The effect of activating flux PATIG on welding arc was investigate in master thesis, A-TIG welding with flux PATIG. The test was performed on six materials with different chemical and mechanical properties. TIG and A-TIG welding was carried out after application flux. Performed require layer of PATIG flux was quite difficult. Result was compared between conventional TIG and experimental A-TIG method of welding. The best reached goals were for high-alloy steels. Typical and 3times deeper penetration was reached for A-TIG compared to conventional TIG welding.