[en] A NUMERICAL STUDY OF THE INFLUENCE OF THE INCLINATION OF THE AORTIC VALVE ON THE BLOOD FLOW IN THE ASCENDING AORTA. / [pt] ESTUDO NUMÉRICO DA INFLUÊNCIA DA INCLINAÇÃO DA PRÓTESE VALVAR AÓRTICA NO FLUXO SANGUÍNEO EM AORTA ASCENDENTE

[pt] As patologias na valva aórtica representam umas das principais causas de óbito no mundo. Nos casos de estenose aórtica grave, a substituição da valva nativa é necessária. Existem dois mecanismos de substituição de valva aórtica: cirurgia convencional, através da toracotomia, ou o implante valvar aórtico percutâneo (TAVI, Transcatheter Aortic Valve Implantation). O posicionamento coaxial da prótese valvar em relação ao ânulo aórtico influência o fluxo sanguíneo transvalvar, podendo contribuir para o remodelamento aórtico, culminando em dilatações aneurismáticas, dissecção aórtica e processo aterosclerótico. O presente estudo avalia numericamente a influência do posicionamento coaxial da prótese valvar nas estruturas hemodinâmicas na região de aorta ascendente e início do arco aórtico, durante um ciclo cardíaco. A geometria anatômica avaliada corresponde a um modelo aórtico de um paciente que foi submetido ao implante valvar percutâneo. O escoamento foi obtido com o modelo de turbulência (K - W), utilizando o software ANSYS-Fluent. A interação entre a complacência aórtica e o fluxo sanguíneo durante o ciclo cardíaco foi obtida empregando simulações do tipo FSI (Fluid Structure Interaction). A metodologia numérica foi validada através de comparações com dados experimentais nobres do tipo PIV estereoscópico, com excelente concordância do campo de velocidade e tensões de Reynolds. Observou-se a importância do posicionamento coaxial da prótese valvar aórtica com relação ao direcionamento do jato e área de impacto na parede da aorta; influenciando na formação de regiões de recirculação na raiz da aorta e aorta ascendente; com diferentes estruturas coerentes (vórtices). Identificou-se as regiões de alta pressão e tensão de cisalhamento na parede da aorta, assim como de alta intensidade das grandezas turbulentas no volume interno da aorta. A partir da análise dos resultados foi possível sugerir que a posição coaxial ideal da prótese pode ser obtida quando é direcionada à parede esquerda da aorta com uma inclinação de 4 graus. / [en] Aortic valve pathologies are one of the leading causes of death in the world. In cases of severe aortic stenosis, replacement of the native valve is necessary. There are two mechanisms of aortic valve replacement: conventional surgery through thoracotomy or Transcatheter Aortic Valve Implantation (TAVI). Coaxial positioning of the valve prosthesis in relation to the aortic annulus influences on the transvalvar blood flow, which may contribute to aortic remodeling, culminating in aneurysmal dilations, aortic dissection and atherosclerotic process. The present thesis evaluates the influence of the coaxial positioning of the valve prosthesis on hemodynamic structures in the ascending aorta and the beginning of the aortic arch, during a cardiac cycle. The anatomical geometry evaluated was the aortic model of a specific patient after being submitted to percutaneous valve implantation procedure. The flow was obtained with the (K - W) turbulence model, using ANSYS-Fluent software. Interaction between aortic compliance and blood flow during the cardiac cycle was obtained using simulations FSI (Fluid Structure Interaction). The numerical methodology was validated through comparisons with noble experimental data obtained from stereoscopic PIV method, with excellent agreement of the velocity field and Reynolds stress. It was observed the importance of the coaxial positioning of the aortic valve prosthesis in relation to the jet direction and the impact area in the aortic wall, influencing the formation of recirculation regions in the aortic root and ascending aorta; with different coherent structures (vortices). The regions of high pressure and shear stress were identified in the aortic wall, as well as high intensity turbulent quantities in the internal aortic volume. From the results analysis it was possible to suggest that the ideal coaxial position
of the prosthesis can be obtained when it is directed to the left wall of the aorta with an inclination of 4 degrees.

Identiferoai:union.ndltd.org:puc-rio.br/oai:MAXWELL.puc-rio.br:45714
Date07 October 2019
CreatorsIVAN FERNNEY IBANEZ AGUILAR
ContributorsANGELA OURIVIO NIECKELE
PublisherMAXWELL
Source SetsPUC Rio
LanguagePortuguese
Detected LanguagePortuguese
TypeTEXTO

Page generated in 0.0988 seconds