• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2274
  • 338
  • 70
  • 63
  • 59
  • 59
  • 58
  • 39
  • 20
  • 17
  • 16
  • 16
  • 16
  • 5
  • 3
  • Tagged with
  • 2742
  • 1066
  • 476
  • 459
  • 365
  • 285
  • 235
  • 208
  • 195
  • 191
  • 165
  • 164
  • 164
  • 160
  • 159
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
891

Quantificação da resoluçao do sistema SPECT-CZT através do uso da função de transferência modulada (MTF) /

Zandona, Ednaldo Alexandre. January 2013 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: José Roberto Saglieti / Banca: Eder Rezende Moraes / Resumo: A medicina nuclear é uma especialidade médica que se ocupa de técnicas de imagem para observar o estado fisiológico dos tecidos ou órgãos de forma não invasiva, através da marcação de moléculas participantes desses processos, com isótopos radioativos, originando assim os chamados radionuclídeos. O SPECT é um equipamento que se utiliza de imagens planares, obtidas de vários ângulos ao redor do objeto de interesse, e, através de algoritmos computacionais, obtêm uma imagem tomográfica dessas projeções. Sua origem remete há aproximadamente cinquenta anos atrás, com criação da Câmara Anger (Hall Anger, 1964). Durante todo esse tempo, embora tenha havido alguma evolução, a estrutura dessas gama câmaras praticamente ficou Inalterada. Os constantes avanços em pesquisas empregando cristais semicondutores nos exames cintilográficos, bem como a necessidade do surgimento de novos sistemas detectores, compactos, com maior poder de resolução e alta sensibilidade conjugados a crescente preocupação mundial com a minimização das doses de radiação ionizante utilizadas nos exames diagnósticos e terapias, impulsionou o desenvolvimento de novos sistemas detectores. Recentemente, duas Grandes Empresas lançaram comercialmente novos sistemas de detecção para aquisições tomográficas em medicina nuclear, utilizando detectores do estado sólido, mais especificamente cristais de telureto de cádmio e zinco (CZT). Algumas vantagens desse tipo de detector são a melhora sensível da relação sinal/ruído, o aumento da resolução espectral e espacial, o que em suma, resultam numa maior nitidez das imagens obtidas. O emprego desses detectores abre novas perspectivas para os protocolos de imagem. Entretanto, devido a inúmeros fatores, os equipamentos ditos CZT estão focados na área cardiológica, e devido a características próprias requerem a reformulação dos protocolos de aquisição de imagem além daqueles destinados ao ... / Abstract: Nuclear medicine is a medical specialty that deals with imaging techniques to observe the physiological status of the tissues or organs noninvasively, by dialing molecules participating in this process, with radioactive isotopes, thus giving the so-called radionuclides. The SPECT is a device that uses planar images, taken from different angles around the object of interest, and, through computer algorithms, obtains a tomographic image of those projections. Its origin refers for nearly fifty years ago, with the creation of the Chamber Anger (Anger Hall, 1964). Throughout this time, although there has been some evolution, the structure of these gamma cameras was virtually unchanged. The constant advances in research employing semiconductor crystals in scintigraphic examinations, as well as the need for the creation of new detectors systems, compacts, higher resolution and high sensitivity; combined with growing worldwide concern with minimization of doses of ionizing radiation used in diagnostic tests and therapies, spurred the development of new detector systems. Recently, two large companies launched commercially new detection systems for nuclear medicine tomographic acquisitions, using solid-state detectors, specifically crystals of zinc and cadmium telluride (CZT). Some advantages of this type of detector are sensitive improvement of signal / noise ratio, increased spectral and spatial resolution, which in short, resulting in greater clarity of the images obtained. The use of these detectors opens news perspectives for imaging protocols. However, due to numerous factors, equipment said CZT are focused on cardiology area, and due to the inherent characteristics, require reformulation of image acquisition protocols beyond those intended for Quality Control / Mestre
892

Influência do modelo experimental e do substrato nas alterações do esmalte clareado /

