderde kragsiklusse, metaal FVM stoor en vloeibare metaal warmteoordrag word net geregverdig indien beduidende vermindering in GLVE van die hele kragsentrale bereik is, en dit vorm slegs 'n deel van die oplossing. ʼn Kaskade van verskeie FVMe oor 'n reeks van temperature word vereis om entropie generasie te minimeer. Twee-tenk gesmelte soutstoor kan ook gebruik word in samewerking met kaskade metaal FVM stoor om koste te verminder, maar dit moet ook verder ondersoek word.
3

The Composition and Distribution of Coal-Ash Deposits Under Reducing and Oxidizing Conditions From a Suite of Eight Coals

Brunner, David R. 09 April 2011 (has links) (PDF)
Eighteen elements, including: carbon, oxygen, sodium, magnesium, aluminum, silicon, phosphorus, sulfur, chlorine, potassium, calcium, titanium, chromium, manganese, iron, nickel, strontium, and barium were measured using a scanning electron microscope with energy dispersive spectroscopy from deposits. The deposits were collected by burning eight different coals in a 160 kWth, staged, down-fired, swirl-stabilized combustor. Both up-stream and down-stream deposits from an oxidizing region (equivalence ratio 0.86) and reducing region (equivalence ratio 1.15) were collected. Within the deposits, the particle size and morphology were studied. The average particle cross-sectional area from the up-stream deposits ranged from 10 - 75 µm2 and had a standard deviation of 36 - 340 µm2. These up-stream particles were of various shapes: spherical, previously molten particles; irregular particle that had not melted, hollowed spherical shells; and layered or strands of particles. These particles were a mixture of burned and unburned coal being deposited at various stages of burnout and having completed some burnout after deposition. The average particle cross-sectional area from the down-stream deposits ranged 0.9 - 7 µm2 and the standard deviation range of 2.6 - 30 µm2. The shape of the particles on the bottom sleeves are typically spherical indicating melting prior to deposition. Particles contained a distribution of elemental compositions that were not tightly grouped on ternary phase diagrams. This indicated that particles were not single compounds or phases but each particle contained a mixture of multiple compounds. Coals' deposit sulfur was strongly correlated with the calcium and iron content of the ASTM ash analysis. The low rank sub-bituminous and lignite coals that had high calcium content produced high sulfur deposits, particularly in the oxidizing region, down-stream deposits. The high iron bituminous coals, also produced high sulfur deposits, but more so in the reducing region, up-stream deposits. The low calcium and low iron coals produced low sulfur deposits. Mahoning was an exception being high in iron content but remaining low in sulfur content in the deposit. Gatling coal showed numerous deposit particles that contained only iron and sulfur consistent with the high pyrite content of Gatling coal. The average concentration of chlorine was insignificant in all of the deposits with the concentration being less than 100 ppm. Individual particles containing chlorine were found and were associated with potassium, sodium, and iron.