• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 3
  • 1
  • 1
  • Tagged with
  • 17
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Approche probabiliste de la durée de vie des structures sollicités en fatigue thermique

Guédé, Zakoua Lemaire, Maurice. January 2009 (has links)
Reproduction de : Thèse de doctorat : Génie Mécanique : Clermont-Ferrand 2 : 2005. / Thèse avec annexes. Titre provenant de l'écran-titre. Bibliogr. p. 135-139.
2

Etude des défauts présents dans des tuyaux soumis à une pression interne

Moustabchir, Hassane Azari, Zitouni. January 2008 (has links) (PDF)
Thèse de doctorat : Sciences de l'ingénieur : génie mécanique : Metz : 2008. / Thèse soutenue sur ensemble de travaux. Bibliogr. p. 37-42, 86, 128-129.
3

Die Mannesmannröhren-Werke 1888 bis 1920 : Organisation und Unternehmensführung unter der Gründerfamilie, Bankiers und Managern /

Dietrich, Yorck. January 1991 (has links)
Texte remanié de: Magisterarbeit--Philosophische Fakultät--Bonn--Rheinische Friedrich-Wilhelms-Universität, 1989. / Bibliogr. p. 176-180. Index.
4

Simulation de la formation d'un dépôt de particules en microfiltration effets des conditions hydrodynamiques et des interactions physicochimiques sur la morphologie et la perméabilité apparente du dépôt /

Gassara, Dorra Schmitz, Philippe. Ayadi, Adbel-moneim. January 2008 (has links)
Reproduction de : Thèse de doctorat : Dynamique des fluides : Toulouse, INPT : 2007. Reproduction de : Thèse de doctorat : Dynamique des fluides : Sfax (Tunisie), ENIS : 2007. / Thèse soutenue en co-tutelle. Titre provenant de l'écran-titre. Bibliogr. 106 réf.
5

Modélisation statistique de la prévision des défaillances sur les conduites d'eau potable /

Eisenbeis, Patrick. January 1995 (has links)
Th. doct.--Génie de l'environnement--Strasbourg 1, 1994. / Bibliogr. p. 187-190. Résumé en anglais et en français.
6

Buoyant miscible displacement flows of Newtonian and non-Newtonian fluids : stationary and oscillating geometries

Amiri, Amin 18 October 2019 (has links)
Cette thèse vise l’étude des écoulement de déplacement de fluides miscibles à l’intérieur d’un long tuyau stationnaire vertical et d’un tuyau en mouvement. Concernant la géométrie des mouvements, le tuyau oscille comme un pendule inversé avec une fréquence maximale faible, c’est-à-dire, ˆf= 0.2(Hz) et une oscillation maximale de faible amplitude, soit 15 (◦) par rapport à l’axe du tuyau. Les écoulement de déplacement se produisent à un nombre de Péclet élevé et aux petits nombres d’Atwood. L’accent est mis sur les types de fluides et de géométries (tuyau fixe ou en mouvement). Les approches expérimentales détaillées sont utilisées de manière intégrée. Dans cette thèse, la configuration de densité est la densité instable. La majeure partie des travaux en cours se concentre sur les écoulements de déplacement de fluides Newtoniens isovisqueux, mais nous étudions également l’écoulement de déplacement à contrainte au seuil de plasticité dans un long tuyau vertical. Pour un écoulement de déplacement Newtonien isovisqueux dans un tuyau stationnaire, nous remarquons un effet stabilisant imposé au débit principal et signalant l’existence de deux régimes d’écoulement principaux à long moment introduits par un écoulement de déplacement stable et un écoulement de déplacement instable. La transition entre ces deux régimes se produit à un nombre critique de Reynolds modifié (Ret / This thesis aims to investigate buoyant displacement flows of miscible fluids in a long, vertical stationary pipe or a moving pipe. For the case of the moving geometry, the pipe oscillates like an inverted pendulum with a small maximum frequency, i.e.ˆf= 0.2(Hz) and a small maximum oscillation amplitude, i.e. 15 (◦) with respect to the pipe axis. The displacement flows occur at the high Péclet number and small Atwood numbers. The focus is on the type of fluids and geometries (stationary or moving pipe). Detailed experimental approaches are employed in an integrated fashion. The density configuration in this thesis is the density unstable. The main part of the current work is concentrated on displacement flows of iso-viscous Newtonian fluids. We also study the yield stress displacement flow in a long vertical pipe. For iso-viscous Newtonian displacement flow in a stationary pipe, we uncover the stabilizing effect of the mean imposed flow and report the existence of two main flow regimes at long times introduced as a stable displacement flow and an unstable displacement flow. The transition between these two regimes occurs at a critical modified Reynolds number (Ret
7

