This diploma thesis deals with the flow modelling in the ejector using the FLUENT software. It develops a diploma thesis created in the past, where a mathematical flow model in the ejector was created and experimentally tested. The aim of this work is to analyze the ejector calculations and to model a flow in an ejector of the same shape as in the experiment and under the same conditions, too. Another objective was to assess the influence of the throat length and to examine if the pressure in the ejector mixing chamber remains constant. Finally, the disagreement between the experimental figures and the ones gained from the mathematical model of the ejector are discussed.