The Diagnostic Instrumentation and Analysis Laboratory (DIAL) at Mississippi State University was awarded a project to study the feasibility of measuring particulate matter downstream of a high efficiency particulate air (HEPA) filter by testing commercially available equipment used to monitor the downstream side of a HEPA filter. In order to perform the work required for this project, a test stand to accommodate a 12? x 12? x 11.5? HEPA filter with a rated flow of 250 standard cubic feet per minute (scfm) was constructed. The test stand required an aerosol generator capable of producing a mass loading rate of 30 mg/m3 of dry aerosol at the face of the HEPA filter. It was determined that there was not a commercially available aerosol generator that quite fit the needs of the project. Therefore, it was necessary to develop an aerosol generator with the capabilities required for the project.
Identifer | oai:union.ndltd.org:MSSTATE/oai:scholarsjunction.msstate.edu:td-2293 |
Date | 10 December 2005 |
Creators | Hogancamp, Tracy Kristina |
Publisher | Scholars Junction |
Source Sets | Mississippi State University |
Detected Language | English |
Type | text |
Format | application/pdf |
Source | Theses and Dissertations |
Page generated in 0.0015 seconds