• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 156
  • 2
  • Tagged with
  • 158
  • 77
  • 48
  • 26
  • 24
  • 24
  • 23
  • 21
  • 20
  • 20
  • 19
  • 17
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

EFICIÊNCIA DE UM SISTEMA DE DESSALINIZAÇÃO DE ÁGUA SALOBRA UTILIZANDO ULTRAFILTRAÇÃO E OSMOSE REVERSA

Almeida, Juliano Penteado de 20 April 2017 (has links)
Made available in DSpace on 2017-07-20T13:42:00Z (GMT). No. of bitstreams: 1 Juliano Almeida.pdf: 2689795 bytes, checksum: e2c63ba0cfcdfb76d39a3d5e44e5dcf9 (MD5) Previous issue date: 2017-04-20 / Considering the shortage of fresh water availability and an increased demand for water in the world, including Brazil, one of the alternatives for water supply are the water desalination system, which remove salts from brackish or seawater. The objective of this study was to evaluate the efficiency of treated water desalination system with production capacity of 1.0 m3 h-1 of treated water, installed in a water treatment plant of Sanepar (Water and Sanitation Company of the State of Parana), in Praia de Leste located in the coast of the state of Paraná, Brazil. In this study, the seawater was diluted with fresh water to make brackish water. The brackish water was prepared from the water mixture of the Pombas River, source of fresh water supply to the region, and sea water. The mixtures were performed to obtain concentrations of 1000 and 1500 mg L-1 of total dissolved solids (TDS). The system was composed of ultrafiltration (UF) as a pre-treatment to reverse osmosis (RO). Experiments were performed during 15 days for each TDS concentration of brackish water and TDS removal efficiencies were 99.0 and 99.1%, respectively. Besides TDS, other water quality parameters such as: electrical conductivity, turbidity, apparent colour, alkalinity, total hardness, calcium, magnesium, chlorides, sulphates and pH were monitored. Oxidation-reduction potential (ORP) and osmotic pressure, filtration rate and membrane recovery rate were also measured for the RO. The pilot plant system could remove all water quality parameters studied. / Com a escassez da disponibilidade de água doce e o aumento da demanda de água no mundo e também no Brasil, uma das alternativas para o suprimento de água são os sistemas de dessalinização de água, que removem os sais da água salobra ou salgada. Este trabalho teve como objetivo avaliar a eficiência de um sistema piloto de dessalinização de água salobra com capacidade de produção de 1,0 m3 h-1 de água tratada, instalado na estação de tratamento de água (ETA) da Sanepar, no balneário de Praia de Leste, no litoral do estado do Paraná. A água salobra foi preparada a partir da mistura da água bruta do Rio das Pombas, manancial que abastece o balneário, e água do mar. As misturas foram realizadas até obter concentrações de 1000 e 1500 ± 100 mg L-1 de sólidos dissolvidos totais (SDT). O sistema foi composto de ultrafiltração como pré-tratamento à osmose reversa. Os experimentos foram realizados durante o período de 15 dias para cada concentração de SDT da água salobra obtendo-se remoções de 99,0 e 99,1%, para 1500 ± 100 mg L-1 e 1000 ± 100 mg L-1, respectivamente. Além dos SDT, foram avaliados outros parâmetros de qualidade da água como: condutividade elétrica, turbidez, cor aparente, alcalinidade, dureza total, cálcio, magnésio, cloretos, sulfatos, pH e temperatura. Durante os experimentos foram avaliados potencial de oxirredução (ORP) e a pressão osmótica, a taxa de filtração e a taxa de recuperação na membrana de osmose reversa. O sistema de ultrafiltração foi mais eficiente na remoção de turbidez e cor aparente, sendo que o sistema de osmose reversa apresentou melhor eficiência na remoção de sólidos dissolvidos totais.
142

Influência das substâncias húmicas de diferentes massas molares na coagulação, floculação e sedimentação no tratamento de água / Influence of different molecular weight of humic substances in the coagulation, flocculation and sedimentation in water treatment

