This master‘s thesis deals with a centrifugal pump running in reverse (turbine) mode, often called “pump-as-turbine”. The introduction lists basic principles and information about the direct (pump) and reverse modes. Several methodologies for predicting reverse operating point and efficiency evolution are used and compared with simulation results. Using CFD simulations, results obtained with simplified (excluding impeller side wall gaps) and complete geometry (including impeller side wall gaps) are assessed. Furthermore, the results of impeller trimming are evaluated with an aim to find the maximum power and efficiency. Impeller side wall gaps effect is analyzed in terms of friction torque and power loss.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:416650 |
Date | January 2020 |
Creators | Tomšej, Radek |
Contributors | Zemanová, Lucie, Štefan, David |
Publisher | Vysoké učení technické v Brně. Fakulta strojního inženýrství |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |