• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Algorithm Oriented to the Detection of the Level of Blood Filling in Venipuncture Tubes Based on Digital Image Processing

Castillo, Jorge, Apfata, Nelson, Kemper, Guillermo 01 January 2021 (has links)
El texto completo de este trabajo no está disponible en el Repositorio Académico UPC por restricciones de la casa editorial donde ha sido publicado. / This article proposes an algorithm oriented to the detection of the level of blood filling in patients, with detection capacity in millimeters. The objective of the software is to detect the amount of blood stored into the venipuncture tube and avoid coagulation problems due to excess fluid. It also aims to avoid blood levels below that required, depending on the type of analysis to be performed. The algorithm acquires images from a camera positioned in a rectangular structure located within an enclosure, which has its own internal lighting to ensure adequate segmentation of the pixels of the region of interest. The algorithm consists of an image improvement stage based on gamma correction, followed by a segmentation stage of the area of ​​pixels of interest, which is based on thresholding by HSI model, in addition to filtering to accentuate the contrast between the level of filling and staining, and as a penultimate stage, the location of the filling level due to changes in the vertical tonality of the image. Finally, the level of blood contained in the tube is obtained from the detection of the number of pixels that make up the vertical dimension of the tube filling. This number of pixels is then converted to physical dimensions expressed in millimeters. The validation results show an average percentage error of 0.96% by the proposed algorithm. / Revisión por pares

Page generated in 0.0669 seconds