• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 7
  • 7
  • 7
  • 7
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

\"Avaliação da espectrometria de absorção atômica com atomização eletrotérmica em filamento de tungstênio para determinação de alumínio\" / \"Evaluation of tungsten coil electrothermal atomic absorption spectrometry for aluminium determination\"

Godoi, Quienly 27 October 2006 (has links)
Este trabalho teve como objetivo avaliar o filamento de tungstênio de 150 W (OSRAM) como atomizador eletrotérmico para determinação de alumínio em amostras de águas, incluindo um estudo sistemático sobre o seu comportamento eletrotérmico na presença de até 1000 mg l-1 de sódio, potássio, cálcio, magnésio e/ou da mistura destes elementos. Alguns parâmetros, como comprimento de onda, corrente da lâmpada de catodo oco, altura de observação e temperatura de atomização do alumínio foram avaliados visando à melhoria da qualidade dos resultados e do limite de detecção. Após uma primeira avaliação, fixaram-se o comprimento de onda em 309,3 nm e a corrente da lâmpada de catodo oco em 10 mA, elegendo-se altura de observação de 1,5 mm e temperatura de atomização de 2860 oC (13,0 V). No programa de aquecimento usado no desenvolvimento deste trabalho adotou-se rampa invertida de voltagem variando entre 0,65 a 0,30 V durante 50 s para secagem de 10 µl, 2,8 V durante 10 s para pirólise e 13,0 V durante 1 s para atomização. As soluções usadas no desenvolvimento deste trabalho formam preparadas, em sua maioria, em meio 0,1 % v/v HNO3. A avaliação dos potenciais interferentes Na, K, Ca, Mg e a mistura desses elementos foi realizada nas alturas de observação de 0,0 a 2,0 mm e nas composições do gás de proteção de 90% Ar/10% H2, 80% Ar/20% H2, 65% Ar/35% H2. Pode-se inferir que o aumento do hidrogênio na composição do gás de proteção não acarretou melhora significativa na ação dos interferentes na atomização do alumínio. Não foram observadas interferências significativas em até 1000 mg l-1 Na e K na atomização de 100 µg l-1 Al na altura de observação de 0,0 mm. Na mesma condição de altura de observação, a mistura dos interferentes não afetou significativamente a atomização do alumínio. Observaram-se interferências em torno de 40 % na atomização de 100 µg l-1 Al em 0,1 % v/v HNO3 na altura de observação de 0,0 mm na presença de até 100 mg l-1 de Ca e Mg. Nessa mesma condição, mas com a mistura 65 % Ar/35 % H2, a supressão do sinal de absorbância de alumínio foi da ordem 90%. Os resultados obtidos na determinação de alumínio em amostras de água foram obtidos nas condições anteriormente citadas, utilizando gás de proteção 90% Ar/ 10% H2. Nestas condições, o limite de detecção foi de 2,3 µg l-1 Al e a massa característica de 69 pg Al. Os resultados encontrados foram satisfatórios e concordantes com aqueles encontrados quando se utilizou o forno de grafite como método de comparação. Aproximadamente 500 queimas foram feitas com um único filamento de tungstênio. / The aim of this paper was to evaluate the 150 W (OSRAM) tungsten coil as electrothermal atomizer in order to determine aluminum in water samples as well as a systematic study of its electrothermal behavior in the presence of up to 1000 mg l-1 of sodium, potassium, calcium, magnesium and/or of mixture of these elements. Some parameters, such as wavelength, hollow cathode lamp current, observation height and atomization temperature were evaluated in order to improve the quality of results and the detection limit. After a first evaluation, measurements were always carried out at 309,3 nm as well as the hollow cathode lamp current at 10 mA, and it was adopted an observation height of 1,5 mm and atomization temperature at 2860 oC (13,0 V). In the heating program defined experimentally, the inverted voltage ramp was adopted for drying 10 μl of sample solution by varying the applied voltage from 0,65 to 0,30 V during 50 s, with further application of 2,8 V for 10 s in the pyrolysis step and 13,0 V for 1 s in the atomization step. Most solutions were prepared in 0,1% v/v HNO3. The evaluation of the potential interfering elements such as Na, K, Ca, Mg an the mixture of these elements, was carried out in observations heights from 0,0 to 2,0 mm at different gas compositions: 90% Ar/ 10% H2 , 80 % Ar/ 20% H2 and 65 % Ar/ 35% H2. It can be inferred that the hydrogen increase in the protection gas did not change the interference behavior of the studied concomitants on aluminum atomization. Significant interferences were not observed up to 1000 mg l-1 of Na and K in the atomization of 100 μg l-1 Al when the optical beam was intercepting the atomizer (0,0 mm observation height). In the same condition, the mixture of the interfering species did not significantly affect the aluminum atomization. In addition, 100 mg l-1 of Ca and Mg depressed the absorbance of 100 μg l-1 Al in 0,1 % v/v HNO3 by approximately 40 %. When the atomization was made in the presence of 65 % Ar/ 35 % H2, the suppression of the aluminum absorbance signal was about 90 %. The results obtained in the determination of aluminum in water samples were achieved in the conditions previously mentioned, using protection gas of 90 % / 10 % H. In these conditions, the detection limit was 2,3 μg l-1 Al and the characteristic mass was 69 pg Al. The results were reasonable and in agreement with those found by atomic absorption with graphite furnace as a comparative method. Approximately 500 firings were made with a single tungsten coil.
2

\"Avaliação da espectrometria de absorção atômica com atomização eletrotérmica em filamento de tungstênio para determinação de alumínio\" / \"Evaluation of tungsten coil electrothermal atomic absorption spectrometry for aluminium determination\"

Quienly Godoi 27 October 2006 (has links)
Este trabalho teve como objetivo avaliar o filamento de tungstênio de 150 W (OSRAM) como atomizador eletrotérmico para determinação de alumínio em amostras de águas, incluindo um estudo sistemático sobre o seu comportamento eletrotérmico na presença de até 1000 mg l-1 de sódio, potássio, cálcio, magnésio e/ou da mistura destes elementos. Alguns parâmetros, como comprimento de onda, corrente da lâmpada de catodo oco, altura de observação e temperatura de atomização do alumínio foram avaliados visando à melhoria da qualidade dos resultados e do limite de detecção. Após uma primeira avaliação, fixaram-se o comprimento de onda em 309,3 nm e a corrente da lâmpada de catodo oco em 10 mA, elegendo-se altura de observação de 1,5 mm e temperatura de atomização de 2860 oC (13,0 V). No programa de aquecimento usado no desenvolvimento deste trabalho adotou-se rampa invertida de voltagem variando entre 0,65 a 0,30 V durante 50 s para secagem de 10 µl, 2,8 V durante 10 s para pirólise e 13,0 V durante 1 s para atomização. As soluções usadas no desenvolvimento deste trabalho formam preparadas, em sua maioria, em meio 0,1 % v/v HNO3. A avaliação dos potenciais interferentes Na, K, Ca, Mg e a mistura desses elementos foi realizada nas alturas de observação de 0,0 a 2,0 mm e nas composições do gás de proteção de 90% Ar/10% H2, 80% Ar/20% H2, 65% Ar/35% H2. Pode-se inferir que o aumento do hidrogênio na composição do gás de proteção não acarretou melhora significativa na ação dos interferentes na atomização do alumínio. Não foram observadas interferências significativas em até 1000 mg l-1 Na e K na atomização de 100 µg l-1 Al na altura de observação de 0,0 mm. Na mesma condição de altura de observação, a mistura dos interferentes não afetou significativamente a atomização do alumínio. Observaram-se interferências em torno de 40 % na atomização de 100 µg l-1 Al em 0,1 % v/v HNO3 na altura de observação de 0,0 mm na presença de até 100 mg l-1 de Ca e Mg. Nessa mesma condição, mas com a mistura 65 % Ar/35 % H2, a supressão do sinal de absorbância de alumínio foi da ordem 90%. Os resultados obtidos na determinação de alumínio em amostras de água foram obtidos nas condições anteriormente citadas, utilizando gás de proteção 90% Ar/ 10% H2. Nestas condições, o limite de detecção foi de 2,3 µg l-1 Al e a massa característica de 69 pg Al. Os resultados encontrados foram satisfatórios e concordantes com aqueles encontrados quando se utilizou o forno de grafite como método de comparação. Aproximadamente 500 queimas foram feitas com um único filamento de tungstênio. / The aim of this paper was to evaluate the 150 W (OSRAM) tungsten coil as electrothermal atomizer in order to determine aluminum in water samples as well as a systematic study of its electrothermal behavior in the presence of up to 1000 mg l-1 of sodium, potassium, calcium, magnesium and/or of mixture of these elements. Some parameters, such as wavelength, hollow cathode lamp current, observation height and atomization temperature were evaluated in order to improve the quality of results and the detection limit. After a first evaluation, measurements were always carried out at 309,3 nm as well as the hollow cathode lamp current at 10 mA, and it was adopted an observation height of 1,5 mm and atomization temperature at 2860 oC (13,0 V). In the heating program defined experimentally, the inverted voltage ramp was adopted for drying 10 μl of sample solution by varying the applied voltage from 0,65 to 0,30 V during 50 s, with further application of 2,8 V for 10 s in the pyrolysis step and 13,0 V for 1 s in the atomization step. Most solutions were prepared in 0,1% v/v HNO3. The evaluation of the potential interfering elements such as Na, K, Ca, Mg an the mixture of these elements, was carried out in observations heights from 0,0 to 2,0 mm at different gas compositions: 90% Ar/ 10% H2 , 80 % Ar/ 20% H2 and 65 % Ar/ 35% H2. It can be inferred that the hydrogen increase in the protection gas did not change the interference behavior of the studied concomitants on aluminum atomization. Significant interferences were not observed up to 1000 mg l-1 of Na and K in the atomization of 100 μg l-1 Al when the optical beam was intercepting the atomizer (0,0 mm observation height). In the same condition, the mixture of the interfering species did not significantly affect the aluminum atomization. In addition, 100 mg l-1 of Ca and Mg depressed the absorbance of 100 μg l-1 Al in 0,1 % v/v HNO3 by approximately 40 %. When the atomization was made in the presence of 65 % Ar/ 35 % H2, the suppression of the aluminum absorbance signal was about 90 %. The results obtained in the determination of aluminum in water samples were achieved in the conditions previously mentioned, using protection gas of 90 % / 10 % H. In these conditions, the detection limit was 2,3 μg l-1 Al and the characteristic mass was 69 pg Al. The results were reasonable and in agreement with those found by atomic absorption with graphite furnace as a comparative method. Approximately 500 firings were made with a single tungsten coil.
3

Construção de um espectrômetro de absorção atômica e estudos de formação e evolução da nuvem atômica com atomização eletrotérmica em sistema de duplo filamento de tungstênio / Construction of an atomic absorption spectrometer and studies on the formation and evolution of the atomic cloud with electrothermal atomization in a double tungsten coil system

Jora, Manassés Zuliani, 1987- 25 August 2018 (has links)
Orientadores: Celio Pasquini, Joaquim de Araújo Nóbrega / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-25T12:04:34Z (GMT). No. of bitstreams: 1 Jora_ManassesZuliani_M.pdf: 4929889 bytes, checksum: f8da5d6a35fbac5ae2d05d997971561a (MD5) Previous issue date: 2013 / Resumo: A espectrometria de absorção atômica com atomização eletrotérmica (ET AAS) é adequada para a determinação de metais e semimetais, apresentando alta sensibilidade. Dentre os atomizadores eletrotérmicos, os fornos de grafite destacam-se por sua boa seletividade, exigência de pequenos volumes de amostra e baixos limites de detecção (i.e. 'mu'g L-1). Porém, esses atomizadores requerem fontes de alta potência (i.e. superiores a 2 kW), sistema de resfriamento e, ainda, apresentam alto custo. Como alternativa, o uso de superfícies metálicas têm sido objeto de pesquisa desde 1970. Dentre todos os metais empregados na fabricação de superfícies metálicas e utilizados para os estudos em ET AAS, o tungstênio é o que vem apresentando maior aplicação. Porém, a espectrometria de absorção atômica baseada em atomizadores de filamento de tungstênio (WC AAS) apresenta vários desafios relacionados ao entendimento da geração da nuvem atômica e dos efeitos de interferência observados. Dessa maneira, neste trabalho construiu-se um espectrômetro de absorção atômica com duplo filamento de tungstênio (DWC AAS), com duas configurações, uma empregando como sistema de detecção um sistema echelle/detector de carga acoplada intensificado (ICCD) e outra um sistema filtro óptico-acústico sintonizável (AOTF)/fotomultiplicadora. Essas duas configurações do equipamento foram empregadas em estudos de formação e evolução da nuvem atômica de elementos com características voláteis e refratárias (i.e. Pb e Cr). Além disso, estudou-se o efeito de Na, K, Ca e Mg, em três diferentes concentrações (i.e. 1, 10 e 100 mg L-1) sobre os perfis das nuvens atômicas de Pb e Cr. Esse estudo foi conduzido de tal forma que interferências em fase condensada e gasosa puderam ser avaliadas. Além disso, o equipamento foi empregado em medidas de temperatura na superfície do filamento e na fase gasosa / Abstract: Electrothermal atomic absorption spectrometry (ET AAS) is suitable for determination of metals and semimetals with high sensitivity. Among the existing electrothermal atomizers, graphite furnace stands out due to its selectivity, requirement of low volume of sample and low limits of detection (i.e. 'mu'g L-1). Notwithstanding, these atomizers present high cost and requires high power power supply (i.e. above 2 kW) and a cooling system. Alternatively, metallic surfaces have been studied since 1970. Among all metals employed as atomizers in ET AAS studies, tungsten has presented the best results and has found many analytical applications. However, tungsten coil atomic absorption spectrometry (WC AAS) presents several challenges related to understanding the atomic cloud generation and interferences effects. Thus, in this work, a double tungsten coil atomic absorption spectrometer (DWC AAS), with two different configurations was constructed. In one configuration, a detection system based on echelle/intensified charge-coupled device (ICCD) is employed and, in the other, an acousto-optic tunable filter (AOTF)/photomultiplier detection system is used. Both configurations were employed in the atomic cloud generation and evolution studies of Pb and Cr. Furthermore, interferences on the atomic cloud profile of Pb and Cr caused by Na, K, Ca and Mg, at three different concentrations (i.e. 1, 10 and 100 mg L-1), were studied. This study helped to evaluate the effect of condensed and gas phase interferences. Additionally, the equipment was employed to perform measures of surface and gas phase temperatures / Mestrado / Quimica Analitica / Mestre em Química
4

Avaliação da espectrometria de absorção atômica com atomização eletrotérmica em filamento de tungstênio para determinação de arsênio em águas / Evaluation of eletrothermal atomic absorption spectrometry with tungsten coil for the direct determination of arsenic in waters

Antonio, Rosana Fernandes 19 September 2008 (has links)
A determinação direta de arsênio total em águas por espectrometria de absorção atômica com filamentos de tungstênio (150 W) modificados quimicamente com irídio ou ródio, representa uma alternativa para a atomização eletrotérmica de arsênio, que foi avaliada na presente dissertação. A utilização do revestimento com Ir como modificador químico proporcionou um aumento da massa característica de arsênio de 3,5 vezes. As medidas foram feitas com altura de observação selecionada para proporcionar a melhor razão sinal/ruído sem diminuir a sensibilidade do sinal analítico. Avaliaram-se dois programas de aquecimento: com temperatura de secagem constante (com diminuição gradativa da tensão aplicada) e com temperatura de secagem variável (com tensão aplicada de maneira constante). Não houve diferença na sensibilidade entre os dois programas estudados, indicando que a modificação química leva à formação de um precursor atômico com estabilidade térmica elevada. De fato, utilizando-se a modificação química permanente com 1000 müg Ir, e adotando-se programa de aquecimento com temperatura de secagem variável, a temperatura máxima de pirólise foi de aproximadamente 1700 °C ( temperatura de atomização de 2700 °C). Avaliou-se o comportamento eletrotérmico do As na presença dos concomitantes Na, K, Ca e Mg em 0,1% v/v HNO3. Interferências mais severas foram observadas na presença de cálcio acima de 10 \'mü\'g l-1, e acima de 100 \'mü\'g l-1 para os demais concomitantes. As interferências podem estar relacionadas com o elevado gradiente de temperatura entre a superfície do filamento e a fase gasosa do volume de observação, ou mesmo devido à formação de compostos refratários, particularmente para Ca e Mg, na fase condensada, ou seja, na superfície do atomizador. O emprego do método das médias móveis no tratamento dos sinais transientes gerados na atomização do arsênio também foi avaliada. Com o filamento posicionado na altura de observação 2 mm, foram utilizados os fatores 0, 3, 5, 7 e 9, observando-se melhora considerável nos limites de detecção instrumental e do método,utilizando-se média móvel com fator 7. Nestas condições, e depositando-se 20 \'mü\'l de amostra sobre o filamento, o limite de detecção foi de 3,2 \'mü\'g l-1 As e a massa característica de 37,0 pg As. A exatidão foi avaliada analisando-se diferentes amostras de águas provenientes da região do Quadrilátero Ferrífero do Estado de Minas Gerais, por espectrometria de fluorescência atômica com geração de hidretos e por espectrometria de absorção atômica com o filamento de tungstênio modificado com Ir. A comparação dos resultados mostrou que o método proposto pode ser utilizado para o controle de qualidade de águas desta região. Aproximadamente 150 queimas podem ser feitas com um único filamento de tungstênio / The direct determination of arsenic in waters by atomic absorption spectrometry with 150 W tungsten coils, treated with Ir or Rh, was evaluated as a possible alternative for the eletrothermal atomization of As. The use of iridium as a permanent chemical modifier did improve the characteristic mass of arsenic by 3.5 fold. Measurements were made by choosing an appropriate observation height in order to get the best signal to noise ratio. Two heating programs were tested, either by keeping the applied voltage constant or by using an inverted voltage ramp during the drying step. There were no significant differences in the sensitivities between both heating programs, indicating that the permanent modification lead to the formation of an atomic precursor of high thermal stability. Indeed, with the permanent chemical modification with 1000 \'mü\'g Ir, the maximum pyrolysis temperature was approximately 1700 °C (atomization temperature 2700 °C), allowing a heating program with temperature variation during the drying step. Method selectivity was carried out by evaluating the eletrothermal behavior of As in the presence of up to 1000 \'mü\'g l-1 Na, K, Ca and/or Mg in 0,1% v/v HNO3. The most serious interferences were observed with Ca in concentrations higher than 10 \'mü\'g l-1 and when the concentrations were higher than 100 \'mü\'g l-1 for Na, K or Mg, which can be attributed either to the gradient of temperature between the surface of the atomizer and the observation volume or to the formation of refractory compounds in the condensed phase, particularly with Ca and Mg. The absorbance transient signals treatment by the method of moving averages up to factor 9 was also evaluated, with a remarkable improvement in the instrumental and method detection limits. With the center of the observation volume 2 mm above the tungsten coil surface, and a moving average of factor 7, the limit of detection was 3,2 \'müg\' l-1 As and the characteristic mass 37,0 pg As. Accuracy was evaluate by analysing water samples collected in a contaminated area from the Quadrilátero Ferrífero, Minas Gerais State, by hydride generation atomic fluorescence spectrometry and by tungsten coil eletrothermal atomic absorption spectrometry. Results showed that the proposed method fits for the purpose of CONAMA 357 regulation for drinking water quality in the aforementioned contaminated area. Approximately 150 firings can be done with a single tungsten coil atomizer by using 20 \'mü\'l sample volume
5

Avaliação da espectrometria de absorção atômica com atomização eletrotérmica em filamento de tungstênio para determinação de arsênio em águas / Evaluation of eletrothermal atomic absorption spectrometry with tungsten coil for the direct determination of arsenic in waters

Rosana Fernandes Antonio 19 September 2008 (has links)
A determinação direta de arsênio total em águas por espectrometria de absorção atômica com filamentos de tungstênio (150 W) modificados quimicamente com irídio ou ródio, representa uma alternativa para a atomização eletrotérmica de arsênio, que foi avaliada na presente dissertação. A utilização do revestimento com Ir como modificador químico proporcionou um aumento da massa característica de arsênio de 3,5 vezes. As medidas foram feitas com altura de observação selecionada para proporcionar a melhor razão sinal/ruído sem diminuir a sensibilidade do sinal analítico. Avaliaram-se dois programas de aquecimento: com temperatura de secagem constante (com diminuição gradativa da tensão aplicada) e com temperatura de secagem variável (com tensão aplicada de maneira constante). Não houve diferença na sensibilidade entre os dois programas estudados, indicando que a modificação química leva à formação de um precursor atômico com estabilidade térmica elevada. De fato, utilizando-se a modificação química permanente com 1000 müg Ir, e adotando-se programa de aquecimento com temperatura de secagem variável, a temperatura máxima de pirólise foi de aproximadamente 1700 °C ( temperatura de atomização de 2700 °C). Avaliou-se o comportamento eletrotérmico do As na presença dos concomitantes Na, K, Ca e Mg em 0,1% v/v HNO3. Interferências mais severas foram observadas na presença de cálcio acima de 10 \'mü\'g l-1, e acima de 100 \'mü\'g l-1 para os demais concomitantes. As interferências podem estar relacionadas com o elevado gradiente de temperatura entre a superfície do filamento e a fase gasosa do volume de observação, ou mesmo devido à formação de compostos refratários, particularmente para Ca e Mg, na fase condensada, ou seja, na superfície do atomizador. O emprego do método das médias móveis no tratamento dos sinais transientes gerados na atomização do arsênio também foi avaliada. Com o filamento posicionado na altura de observação 2 mm, foram utilizados os fatores 0, 3, 5, 7 e 9, observando-se melhora considerável nos limites de detecção instrumental e do método,utilizando-se média móvel com fator 7. Nestas condições, e depositando-se 20 \'mü\'l de amostra sobre o filamento, o limite de detecção foi de 3,2 \'mü\'g l-1 As e a massa característica de 37,0 pg As. A exatidão foi avaliada analisando-se diferentes amostras de águas provenientes da região do Quadrilátero Ferrífero do Estado de Minas Gerais, por espectrometria de fluorescência atômica com geração de hidretos e por espectrometria de absorção atômica com o filamento de tungstênio modificado com Ir. A comparação dos resultados mostrou que o método proposto pode ser utilizado para o controle de qualidade de águas desta região. Aproximadamente 150 queimas podem ser feitas com um único filamento de tungstênio / The direct determination of arsenic in waters by atomic absorption spectrometry with 150 W tungsten coils, treated with Ir or Rh, was evaluated as a possible alternative for the eletrothermal atomization of As. The use of iridium as a permanent chemical modifier did improve the characteristic mass of arsenic by 3.5 fold. Measurements were made by choosing an appropriate observation height in order to get the best signal to noise ratio. Two heating programs were tested, either by keeping the applied voltage constant or by using an inverted voltage ramp during the drying step. There were no significant differences in the sensitivities between both heating programs, indicating that the permanent modification lead to the formation of an atomic precursor of high thermal stability. Indeed, with the permanent chemical modification with 1000 \'mü\'g Ir, the maximum pyrolysis temperature was approximately 1700 °C (atomization temperature 2700 °C), allowing a heating program with temperature variation during the drying step. Method selectivity was carried out by evaluating the eletrothermal behavior of As in the presence of up to 1000 \'mü\'g l-1 Na, K, Ca and/or Mg in 0,1% v/v HNO3. The most serious interferences were observed with Ca in concentrations higher than 10 \'mü\'g l-1 and when the concentrations were higher than 100 \'mü\'g l-1 for Na, K or Mg, which can be attributed either to the gradient of temperature between the surface of the atomizer and the observation volume or to the formation of refractory compounds in the condensed phase, particularly with Ca and Mg. The absorbance transient signals treatment by the method of moving averages up to factor 9 was also evaluated, with a remarkable improvement in the instrumental and method detection limits. With the center of the observation volume 2 mm above the tungsten coil surface, and a moving average of factor 7, the limit of detection was 3,2 \'müg\' l-1 As and the characteristic mass 37,0 pg As. Accuracy was evaluate by analysing water samples collected in a contaminated area from the Quadrilátero Ferrífero, Minas Gerais State, by hydride generation atomic fluorescence spectrometry and by tungsten coil eletrothermal atomic absorption spectrometry. Results showed that the proposed method fits for the purpose of CONAMA 357 regulation for drinking water quality in the aforementioned contaminated area. Approximately 150 firings can be done with a single tungsten coil atomizer by using 20 \'mü\'l sample volume
6

Desenvolvimento de métodos analíticos empregando à espectrometria de emissão óptica para avaliação dos níveis de contaminantes elementares em amostras de diversas origens / Development of analytical methods employing optical emission spectrometry to evaluate the level of elemental contaminants in samples of different origins

Gonçalves, Daniel Araujo [UNESP] 08 July 2016 (has links)
Submitted by Daniel Araujo Gonçalves null (daniel.araujogoncalves@gmail.com) on 2016-08-01T13:43:54Z No. of bitstreams: 1 Goncalves_Tese_versão_final.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-02T19:00:04Z (GMT) No. of bitstreams: 1 goncalves_da_dr_ilha.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5) / Made available in DSpace on 2016-08-02T19:00:04Z (GMT). No. of bitstreams: 1 goncalves_da_dr_ilha.