Campos, Sandro Xavier de 10 December 2004 (has links)
Neste trabalho estudou-se a influência das substâncias húmicas (SH) extraídas de turfa, com diferentes massas molares, utilizadas para a preparação de águas com cor de 100 uH ± 5 uH, nos ensaios de coagulação, floculação e sedimentação no tratamento de água. Foram realizadas caracterizações das SH por meio das técnicas de ultrafiltração (UF), análise elementar (AE), ultravioleta/visível (UV/Vis), infravermelho (IF), ressonância magnética nuclear de C13 (RMN de C13), ressonância paramagnética eletrônica (EPR). Essas caracterizações demonstraram que as frações de menor massa molar (30 - 100 kDa e <30 kDa), obtidas por UF, apresentaram uma maior concentração de grupos contendo oxigênio, enquanto que a fração de maior massa molar (>100 kDa) e a contendo todas as massas molares juntas (filtrada apenas em membrana com tamanho de poro de 0,45 &#956m) apresentaram maior concentração de grupamentos aromáticos. Verificou-se também que nas frações de menor massa molar (30 - 100 kDa e <30 kDa) a porcentagem de ácidos fúlvicos é maior do que a de ácidos húmicos. Nas frações de maior massa molar (> 100kDa e filtrada em membrana com tamanho de poro de 0,45 &#956m) ocorreu o contrário. Os ensaios de coagulação, floculação e sedimentação realizados com águas preparadas com as diferentes frações de diferentes massas molares, mostraram que quanto maior a massa molar, maior é a facilidade de coagulação, floculação e sedimentação, o que proporciona maior eficiência na remoção da cor aparente. Os diagramas de coagulação obtidos para o coagulante sulfato de alumínio (Al2(SO4)3 . 14,3 H2O) mostraram que independente da massa molar, a região de pH ótimo de coagulação esteve entre 6 e 7, sendo que a remoção da cor aparente foi crescente com a diminuição da velocidade de sedimentação (Vs= 3,0, 1,5 e 0,5 cm/min). Com a diminuição da massa molar houve um aumento na dosagem de Al2(SO4)3 . 14,3 H2O necessária para se obter curvas de remoção da cor aparente iguais às obtidas com a água preparada com a fração de maior massa molar (> 100 kDa). Os ensaios de coagulação, floculação, sedimentação e filtração demonstraram boa reprodutibilidade em relação aos resultados de remoção de cor aparente obtidos para a confecção dos diagramas de coagulação. Após a filtração foi verificado que os valores da cor aparente não foram detectados pela técnica de medição da cor utilizada, para todas as águas de estudo, com exceção da água preparada com a fração de menor massa molar (<30 kDa). Conclui-se que, quanto menor a massa molar, maior a porcentagem de ácidos fúlvicos presentes e maior a concentração de grupamentos com oxigênio ligado. Assim, será necessária uma maior dosagem de coagulante Al2(SO4)3 . 14,3 H2O para que ocorra uma remoção eficiente da cor. / The present thesis deals with the influence of humic substances (HS) on coagulation, flocculation and sedimentation tests for water treatment. These substances were extracted from peat, had different molecular weight and were used for the preparation of water with 100 ± 5 uH color. Characterizations of HS were performed by the following techniques ultra filtration (UF), elemental analysis (EA), ultraviolet/ visible (UV/Vis), infrared (IF), C13 nuclear magnetic resonance (NMR of C13) and electron paramagnetic resonance (EPR). Such characterizations showed that fractions of smaller molecular weight (30 - 100 kDa and < 30 kDa) obtained by UF presented a higher concentration of groups containing oxygen, while the fraction with the largest molecular weight (>100 kDa) and the one containing all the molecular weight together (filtered only in membrane with pore size of 0,45 &#956m) presented a higher concentration of aromatic groupings. It was also possible to verify that in the fractions with smaller molecular weight (30 - 100 kDa e <30 kDa) the percentage of fulvic acids was higher than the one of humic acids . However the opposite occurred of larger molecular weight (>100 kDa and filtered in membrane with pore size of 0,45 &#956m). The tests of coagulation, flocculation and sedimentation conducted with waters prepared with different fractions of different molecular weight showed that the larger the molecular weight, the easier the coagulation, flocculation and sedimentation, resulting in higher efficiency in the removal of the apparent color. The coagulation diagrams obtained for aluminum sulphate (Al2(SO4)3 .14,3 H2O) showed that independently of the molecular weight, the region with optimum pH for coagulation was between 6 and 7 and the removal of the apparent color increased with the decrease in the sedimentation velocity (Vs= 3,0, 1,5 e 0,5 cm/min). Due to the decrease in the molecular weight there was as increase in the dosage of Al2(SO4)3 .14,3 H2O necessary to obtain curves of the removal of the apparent color similar to the ones obtained with the water prepared with the fraction of the largest molecular weight (> 100 kDa). Tests of coagulation, flocculation, sedimentation and filtration showed good reproducibility in relation to the results of removal of apparent color, obtained for the construction of coagulation diagrams. After filtration it was possible to verify that the values of apparent color were not detected by the technique of color measurement utilized for all the waters studied, except for the water prepared with the fraction of the smallest molecular weight (< 30 kDa). It was possible concluded that the smaller the molecular weight, the higher the percentage of present fulvic acids and the higher the concentration of groupings with bond oxygen. Thus a higher dosage of coagulant Al2(SO4)3 .14,3 H2O will be necessary for an efficient removal of color.
143

Synthesis and characterization of polysulfone/nanoclay/polyethylene oxide composite ultrafiltration membranes. / Síntese e caracterização de membranas compósitas de polisulfona para ultrafiltração modificadas com nanoargila e polióxido de etileno.

