This work is concerned with posibility of measuring a wind flow by Von Karman vortex sheed structure. The bluff body is situated in the way of air flow propagation and consequentally vortexes will be appeared. Important part of speedmeter design is measurment chamber must allow to vortex sheed propagation. The transient and the reciever are situated vertically to propagation of flow.The Ultrasonic carrier is transmitted and modulated by freqency of vortex sheeding in measurment chamber.Demodulator uses PLL to “focusing“ detection of the ultrasonic beam. This can be indicated like lock and unlock phase loop. From known value of sheed frequency can be directly calculated speed of flow.