In this thesis a vertical turbine mixed flow pump that has a flow rate of 40 l/s and 16 mwc head at 2900 rpm is designed. Effect of design parameters are investigated and flow inside the pump is analyzed with the help of numerical experimentations. The designed pump is manufactured and tested in Layne Bowler Pumps Company and completed in TÜ / BiTAK - TEYDEB project. Pump is designed in the tolerance limits that are defined in the standard TS EN ISO 9906. Numerical experimentation results for performance charecteristics show the same trend with the test results.
In addition, axial thrust measurements are done on the designed pump with using load cells. Effect of balancing holes and balancing ring are investigated. Balancing holes are drilled at various diameters at the back side of the impellers and its effect is analyzed on the pump performance characteristics. Test results are compared with different approaches.
Identifer | oai:union.ndltd.org:METU/oai:etd.lib.metu.edu.tr:http://etd.lib.metu.edu.tr/upload/2/12608972/index.pdf |
Date | 01 October 2007 |
Creators | Cirit, Ali |
Contributors | Albayrak, Kahraman |
Publisher | METU |
Source Sets | Middle East Technical Univ. |
Language | English |
Detected Language | English |
Type | M.S. Thesis |
Format | text/pdf |
Rights | To liberate the content for METU campus |
Page generated in 0.002 seconds