Return to search

Estudo do deslocamento dental linear em proteses totais processadas em diferentes ciclos de polimerização e tempos pós-prensagem / Study of the tooth movement in complete denturees processed by different polymerazation cyclews and post-pressing times

Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-11T16:30:52Z (GMT). No. of bitstreams: 1
Negreiros_WagnerAraujode_D.pdf: 1008776 bytes, checksum: c1f49fe9b1212453aa201116e5fe45db (MD5)
Previous issue date: 2008 / Resumo: Este trabalho verificou a movimentação de dentes em próteses totais confeccionadas a partir de diferentes ciclos de polimerização e tempos pós-prensagem. Foram confeccionadas 40 próteses totais superiores com as resinas acrílicas Clássico, QC-20 e Onda-Cryl, as quais foram distribuídas por sorteio em 8 grupos (n=5) de acordo com os ciclos de polimerização (longo em banho de água aquecida (grupo-controle), curto em água em ebulição e por energia de microondas) e tempos pós-prensagem (imediato e 6 horas). A montagem dos dentes foi realizada em articulador semi-ajustável, tendo como referência um modelo inferior dentado. Pinos referenciais metálicos foram posicionados na borda incisal dos incisivos centrais, na cúspide vestibular dos primeiros pré-molares e cúspide mésio-vestibular dos segundos molares. As distâncias transversais PMD-PME (pré-molar direito a pré-molar esquerdo) e MD-ME (molar direito a molar esquerdo) e ântero-posteriores ID-MD (incisivo direito a molar direito) e IE-ME (incisivo esquerdo e molar esquerdo) foram mensuradas antes e após o processamento, utilizando microscópio comparador (Olympus Optical Co., Tokyo, Japan), com precisão de 0,0005mm. As resinas acrílicas Clássico e QC-20 foram proporcionadas e manipuladas de acordo com as instruções dos fabricantes e submetidas aos ciclos de polimerização em água a 74ºC por 9 horas e em água em ebulição por 20 minutos, respectivamente. A resina Onda-Cryl foi submetida à polimerização por energia de microondas no ciclo 3 minutos a 35%, 4 minutos a 0% e 3 minutos a 65% da potência máxima do forno de microondas. Os dados coletados foram submetidos à análise de variância e as médias foram comparadas pelo teste de Tukey em nível de 5% de significância. Todas as distâncias mostraram movimentação dental; entretanto, esta não foi estatisticamente significante (5%) antes e após a polimerização para todos os ciclos de polimerização analisados. O ciclo de polimerização por microondas foi comparável estatisticamente ao ciclo convencional em banho de água aquecida (grupo controle) em relação à magnitude da movimentação dental. O tempo pós-prensagem 6 horas não mostrou vantagens em reduzir a magnitude do deslocamento dental em relação à polimerização imediata, na maioria das distâncias avaliadas. Concluiu-se que as alterações não foram similares, mostrando influência das resinas, tempo pós-prensagem e distância entre dentes / Abstract: This study verified the tooth movement in maxillary complete dentures submitted to different polymerization cycles and post-pressing times. Forty maxillary complete dentures fabricated with Classico, QC-20, and Onda-Cryl acrylic resins, were randomly assigned into 8 groups (n=5) according to the polymerization cycles (long cycle in water bath (control-group), fast cycle in boiling water, and microwave cycle) and the post-pressing time (immediate and after 6 hours). The wax pattern was made using a semi-adjustable articulator having a mandibular dentate cast as a reference. Metallic referential pins were placed on the incisal border of the central incisors, vestibular cusp of the first premolars, and the mesio-vestibular cusp of the second molars. The PMD-PME (right premolar to left premolar), MD-ME (right molar to left molar) transversal distances and RI-RM (right incisor to right molar) and LI-LM (left incisor to left molar) anteroposterior distances were measured before and after the complete dentures processing with a linear optical microscope (Olympus Optical Co., Tokyo, Japan) with an accuracy of 0.0005mm. All acrylic resins were proportioned and manipulated following the manufacturer¿s directions. Classico and QC-20 acrylic resins were submitted to the conventional water bath curing at 74ºC for 9 hours or to boiling water curing for 20 minutes respectively. Onda-Cryl acrylic resin was processed by microwave energy cycle for 3 minutes at 35%, 4 minutes at 0%, and 3 minutes at 65% power of the microwave oven. Collected data were submitted to the ANOVA and Tukey test at 5% of significance. All distances showed tooth movement; however, that was not statistically significant (5%) before and after processing for all polymerization cycles analyzed. The microwave polymerization cycle was statisticaly comparable with the conventional one in water bath (control group) considering the magnitude of tooth movement. The 6-hour post-pressing had no advantage in reducing the magnitude of tooth movement in relation to the immediate polymerization for most of the distances evaluated. It was concluded that the changes were not similar being influenced by the polymerization cycles, post-pressing time, and distance among teeth / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288558
Date18 August 2008
CreatorsNegreiros, Wagner Araujo de
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Consani, Rafael Leonardo Xediek, 1974-, Mendes, Wilson Batista, Mesquita, Marcelo Ferraz, Henriques, Guilherme Elias Pessanha, Kimpara, Estevão Tomitsu
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format53f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.1147 seconds