Return to search

Geometry and Physical Properties of the Chelungpu Fault, Taiwan, and Their Effect on Fault Rupture

Rupture of the Chelungpu fault during the September 21, 1999, 7.6 Mwearthquake in Taiwan caused a 90-Jr,m-long surface rupture with variable displacement along strike. Analysis of core from two holes drilled through the fault zone, combined with geologic mapping and detailed investigation from three outcrops, define the fault geometry and physical properties of the Chelungpu fault in its northern and southern regions. In the northern region, the fault dips 45-60° east parallel to bedding and consists of a narrow (1-20 cm) core of dark-gray, sheared clay gouge at the base of a 30-50 m zone of increased fracture density that is confined asymmetrically to the hanging wall. Microstructural analysis of the fault gouge indicates the presence of extremely narrow clay zones (50-300 μm thick) that are interpreted as the fault rupture surfaces. Few shear indicators are observed outside of the fault gouge, which implies that slip was localized in the gouge in the northern region. Slip localization along a bed-parallel surface resulted in less high-frequency ground motion and larger displacements during the earthquake than in the southern region. Observations from the southern region indicate that the fault dips 20-30° at the surface and consists of a wide (20- 70 m-thick) zone of sheared, foliated shale with numerous gouge zones. A footwall-ramp geometry juxtaposes 2000-3000 m of flat-lying Quaternary Toukoshan Formation in the footwall with Pliocene and Miocene, east-dipping siltstone and muds tone in the hanging wall. The wide, diffuse fault zone contributed to the lower displacement and higher frequency ground motion in the southern region during the 1999 earthquake. The structure in the northern region is the result of the fault being a very young (<50 >ka) fault segment in the hanging wall of an older segment of the Chelungpu fault, buried in the Taichung basin. The fault in the southern region is located on an older (~1 Ma) fault trace. The contrasting fault properties in the different regions are responsible for the variability in strong-motion and displacement observed during the 1999 earthquake.

Identiferoai:union.ndltd.org:UTAHS/oai:digitalcommons.usu.edu:etd-7786
Date01 May 2002
CreatorsHeermance, Richard V.
PublisherDigitalCommons@USU
Source SetsUtah State University
Detected LanguageEnglish
Typetext
Formatapplication/pdf
SourceAll Graduate Theses and Dissertations
RightsCopyright for this work is held by the author. Transmission or reproduction of materials protected by copyright beyond that allowed by fair use requires the written permission of the copyright owners. Works not in the public domain cannot be commercially exploited without permission of the copyright owner. Responsibility for any use rests exclusively with the user. For more information contact digitalcommons@usu.edu.

Page generated in 0.0827 seconds