Silva, Úrsula Aparecida Escalero. January 2017 (has links)
Orientador: André Luiz Fraga Briso / Banca: Ticiane Cestari Fagundes Tozzi / Banca: Carlos Eduardo Francci / Resumo: Objetivo: O presente estudo teve como objetivo analisar a influência do modelo experimental e substrato nas alterações do esmalte dental decorrentes do tratamento clareador de consultório em diferentes tempos de análise. Materiais e Métodos: Um total de 140 discos contendo esmalte e dentina foram confeccionados, a dentina planificada e o esmalte polido e submetido ao teste de microdureza de superfície em KHN (MS) para padronização e seleção inicial dos espécimes (n= 80). A seguir, foram divididos em 8 grupos (n=10): G1- Controle in vitro em dentes humanos (VHC); G2- Clareamento in vitro utilizando agente clareador Pola Office a base de peróxido de hidrogênio a 35% (Pola PH 35%) em dentes humanos (VHP); G3- Controle in situ em dentes humanos (SHC); G4- Clareamento in situ com Pola PH 35% em dentes humanos (SHP); G5- Controle in vitro em dentes bovinos (VBC); G6- Clareamento in vitro com Pola PH 35% em dentes bovinos (VBP); G7- Controle in situ dentes bovinos (SBC); G8- Clareamento in situ com Pola PH 35% em dentes bovinos (SBP). O esmalte dental foi avaliado quantitativamente pelas análises de rugosidade, MS e microdureza longitudinal do esmalte em KHN (ML) e qualitativamente por microscopia eletrônica de varredura (MEV). As análises de rugosidade e MS foram realizadas antes do início do tratamento (T0), após a 3° semana de tratamento (T1) e 15 dias após o término do tratamento (T2). Já a análise de ML e as imagens de MEV foram realizadas apenas em T2. Os dados foram submetido... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The objective of the present study was to analyze, influence, model, experimental, substrate, birth, treatment, repair, surgery, different times, analysis. Materials and Methods: a total of 140 discotheques containing enamel and dentin were made, a planned dentin and polished omalmalte and submitted to the surface microhardness test in KHN (MS) for standardization and initial selection of spagos (n = 80). They were divided into 8 groups (n = 10): G1- In vitro control in human teeth (VHC); G2- In vitro bleaching, for example, Pola Office whitening agent, 35% hydrogen peroxide base (Pola PH 35%) in human teeth (VHP); G3-In situ control in human teeth (SHC); G4- In situ bleaching with Pola PH 35% in human teeth (SHP); G5- In vitro control in bovine teeth (VBC); G6- In vitro whitening with PH Pola 35% in bovine teeth (VBP); G7- In situ control of bovine teeth (SBC); G8- In situ bleaching with Pola PH 35% in bovine teeth (SBP). The enamel was evaluated quantitatively in the analysis of roughness, MS and longitudinal microhardness of the enamel in KHN (ML) and qualitatively by scanning electron microscopy (SEM). The roughness and MS analyzes were performed before the start of treatment (T0), after one week of treatment (T1) and 15 days after treatment (T2). Already an ML analysis and as SEM images were performed only in T2. The data were submitted to the Shapiro-wilk homoscedasticity test, then performed in analysis of variance (ANOVA) of measures and Tukey or Sidak test repetitions (p <0.05) or Friedman's test, by the post test Hoc analysis of Wilcoxon with Bonferroni correction. Results: In the relativity of in vitro and in situ models, a statistically significant difference can be observed 15 days after the end of the bleaching treatment (p <0.05) in all analyzes, In situ. Regarding the substrates, these... / Mestre
893

Fractografia quantitativa : relações entre diferentes condições de tratamento térmico e a dimensão fractal /

