This diploma thesis deals with matte coatings for 3D scanning purposes. The coatings are made with spray gun which uses a vibrating membrane atomizer and air blow gun. A suspension of titanium dioxide and alcohol is used as a coating material. This thesis describes the effect of the spray gun process parameters on the deposited coatings. These include, for example type of the coating suspension or setup of the blow gun. Phase Doppler Anemometry was used to measure spray characteristics. Deposited coatings were measured with profilometer and scanned with 3D scanner to study their thickness and effect on the results of 3D reconstruction. The result of this work was the coating with thickness below 1 µm with good optical properties for 3D scanning purposes. Standard deviation of the captured point cloud from the reference plane was below 0.0011 mm.