Raphael Rodrigues 15 December 2015 (has links)
Membrane structure modification is a common approach to enhance membrane properties and performance. For example, the addition of dopants to the membrane casting solution has been observed to increase hydrophilicity, alter surface and internal pore structure, increase thermal and mechanical resistance, and impart anti-fouling properties. In this study, it was evaluated how the addition of individual and simultaneous nanoclay and polyethylene oxide (PEO) dopants affected the structure and performance of polysulfone (PSU) ultrafiltration membranes. Membrane performance was evaluated in the cross-flow configuration. The pure water permeability of the neat PSU membrane was 15 L/m².h.bar and at the optimal dosage of the individually doped membranes was 1.5% weight nanoclay to PSU and 5% weight PEO to PSU resulting in permeability of 56 and 237 L/m².h.bar, respectively. Simultaneous doping using the optimal individual weight percentages had a lower effect resulting in a permeability of 192 L/m².h.bar, in contrast the simultaneous addition of 4.5% nanoclay and 5% PEO had a higher effect resulting in a permeability of 319 L/m².h.bar. The control membrane was compared to the referred membranes and with the 4.5% nanoclay membrane (best permeability only when combined with PEO). These membranes were further examined to determine dopant effects on pore microstructure, superficial charge, separation performance, and fouling susceptibility. In general, doping with nanoclay improved membrane thermal/mechanical resistance and permeability with minimal loss in rejection. Doping with PEO resulted in a greater permeability as compared to nanoclay; however, PEO doping decreased rejection, mechanical resistance, and increased irreversible fouling. Thus, both advantageous and disadvantageous effects should be considered when selecting a dopant to optimize membrane performance. / A modificação da estrutura de membranas é uma abordagem utilizada para melhorar as propriedades de membranas e desempenho de um sistema. Por exemplo, a adição de dopantes na solução de síntese da membrana permite aumentar a hidrofilicidade, alterar a estrutura de poros superficiais e internos e conferir propriedades anti-depósitos. Neste estudo, foi avaliada como a adição de óxido de polietileno e de nano-argila afetam a estrutura e desempenho de membranas de ultrafiltração de polisulfona (PSU). O desempenho da membrana foi avaliado na configuração de fluxo paralelo (cross-flow). A permeabilidade média à água pura da membrana de PSU pura foi de 15 L/m2.h.bar. As dosagem ótimas das membranas dopadas individualmente foram de 1,5% em massa de PSU para nano-argila e 5% em massa de PSU para PEO, resultando em permeabilidades médias de 56 e 237 L/m2.h.bar, respectivamente. A dopagem simultânea usando ambas as percentagens individuais ótimas teve um efeito menor do que o esperado, resultando em uma permeabilidade média de 192 L/m2.h.bar. Em contraste, verificou-se que a adição simultânea de 4,5% de nano-argila combinada com 5% de PEO teve um efeito maior do que o uso isolado dos aditivos, resultando em uma permeabilidade média de 319 L/m2.h.bar. Desta forma, a membrana de controle foi comparada com as referidas membranas e com membranas compostas somente por nano-argila a 4,5. Estas membranas foram ainda examinadas em detalhes para determinar os efeitos dos dopantes na microestrutura dos poros, cargas superficiais, desempenho da separação, sensibilidade à formação de depósitos, rugosidade superficial e propriedades térmicas e mecânicas. Verificou-se que a dopagem com nano-argila melhora a resistência térmica e mecânica e a permeabilidade das membranas, com uma perda mínima na rejeição. A dopagem com PEO resultou em um aumento notável de permeabilidade em comparação com a adição individual de nano-argila. No entanto, a capacidade de rejeição e resistência térmica e mecânica destas membranas diminuem e a formação de depósitos irreversíveis aumenta. Desta forma, avalia-se que para a utilização de mais de um tipo de dopante os efeitos vantajosos e desvantajosos devem ser considerados individualmente e em conjunto no esforço de se otimizar o desempenho de sistemas de membranas.
144

Influência das substâncias húmicas de diferentes massas molares na coagulação, floculação e sedimentação no tratamento de água / Influence of different molecular weight of humic substances in the coagulation, flocculation and sedimentation in water treatment