Oliveira, José Alberto de. January 2017 (has links)
Orientador: Luis Rogerio de Oliveira Hein / Coorientadora: Kamila Amato de Campos / Banca: Peterson Luiz Ferrandini / Banca: Rosinei Batista Ribeiro / Resumo: A morfologia de superfícies de fratura contém informações importantes do processo de fratura, tais como, o tipo de carregamento e a energia envolvida. Neste contexto, a fractografia quantitativa é uma ferramenta que permite caracterizar superfícies de fratura de forma qualitativa e quantitativa. O objetivo foi avaliar a sensibilidade da dimensão fractal na caracterização de diferentes micromecanismos de fratura, e correlacionar com a energia envolvida no processo de fratura, foram reproduzidas três condições de tratamento térmico do aço SAE 4340, visando obter micromecanismos de fratura característicos da ruptura dúctil e frágil. As superfícies de fratura foram geradas pelo ensaio de impacto charpy, ASTM A370, a temperatura ambiente. Com isso, através do método de reconstrução por extensão de foco na microscopia óptica, as superfícies de fratura foram reconstruídas, como resultado, foram obtidos mapas topográficos do relevo. A caracterização quantitativa da topografia foi realizada por meio da dimensão fractal, utilizando a abordagem monofractal, auto-similaridade, e bifractal que é calcada no conceito da auto-afinidade. As três condições de tratamento térmico foram eficazes, produzindo micromecanismos de fratura característicos da fratura dúctil, isto é, predominância de microvazios e da fratura frágil com predominância de clivagem. A abordagem monofractal se mostrou sensível a mudança de morfologia da superfície de fratura, no entanto, a sensibilidade foi pequena para morfo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The fracture surface morphology contains important information about the fracture process, such as the type of loading and the energy involved. In this context, quantitative fractography is a tool that allows qualitative and quantitative characterization of fracture surfaces. In order to evaluate the sensitivity of the fractal dimension in the characterization of different fracture micromechanisms and to correlate with the energy involved in the fracture process, three thermal treatment conditions of the steel SAE 4340 were reproduced in order to obtain fracture micromechanisms characteristic of the ductile and fragile fracture. The fracture surfaces were generated by the charpy impact test, ASTM A370, at room temperature. Thus, through the method of reconstruction by extension of focus in optical microscopy, the fracture surfaces were reconstructed, as a result, topographic maps of the relief were obtained. The quantitative characterization of the topography was performed through the fractal dimension, using the monofractal, selfsimilarity, and bifractal approach that is based on the concept of self-affinity. The three heat treatment conditions were effective, producing fracture micromechanisms characteristic of the ductile fracture, that is, predominance of microvoids and fragile fracture with predominance of cleavage. The monofractal approach was shown to be sensitive to change in fracture morphology, however, sensitivity was small for similar morphologies, in the distinction between quasi-cleavage and cleavage. On the other hand, in the bifractal approach the sensitivity of the fractal textural dimension was more expressive, evidencing the difference between quasi-cleavage and cleavage / Mestre
894

Avaliação da patogenicidade de amostras de Brachyspira pilosicoli através de técnicas histopatológicas convencionais e por imunohistoquímica.

Paulovich, Fabiana Beatriz January 2003 (has links)
O presente trabalho objetivou avaliar diferenças na patogenicidade de 19 cepas de B. pilosicoli isoladas de casos de diarréia em suínos no Estado do Rio Grande do Sul. Foi utiliza o modelo experimental em pintos de um dia, que possui boa eficiência quando usado para a infecção oral com a B. pilosicoli, pois permite a consistente colonização cecal dos animais inoculados. Através dessa infecção experimental, buscou-se estabelecer diferenças de patogenicidade entre cepas de referência da B. pilosicoli e cepas dessa espécie isoladas previamente de casos de diarréia em leitões no Rio Grande do Sul. Foram inoculadas 21 cepas de origem suína e duas cepas controle (uma a referência da espécie, P43/6/78 e um isolado humano, P16). Os animais foram inoculados por via oral com uma suspensão de bactérias vivas multiplicadas em meio líquido, num inóculo de 0,8 mL contendo 1x106 espiroquetas na fase logarítmica de crescimento. Decorridos 21 dias após a infecção experimental, os animais foram sacrificados e os cecos fixados em formalina 10% tamponada, processados para exame histológico e os cortes examinados através da coloração pela prata e com uma técnica imunohistoquímica. Com o uso da coloração pela prata, 65% dos animais mostraram colonização pela B. pilosicoli do epitélio do cecal. Houve diferenças no tipo de colonização, consistindo de aderência contínua, aderência focal ou presença de bactérias livres na luz intestinal. Com a técnica de imunohistoquímica, 76,2% das cepas mostraram colonização. Dessa forma, concluiu-se que a imunohistoquímica foi superior à coloração pela prata para a avaliação da colonização intestinal dos pintos, pois foi capaz de detectar 11,2% de cepas colonizadoras a mais do que a coloração pela prata Um segundo experimento visou avaliar a transmissão horizontal da infecção por B. pilosicoli. Para tal, foram mantidos em contato na mesma gaiola, pintos inoculados com a bactéria e animais chamados “contatos”, não inoculados. Com o uso da coloração pela prata, 23,8 % apresentaram-se positivos e, pela imunohistoquímica, 54,2 % foram positivos. Aqui também a imunohistoquímica revelou-se mais eficiente do que a coloração pela prata. Como conclusão desse experimento, as cepas de campo analisadas mostraram alta capacidade de difusão horizontal. Um achado inesperado foi a presença de figuras elongadas dentro do citoplasma das células epiteliais cecais entre alguns animais inoculados. Essas estavam presentes em 33,3 % das cepas, quando analisadas através da coloração pela prata. Pelos dados obtidos, não foi possível concluir que as figuras fossem Brachyspira pilosicoli, pois poderia tratar-se de outra bactéria intracelular ou artefato. Entretanto, como recentemente (no ano de 2003) foi realizado o primeiro registro por microscopia eletrônica de um achado de Brachyspira spp. intracelular, esse achado poderia significar uma alta capacidade invasiva entre as cepas analisadas. Novos estudos serão realizados e, caso comprovado, esse fato poderia auxiliar em muito o entendimento da patogenia da infecção pela B. pilosicoli, pouco clara até o momento.
895

Hemodiálise intermitente em cães com doença renal crônica estádio III e IV

Geraldes, Silvano Salgueiro 0 1900 (has links)
Orientador: Priscylla Tatiana Chalfun Guimarães [Unesp] Okamoto / Resumo: A Hemodiálise Intermitente (HDI) é uma modalidade de substituição renal, que vem sendo utilizada nas últimas décadas na veterinária nos casos de remoção de drogas, distúrbios hidroeletrolíticos, lesão renal aguda e doença renal crônica (DRC) em crise urêmica. O objetivo do estudo consistiu em avaliar o efeito da hemodiálise intermitente, instituída em cães DRC, em comparação aos manejados apenas com tratamento clínico, sem diálise, visando proporcionar uma melhor qualidade de vida. Foram selecionados 12 cães com DRC no estádio III e 25 cães DRC no estádio IV pelos critérios de inclusão, randomizados em grupo controle (n=6) no estádio III e (n=11) no estádio IV, onde foi preconizado apenas tratamento clínico e fluidoterapia, e grupo hemodiálise (n=6) no estádio III e (n=14) no estádio IV, em que além do tratamento clínico, foi realizada a hemodiálise intermitente. As coletas de sangue para avaliação laboratorial foram realizadas antes e após a fluidoterapia e antes e após a hemodiálise intermitente. As intercorrências e os parâmetros clínicos foram avaliadas a cada 30 minutos durante a HDI. A eficácia das sessões de HDI foi avaliada por meio da mensuração da taxa de remoção da ureia (URR). A instituição do tratamento dialítico promoveu uma eficaz diminuição das concentrações séricas de ureia, creatinina e fósforo em ambos estádios, porém com diminuição da sobrevida dos cães no estádio III. Apesar da evidente remoção dos compostos nitrogenados, é necessária uma constante avalia... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Intermittent Hemodialysis (IHD) is a modality of renal replacement that has been used in the last decades in the veterinarian in cases of drug withdrawal, hydroelectrolytic disorders, acute kidney injury and chronic kidney disease (CKD) in uremic crisis. The objective of the study was to evaluate the effect of intermittent hemodialysis, instituted in dogs CKD, in comparison to those managed only with clinical treatment, without dialysis, in order to provide a better quality of life. Twelve dogs with stage III CKD and 25 stage four CKD dogs were selected by inclusion criteria, randomized in a control group (n = 6) in stage III and (n = 11) in stage IV, where only clinical treatment was recommended and and hemodialysis group (n = 6) in stage III and (n = 14) in stage IV, in which, in addition to clinical treatment, intermittent hemodialysis was performed. Blood samples for laboratory evaluation were performed before and after fluid therapy and before and after intermittent hemodialysis. Intercurrences and clinical parameters were assessed every 30 minutes during IHD. The efficacy of the IHD sessions was assessed by measuring the urea removal rate (URR). The establishment of the dialytic treatment promoted an effective decrease in the serum concentrations of urea, creatinine and phosphorus in both stages, but with a decrease in the survival of dogs in stage III. Despite the obvious removal of the nitrogen compounds, a constant evaluation of the hematological and serum biochemica... (Complete abstract click electronic access below) / Mestre
896

Nódulos solitários hipercaptantes de tireóide : um estudo de prevalência, citopatologia e aspectos funcionais

Zelmanovitz, Flavio January 1995 (has links)
Resumo não disponível
897

Avaliação da adaptação marginal de copings cerâmicos obtidos por diferentes métodos de moldagem / Evaluation of the marginal adaptation of ceramic copings obtained by different molding methods

Pinto, Tatiana Saretta Ferreira [UNESP] 13 August 2018 (has links)
Submitted by Tatiana Saretta Ferreira Pinto (tatiorto13@hotmail.com) on 2018-10-11T15:04:44Z No. of bitstreams: 2 tese final para impressão.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) tese final para impressão.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-10-16T21:13:07Z (GMT) No. of bitstreams: 1 pinto_tsf_me_sjc.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) / Made available in DSpace on 2018-10-16T21:13:07Z (GMT). No. of bitstreams: 1 pinto_tsf_me_sjc.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) Previous issue date: 2018-08-13 / O objetivo desse estudo foi avaliar a adaptação marginal de copings cerâmicos obtidos pelos métodos de moldagem convencional e escaneamento. Os modelos foram separados em 3 grupos para avaliação e todas as coroas foram confeccionadas sobre um modelo mestre previamente fabricado em CoCr. Grupo 1: Com o auxílio de uma moldeira individual cilíndrica de acrílico foram reproduzidas 10 moldagens com silicona de adição (Panasil) no modelo mestre pela técnica de moldagem dupla e replicados dez modelos físicos em gesso pedra Fuji Rock.Sobre esses modelos foi realizado o enceramento dos copings, confecção dos sprues de cera e sobre eles foi realizada a injeção da cerâmica Grupo 2: foram realizadas 10 moldagens diretas com scanner extraoral (Swing Dental Scanner) no modelo mestre. As imagens foram obtidas através do software Exocad e copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Grupo 3: foram realizadas 10 moldagens diretas com scanner intraoral (CEREC Bluecam) no modelo mestre. As imagens foram obtidas através do software Exocad. Copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Os copings de cerâmica não foram cimentados no modelo mestre, apenas posicionados e mantidos com pressão constante de 1,4 a 1,5 kg durante a medição, com a ajuda de um delineador adaptado para esse trabalho, onde oito pontos eletivos foram usados como referência para medir a distância vertical entre a linha de término do modelo mestre e a linha de término dos copings. A margem em cada ponto foi medida 3 vezes com estéreomicroscópio Discovery V20 (ZEISS). A média de desadaptação marginal foi calculada e submetida ao teste de variância de um fator ANOVA com nível de significância de 5% e foram obtidos os seguintes resultados: 66,15µm para o grupo 1; 67,48µm para o grupo 2 e 72,91µm para o grupo 3,verificando assim que esses valores não diferem estatisticamente e todos estão dentro do limite de aceitabilidade clínica / The objective of the study was to evaluate the marginal adaptation of ceramic crowns obtained by conventional molding and scanning methods. The models were separated into 3 groups for evaluation and all the crowns were made on a master model previously manufactured in CoCr. For group 1: With the aid of a single cylindrical acrylic tray the master model was molded 10 times with Panasil in the master model by the technique of double molding and replicated ten physical models in stone gypsum Fuji Rock. On these models was done the waxing of the copings, making the sprues of wax and on them was carried out the injection of the ceramics In group 2, 10 direct impressions were performed with the Swing Dental Scanner (Korea) extra oral scanner in the master model. The images were obtained through the software Exocad (GmbH) and copings in IPS-Emax CAD were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramics. In group 3, 10 direct impressions were performed with the CEREC Bluecam intraoral scanner (Sirona Dental Systems) in the master model. The images were obtained through the Exocad (GmbH) software. IPS-Emax CAD copings were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramic. Ceramic copings were not cemented in the master model, only positioned and maintained with a constant pressure of 1.4 to 1.5 kg during the measurement, with the aid of an eyeliner adapted for this work, where eight elective points were used as reference to measure the vertical distance between the end line of the master model and the end line of the copings. The margin at each point was measured 3 times with stereo microscope Discovery V20 (ZEISS). The mean was calculated and submitted to the ANOVA variance test "with a significance level of 5% and the following results were obtained: 66.15μm for group 1; 67.48μm for group 2 and 72.91μm for group 3, thus verifying that these values do not differ statistically and all are within the limit of clinical acceptability.
898

