Return to search

Emprego de diferentes energias em conjunto com nano-materiais para degradação de Atrazina / Use of different energies in conjunction with nanomaterials nanomaterials for degradation of atrazine

Atrazina 5 mg L-1 foi submetida a ensaios fotoliticos utilizando as radiações ultravioleta (UV), microondas (MW), ultrassom (US), MW-UV, US-UV, apresentando remoção de 60% (120 min – UV), 40% (3 min – MW), 2% (80 min – US), 67% (120 min – US-UV) e 87% (4 min – MW-UV) evidenciando que a junção de energias atua de modo otimizar o processo de degradação da atrazina. Após os processos fotoliticos, as amostras foram submetidas à varredura de comprimento de onda no intervalo de 190 a 300 nm, onde os gráficos de varredura espectral explicitaram a degradação do composto original (Atrazina). Estudos fotoliticos utilizando as energias microondas e ultravioleta associadas foram executados para soluções contendo diferentes valores de pH, onde as amostras irradiadas demonstraram que em pH=8,37 a degradação foi mais eficiente, apresentando variação de 10% de eficiência entre o pH=5,14 e o pH=8,37. O tempo de radiação apresentou degradação significativamente rápida até o valor de 90 segundos de exposição, sendo que após este intervalo (0 a 90), a degradação apresenta-se menos acentuada. Para o monitoramento dos produtos resultantes dos processos de degradação, desenvolveu-se um método de separação e determinação de atrazina e 7 (sete) de seus produtos de degradação, onde após vários ensaios, chegou-se as condições ideais de separação, que são, vazão de fase móvel constante de 1mL.min-1, temperatura controlada a 25ºC, fase móvel composta por tampão pH=7,0 (19,5 mmol L-1 KH2PO4 / 30,5 mmol L-1 K2HPO4) e acetonitrila (Grau HPLC), sendo utilizado o sistema em modo gradiente com as seguintes condições: de 0 a 3 min (100% tampão PO43-/0% ACN), de 3 a 10 min (80% tampão PO43-/20% ACN), de 10 a 20 min (30% tampão PO43-/70% ACN) e de 20 a 25 min (10% tampão PO43-/90% ACN), permitindo deste modo a determinação dos respectivos tempos de retenção (minutos) para os compostos DEDIHAT (2,5 min), DIHAT (9,17 min), DEDIAT (9,3 min), DEHAT (10,7 min), DIAT (14,6 min), HAT (15,5 min), DEAT (16,6 min) e ATZ (20,9 min) empregando a detecção no comprimento de onda de 221nm. / Atrazine 5 mg L-1 was subjected to photolytic assays using ultraviolet radiation (UV), microwave (MW), ultrasound (US), MW-UV, UV-US, with removal of 60% (120 min - UV) 40% (3 min - MW), 2% (80 min - US), 67% (120 min - US / UV) and 87% (4 min - MW / UV) showing that the addition of energy acts in order to optimize the process of degradation of atrazine. After photolytic processes, the samples were subjected to wavelength sweep in the range of 190 to 300nm, where the graphics made explicit spectral scan degradation of the parent compound (Atrazine). Photolytic studies using the microwave and ultraviolet energy associated were performed for solutions containing different pHs, where the irradiated samples demonstrated that at pH = 8.37 degradation was more efficient, with 10% variation in efficiency between pH = 5.14 and pH = 8.37. The radiation time showed significantly degrade rapidly to the value of 90 seconds of exposure, and after this interval (0 to 90 sec), degradation has become less pronounced. For the monitoring of products resulting from degradation processes, developed a method of separation and determination of Atrazine and seven (7) of its metabolites, which after several trials, was reached optimal conditions of separation, which are flow constant mobile phase 1mL.min-1, controlled 25 ° C, mobile phase consisting of pH 7.0 buffer (19,5 mmol L-1 KH2PO4 / 30,5 mmol L-1 KH2PO4) and acetonitrile (HPLC grade) the system being used in gradient mode with the following conditions: 0 to 3 min (100% Buffer PO43- / 0% ACN) from 3 to 10 min (80% PO43- buffer / 20% ACN), 10 to 20 min (30 % PO43- buffer / 70% ACN), and 20 to 25 min (10% PO43-- buffer / 90% ACN), thereby permitting determination of their retention times (minutes) for the compounds DEDIHAT (2.5 min), DIHAT (9.17 min) DEDIAT (9.3 min) DEHAT (10.7 min) DIAT (14.6 min), HAT (15.5 min), DEAT (16.6 min) and ATZ (20.9 min) using detection at a wavelength of 221nm.

Identiferoai:union.ndltd.org:IBICT/oai:10.254.254.39:tede/680
Date06 July 2015
CreatorsMOREIRA, Ailton José
ContributorsFRESCHI, Gian Paulo Giovanni, http://lattes.cnpq.br/7759622872412835, LEOD, Tatiana Cristina de Oliveira Mac, NOGUEIRA, Raquel Fernandes Pupo
PublisherUniversidade Federal de Alfenas, Instituto de Ciência e Tecnologia, Brasil, UNIFAL-MG, Programa de Pós-Graduação em Ciência e Engenharia Ambiental
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UNIFAL, instname:Universidade Federal de Alfenas, instacron:UNIFAL
Rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/, info:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds