The classical methodologies for synchronous machine modeling provide a solid estimation for synchronous machine behavior but are limited in terms of accuracy due to the assumptions made in the modeling process. The equivalent circuit model developed by the classical approach breaks down the entire machine into a singular impedance component. This allows the model to be generated more quickly but limits its accuracy. In the pursuit of developing a more realistic model, this thesis outlines the parameter measurement of a Hampden SM-100 synchronous machine. In determining the SM-100’s experimental parameters, this thesis executes and analyzes new experimental approaches to synchronous machine modeling. With the results of these approaches, a model for the Hampden SM-100 synchronous machine is developed that considers the rotor, stator, and core parameters of the synchronous machine separately.
Identifer | oai:union.ndltd.org:CALPOLY/oai:digitalcommons.calpoly.edu:theses-4242 |
Date | 01 June 2023 |
Creators | Kargol, Andrew |
Publisher | DigitalCommons@CalPoly |
Source Sets | California Polytechnic State University |
Detected Language | English |
Type | text |
Format | application/pdf |
Source | Master's Theses |
Page generated in 0.0019 seconds