Avaliação comparativa de protocolos rápidos versus protocolos convencionais para tipagem molecular de amostras clinicas de Staphylococcus aureus, Escherichia coli e Pseudomonas aeruginosa pela técnica de pulsed fiedl gel electrophoresis / Compoarative evaluation of rapid versus standardized protocols for molecular typing of clinical isolates of Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa using pulsed field gel electrophoresis technique

Monteiro, Jussimara [UNIFESP] January 2005 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:05:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2005 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivos: (a) Padronizar protocolos rápidos da técnica de eletroforese em campo pulsado (PFGE) para tipagem molecular de amostras clínicas de Staphylococcus aureus, Escherichia coli e Pseudomonas aeruginosa; (b) Avaliar a tipabilidade, o poder discriminatório e a reprodutibilidade entre os protocolos rápidos de PFGE versus o protocolo convencional para as amostras de S. aureus, E. coli e P. aeruginosa; (c) Analisar os resultados da tipagem molecular pela técnica do PFGE de acordo com dois critérios distintos de interpretação, os critérios de PFALLER et al. (1992) e os critérios de TENOVER et al. (1995). Métodos: Um total de 60 amostras bacterianas das seguintes espécies bacterianas foi selecionado: S. aureus (n=20), E. coli (n=20) e P. aeruginosa (n=20). Todos amostras foram isoladas da corrente sanguínea de pacientes internados no Hospital São Paulo (HSP) no período de 2000 a 2004. Quinze dos 20 isolados clínicos de cada espécie bacteriana foram selecionados de pacientes previamente caracterizados como não relacionados epidemiologicamente, pela Comissão de Controle de Infecção Hospitalar do HSP. As outras cinco amostras de cada espécie bacteriana foram classificadas como amostras bacterianas possivelmente relacionadas epidemiologicamente, provenientes de uma mesma unidade do HSP em um período de tempo igual ou inferior a três meses. Protocolos convencionais da técnica PFGE foram reproduzidos e protocolos rápidos desta mesma técnica foram padronizados, após digestão destas bactérias com as enzimas de restrição SmaI e SpeI. Os perfis moleculares foram analisados visualmente e interpretados de acordo com os critérios de Pfaller et al (1992) e Tenover et al (1995). Resultados: Os protocolos convencionais e rápidos de PFGE apresentaram resultados idênticos para tipagem das amostras clínicas de S.aureus, E. coli e P. aeruginosa. De acordo com os critérios de Pfaller et al. (1992), foram encontrados nas amostras clínicas de S. aureus, E. coli e P. aeruginosa deste estudo, 17, 13 e 7 padrões diferentes de PFGE, respectivamente. Seguindo os critérios de Tenover et al. (1995) foram encontrados 16, 11 e 6 padrões distintos de PFGE nas amostras de S. aureus, E. coli e P. aeruginosa, respectivamente. As técnicas desenvolvidas tanto pelos protocolos rápidos quanto pelos protocolos convencionais apresentaram percentual de tipabilidade e reprodutibilidade de 100%. O poder discriminatório foi de 95%, 94% e 82% para as amostras clínicas de S. aureus e E.coli e P. aeruginosa, respectivamente. Conclusões: Foram padronizados protocolos rápidos para tipagem molecular de amostras de S. aureus (42hs), E. coli (43hs) e P. aeruginosa (56hs) pela técnica de PFGE. Todos protocolos testados apresentaram excelente tipabilidade e reprodutibilidade. O poder discriminatório foi excelente para as amostras clínicas de S. aureus e E. coli, e satisfatório para as amostras de P. aeruginosa, devido a pouca diversidade clonal. Os critérios de Pfaller et al. (1992) diferenciaram melhor a presença de novos clones quando comparados aos critérios de Tenover et al. (1995). / Objectives: (a) To develop rapid protocols of pulsed-field gel electrophoresis (PFGE) technique for molecular typing of clinical samples of Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa; (b) To evaluate the typeability, the discriminatory power, and the reproducibility between rapid and conventional PFGE protocols for clinical isolates of S. aureus, E. coli and P. aeruginosa, (c) To analyze PFGE results according to two different interpretation criteria, one from Pfaller et al. (1992) and the other from Tenover et al. (1995). Methods: A total of 60 bacteria samples were selected from the following species: S. aureus (n=20), E. coli (n=20), and P. aeruginosa (n=20), isolated from bloodstream infections from patients from Hospital São Paulo (HSP). Among the 20 clinical isolates from each specie, 15 were selected from patients previously characterized by the hospital’s Infection Control Department of HSP as epidemiologically non-related. The other five isolates were characterized as possible epidemiologically related. These samples were collected from the same medical ward of HSP, in a period of time equal to or less than 3 months. The conventional PFGE protocols were reproduced, and the rapid protocols were developed, after DNA digestion with SmaI and SpeI enzymes. The molecular patterns were examined visually and interpreted according to Pfaller et al. (1992) and Tenover et al.(1995) criteria. Results: The rapid and conventional PFGE protocols presented similar results for S. aureus, E. coli, and P. aeruginosa isolates. According to Pfaller et al. (1992), a total of 17, 13, and 7 distinct PFGE patterns were identified for S. aureus, E. coli, and P. aeruginosa, respectively. On the other hand, by Tenover criteria, a total of 16, 11 and 6 distinct PFGE patterns were found for S. aureus, E. coli and P. aeruginosa, respectively. All protocols tested presented 100% of reproducibility and typeability. The discriminatory power was 95%, 94%, and 82% for S. aureus, E. coli, and P. aeruginosa, respectively. Conclusions: Rapid PFGE protocols were developed for S. aureus (42hs), E. coli (43hs) and P. aeruginosa (56hs), and all of them presented excellent reproducibility and typeability. The discriminatory power was excellent for clinical isolates of S. aureus and E. coli, and satisfactory for P. aeruginosa; probably because of the low clonal diversity of this specie identified in this study. Compared to Tenover et al. (1995) criteria, Pfaller et al. (1992) could better differentiate the presence of new bacterial clones. / FAPESP: 2006/57700-0 / BV UNIFESP: Teses e dissertações
899

