Rolling element bearings are one of the most significant elements and frequently-used components in mechanical systems. Bearing fault detection and diagnosis is important for preventing productivity loss and averting catastrophic failures of mechanical systems. In industrial applications, bearing life is often difficult to predict due to different application conditions, load and speed variations, as well as maintenance practices. Therefore, reliable fault detection is necessary to ensure productive and safe operations.
Vibration analysis is the most widely used method for detection and diagnosis of bearing malfunctions. A measured vibration signal from a sensor is often contaminated by noise and vibration interference components. Over the years, many methods have been developed to reveal fault signatures, and remove noise and vibration interference components.
Though many vibration based methods have been proposed in the literature, the high frequency resonance (HFR) technique is one of a very few methods have received certain industrial acceptance. However, the effectiveness of the HFR methods depends, to a great extent, on some parameters such as bandwidth and centre frequency of the fault excited resonance, and window length. Proper selection these parameters is often a knowledge-demanding and time-consuming process. In particular, the filter designed based on the improperly selected bandwidth and center frequency of the fault excited resonance can filter out the true fault information and mislead the detection/diagnosis decisions. In addition, even if these parameters can be selected properly at beginning of each process, they may become invalid in a time-varying environment after a certain period of time. Hence, they may have to be re-calculated and updated, which is again a time-consuming and error-prone process. This undermines the practical significance of the above methods for online monitoring of bearing conditions.
To overcome the shortcomings of existing methods, the following four non-parametric and non-filtering methods are proposed:
1. An amplitude demodulation differentiation (ADD) method,
2. A calculus enhanced energy operator (CEEO) method,
3. A higher order analytic energy operator (HO_AEO) approach, and
4. A higher order energy operator fusion (HOEO_F) technique.
The proposed methods have been evaluated using both simulated and experimental data.
Identifer | oai:union.ndltd.org:LACETR/oai:collectionscanada.gc.ca:OOU.#10393/30689 |
Date | 12 March 2014 |
Creators | Faghidi, Hamid |
Source Sets | Library and Archives Canada ETDs Repository / Centre d'archives des thèses électroniques de Bibliothèque et Archives Canada |
Language | English |
Detected Language | English |
Type | Thèse / Thesis |
Page generated in 0.0019 seconds