Formation et organisation de biofilms en milieu eau potable : Influence du gradient de vitesse pariétal / Formation and organization of drinking water biofilms : Influence of the wall shear rate

Paris, Tony 07 April 2008 (has links)
Une grande partie de la flore microbienne des réseaux de distribution d’eau potable est située au niveau des parois des canalisations. Ce biofilm, génère un certain nombre de problèmes pour la gestion des réseaux tels que la consommation du désinfectant, la croissance bactérienne ou encore l’incorporation de pathogènes qui peuvent conduire au non-respect des critères de qualité des eaux par le relargage d’une partie de sa biomasse dans la masse d’eau. Différents paramètres, parmi lesquels le régime hydraulique, permettent de contrôler la prolifération du biofilm. Nous avons cherché à savoir quel était le paramètre clé liant l’hydrodynamique et les biofilms. En utilisant des réacteurs de Couette-Poiseuille dont la géométrie permet de faire varier indépendamment le gradient de vitesse pariétal (?) et le débit, nous avons montré que le gradient de vitesse pariétal est bien le paramètre important pour le contrôle des biofilms. En utilisant ce résultat, nous avons mis au point un modèle de diffusion-convective permettant de décrire le transport et l’accumulation des bactéries sur la surface. Nous avons ainsi mis en évidence que l’accumulation du biofilm est fonction de ?1/3*t. L’hydrodynamique affectant l’organisation de la biomasse, nous avons quantifié par analyse d’images, l’impact du gradient de vitesse pariétal sur la taille, la forme et l’orientation des éléments du biofilms. Les phénomènes de relargage ont été étudiés par le biais d’inoculation de particules de polystyrène et E. coli dans des biofilms formés en chambres d’écoulement ainsi que par la réalisation d’à-coups hydrauliques dans un écoulement en conduite. / Most of the microbial flora present in the drinking water distribution network is located on the pipe walls. This biofilm is a major concern for drinking water providers as it increases disinfectant decay, provides a shelter for pathogens and is the main site of bacterial growth, thus leading, through bacterial detachment, to the non-respect of drinking water quality criteria. Hydraulic regime is one among several parameters that can be used to control biofilm proliferation. Our first objective was to determine which was the key parameter in the hydraulic regime that was controlling biofilm accumulation. Using Couette-Poiseuille reactors which geometry allow to vary independently wall shear rate (?) an d flow rate, we showed that the wall shear rate was indeed the important parameter for biofilm control. From this result, we built a convective-diffusion model in order to describe bacterial transport and accumulation to the pipe surface. It appeared that biofilm accumulation was a function of ?1/3*t. As hydraulic regime was known to affect biofilm organization, we quantified through image analysis, the effect of wall shear rate, on size, shape and orientation of the biofilm elements. Biofilm stability was studied by inoculations of polystyrene microspheres and E. coli in flow chambers colonized by biofilms. The consequences of the rapid variation of the flow rate on a biofilm formed in a pipe flow were also studied.
8

Réhabilitation des réseaux d'eau potable méthodologie d'analyse multicritère de spatrimoines et des programmes de réhabilitation /

Haidar, Hatem Le Gauffre, Pascal January 2007 (has links)
Thèse doctorat : Génie Civil Urbain : Villeurbanne, INSA : 2006. / Titre provenant de l'écran-titre. Bibliogr. p. 166-178.
9

Contribuții teoretice și experimentale privind utilizarea materialelor textile pentru izolarea termică a conductelor ce transportă apa caldă / Contributions théoriques et expérimentales concernant l'utilisation des matériaux textiles dans l'isolation thermique des conduits qui transportent de l'eau chaude. / Theoretical and experimental research on the use of textile materials for thermal insulation of the pipes carrying hot water

Horga, Gheorghe 26 November 2013 (has links)
La thèse vise à identifier, développer et tester des matériaux isolants à partir de déchets textiles, le rôle de l'isolation thermique des tuyaux. Visant à accroître la performance énergétique de chauffage et avec un impact environnemental réduit. Etude théorique était d'identifier les propriétés matériau d'isolation thermique, la classification sur le marché utilisé dans l'isolation thermique des méthodes de test national et international. Pour tester les propriétes thermiques ont été menées deux installations de laboratoire. Dans un premier temps l'installation, afin de déterminer la conductivité thermique, le flux thermique de la chaleur est produite par une résistance électrique. Ont été réalisés et testés structurellement différents des matériaux de densité (coton, la laine et le tissu non tissé) de la température maximale de 90C dans la canalisation. Le rôle de ces essais était de déterminer la densité et le comportement optimal à des températures différentes. Une deuxième installation est effectuée sur un cas réel (une tuyauterie isolée thermique avec a) la flux thermique de la chaleur est générée par le fluide (de l'eau). Un conducteur testé dans trois situations : tuyaux non isolés, tuyau isolé et le tuyau PUR isolé non tissé. Tous les tests étaient en faveur de la non tissé. L'analyse statistique a montré que la température et la densité sont des facteurs importants qui influent sur la conductibilité thermique des tissus. / The thesis aims at identifying, developing and testing of insulation materials from waste textiles, the role in thermal insulation of pipes. Aiming at increasing the energy performance of heating and with a reduced environmental impact. Theoretical study was to identify thermal insulating material properties, classification on the market used in thermal insulation of national and international and the testing methods. To test the thermal properties were conducted two laboratory facilities. At first installation, to determine the thermal conductivity, the thermal flow of heat flux is generated by electrical resistance. Were made and tested structurally different density materials (cotton, wool and non-woven fabric) with maximum temperature of 90C in the pipeline. The role of these tests was to identify the optimum density and behavior at different temperatures. A second installation is performed on a real case (an installation with a thermal insulated pipe) the thermal flow of heat is generated by the fluid (water). A conductive tested in three situations: non-insulated pipes, insulated pipe and pipe PUR insulated non-woven fabric. All tests were in favor of non-woven fabric. The statistical analysis showed that the temperature and density are significant factors that influence the thermal conductivity of fabrics.
10

Investigation of the 3D flow characteristics in a rotating channel setup

Torriano, Federico 11 April 2018 (has links)
Tableau d'honneur de la Faculté des études supérieures et postdoctorales, 2006-2007 / L'objectif de ce projet de maîtrise est de contribuer à une meilleure compréhension des écoulements dans les conduits rectangulaires en rotation. Une attention particulière est apportée aux effets de bout et au développement de l'écoulement. Des simulations RANS en régime stationnaire ont démontré que la présence d'un écoulement secondaire de faible intensité est suffisante pour modifier le profil de vitesse axiale de façon à que ce dernier diffère significativement de la solution théorique 2D. En conséquence, les comparaisons entre les résultats expérimentaux et les simulations numériques 2D devraient être faites avec prudence. Les calculs stationnaires ont également montré que le développement de l'écoulement dans un canal tournant est affecté par l'apparition de cellules de type Taylor-Görtler le long du mur pression. Puisque ces tourbillons sont légèrement inclinés par rapport au plan horizontal, une solution stationnaire pleinement développée n'est jamais atteinte. Des simulations subséquentes en régime instationnaire dans un domaine périodique ont prouvé qu'une solution pleinement développée peut cependant exister dans un canal tournant, mais l'écoulement est alors formellement instationnaire car les cellules longitudinales sont convectées vers les bouts de la conduite par l'action de l'écoulement secondaire. / The objective of the present work is to provide a basic description and to contribute toward a better understanding of rotating high aspect ratio duct flows. Particular attention is given to end-wall effects and flow development. Steady RANS simulations have shown that the presence of a weak, but unavoidable, end-wall generated secondary flow produces sufficient transverse advection to alter the streamwise velocity profile in such a way that it differs noticeably from the theoretical 2D channel case. Thus, comparisons between experimental results and 2D numerical simulations should be performed very cautiously. Steady state calculations have also revealed that the flow development in a rotating duct is subtly affected by the appearance of longitudinal Taylor-Görtler type cells near the pressure wall. Since the roll cells are tilted toward the end-wall, no steady fully developed solution is ever reached. Subsequent unsteady flow calculation in a streamwise periodic domain have shown that a fully developed solution can exist in a rotating duct, but the resulting flow field is formally unsteady due to the convection of the roll cells toward the end-wall.

Page generated in 0.0377 seconds