Determinação do grau de ulceração gástrica pelo teste de permeabilidade gástrica à sacarose ou pelo teste de sangue oculto nas fezes comparado a gastroscopia em equinos / Ascertainment in horses of the degree of gastric ulceration through the gastric permeability to sucrose test or through the fecal occult blood test compared to gastroscopy

Abreu, Mayara Caetano January 2018 (has links)
A necessidade de investigação de métodos alternativos a gastroscopia, para o diagnóstico e mensuração da graduação da Síndrome da Úlcera Gástrica em Equinos, tem sido constatada. Diante desta realidade, este estudo objetivou verificar a eficiência dos testes de Permeabilidade Gástrica à Sacarose e pela intensidade de Sangue Oculto nas Fezes, na mensuração da graduação de lesões estomacais comparadas ao diagnóstico padrão ouro, a Gastroscopia. Para o desenvolvimento da pesquisa foram investigados 16 cavalos com idades entre 4 e 6 anos, os quais trabalham em pelotão de guarda, participam de práticas de hipismo e jogos de Polo. A seleção deste corpus foi baseada em cavalos que são submetidos a fatores de risco, como por exemplo: tempo indeterminado de descanso, alimentação de baixa qualidade, pouca oferta de feno, longos períodos de transporte. Para o exame de gastroscopia, foi realizado jejum alimentar de 20 horas e hídrico de 10 horas, mais a sondagem nasogástrica para obtermos o esvaziamento gástrico. Para o exame de Permeabilidade Gástrica à Sacarose, foi administrado 250g de sacarose por via nasogástrica, e foi coletado sangue no momento zero, 45 e 90min, para posterior análise por Cromatografia Líquida de Alta Eficiência. / The need of investigation of alternative methods to gastroscopy for the diagnosis and measurement of the degree of the Gastric Ulcer Syndrome in Horses has been found. In the face of this reality, this study aims to verify the efficiency of the Gastric Permeability to Sucrose tests and by the intensity in the Fecal Occult Blood in the measurement of the degree of stomach lesions compared to the diagnosis, golden standard, the gastroscopy. To the development of the research 16 horses were investigated between 4 and 6 years old, which worked in the guard squad, participated in equestrian practices and Polo games. The selection of this corpus was based in horses that are submitted to risk factors, such as: underdetermined rest time, low quality feeding, little hay offer, long transportation periods, among others. To the gastroscopy examination it was conducted 20 hours feeding fasts and 10 hours water fasts plus the nasogastric intubation to obtain gastric emptying. For the Gastric Permeability to Sucrose exam it was administered 250g of sucrose, via nasogastric tube, and was collected blood in the zero moment, 45 and 90 min., for later analysis by High Performance Liquid Chromatography through the method proposed by Hewetson et al., 2006. To the Fecal Occult Blood Test, we collected a fecal sample through the rectum to the analysis with the Meyer’s Reagent and we classified by crosses the intensity of occult blood. In the results we found out that the horses with the ulcer degree equal or higher than 3, the Gastric Permeability to Sucrose test proved itself device of reliable auxiliary diagnosis, yet the analysis of the