Sandro Xavier de Campos 10 December 2004 (has links)
Neste trabalho estudou-se a influência das substâncias húmicas (SH) extraídas de turfa, com diferentes massas molares, utilizadas para a preparação de águas com cor de 100 uH ± 5 uH, nos ensaios de coagulação, floculação e sedimentação no tratamento de água. Foram realizadas caracterizações das SH por meio das técnicas de ultrafiltração (UF), análise elementar (AE), ultravioleta/visível (UV/Vis), infravermelho (IF), ressonância magnética nuclear de C13 (RMN de C13), ressonância paramagnética eletrônica (EPR). Essas caracterizações demonstraram que as frações de menor massa molar (30 - 100 kDa e <30 kDa), obtidas por UF, apresentaram uma maior concentração de grupos contendo oxigênio, enquanto que a fração de maior massa molar (>100 kDa) e a contendo todas as massas molares juntas (filtrada apenas em membrana com tamanho de poro de 0,45 &#956m) apresentaram maior concentração de grupamentos aromáticos. Verificou-se também que nas frações de menor massa molar (30 - 100 kDa e <30 kDa) a porcentagem de ácidos fúlvicos é maior do que a de ácidos húmicos. Nas frações de maior massa molar (> 100kDa e filtrada em membrana com tamanho de poro de 0,45 &#956m) ocorreu o contrário. Os ensaios de coagulação, floculação e sedimentação realizados com águas preparadas com as diferentes frações de diferentes massas molares, mostraram que quanto maior a massa molar, maior é a facilidade de coagulação, floculação e sedimentação, o que proporciona maior eficiência na remoção da cor aparente. Os diagramas de coagulação obtidos para o coagulante sulfato de alumínio (Al2(SO4)3 . 14,3 H2O) mostraram que independente da massa molar, a região de pH ótimo de coagulação esteve entre 6 e 7, sendo que a remoção da cor aparente foi crescente com a diminuição da velocidade de sedimentação (Vs= 3,0, 1,5 e 0,5 cm/min). Com a diminuição da massa molar houve um aumento na dosagem de Al2(SO4)3 . 14,3 H2O necessária para se obter curvas de remoção da cor aparente iguais às obtidas com a água preparada com a fração de maior massa molar (> 100 kDa). Os ensaios de coagulação, floculação, sedimentação e filtração demonstraram boa reprodutibilidade em relação aos resultados de remoção de cor aparente obtidos para a confecção dos diagramas de coagulação. Após a filtração foi verificado que os valores da cor aparente não foram detectados pela técnica de medição da cor utilizada, para todas as águas de estudo, com exceção da água preparada com a fração de menor massa molar (<30 kDa). Conclui-se que, quanto menor a massa molar, maior a porcentagem de ácidos fúlvicos presentes e maior a concentração de grupamentos com oxigênio ligado. Assim, será necessária uma maior dosagem de coagulante Al2(SO4)3 . 14,3 H2O para que ocorra uma remoção eficiente da cor. / The present thesis deals with the influence of humic substances (HS) on coagulation, flocculation and sedimentation tests for water treatment. These substances were extracted from peat, had different molecular weight and were used for the preparation of water with 100 ± 5 uH color. Characterizations of HS were performed by the following techniques ultra filtration (UF), elemental analysis (EA), ultraviolet/ visible (UV/Vis), infrared (IF), C13 nuclear magnetic resonance (NMR of C13) and electron paramagnetic resonance (EPR). Such characterizations showed that fractions of smaller molecular weight (30 - 100 kDa and < 30 kDa) obtained by UF presented a higher concentration of groups containing oxygen, while the fraction with the largest molecular weight (>100 kDa) and the one containing all the molecular weight together (filtered only in membrane with pore size of 0,45 &#956m) presented a higher concentration of aromatic groupings. It was also possible to verify that in the fractions with smaller molecular weight (30 - 100 kDa e <30 kDa) the percentage of fulvic acids was higher than the one of humic acids . However the opposite occurred of larger molecular weight (>100 kDa and filtered in membrane with pore size of 0,45 &#956m). The tests of coagulation, flocculation and sedimentation conducted with waters prepared with different fractions of different molecular weight showed that the larger the molecular weight, the easier the coagulation, flocculation and sedimentation, resulting in higher efficiency in the removal of the apparent color. The coagulation diagrams obtained for aluminum sulphate (Al2(SO4)3 .14,3 H2O) showed that independently of the molecular weight, the region with optimum pH for coagulation was between 6 and 7 and the removal of the apparent color increased with the decrease in the sedimentation velocity (Vs= 3,0, 1,5 e 0,5 cm/min). Due to the decrease in the molecular weight there was as increase in the dosage of Al2(SO4)3 .14,3 H2O necessary to obtain curves of the removal of the apparent color similar to the ones obtained with the water prepared with the fraction of the largest molecular weight (> 100 kDa). Tests of coagulation, flocculation, sedimentation and filtration showed good reproducibility in relation to the results of removal of apparent color, obtained for the construction of coagulation diagrams. After filtration it was possible to verify that the values of apparent color were not detected by the technique of color measurement utilized for all the waters studied, except for the water prepared with the fraction of the smallest molecular weight (< 30 kDa). It was possible concluded that the smaller the molecular weight, the higher the percentage of present fulvic acids and the higher the concentration of groupings with bond oxygen. Thus a higher dosage of coagulant Al2(SO4)3 .14,3 H2O will be necessary for an efficient removal of color.
145

Pós-tratamento de efluente têxtil usando coagulação/floculação combinado com processos de separação por membranas

Fortino, Patrícia Carneiro January 2012 (has links)
A indústria têxtil utiliza elevados volumes de água em seus processos, principalmente na etapa de tingimento, em que são utilizadas também quantidades elevadas de corantes e auxiliares têxteis. A presença desses produtos no efluente gera um efeito prejudicial e claramente visível ao ambiente, pois causam alteração nos parâmetros da qualidade da água do corpo receptor. O presente estudo apresenta o pós-tratamento de um efluente têxtil, objetivando o reciclo deste efluente para água de processo de tingimento. Para isso foi utilizada uma combinação de processo físico-químico de coagulação/floculação (CF) e processo de separação por membrana (PSM) de Ultrafiltração (UF) e Osmose Inversa (OI). Os parâmetros analisados antes e após os tratamentos foram: turbidez, condutividade elétrica, demanda química de oxigênio (DQO), carbono orgânico total (COT) e cor. Na etapa de CF foram testados dois tipos de coagulantes, o Sulfato de Alumínio e o Cloreto Férrico, nas concentrações de 30, 50, 70 e 100 mg.L-1. Foram testadas três concentrações de floculante comercial: 0,2, 0,3 e 0,4 mg.L-1. Os experimentos foram conduzidos em pH 7. As etapas de PSM foram conduzidas em módulo plano de Ultrafiltração e em módulos plano e espiral na membrana de Osmose Inversa. O melhor desempenho foi obtido com a dosagem de 50 mg.L-1 do coagulante cloreto férrico e a de 0,3 mg.L-1 de floculante comercial, que apresentou uma redução de 98% na turbidez com relação ao efluente de alimentação. No PSM de Ultrafiltração a remoção de cor não foi satisfatória por ainda apresentar coloração. No PSM de Osmose Inversa com o módulo plano o objetivo da remoção de cor foi atingido com sucesso na análise visual, porém, a vazão de permeado mostrou-se muito baixa inviabilizando o processo. No PSM de Osmose Inversa em módulo espiral a cor foi removida com sucesso, a turbidez ficou abaixo de 1 NTU, a DQO ficou abaixo do limite de detecção do equipamento e a vazão de permeado foi satisfatória. Assim, o estudo aponta como resultado a aplicação CF combinado à OI no tratamento eficaz deste efluente. / The textile industry uses large volumes of water in their processes, especially in the dyeing step, which are also used large quantities of coloring agents and textile auxiliaries. The presence of these products in the effluent generates a harmful effect and clearly visible to the environment because they cause changes in the parameters of the receiving body of water. This paper presents the post-treatment effluent from a textile industry, in order to recycle it as process water for dyeing. A combination of physico-chemical process were carried out applying coagulation / floculation (CF) and Ultrafiltration (UF) membrane separation process (MSP) and reverse osmosis (RO). The parameters analyzed before and after treatments were: turbidity, electrical conductivity, chemical oxygen demand (COD), total organic carbon (TOC) and color. In CF stage two types of coagulants were tested, aluminum sulphate and ferric chloride at concentrations of 30, 50, 70 e 100 mg.L-1. Three concentrations of commercial floculants were evaluated: 0,2, 0,3 e 0,4 mg.L-1. The experiments were conducted at pH 7. MSP steps were conducted in plan Ultrafiltration module, and in the Reverse Osmosis membrane, plan and spiral modules were tested. The best performance was obtained with a dosage of 50 mg.L-1 of the coagulant ferric chloride and 0.3 mg.L-1 commercial flocculant, which showed a 98% reduction in turbidity in respect to the raw effluent. MSP Ultrafiltration color removal was not satisfactory because color was still present. In MSP Reverse Osmosis using the plan module the goal of color removal was successfully achieved in the visual analysis, however, the membrane flow was extremely low compared with the UF permeate flow and prevented the process. The color in MSP Reverse Osmosis spiral module has been successfully removed, the turbidity was below 1 NTU, the COD was below the detection limit of the the equipment and the permeate flow was satisfactory. In this way, the study showed the best application for this effluent is CF combined with RO.
146

Pós-tratamento de efluente têxtil usando coagulação/floculação combinado com processos de separação por membranas

Fortino, Patrícia Carneiro January 2012 (has links)
A indústria têxtil utiliza elevados volumes de água em seus processos, principalmente na etapa de tingimento, em que são utilizadas também quantidades elevadas de corantes e auxiliares têxteis. A presença desses produtos no efluente gera um efeito prejudicial e claramente visível ao ambiente, pois causam alteração nos parâmetros da qualidade da água do corpo receptor. O presente estudo apresenta o pós-tratamento de um efluente têxtil, objetivando o reciclo deste efluente para água de processo de tingimento. Para isso foi utilizada uma combinação de processo físico-químico de coagulação/floculação (CF) e processo de separação por membrana (PSM) de Ultrafiltração (UF) e Osmose Inversa (OI). Os parâmetros analisados antes e após os tratamentos foram: turbidez, condutividade elétrica, demanda química de oxigênio (DQO), carbono orgânico total (COT) e cor. Na etapa de CF foram testados dois tipos de coagulantes, o Sulfato de Alumínio e o Cloreto Férrico, nas concentrações de 30, 50, 70 e 100 mg.L-1. Foram testadas três concentrações de floculante comercial: 0,2, 0,3 e 0,4 mg.L-1. Os experimentos foram conduzidos em pH 7. As etapas de PSM foram conduzidas em módulo plano de Ultrafiltração e em módulos plano e espiral na membrana de Osmose Inversa. O melhor desempenho foi obtido com a dosagem de 50 mg.L-1 do coagulante cloreto férrico e a de 0,3 mg.L-1 de floculante comercial, que apresentou uma redução de 98% na turbidez com relação ao efluente de alimentação. No PSM de Ultrafiltração a remoção de cor não foi satisfatória por ainda apresentar coloração. No PSM de Osmose Inversa com o módulo plano o objetivo da remoção de cor foi atingido com sucesso na análise visual, porém, a vazão de permeado mostrou-se muito baixa inviabilizando o processo. No PSM de Osmose Inversa em módulo espiral a cor foi removida com sucesso, a turbidez ficou abaixo de 1 NTU, a DQO ficou abaixo do limite de detecção do equipamento e a vazão de permeado foi satisfatória. Assim, o estudo aponta como resultado a aplicação CF combinado à OI no tratamento eficaz deste efluente. / The textile industry uses large volumes of water in their processes, especially in the dyeing step, which are also used large quantities of coloring agents and textile auxiliaries. The presence of these products in the effluent generates a harmful effect and clearly visible to the environment because they cause changes in the parameters of the receiving body of water. This paper presents the post-treatment effluent from a textile industry, in order to recycle it as process water for dyeing. A combination of physico-chemical process were carried out applying coagulation / floculation (CF) and Ultrafiltration (UF) membrane separation process (MSP) and reverse osmosis (RO). The parameters analyzed before and after treatments were: turbidity, electrical conductivity, chemical oxygen demand (COD), total organic carbon (TOC) and color. In CF stage two types of coagulants were tested, aluminum sulphate and ferric chloride at concentrations of 30, 50, 70 e 100 mg.L-1. Three concentrations of commercial floculants were evaluated: 0,2, 0,3 e 0,4 mg.L-1. The experiments were conducted at pH 7. MSP steps were conducted in plan Ultrafiltration module, and in the Reverse Osmosis membrane, plan and spiral modules were tested. The best performance was obtained with a dosage of 50 mg.L-1 of the coagulant ferric chloride and 0.3 mg.L-1 commercial flocculant, which showed a 98% reduction in turbidity in respect to the raw effluent. MSP Ultrafiltration color removal was not satisfactory because color was still present. In MSP Reverse Osmosis using the plan module the goal of color removal was successfully achieved in the visual analysis, however, the membrane flow was extremely low compared with the UF permeate flow and prevented the process. The color in MSP Reverse Osmosis spiral module has been successfully removed, the turbidity was below 1 NTU, the COD was below the detection limit of the the equipment and the permeate flow was satisfactory. In this way, the study showed the best application for this effluent is CF combined with RO.
147

