Return to search

Utilização dos produtos obtidos por sensoriamento remoto na caracterização da qualidade do ar na Região Metropolitana de São Paulo / Use of remote sensing derived products in the air quality characterization over the Metropolitan Area of São Paulo.

O objetivo desse trabalho foi estudar a relação entre profundidade óptica de aerossóis (AOD), obtida por sensoriamento remoto, e a concentração de material particulado (MP10 e MP2,5) medida próximo à superfície sobre a Região Metropolitana de São Paulo (RMSP). A profundidade óptica foi derivada a partir de medidas de radiâncias fornecidas pelos sensores MODIS. Estes sensores estão posicionados a bordo dos satélites EOS-TERRA e EOS-AQUA, operados pela NASA. As concentrações de MP10 e MP2,5 foram obtidas nas estações da rede operacional da CETESB. Foram feitos alguns estudos de caso considerando diferentes situações atmosféricas, aos quais se aplicou a metodologia proposta por Castanho (2005) que busca reduzir as incertezas na determinação da profundidade óptica derivada do MODIS e identificar qual o modelo de aerossol é mais adequado para aplicação em estudos de qualidade do ar. Os valores de AOD calculados para as diferentes situações foram comparados com aqueles obtidos pela AERONET e com as concentrações anteriormente citadas, buscando uma validação dos mesmos. Valores médios de AOD foram calculados para áreas de 10 km x 10 km ao redor das estações de monitoramento do MP. Testes foram realizados para verificar os efeitos de sazonalidade, da quantidade de água na coluna atmosférica, da resposta da AOD por faixas de concentração de MP10, da geometria do sensor, da presença de nuvens e da presença de aerossol acima da Camada de Mistura (CM). Os resultados foram apresentados por estações com o objetivo de se visualizar diferentes condições sobre a região estudada. Alguns dos fatores relevantes observados durante a comparação entre a concentração de MP10 e a AOD foram: a influência do período do ano e da quantidade de água na coluna atmosférica. A geometria do sensor foi fator determinante para melhora das correlações, quando limitado o ângulo de espalhamento em 140°. Situações em que há ausência de nuvens, identificadas através de imagens do MODIS no visível, também apresentaram melhores resultados. Outro fator de extrema importância foi a estrutura vertical da CM. Através de medidas obtidas de um LIDAR foi verificado que a presença de aerossóis acima da CM, a qual é determinada principalmente pelas condições atmosféricas, é determinante para as correlações entre AOD e o MP. / The main purpose of this work was to study the relationship between the Aerosol Optical Depth (AOD), obtained by remote sensing, and the particulate material concentration (PM10 and PM2.5), near to the surface over the Metropolitan Area of Sao Paulo (MASP). The Aerosol Optical Depth was retrieved based on reflectance measurements provided by MODIS sensors. These sensors are carried aboard EOS-TERRA and EOS-AQUA satellites, which are operated by NASA. The PM10 and PM2.5 concentrations were obtained in the CETESB operational network. Case studies were performed, considering several atmospheric conditions, applying the methodology proposed by CASTANHO (2005), designed both to reduce the uncertainty in the determination of the MODIS derived Optical Depth and to identify which aerosol model is more appropriated for air quality studies. Some derived results were compared with AERONET data and with the previously mentioned concentrations as a cross-check test. Mean AOD values were calculated using 10 km x 10 km area ground around PM monitoring stations. Tests were performed to estimate the effects of seasonality, atmospheric column water content, AOD response to PM10 concentration, sensor geometry, clouds and aerosol concentration above the Mixing Layer (ML). To stress the different conditions of the studied region, the results were presented considering each station. Some of the relevant observed factors in the PM10 concentration and AOD comparison were the year period influence and the atmospheric column water content. The sensor geometry was an important factor to the improvement of the obtained correlations when the scattering angle was bounded to 140°. Cloudless situations, identified by MODIS true color images, also improved the results. Another important factor was the Mixing Layer vertical structure. Using LIDAR measurements it was verified that the presence of aerosols above the ML, which is determined mainly by atmospheric conditions, is crucial for the correlations between AOD and PM.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-07122008-151154
Date28 July 2008
CreatorsLuciene Natali
ContributorsEdmilson Dias de Freitas, Jorge Alberto Martins, Márcia Akemi Yamasoe
PublisherUniversidade de São Paulo, Meteorologia, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds