• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1943
  • 190
  • 57
  • 33
  • 33
  • 32
  • 27
  • 26
  • 13
  • 8
  • 7
  • 4
  • 3
  • 3
  • 3
  • Tagged with
  • 2239
  • 1160
  • 243
  • 241
  • 201
  • 158
  • 126
  • 122
  • 122
  • 116
  • 104
  • 102
  • 102
  • 85
  • 84
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise das tendências da chuva e das temperaturas extremas na região de Belém (PA) / Analysis of the tendencies of rainfall and extremes temperatures in Belém, PA, Brazil

Santos, Adriroseo Raimundo Alves dos 28 May 1993 (has links)
A cidade de Belém, situa-se numa das áreas mais chuvosas do Brasil, com índices anuais superiores a 2000 mm, e notabiliza-se pela sua isotermia, apresentando amplitude térmica anual em torno de 1,0°C a 3,0°C. Possui dois períodos distintos: o chuvoso (dezembro a maio) e o menos chuvoso (junho a novembro). No entanto, o regime de chuvas varia de ano para ano. Foi proposto estudar detalhadamente a série de dados meteorológicos de Belém desde 1896 até 1991 (registros mensais) e de 1967 até 1991 (registros diários), com intuito de entender a dinâmica das variações não só entre anos, mas também para verificar se existe uma tendência nos registros climáticos da região. Uma análise será feita com os valores extremos de temperatura, visto que os valores médios suavizam as tendências e flutuações. A distribuição das chuvas a nível diário também foi estudada detalhadamente. Para correlacionar a chuva mensal de Belém com as anomalias de temperatura da superfície do mar do Pacifico Sul (ATPS), utilizou-se índices de anomalia de temperatura da região do Niño 1+2, no período de janeiro de 1987 a dezembro de 1991. A intensidade de chuva diária e a frequência de dias sem chuva foi calculada através da distribuição de frequência relativa. As tendências temporais das temperaturas absolutas extremas e dos totais mensais de chuvas foram calculados através da regressão linear. Os resultados obtidos indicam uma tendência crescente no total de chuva anual, uma tendência ligeiramente decrescente na temperatura máxima absoluta e uma ligeira tendência crescente na temperatura mínima absoluta. O quadrimestre mais chuvoso em Belém, janeiro a abril, recebe pouca influência das ATPS na quantidade de chuva, sendo também, significante as variações de temperatura de superfície do mar no Oceano Atlântico. / On the average Belém, PA, has an annual rainfall above 2000 mm. Being located near the equator its air temperature has an annual amplitude between 1°C and 3°C. Basically, there are only two seasons being one, from december to may, with most of the rains, and another, from june to november, with much less rainfall. In order to study the climatic tendencies of the region the series of monthly rainfall and extreme (maximum and minimum) temperatures measured since 1896 were analysed. Results from linear regression analysis indicate an overall tendency of increasing both the annual rainfall and the absolute minimum temperature, white the absolute maximum temperature showed a smell decrease. Daily meteorological data for the period 1967- 1991 was also analysed in order to understand the dynamics of the rainfall in the region. The rainfall deviations from the climatological normal was associated with the El Nino - Southern Oscilation Index fot the Nino 1+2 area. It was found that ENSO had little effect upon the january-march rainfall because the Intertropical Convergence Zone dictates the dynamics of the weather in that period.
2

Propriedades magnéticas do Rb2MnBr42H2O / Magnetic properties of Rb2MnBr42H2O

Droichi, Meire da Silva 27 May 1983 (has links)
Neste trabalho, estudamos experimentalmente, as propriedades magnéticas do composto Rb2MnBr42H2O em baixas temperaturas. Determinamos a susceptibilidade magnética a campo zero em temperaturas de 1,5 K a 50 K. As medidas foram feitas em uma amostra monocristalina, orientada em várias direções em relação ao eixo de alinhamento magnético. Foi possível determinar as direções principais magnéticas do cristal e a temperatura de Néel (TN) onde ocorre um ordenamento antiferromagnético. Medidas da susceptibilidade magnética paralela e perpendicular ao eixo de fácil magnetização permitiram a determinação dos parâmetros de \"exchange\" (J) e do campo cristalino (D). Esses valores foram comparados com resultados obtidos por outros métodos experimentais. / Magnetic susceptibilities have been measured between 1,5 K and 50K along the principal magnetic axes. Antiferromagnetic ordering was observed below the Neel temperature TN. Zero field magnetic susceptibilities parallel and perpendicular to the easy axis, yelding the exchange parameter (J) and the crystal field parameter (D). These values are compared with results obtained by other experimental method.
3

Transição de fase no modelo de Ising com campo transverso. / Phase transition in the Ising model with transverse field.

Chiappin, Jose Raimundo Novaes 26 June 1979 (has links)
Utilizamos um formalismo variacional, juntamente com técnicas diagramáticas, para estudar o comportamento termodinâmico do modelo de Ising com campo transverso na presença de interações de longo alcance. Obtivemos uma expressão para a suscetibilidade acima da temperatura crítica Tc. Tambem obtivemos uma forma analítica para a temperatura critica, que nos permite traçar gráficos de kTc/J em função de r/J - onde J e a constante de troca das interações de curto alcance e r é o campo transverso para valores fixos do número de coordenação da rede e da razão n entre as interações de longo e de curto alcance. Os nossos resultados aproximados para a suscetibilidade foram comparados com a expansão exata em serie de altas temperaturas. / We use a variational formalism, together with diagrammatic technique, to study the thermodynamic behaviour of the Ising model in a transverse field with the addition of long range interactions. We obtain an expression for the susceptibility above the transition temperature. Also, we obtain an analytic expression for the critical temperature, which allows the construction of kTc/J versus f/J curves (where J is the exchange parameter of the short range interactions and r is the transverse field) for fixed values of the coordination number of the lattice and of the ratio n between long and short range interactions. Our approximate results for the susceptibility are compared with the exact expansion in a high temperature series.
4

Transições de fase em Mn (Br1-x Clx)2 . 4H2O: um antiferromagneto com anisotropia controlável / Phase transitions in Mn (Br1-x Clx)2 . 4H2O: an antiferromagnet with controllable anisotropy

Westphal, Carlos Henrique 11 September 1980 (has links)
Neste trabalho fizemos um estudo do diagrama de fase no plano campo magnético (H) vs. temperatura (T) e temperaturas acima de 0,3 K dos sistemas mistos MN(BR IND. 1-x CL IND. x) IND. 24 H IND. 2O. A técnica experimental utilizada foi a medida da susceptibilidade magnética diferencial. Estudamos a dependência da temperatura de Néel, dos campos críticos e do diagrama de fase em função da concentração x. Os resultados mostram que alterando a concentração x de Cloro podemos controlar a anisotropia do sistema entre as anisotropias do Cloreto e Brometo puros. Desta maneira pudemos fazer um estudo experimental dos diagramas de fase em função do campo magnético, da temperatura e da anisotropia do sistema. / Differential magnetic susceptibility measurements were performed on single crystals of the mixed system MN(BR IND. 1-x CL IND. x) IND. 24 H IND. 2O, at temperatures (T) above 0.3 K and in the presence of an external magnetic (H) field . We studied the dependence of the Néel temperature, the critical fields and the magnetic phase diagram in the T vs. H plane on the concentration x. The results indicate that the anisotropy of the mixed systems can be changed between the values of the anisotropy of the Chloride and the Bromide by changing the concentration x of the Chloride. We used this fact to perform an experimental study of the dependence of the phase diagrams on temperature, magnetic field and anisotropy.
5

Análise das tendências da chuva e das temperaturas extremas na região de Belém (PA) / Analysis of the tendencies of rainfall and extremes temperatures in Belém, PA, Brazil

Adriroseo Raimundo Alves dos Santos 28 May 1993 (has links)
A cidade de Belém, situa-se numa das áreas mais chuvosas do Brasil, com índices anuais superiores a 2000 mm, e notabiliza-se pela sua isotermia, apresentando amplitude térmica anual em torno de 1,0°C a 3,0°C. Possui dois períodos distintos: o chuvoso (dezembro a maio) e o menos chuvoso (junho a novembro). No entanto, o regime de chuvas varia de ano para ano. Foi proposto estudar detalhadamente a série de dados meteorológicos de Belém desde 1896 até 1991 (registros mensais) e de 1967 até 1991 (registros diários), com intuito de entender a dinâmica das variações não só entre anos, mas também para verificar se existe uma tendência nos registros climáticos da região. Uma análise será feita com os valores extremos de temperatura, visto que os valores médios suavizam as tendências e flutuações. A distribuição das chuvas a nível diário também foi estudada detalhadamente. Para correlacionar a chuva mensal de Belém com as anomalias de temperatura da superfície do mar do Pacifico Sul (ATPS), utilizou-se índices de anomalia de temperatura da região do Niño 1+2, no período de janeiro de 1987 a dezembro de 1991. A intensidade de chuva diária e a frequência de dias sem chuva foi calculada através da distribuição de frequência relativa. As tendências temporais das temperaturas absolutas extremas e dos totais mensais de chuvas foram calculados através da regressão linear. Os resultados obtidos indicam uma tendência crescente no total de chuva anual, uma tendência ligeiramente decrescente na temperatura máxima absoluta e uma ligeira tendência crescente na temperatura mínima absoluta. O quadrimestre mais chuvoso em Belém, janeiro a abril, recebe pouca influência das ATPS na quantidade de chuva, sendo também, significante as variações de temperatura de superfície do mar no Oceano Atlântico. / On the average Belém, PA, has an annual rainfall above 2000 mm. Being located near the equator its air temperature has an annual amplitude between 1°C and 3°C. Basically, there are only two seasons being one, from december to may, with most of the rains, and another, from june to november, with much less rainfall. In order to study the climatic tendencies of the region the series of monthly rainfall and extreme (maximum and minimum) temperatures measured since 1896 were analysed. Results from linear regression analysis indicate an overall tendency of increasing both the annual rainfall and the absolute minimum temperature, white the absolute maximum temperature showed a smell decrease. Daily meteorological data for the period 1967- 1991 was also analysed in order to understand the dynamics of the rainfall in the region. The rainfall deviations from the climatological normal was associated with the El Nino - Southern Oscilation Index fot the Nino 1+2 area. It was found that ENSO had little effect upon the january-march rainfall because the Intertropical Convergence Zone dictates the dynamics of the weather in that period.
6

Transições de fase em Mn (Br1-x Clx)2 . 4H2O: um antiferromagneto com anisotropia controlável / Phase transitions in Mn (Br1-x Clx)2 . 4H2O: an antiferromagnet with controllable anisotropy

Carlos Henrique Westphal 11 September 1980 (has links)
Neste trabalho fizemos um estudo do diagrama de fase no plano campo magnético (H) vs. temperatura (T) e temperaturas acima de 0,3 K dos sistemas mistos MN(BR IND. 1-x CL IND. x) IND. 24 H IND. 2O. A técnica experimental utilizada foi a medida da susceptibilidade magnética diferencial. Estudamos a dependência da temperatura de Néel, dos campos críticos e do diagrama de fase em função da concentração x. Os resultados mostram que alterando a concentração x de Cloro podemos controlar a anisotropia do sistema entre as anisotropias do Cloreto e Brometo puros. Desta maneira pudemos fazer um estudo experimental dos diagramas de fase em função do campo magnético, da temperatura e da anisotropia do sistema. / Differential magnetic susceptibility measurements were performed on single crystals of the mixed system MN(BR IND. 1-x CL IND. x) IND. 24 H IND. 2O, at temperatures (T) above 0.3 K and in the presence of an external magnetic (H) field . We studied the dependence of the Néel temperature, the critical fields and the magnetic phase diagram in the T vs. H plane on the concentration x. The results indicate that the anisotropy of the mixed systems can be changed between the values of the anisotropy of the Chloride and the Bromide by changing the concentration x of the Chloride. We used this fact to perform an experimental study of the dependence of the phase diagrams on temperature, magnetic field and anisotropy.
7

Transição de fase no modelo de Ising com campo transverso. / Phase transition in the Ising model with transverse field.

Jose Raimundo Novaes Chiappin 26 June 1979 (has links)
Utilizamos um formalismo variacional, juntamente com técnicas diagramáticas, para estudar o comportamento termodinâmico do modelo de Ising com campo transverso na presença de interações de longo alcance. Obtivemos uma expressão para a suscetibilidade acima da temperatura crítica Tc. Tambem obtivemos uma forma analítica para a temperatura critica, que nos permite traçar gráficos de kTc/J em função de r/J - onde J e a constante de troca das interações de curto alcance e r é o campo transverso para valores fixos do número de coordenação da rede e da razão n entre as interações de longo e de curto alcance. Os nossos resultados aproximados para a suscetibilidade foram comparados com a expansão exata em serie de altas temperaturas. / We use a variational formalism, together with diagrammatic technique, to study the thermodynamic behaviour of the Ising model in a transverse field with the addition of long range interactions. We obtain an expression for the susceptibility above the transition temperature. Also, we obtain an analytic expression for the critical temperature, which allows the construction of kTc/J versus f/J curves (where J is the exchange parameter of the short range interactions and r is the transverse field) for fixed values of the coordination number of the lattice and of the ratio n between long and short range interactions. Our approximate results for the susceptibility are compared with the exact expansion in a high temperature series.
8

Propriedades magnéticas do Rb2MnBr42H2O / Magnetic properties of Rb2MnBr42H2O

Meire da Silva Droichi 27 May 1983 (has links)
Neste trabalho, estudamos experimentalmente, as propriedades magnéticas do composto Rb2MnBr42H2O em baixas temperaturas. Determinamos a susceptibilidade magnética a campo zero em temperaturas de 1,5 K a 50 K. As medidas foram feitas em uma amostra monocristalina, orientada em várias direções em relação ao eixo de alinhamento magnético. Foi possível determinar as direções principais magnéticas do cristal e a temperatura de Néel (TN) onde ocorre um ordenamento antiferromagnético. Medidas da susceptibilidade magnética paralela e perpendicular ao eixo de fácil magnetização permitiram a determinação dos parâmetros de \"exchange\" (J) e do campo cristalino (D). Esses valores foram comparados com resultados obtidos por outros métodos experimentais. / Magnetic susceptibilities have been measured between 1,5 K and 50K along the principal magnetic axes. Antiferromagnetic ordering was observed below the Neel temperature TN. Zero field magnetic susceptibilities parallel and perpendicular to the easy axis, yelding the exchange parameter (J) and the crystal field parameter (D). These values are compared with results obtained by other experimental method.
9

O aumento de temperatura resultante dos fenomenos da natureza termica envolvidos na extrusão a quente de chumbo

Almeida, Norton de, 1947- 14 July 2018 (has links)
Orientador: Ettore Bresciani Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T03:00:41Z (GMT). No. of bitstreams: 1 Almeida_Nortonde_M.pdf: 1847892 bytes, checksum: 15f2faa10b2dce5c930989eb716f21e3 (MD5) Previous issue date: 1981 / Resumo: O presente trabalho tem como objetivo o estudo do aumento de temperatura resultante dos fenômenos de natureza térmica envolvidos na conformação plástica dos metais, em especial na extrusão a quente de metais não-ferrosos. São analisados esses fenômenos, e apresentadas as soluções existentes para o cálculo do aumento de temperatura deles decorrente. É proposta uma sistemática de utilização dessas soluções, de maneira a se obter uma razoável precisão de resultados, sem se atingir demasiada complexidade de cálculos. A fim de se avaliar tal sistemática, foi efetuado um conjunto de experiências com a extrusão a quente de chumbo. É apresentada uma comparação entre a previsão teórica e is resultados experimentais. / Abstract: The present work has as a main objective the study of the temperature ruse due to the thermal phenomena associated with the plastic forming of the metals, in special with the extrusion of non-ferrous metals. Those phenomena has been analyzed, and the known solutions has been presented, One method of utilization of those solutions has been proposed, with the purpose of obtaining a reasonable precision of the results, without being necessary too much complexity in the calculations. One set of practical experiences with the hot extrusion of lead has been done, to test that method. A comparison between the theoretical prevision and the practical results has been presented. / Mestrado / Mestre em Engenharia Mecânica
10

Diseño de un contrastador de temperatura para termómetros de termocuplas tipo K

Bedoya Martínez, Daniel Arturo 18 February 2014 (has links)
Este trabajo de tesis muestra el diseño de un equipo contrastador de temperatura para el Laboratorio de Energía de Ingeniería Mecánica de la Facultad de Ciencias e Ingeniería de la PUCP. Cuando se habla de mediciones de temperatura, el instrumento más utilizado para este fin, es la termocupla, la cual muestra los valores de temperatura medidos, por medio de su termómetro digital acoplado. Este termómetro, con el tiempo y uso, suele descalibrarse y es responsabilidad del operario del instrumento efectuar calibraciones periódicas del aparato con el fin de asegurar la confiabilidad de las mediciones. Por ese motivo se diseñó, en este trabajo, un equipo contrastador térmico de una termocupla tipo K. Este dispositivo simula el comportamiento de dicha termocupla y podrá ser acoplado a los termómetros digitales, permitiendo a los usuarios de tales termómetros, contrastarlos, para determinar si necesitan calibrarse. El equipo permitirá el ingreso de valores con saltos de 10 ° C, y tendrá un rango de - 30 a 250 ° C. Para el presente proyecto, primero se identificó las partes más importantes que conforman tales equipos, y posteriormente con ayuda de un diagrama de bloques se diseñó la estructura interna del simulador. Para cada parte del diagrama se hizo una selección de componentes que permitieron cumplir con los requisitos de cada bloque respectivo. Seguidamente se escogió, justificando con los debidos criterios de selección, los componentes más apropiados para cada bloque. Una vez escogidas todas las partes del diagrama se procedió a realizar simulaciones de determinados bloques junto con un análisis de error, de cada uno de los componentes, para conocer la máxima desviación o el máximo error que se podría obtener en la salida del equipo, consiguiendo un valor satisfactorio de error igual a 1.78 ° C, en el peor de los casos. Es importante mencionar que este proyecto se llevó a cabo con el fin de ser una referencia para personas que deseen efectuar una investigación más profunda en lo que respecta a la generación de centenas de microvoltios de un transductor. / Tesis

Page generated in 0.0857 seconds