Pós-tratamento de efluente têxtil usando coagulação/floculação combinado com processos de separação por membranas

Fortino, Patrícia Carneiro January 2012 (has links)
A indústria têxtil utiliza elevados volumes de água em seus processos, principalmente na etapa de tingimento, em que são utilizadas também quantidades elevadas de corantes e auxiliares têxteis. A presença desses produtos no efluente gera um efeito prejudicial e claramente visível ao ambiente, pois causam alteração nos parâmetros da qualidade da água do corpo receptor. O presente estudo apresenta o pós-tratamento de um efluente têxtil, objetivando o reciclo deste efluente para água de processo de tingimento. Para isso foi utilizada uma combinação de processo físico-químico de coagulação/floculação (CF) e processo de separação por membrana (PSM) de Ultrafiltração (UF) e Osmose Inversa (OI). Os parâmetros analisados antes e após os tratamentos foram: turbidez, condutividade elétrica, demanda química de oxigênio (DQO), carbono orgânico total (COT) e cor. Na etapa de CF foram testados dois tipos de coagulantes, o Sulfato de Alumínio e o Cloreto Férrico, nas concentrações de 30, 50, 70 e 100 mg.L-1. Foram testadas três concentrações de floculante comercial: 0,2, 0,3 e 0,4 mg.L-1. Os experimentos foram conduzidos em pH 7. As etapas de PSM foram conduzidas em módulo plano de Ultrafiltração e em módulos plano e espiral na membrana de Osmose Inversa. O melhor desempenho foi obtido com a dosagem de 50 mg.L-1 do coagulante cloreto férrico e a de 0,3 mg.L-1 de floculante comercial, que apresentou uma redução de 98% na turbidez com relação ao efluente de alimentação. No PSM de Ultrafiltração a remoção de cor não foi satisfatória por ainda apresentar coloração. No PSM de Osmose Inversa com o módulo plano o objetivo da remoção de cor foi atingido com sucesso na análise visual, porém, a vazão de permeado mostrou-se muito baixa inviabilizando o processo. No PSM de Osmose Inversa em módulo espiral a cor foi removida com sucesso, a turbidez ficou abaixo de 1 NTU, a DQO ficou abaixo do limite de detecção do equipamento e a vazão de permeado foi satisfatória. Assim, o estudo aponta como resultado a aplicação CF combinado à OI no tratamento eficaz deste efluente. / The textile industry uses large volumes of water in their processes, especially in the dyeing step, which are also used large quantities of coloring agents and textile auxiliaries. The presence of these products in the effluent generates a harmful effect and clearly visible to the environment because they cause changes in the parameters of the receiving body of water. This paper presents the post-treatment effluent from a textile industry, in order to recycle it as process water for dyeing. A combination of physico-chemical process were carried out applying coagulation / floculation (CF) and Ultrafiltration (UF) membrane separation process (MSP) and reverse osmosis (RO). The parameters analyzed before and after treatments were: turbidity, electrical conductivity, chemical oxygen demand (COD), total organic carbon (TOC) and color. In CF stage two types of coagulants were tested, aluminum sulphate and ferric chloride at concentrations of 30, 50, 70 e 100 mg.L-1. Three concentrations of commercial floculants were evaluated: 0,2, 0,3 e 0,4 mg.L-1. The experiments were conducted at pH 7. MSP steps were conducted in plan Ultrafiltration module, and in the Reverse Osmosis membrane, plan and spiral modules were tested. The best performance was obtained with a dosage of 50 mg.L-1 of the coagulant ferric chloride and 0.3 mg.L-1 commercial flocculant, which showed a 98% reduction in turbidity in respect to the raw effluent. MSP Ultrafiltration color removal was not satisfactory because color was still present. In MSP Reverse Osmosis using the plan module the goal of color removal was successfully achieved in the visual analysis, however, the membrane flow was extremely low compared with the UF permeate flow and prevented the process. The color in MSP Reverse Osmosis spiral module has been successfully removed, the turbidity was below 1 NTU, the COD was below the detection limit of the the equipment and the permeate flow was satisfactory. In this way, the study showed the best application for this effluent is CF combined with RO.
148

Influencia da ultrafiltração intra-operatoria na retirada de interleucinas, fator de necrose tumoral-alfa e na função pulmonar em pacientes submetidos a revascularização do miocardio com circulação extracorporea / Influence of intra-operative ultrafiltration on the seric interleukins, tumor necrosis factor alpha and pulmonary function in patients submitted myocardial revascularization with cardiopulmonary by pass

