Return to search

Avaliação in vitro da resistencia ao cisalhamento de sistemas adesivos

Orientadores: Luis Roberto Marcondes Martins, Luis Andre Freire Pimenta / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T17:37:14Z (GMT). No. of bitstreams: 1
Giannini_Marcelo_M.pdf: 3112723 bytes, checksum: 3fe8542db1a2137c544a38a6e5acb21b (MD5)
Previous issue date: 1997 / Resumo: Os objetivos deste trabalho foram avaliar quantitativamente a resistência ao cisalhamento de quatro sistemas adesivos em dentina e observar o tipo de fratura ocorrida, decorrente do ensaio mecânico. Cento e oito corpos de prova foram preparados através de faces linguais/palatinas e vestibulares de pré-molares humanos, onde foram aplicados 4 diferentes sistemas adesivos associados ao compósito Z-100 (3M). Os corpos de prova foram armazenados em umidificador a temperatura de 37 '+ OU ¿' 1°C por uma semana e submetidos ao teste de cisalhamento em máquina universal de ensaios com velocidade de 0,5 mm/min. Após esse ensaio, os corpos de prova foram observados em lupa estereoscópica binocular, para se determinar os padrões de fraturas. Realizado o teste de análise de variância (p<0,05), não foram observadas diferenças estatisticamente significativas entre os valores obtidos, em MPa (média '+ OU ¿' DP), para os adesivos Prime & Bond 2.0 (24,38 '+ OU ¿' 9,05); Scotchbond MP-Plus (23,93 '+ OU ¿' 9,39); All Bond 2 (23,17 '+ OU ¿' 7,23) e One-Step (22,51 '+ OU ¿' 6,04). Na avaliação dos padrões de fraturas, notou-se um grande número de falhas adesivas e coesivas em dentina para todos os sistemas adesivos hidrófilos utilizados (47,2%). Valores semelhantes de resistência ao cisalhamento foram obtidos para os sistemas adesivos hidrófilos estudados. Fraturas coesivas em dentina e adesivas são características dessa corrente geração de adesivos dentinários / Abstract: The purpose of this study were to evaluate the shear bond strength (SBS) of four dentinal adhesive systems to dentin and to examine the failure at the dentin/restoration interface of fractured test specimes. From the lingual and facial surfaces of pre-molars, one hundred eigth samples were prepared and adhesives agents/composite were applied. The samples were stored in relative humidity at 37°C for one week prior to be subjected to a shear load at a crosshead speed of 0,5mm/min. Before this test, the specimes were observed in stereo-binocular microscope, to evaluate failure pattern. The mean '+ OU ¿' SD of the SBS in MPa were: Prime & Bond 2.0: 24,38 '+ OU ¿' 9,05; Scotchbond MP-Plus: 23,93 '+ OU ¿' 9,39; AlI Bond 2: 23,17 '+ OU ¿' 7,23 and One-Step: 22,51 '+ OU ¿' 6,04. There Were no statistically significant difference among mean values. The fractured test specimes were examined in a microscope and great number of failed cohesive in dentin were observed in alI groups investigated. Similar values of shear bond strength were obtained for the hydrophilic dentine bonding systems investigated. Cohesive failures in dentin are considered as a property of current dentin adhesives / Mestrado / Dentística / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289733
Date28 August 1997
CreatorsGiannini, Marcelo, 1969-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Pimenta, Luiz Andre Freire, 1965-, Martins, Luís Roberto Marcondes, 1960-, Goes, Mario Fernando de, Mauro, Silvio Jose
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format104p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0168 seconds