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5) Previous issue date: 2016-07-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho foram desenvolvidos quatro métodos analíticos visando a determinação de elementos químicos em diversas amostras. O primeiro estudo consistiu na determinação de Cr e Mn em placentônios provenientes de bovinos por espectrometria de emissão atômica em filamento de tungstênio (WC AES). O tempo de integração de sinal para 30 ms, proporcionou LOD 45 vezes menor para Mn e 150 vezes menor para Cr com relação a 500 ms. Testes de adição e recuperação apresentaram desvio padrão (SD) de ± 0,02 mg L-1 e recuperações de 91 a 102%. No segundo foram realizadas quantificações de Cr em cápsulas medicinais produzidas na China, a WC AES. A faixa linear de trabalho para determinação de Cr por WC AES foi de 10-100 μg L-1. Os limites de detecção foram de 3 μg L-1, o que possibilitou determinações em um nível 28 vezes menor que o valor máximo de Cr recomendado em medicamentos pela Farmacopeia Americana (USP). A precisão (% RSD) foi calculada na faixa de 5,2 – 7,4% e não foram significativamente diferentes através da aplicação de um teste ANOVA fator único a nível de confiança de 95% (p > 0,05) quando comparados com a técnica de Espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). No terceiro estudo, um Espectrometro de Emissão Óptica com plasma induzido por micro-ondas – MIP OES (MP-AES, Agilent 4200), foi usado em combinação com o método de análise por diluição de padrão (SDA) para determinar Al, Cr, Co, Cu, Fe, Mn, Ni e Zn em amostras de café, chá verde, energético, cerveja, whiskey e cachaça. Não foi necessária preparação da amostra, a não ser uma simples diluição em HNO3 1% v v-1. A eficiência do SDA foi avaliada por experimentos de adição e recuperação e os resultados foram comparados com os métodos tradicionais de calibração externa (EC), o padrão interno (IS) e adição de padrão (AS). As recuperações médias por SDA para vários elementos avaliadas neste trabalho foram entre 90 e 99%. Para o método tradicional de adições padrão, por exemplo, as recuperações médias entre 101 e 122% foram obtidos para os mesmos analitos e amostras. No quarto estudo um MIP OES (MP-AES, Agilent 4200) foi utilizado para a determinação de Cd, Cr, Cu, Ni e Pb na matriz de óleo fusel onde emprega-se a calibração externa preparada em solução de 1% HNO3 e 1-propanol. Soluções contendo 5 e 50% da matriz v v-1 foram diluidas em 1-propanol e solução de óleo fúsel puro foram analisados. Não foram observados efeitos de matriz quando empregou-se a calibração com soluções de 1-propanol mesmo para determinações na amostra não diluída, com recuperações entre 90-109%. Os LODs para Cd, Cr, Cu, Ni e Pb em 1-propanol foram de 0,03; 0,009; 0,01; 0,007 e 0,04 mg L-1, respectivamente. O procedimento descrito para o MIP OES é uma abordagem simples, exata e precisa para rastrear análise de elementos de óleo fúsel. / In this work were developed four analytical methods for the determination of chemical elements in several samples. The first study consisted in determination of Cr and Mn in placenton from bovine animals by Atomic emission spectrometry in tungsten filament (WC AES). Signal integration time for 30 ms, provided LOD 45 times lower for Mn and 150 times lower for Cr with respect to 500 ms. Addition and recovery tests presented standard deviation (SD) of ± 0,02 mg L-1 and recoveries of 91 to 102%. In the second were carried out baseline measurements of Cr in medicinal capsule produced in China by WC AES. The linear range for determination of Cr by WC AES was 10 - 100 μg L-1 . The limits of detection were 3 μg L-1 , which allowed determinations in a level 28 times smaller than the maximum value of Cr recommended medicines for the U.S. Pharmacopeial Convention (USP). The precision (% RSD) was estimated in the range of 5,2 – 7,4% and were not significantly different by applying a test ANOVA single factor at the level of confidence 95% (p > 0,05) when compared with Optical emission spectrometry with inductively coupled plasma (ICP OES). In the third study, a Spectrometer of Optical Emission plasma induced by microwave – MIP OES (MP-AES, Agilent 4200), was used in combination with the method of analysis for standard dilution (SDA) to determine Al, Cr, Co, Cu, Fe, Mn, Ni e Zn in samples of coffee, green tea, energetic, beer, whiskey and cachaça brazilian. It didn't require sample preparation except a simple dilution in HNO3 1% v v-1 . The efficiency of the SDA was evaluated by experiments of addition and recovery, and the results were compared with the traditional methods of external calibration (EC), the internal standard (IS) and addition of default (AS). Average recoveries for SDA to various elements evaluated in this study were between 90 and 99%. For the traditional method of standard additions, for example, the average recoveries between 101 and 122% were obtained for the same analytes and samples. In the fourth study a MIP OES (MP-AES, Agilent 4200), was used for the determination of Cd, Cr, Cu, Ni e Pb in the array of fusel oil where is used the external calibration solution prepared 1% HNO3 and1-propanol. Solutions containing 5 and 50% of the matrix v v-1 were dissolved in 1-propanol and fusel oil pure solution were analyzed. Matrix effects were not observed when it was calibration with 1-propanol solutions even for undiluted sample determinations, with recoveries between 90 - 109%. The LODs for Cd, Cr, Cu, Ni and Pb in 1-propanol were of 0,03; 0,009; 0,01; 0,007 and 0,04 mg L-1 , respectively. The procedure described for MIP OES is a simple, accurate and precise approach to trace elements analysis of fusel oil. / CAPES PDSE: 99999.002566/ 2014-01
7

Desenvolvimento de métodos analíticos empregando à espectrometria de emissão óptica para avaliação dos níveis de contaminantes elementares em amostras de diversas origens /

Gonçalves, Daniel Araujo. January 2016 (has links)
Orientador: Mirian Cristina dos Santos / Resumo: Neste trabalho foram desenvolvidos quatro métodos analíticos visando a determinação de elementos químicos em diversas amostras. O primeiro estudo consistiu na determinação de Cr e Mn em placentônios provenientes de bovinos por espectrometria de emissão atômica em filamento de tungstênio (WC AES). O tempo de integração de sinal para 30 ms, proporcionou LOD 45 vezes menor para Mn e 150 vezes menor para Cr com relação a 500 ms. Testes de adição e recuperação apresentaram desvio padrão (SD) de ± 0,02 mg L-1 e recuperações de 91 a 102%. No segundo foram realizadas quantificações de Cr em cápsulas medicinais produzidas na China, a WC AES. A faixa linear de trabalho para determinação de Cr por WC AES foi de 10-100 μg L-1. Os limites de detecção foram de 3 μg L-1, o que possibilitou determinações em um nível 28 vezes menor que o valor máximo de Cr recomendado em medicamentos pela Farmacopeia Americana (USP). A precisão (% RSD) foi calculada na faixa de 5,2 – 7,4% e não foram significativamente diferentes através da aplicação de um teste ANOVA fator único a nível de confiança de 95% (p > 0,05) quando comparados com a técnica de Espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). No terceiro estudo, um Espectrometro de Emissão Óptica com plasma induzido por micro-ondas – MIP OES (MP-AES, Agilent 4200), foi usado em combinação com o método de análise por diluição de padrão (SDA) para determinar Al, Cr, Co, Cu, Fe, Mn, Ni e Zn em amostras de café, chá verde, ene... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work were developed four analytical methods for the determination of chemical elements in several samples. The first study consisted in determination of Cr and Mn in placenton from bovine animals by Atomic emission spectrometry in tungsten filament (WC AES). Signal integration time for 30 ms, provided LOD 45 times lower for Mn and 150 times lower for Cr with respect to 500 ms. Addition and recovery tests presented standard deviation (SD) of ± 0,02 mg L-1 and recoveries of 91 to 102%. In the second were carried out baseline measurements of Cr in medicinal capsule produced in China by WC AES. The linear range for determination of Cr by WC AES was 10 - 100 μg L-1 . The limits of detection were 3 μg L-1 , which allowed determinations in a level 28 times smaller than the maximum value of Cr recommended medicines for the U.S. Pharmacopeial Convention (USP). The precision (% RSD) was estimated in the range of 5,2 – 7,4% and were not significantly different by applying a test ANOVA single factor at the level of confidence 95% (p > 0,05) when compared with Optical emission spectrometry with inductively coupled plasma (ICP OES). In the third study, a Spectrometer of Optical Emission plasma induced by microwave – MIP OES (MP-AES, Agilent 4200), was used in combination with the method of analysis for standard dilution (SDA) to determine Al, Cr, Co, Cu, Fe, Mn, Ni e Zn in samples of coffee, green tea, energetic, beer, whiskey and cachaça brazilian. It didn't require sample prepara... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0844 seconds