abstract: Amphipathic molecules consist of hydrophilic and hydrophobic regions, which make them surface-active molecules. The uniqueness of these compounds results in inducing low surface tension and self-assembly of the molecules inside a solvent which have been exploited in personal care, the oil industry and agriculture industry. Amphipathic molecules are also used in the healthcare industry as drug delivery systems and other bio-nanotechnology applications.
In this thesis, a novel series of grafted siloxanes have been explored for their probable application in the healthcare industry. The siloxanes are grafted with poly(ethylene glycol) (PEG) and quaternary ammonium salt (QUAT). The effects of varying 1) molar ratios of QUAT to PEG and 2) PEG chain length on contact angle, surface tension, critical micelle concentration (CMC), and micelle assembly properties were studied. In contact angle experiments, the hydrophilicity of grafted siloxanes increased by grafting PEG and QUAT. The amphiphilicity increases and CMC decreases as the PEG chain length shortens. Adding QUAT also reduces CMC. These trends were observed in surface tension and Isothermal Titration Calorimetry experiments. A change in self-assembly behaviour was also observed in Dynamic Light Scattering experiments upon increasing the PEG chain length and its ratio relative to the quaternary ammonium in the siloxane polymer.
These polymers have also been studied for their probable application as a sensitive 1H NMR spectroscopy indicator of tissue oxygenation (pO2) based on spectroscopic spin-lattice relaxometry. The proton imaging of siloxanes to map tissue oxygenation levels (PISTOL) technique is used to map T1 of siloxane polymer, which is correlated to dynamic changes in tissue pO2 at various locations by a linear relationship between pO2 and 1/T1. The T1-weighted echo spin signals were observed in an initial study of siloxanes using the PISTOL technique.
The change in the ratio of QUAT to PEG and the varying chain length of PEG have a significant effect on the physical property characteristics of siloxane graft copolymers. The conclusions and observations of the present work serve as a benchmark study for further development of adaptive polymers and for the creation of integrated “nanoscale” probes for PISTOL oximetry and drug delivery. / Dissertation/Thesis / Masters Thesis Chemical Engineering 2018
Identifer | oai:union.ndltd.org:asu.edu/item:50503 |
Date | January 2018 |
Contributors | Gupta, Srishti (Author), Green, Matthew D (Advisor), Kodibagkar, Vikram (Committee member), Holloway, Julianne (Committee member), Arizona State University (Publisher) |
Source Sets | Arizona State University |
Language | English |
Detected Language | English |
Type | Masters Thesis |
Format | 79 pages |
Rights | http://rightsstatements.org/vocab/InC/1.0/ |
Page generated in 0.002 seconds