Return to search

Melhoria na eficiÃncia de um refrigerador termoelÃtrico: Controle Preditivo Baseado em Modelo aplicado à regulaÃÃo da temperatura do reservatÃrio de Ãgua gelada. / An energy-saving model based predictive control strategy on thermoelectric water cooler dispenser

nÃo hà / O uso racional de recursos à pauta recorrente nas discussÃes acerca do desenvolvimento sustentÃvel e tem estimulado o projeto de equipamentos mais eficientes quanto ao consumo de energia elÃtrica. Agentes regulamentadores e certificadores estabelecem regras para o funcionamento e para a classificaÃÃo de eletrodomÃsticos quanto ao consumo de energia elÃtrica a fim de formalizar a relaÃÃo entre o desempenho dos mesmos e a manutenÃÃo indefinida dos recursos. Nesse contexto, lanÃa-se mÃo do projeto de um controlador preditivo baseado em modelo aplicado à regulaÃÃo da temperatura do reservatÃrio de Ãgua gelada de um refrigerador termoelÃtrico obedecendo as especificaÃÃes da norma internacional ANSI18 que determina condiÃÃes funcionais para bebedouros com refrigeraÃÃo mecÃnica incorporada, concomitantemente buscando atender aos requisitos para a certificaÃÃo ENERGY STAR quanto ao critÃrio de eficiÃncia energÃtica. Para tanto foram realizadas as etapas de i) Modelagem e IdentificaÃÃo do Processo: foi desenvolvido um modelo em termos de funÃÃo de transferÃncia do sistema de refrigeraÃÃo termoelÃtrico de fluidos atravÃs de modelagem fenomenolÃgica; foram realizados experimentos para a identificaÃÃo de parÃmetros de modelos discretos pelo mÃtodo caixa branca; foi desenvolvido critÃrio de seleÃÃo de modelo baseado na capacidade de simulaÃÃo e caracterÃsticas do resÃduo de simulaÃÃo; ii) Estudo do Controlador Preditivo Baseado em Modelo: foi projetado e implementado na planta um controlador preditivo baseado em um dos modelos parametrizados para regulaÃÃo da temperatura do reservatÃrio interno; foi analisado o desempenho do controlador segundo a norma regulamentadora; iii) Estudo da EficiÃncia do Controlador: foi analisado o desempenho do controlador quanto a capacidade do protÃtipo em atender aos requisitos que o qualificam à obtenÃÃo de certificado segundo critÃrio de eficiÃncia energÃtica para regulaÃÃo da temperatura interna do reservatÃrio e, por fim, realizado um estudo comparativo entre a estratÃgia de controle biestÃvel aplicada atualmente ao processo e a estratÃgia proposta. / The rational use of resources is a recurring theme in sustainable development discussions and has stimulated the development of more efficient electrical power consumption appliances. Regulators and Certifiers agencies set standards for the functionality requirements and for the electric power consumption classification of devices in order to formalize the relationship between performance and maintenance of these resources indefinitely. Thus a model based predictive controller was applied to a thermoelectric cooler to attain the international standard ANSI18 specifications for water cooler dispensers and to meet ENERGY STAR$ iny^{ extregistered}$ energy efficiency requirements. A phenomenological linear model was obtained and the respective parameters were identified by using least squares algorithm; experiments were performed to identify the parameters of the discrete transfer functions; a model criterion selection based on simulation capabilities and residue characteristics was developed; a model based predictive controller was designed and applied using one of the models identified; the controller performance was analyzed attending to the ANSI18 standard and according to energy performance certificates; a comparative study between the bistable control and the proposed strategy was made for performance analysis. Simulation and experimental tests have shown compromise between the simulation capability and residue characteristic criterion. The closed loop system behavior allowed energy saving in standby temperature regulating compared to thermostat control mode. The new control strategy achieved ENERGY STAR energy-efficiency criteria certification requirements infeasible for traditional regulation.

Identiferoai:union.ndltd.org:IBICT/oai:www.teses.ufc.br:7092
Date31 July 2013
CreatorsDaniel Lopes do Amaral
ContributorsBismark Claure Torrico
PublisherUniversidade Federal do CearÃ, Programa de PÃs-GraduaÃÃo em Engenharia ElÃtrica, UFC, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageUnknown
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFC, instname:Universidade Federal do Ceará, instacron:UFC