Kosour, Carolina 15 August 2018 (has links)
Orientadores: Desanka Dragosavac, Luis Alberto Magna / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-15T12:28:06Z (GMT). No. of bitstreams: 1 Kosour_Carolina_D.pdf: 5835134 bytes, checksum: f6d1efdf0f5f0705f3ba5432ea02cab5 (MD5) Previous issue date: 2010 / Resumo: Introdução: A operação cardíaca com utilização da circulação extracorpórea (CEC) está associada ao desenvolvimento da resposta inflamatória sistêmica e, como conseqüência, à disfunção pulmonar. O uso de ultrafiltração no intra-operatório tem sido proposto para remoção dos mediadores inflamatórios liberados durante a CEC, na tentativa de minimizar a resposta inflamatória. Objetivo: Avaliar o efeito da ultrafiltração nos níveis séricos de interleucinas, fator de necrose tumoral-alfa e na função pulmonar de pacientes submetidos à revascularização do miocárdio. Método: Foi realizado um estudo clínico, prospectivo, randomizado, com 40 pacientes, divididos em dois grupos, em um hospital terciário. Um grupo foi submetido à ultrafiltração (UF) durante a CEC e outro grupo (controle), não. Foram mensurados interleucinas (IL-ip, IL-6, IL-8), fator de necrose tumoral alfa (TNF-a), índices de troca gasosa pulmonar [PaO2/FiO2, D(A-a)O2 e VD/VT] e mecânica ventilatória (Cst e Raw) nos períodos pré-operatório, intra-operatório e dois dias de pós-operatório. As interleucinas e TNF-a foram analisadas também no perfusato, no grupo teste. Resultados: Houve aumento de IL-ip (30 minutos após a CEC e 12 horas após a operação) e IL-6 (24 e 36 horas após a operação) no grupo UF comparado ao grupo controle. Houve aumento de IL-6 em todos os tempos comparados ao tempo inicial, em ambos os grupos. Foi observada diminuição da IL-8 cinco minutos antes da CEC e aumento seis, i2, 24, e 36 horas após operação, além de aumento de TNF-a nos tempos 30 minutos após CEC, 24, 36 e 48 horas após operação. Na análise do líquido ultrafiltrado foi identificada a presença de TNF-a e das demais IL-ip, IL-6, IL-8, somente em traços. Na função pulmonar, houve piora da PaO2/FiO2, D(A-a)O2, VD/VT, cinco minutos antes da CEC, além da diminuição da D(A-a)O2 30 minutos após CEC, seis,i2, 24 e 36 horas após operação. Houve aumento da complacência estática pulmonar (Cst) e queda da resistência de vias aéreas (Raw) cinco minutos antes da CEC, além da queda da Raw seis horas após a operação nos dois grupos. Conclusão: A utilização de ultrafiltração aumentou o nível sérico das IL-i e IL-6, não interferindo na troca gasosa e na mecânica pulmonar de pacientes submetidos à revascularização do miocárdio / Abstract: Introduction: Cardiac surgery with cardiopulmonary bypass (CPB) is associated with the development of systemic inflammatory response and, in consequence, pulmonary dysfunction. The use of ultrafiltration intraoperatively has been proposed to remove inflammatory mediators released during CPB in an attempt to minimize the inflammatory response. Objective: Evaluating the effect of ultrafiltration on the serum levels of interleukin, tumor necrosis factor alpha and pulmonary function in patients undergoing myocardial revascularization. Methods: It was carried out a prospective randomized clinical trial on 40 patients divided into two groups, in a tertiary hospital. One group was submitted to ultrafiltration (UF) during CPB whereas the other group (control), was not. It were mensured interleukins (IL-ip, IL-6, IL-8), tumor necrosis factor alpha (TNF-a), pulmonary gas exchange indexes [PaO2/FiO2, D(A-a)O2 and VD/VT] as well as respiratory mechanics (Cst e Raw) in the preoperative and intraoperative periods and postoperatively. The interleukins and TNF-a were also analyzed in the perfusate in the test group. Results: There was an increase in IL-ip (30 minutes after CPB and 12 hours after surgery) and in IL-6 (24 and 36 hours after surgery) in the UF group by comparison with the control one. There was also an increase in IL-6 at all schedulled times compared to the initial period in both groups. It was noticed a decrease in IL-8 five minutes before CPB and an increase six, i2, 24 and 36 hours after surgery in addition to an increase in TNF- a at the times 30 minutes after CPB, 24, 36 and 48 hours after surgery. On analyzing the ultrafiltrated fluid it was identified the presence of TNF-a and the other IL-ip, IL-6, IL-8 only in traces. Regarding pulmonary function, there was a worsening of PaO2/FiO2, D(A-a)O2, and VD/VT five minutes prior to CPB in addition to a decrease in D(A-a)O2 30 minutes after CPB, six, 12, 24 and 36 hours after surgery. There was an increase in the pulmonary static compliance, and a fall of the airway resistance five minutes before CPB. Also, there was a fall of the airway resistance six hours after surgery in both groups. Conclusion: The use of ultrafiltration has increased the serum levels of IL-1 and IL-6 without interfering with the pulmonary gas exchange and respiratory mechanics in patients undergoing myocardial revascularization / Doutorado / Pesquisa Experimental / Doutor em Cirurgia
149

Aproveitamento de diferentes tipos de soro de leite na elaboração de bebidas lácteas acidificadas carbonatadas