intensity of the Fecal Occult Blood was not able to measure the degree of the stomach lesions. However, all the animals which presented gastric alterations had the presence of fecal occult blood. Para o exame de Sangue Oculto nas Fezes, coletamos uma amostra de fezes por via retal para análise com Reativo de Meyer, e classificamos por cruzes a intensidade de sangue oculto. Nos resultados, 43,75% não apresentaram quaisquer lesão estomacal, 31,25% apresentaram lesão grau 1 ou 2, e 25% apresentaram lesões grau 4. Encontramos que cavalos com o grau igual, ou maior a 3, de lesão gástrica, o teste de Permeabilidade Gástrica à Sacarose se demonstrou um meio de diagnóstico auxiliar confiável. Já a análise da intensidade de Sangue Oculto nas Fezes não foi capaz de mensurar a graduação de lesões estomacais. Porém todos os animais que apresentaram alterações gástricas tiveram a presença de sangue oculto nas fezes.
900

Colonoscopia virtual em cães /

Geller, Felipe Foletto. January 2013 (has links)
Orientador: Maria Jaqueline Mamprim / Banca: Cláudia Valéria Suellner / Banca: Maria Lucia Gomes Lourenço / Banca: Ricardo Coelho Lehmkuhl / Banca: Ana Carolina Brandão de Campos Fonseca Pinto / Resumo: Colonoscopia virtual é uma nova modalidade de imagem que permite a reconstrução tridimensional (3D) da superfície endoluminal do cólon, com imagens semelhantes àquelas conseguidas na colonoscopia endoscópica. A técnica é utilizada na detecção de lesões tumorais colorretais de seres humanos. O objetivo do estudo foi de avaliar a viabilidade da colonoscopia virtual em cães e descrever as imagens obtidas. Foram utilizados 10 cães adultos, sem raça definida e que não possuíam sinais clínicos ou histórico de doenças gastrointestinais. Os arquivos DICOM (Comunicação de imagens digital em medicina) gerados pelo tomógrafo foram reconstruídos em imagens de colonoscopia virtual no software Voxar 3D. Nas imagens da colonoscopia virtual nos cães, visibilizou-se a estrutura tubular com vários anéis dispostos ao longo do campo de visão e a parede do cólon lisa e regular. Conclui-se que a colonoscopia virtual pode ser realizada em cães e mostrou-se uma alternativa viável para o diagnóstico das doenças colônicas decorrentes de deslocamentos / Abstract: Virtual colonoscopy is a new imaging modality that allows reconstruction of three-dimensional (3D) endoluminal surface of the colon, with images similar to those achieved in endoscopic colonoscopy. The technique is used in the detection of colorectal tumors in human beings. The aim of the study was to evaluate the feasibility of virtual colonoscopy in dogs and describe the obtained images. We used 10 adult mongrel dogs, which had no clinical signs or history of gastrointestinal diseases. The DICOM (Digital Imaging and Communications in Medicine) files generated by the CT images were reconstructed in virtual colonoscopy in Voxar 3D software. In the virtual colonoscopy images in dogs the tubular structure with several rings arranged along the field of view could be seen, and the colon wall smooth and regular. We concluded that virtual colonoscopy can be performed in dogs and proved to be a viable alternative for the diagnosis of colonic diseases caused by dislocations / Doutor

Page generated in 0.0322 seconds