<p>The report begins with a general inventory of possible technical faults in a hydropower plant and of possible fault indicating measurements. Then an investigation is made concerning a few different faults. Based on this investigation a choice on seal box condition and water leakage is made as problem for a more thorough examination, in which it is concluded that the turbine water leakage is larger when the turbine is put into operation. The examination ultimately results in a computer alarm for faults related to the seal box. Finally a few things are mentioned about flow measurement and pressure measurement in relation to the project as a whole.</p> / <p>Rapporten inleds med en övergripande sammanställning av möjliga tekniska fel i en vattenkraftstation och av möjliga felindikerande mätningar. Därefter görs en probleminventering av ett antal olika fel. Baserat på denna inventering väljes sedan tätningsboxkondition och läckvatten som problem för en mer ingående undersökning, vid vilken det konstateras att turbinvattenläckaget är större när turbinen är i drift. Undersökningen utmynnar sedan i ett datalarm för fel relaterade till tätningsboxar. Slutligen nämns något om flödesmätning och tryckmätning i relation till projektet i sin helhet.</p>
Identifer | oai:union.ndltd.org:UPSALLA/oai:DiVA.org:uu-88866 |
Date | January 2004 |
Creators | Carlsson, Magnus |
Publisher | Uppsala University, Department of Earth Sciences, Uppsala : Institutionen för geovetenskaper |
Source Sets | DiVA Archive at Upsalla University |
Language | Swedish |
Detected Language | Swedish |
Type | Student thesis, text |
Relation | UPTEC W, 1401-5765 ; 04 035 |
Page generated in 0.0019 seconds