Boccia, Juliana Nogueira 25 May 2018 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-07-04T13:35:00Z No. of bitstreams: 0 / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-07-04T14:22:18Z (GMT) No. of bitstreams: 0 / Made available in DSpace on 2018-07-04T14:22:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2018-05-25 / A proposta deste estudo foi oferecer novas alternativas para o aproveitamento sustentável do soro desproteinado através do desenvolvimento e disponibilização de tecnologias simples de fabricação de bebidas lácteas acidificadas carbonatadas, com vida útil estendida, sem a utilização de tratamentos térmicos extremos. Foram utilizados três diferentes tipos de soros desproteinados (permeado de ultrafiltração, soro de ricota e soro ácido obtido da fabricação de queijos coagulados por acidificação direta), que normalmente são descartados pelas indústrias de laticínios. Para cada tipo de soro foram produzidas bebidas acidificadas carbonatadas em 3 repetições que foram analisadas ao longo do período de 60 dias. Verificou-se diferenças significativas entre as bebidas em relação á acidez, pH e viscosidade. Porém, para cada bebida, não houveram diferenças significativas em relação ao tempo, o que significa que permaneceram estáveis sob esses aspectos durante os 60 dias de armazenamento. Entretanto, pôde - se observar a deposição de proteínas que iniciou entre 20 e 30 dias de estocagem , em razão do pH baixo, e à perda de capacidade do estabilizante de manter essas proteínas dispersas. Os produtos apresentaram estabilidade microbiológica durante todo o tempo de estocagem sob refrigeração, não apresentando contagem de microrganismos patogênicos, confirmando assim a eficácia das barreiras microbiológicas aplicadas (pH, tratamento térmico e dióxido de carbono). As análises sensoriais demonstraram que as bebidas apresentaram boa aceitação. No entanto, a bebida produzida com soro permeado de ultrafiltração obteve maior aceitação e foi preferida em relação às demais. Ao longo do tempo de estocagem as bebidas apresentaram a mesma aceitabilidade sensorial. A bebida láctea desenvolvida pode agregar valor ao soro desproteinado permitindo o seu uso adequado e sustentável por parte das indústrias de laticínios. / The purpose of this study was to offer new alternatives for the sustainable use of unprocessed whey through the development and availability of simple technologies for the production of acidified carbonated dairy drinks with an extended shelf life without the use of extreme heat treatments. Three different types of deproteinated sera (ultrafiltration permeate, ricotta whey and acid whey obtained from the manufacture of cheeses coagulated by direct acidification) were used, which are normally discarded by the dairy industry. For each type of serum, acidified carbonated beverages were produced in 3 replicates that were analyzed over the 60 day period. There were significant differences between the beverages in relation to acidity, pH and viscosity. However, for each beverage, there were no significant differences in time, which means that they remained stable under these aspects during the 60 days of storage. However, protein deposition occurred between 20 and 30 days of storage due to the low pH and the loss of capacity of the stabilizer to keep these proteins in solution. The products presented microbiological stability during the whole storage time under refrigeration, not counting pathogenic microorganisms, thus confirming the effectiveness of the applied microbiological barriers (pH, heat treatment and carbon dioxide). Sensory analysis showed that the drinks were well accepted. However, the beverage produced with permeated ultrafiltration serum obtained greater acceptance and was preferred over the others. Throughout the time of storage the drinks presented the same sensorial acceptability. The developed dairy beverage can add value to the unprotected whey allowing its proper and sustainable use by the dairy industries.
150

Métodos alternativos de purificação do polissacarídeo capsular de Haemophilus influenzae tipo b. / Alternative methods for purification of capsular polysaccharide produced by Haemophilus influenzae type b.

Silvia Maria Ferreira Albani 02 February 2009 (has links)
Haemophilus influenzae tipo b é uma bactéria Gram-negativa, patogênica causadora de meningites em crianças. A cápsula polissacarídica (PSb) é o principal fator de virulência e é usado como antígeno vacinal. O método clássico de purificação do PSb envolve várias etapas de precipitação com etanol, fenol e detergente catiônico (inflamável, corrosivo e tóxico), e etapas de ultracentrifugação. O objetivo deste estudo foi substituir total ou parcial as precipitações e/ou uso das centrífugas por cromatografia, digestão enzimática, microfiltração e ultrafiltração tangencial. As cromatografias de troca iônica e de filtração em gel não apresentaram boas purificações, entretanto a hidrofóbica pode eliminar as proteínas contaminantes. As precipitações com etanol foram necessárias para obter a pureza requerida. O etanol de alguma forma favoreceu a ação enzimática e facilitou a posterior ultrafiltração. A separação com etanol em fibra-oca de microfiltração tangencial mostrou melhores purificações do que a centrifugação, mas com uso repetido verificou-se redução na eficiência. / Haemophilus influenzae type b is Gram-negative pathogenic bacterium cause meningitis in children. The capsular polysaccharide (PSb) is the main virulence factor and it is used as vaccine antigen. The classical PSb purification process includes ethanol, phenol and cationic detergent precipitations (explosion prone, corrosive, toxic) and ultracentrifugation steps. The aim of this work was to replace total or partial ethanol precipitations steps and/or elimination of centrifugation by chromatography methods, enzymatic digestion and ultrafiltration (UF) or microfiltration. The results have showed that ion exchange chromatography and gel filtration did not result in good purification, however the hydrophobic can be used for proteins elimination. The ethanol precipitation steps are necessary to achieve the required purity of PSb. In some way ethanol contributed for enzymes action and further improvements in the UF. The ethanol separation with hollow fiber microfiltration exhibited better purification than centrifugation, but after some uses the efficiency has reduced.

Page generated in 0.088 seconds