Diploma thesis is focused on self-priming pump 25 - OVE Sigma pumpy Hranice s.r.o., for its function is essential the ejector which is placed in the body of the pump. On the basis of the results of measurements there are designed construction modifications using a mathematical model. For the first time were made measurements to verify the self-priming capability with determining the maximum suction height.