Return to search

Mathematical models of ion transport through nafion membranes in modified electrodes and fuel cells without electroneutrality

Electrodes are modified with polymer films to grant novel permeability. Often, redox probes partition from solution into film and are electrolyzed at the electrode. This creates a flux of probe into the polymer film and a flux of electrolyzed probe out of the polymer film. Transport of the probe through the film is governed by diffusion and migration, mathematically described from the Nernst-Planck equation as J_{i}=-D_{i}((∂C_{i}(x,t))/(∂x))-((z_{i}F)/(RT))D_{i}C_{i}(x,t)((∂Φ(x,t))/(∂x)) where x is the distance from the electrode, t is time, C_{i}(x,t) is space and time dependant concentration of the probe i, z_{i} is the charge of the probe i, F is Faraday's constant, R is the gas constant, T is absolute temperature, J_{i} is the flux of the probe i, D_{i} is the diffusion constant of the probe i and Φ(x,t) is the space and time dependant potential.
In most natural systems, charge accumulation is not appreciably noticed, the system behaves in such a way that a charged ion is neutralized by a counterion. This is called electroneutrality and is mathematically represented by Laplace's condition on the potential, ((∂²Φ)/(∂x²))=0. In some systems, it is not clear if counterions are readily available to neutralize an ion. In such a system, there may not be electroneutrality, giving Poisson's equation to replace Laplace's condition as ((∂²Φ)/(∂x²))=-(F/ɛ)∑_{i}z_{i}C_{i}(x,t) where ɛ is the relative permittivity. The addition of Poisson's condition makes the system nonsolvable. In addition, the magnitude of F/ɛ creates difficulty simulating the system using standard techniques. The first system investigated determines the concentration and potential profiles over the polymer membrane of a fuel cell without electroneutrality.
In some systems, the probes can not easily diffuse around each other, certain polymer film environments prevent such a swap of location as diffusion is commonly thought to occur. A more generalized form of the Nernst-Planck equation describes spatially varying diffusion coefficient as J=-D(x,t)((∂C(x,t))/(∂x))-((zF)/(RT))D(x,t)C(x,t)((∂Φ(x,t))/(∂x)). D(x,t) is space and time dependent diffusion, usually thought of with a physical diffusion term and an ion hopping term. The second system this thesis investigates is a modified electrode system where electron hopping is responsible for a majority of the probe transport within the film.
Lastly, the beginnings of a method are presented to easily determine the physical diffusion rate of a probe within a modified electrode system based on known system parameters.

Identiferoai:union.ndltd.org:uiowa.edu/oai:ir.uiowa.edu:etd-1919
Date01 July 2010
CreatorsSchmidt, Stephanie Ann
ContributorsLeddy, Johna, Ströhmer, Gerhard, Ayati, Bruce P.
PublisherUniversity of Iowa
Source SetsUniversity of Iowa
LanguageEnglish
Detected LanguageEnglish
Typedissertation
Formatapplication/pdf
SourceTheses and Dissertations
RightsCopyright 2010 Stephanie Ann Schmidt

Page generated in 0.002 seconds