Orientador : Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-02T10:06:11Z (GMT). No. of bitstreams: 1
Nascimento_PatriciaMazzantedo_M.pdf: 8382154 bytes, checksum: c1ba989f8a1c57443cba37e8a18de7be (MD5)
Previous issue date: 2002 / Resumo: O Iodo de esgoto é um resíduo gerado no tratamento da fase líquida dos esgotos sanitários e que precisa ser disposto de maneira adequada para não causar riscos de contaminação ao ambiente. O excesso de nutrientes como, nitrogênio e fósforo presentes no Iodo de esgoto, podem provocar o comprometimento do solo e da água subterrânea, após sua aplicação no solo. Neste estudo experimental, foram feitas aplicações de Iodo líquido digerido em reatores com 0,88 m3 de volume (1,00 m x 0,88 m2), preenchidos com solo do tipo franco-argiloso. As aplicações realizaram-se a cada 40 dias (com base na respirometria), durante um ano, totalizando 9 aplicações de Iodo ao final do período. Foram utilizadas as taxas 2,5; 5 e 7,5 t/ha a cada 40 dias (calculado na base seca), o líquido infiltrado no solo, foi coletado ao longo do perfil do solo nas profundidades: 0,25; 0,50; 0,75 m e 1,0 m (descarte de fundo). O líquido infiltrado foi avaliado quanto aos parâmetros nitrogênio (amônia, nitrito e nitrato) e fósforo total. Após o término da pesquisa, os resultados obtidos, mostraram que a taxa 2,5 t/ha aplicada a cada 40 dias, durante um ano, foi a que melhor resultado apresentou no que diz respeito a proteção das águas subterrâneas contra contaminação com nitrato e fósforo. As concentrações de nitrato no líquido coletado a 1,0 m, ficou em torno de 6,0 mg de N/L e não ultrapassou os 10 mg N/L estabelecido pela legislação, o fósforo total ficou em torno de 0,003 mg de P/L. Estas concentrações foram obtidas mesmo após intensa precipitação pluviométrica / Abstract: The sewage sludge is a residue produced from the wastewater treatment and it needs to be disposed in a correct way so that it can't cause environment contamination. The excess of nutrients as, nitrogen and phosphorus, present in sewage sludge can cause the soil and groundwater contamination after its application in soil. In this experimental study sewage sludge were made in reactor with 0,88 m3 (1,00 m x 0,88 m2) filled with soil. The sewage sludge was applied every 40 days (related to the respirometer test) , during one year, in total 9 sewage sludge application. The rates 2,5; 5,0 and 7,5 t/ha were used (calculated in dry weight) and the infiltrated liquid in soil was coleted in the 0,25 ; 0,50 ; 0,75 and 1,00 m depht. The investigated parameters in the infiltrated liquid were (ammonia, nitrite, nitrate and phosphorus ). The research shows that the 2,5 t/ha rate were the best result related to the groundwater contamination. The nitrogen (nitrate) and phosphorus forms concentration were under the limits set by the Brazilian legislation, even after intense precipitation / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258378 |
Date | 11 May 2002 |
Creators | Nascimento, Patricia Mazzante do |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Coraucci Filho, Bruno, 1948-, Filho, Bruno Coraucci |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 101p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.002 seconds