Return to search

Alteração dimensional da base de protese total superior e inferior, sob influencia da inclusão em mufla dupla / Dimensional change of the maxillary and mandibular denture base under influence of double flask

Orientador: Rafael Leonardo Xediek Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T13:00:28Z (GMT). No. of bitstreams: 1
Zampieri_MarinaldoHenrique_M.pdf: 729614 bytes, checksum: 67cd861fbbbca6e4ac88c4d28cbc4975 (MD5)
Previous issue date: 2008 / Resumo: O propósito deste trabalho foi estudar o efeito de muflas metálicas (convencional e mufla dupla experimental SR) e do tempo pós-prensagem (imediato e 6 horas) no nível de adaptação de bases de prótese total superior e inferior confeccionadas com resina acrílica Clássico ativada termicamente. Foramconfeccionados 80 conjuntos modelo de gesso-base de cera distribuídos aleatoriamente em 6 grupos (n=10), de acordo com o tipo de mufla metálica e do tempo pós-prensagem. A resina acrílica foi proporcionada e manipulada de acordo com as instruções do fabricante e prensada na fase plástica com carga inicial de 850 kgf e final de 1.250 kgf em prensa hidráulica de bancada. As bases foram polimerizadas em ciclo de água a 74°C por 9 horas. Depois do esfriamento das muflas até atingir a temperatura ambiente, as bases foram desincluídas, acabadas, fixadas nos respectivos modelos de gesso com adesivo à base de cianoacrilato e seccionados em três secções, correspondentes a distal de caninos (A), mesial de primeiros molares(B) e região palatina posterior(C). Em cada conjunto, o desajuste entre o modelo de gesso e a base de resina foi verificado nos seguintes pontos referenciais: 1- base superior: fundo do sulco vestibular direito e esquerdo, crista do rebordo alveolar direita e esquerda e linha mediana palatina; 2- inferior: fundo do sulco vestibular esquerdo e direito, crista do rebordo alveolar direita e esquerda, e fundo de sulco lingual direito e esquerdo. O desajuste foi verificado com microscópio comparador linear Olympus, com precisão de 0,0005mm. Os dados coletados foram submetidos à análise de variância e ao teste de Tukey (5%). Os resultados mostraram que houve diferença estatística significante entre as secções, onde A apresentou o melhor resultado, C o pior resultado e B demonstrou valor intermediário, para as bases superior e inferior. Na base de prótese superior, os tempos pós-prensagem em cada tipo de região e tipo de mufla mostraram diferença estatística, exceto na região A, para a mufla simples. Na comparação entre tipos de mufla para cada região no tempo imediato houve diferença estatística significante para todas as regiões. No tempo pós-prensagem de 6 horas não houve diferença estatística em todas as comparações. Entre os tipos de região para cada tempo pósprensagem da base inferior, o tempo imediato demonstrou diferença estatística em todas as regiões, quando o tipo de mufla foi comparado. O tempo de espera de 6 horas não mostrou diferença estatística entre as regiões e tipos de muflas / Abstract: The purpose of this work was to study the use of flask closure (conventional metallic flask closure nº5,5 and double SR flask closure.), regarding the adaptation of the prothesis'base (immediate and after six hours) in the upper total prothesis base and also the inferior total prothesis base adaptation. Both prothesis were made of acrylic resin activated by temperature (Classic®). 80 gypsum models were manufactured with wax base randomly distributed in 8 groups (n=10), according to the type of metallic flask closure used and the time that the prothesis remained under
pressure (immediate or after six hours). The resin was proportionate and manipulated according to the manufacturer instructions and it was put under pressure in the plastic phase, starting with 850 Kgf until 1250 Kgf utilizing the hydraulic press of workbench. The bases were manufactured and polymerized in water cycle at 74°C for 9 hours. After they reached room temperature, the bases were removed, finished, and replaced in its respective models using cianocrilato adhesive on the base. The models were divided into three sections, corresponding to distal of canines, mesial of first molars and posterior palate region. In each model, the superior and lower maladjustment between the gypsum model and the resin base was verified in the reference points mention above; Superior model: bottom of vestibular sulcus (right and left sides), alveolar crest (right and left sides) and average line of the palate. Lower model: bottom of vestibular sulcus (right and left sides), crest of the edge alveolar crest (right and left sides) and bottom of lingual sulcus (right and left sides). In each section, the maladjustment between the model and resin base was verified with an Olympus comparative linear microscope, with 0,0005mm accuracy. The data were collected and submitted to analysis of variance and to the test of Tukey (5%). The test results demonstrated a significant statistical difference between the sections, where section A showed the best result, C the worst, and B showed an intermediate value, for the lower and upper bases of the prothesis. In the base of the upper prosthesis, the time that the material was under pressure in each region and type of flask closure showed statistical difference, except in region A, for the simple flask closure. In the comparison between types of flask closure for each region in the immediate time showed significant statistical difference for all the regions. There was no statistical difference during the time the
material was under pressure (6 hours) for all comparisons. When the types of flask closure were compared regarding region types for each time the lower base was under pressure, the immediate time showed statistical difference in all the regions. There was no statistical difference between the regions and types of flask closure after a period of six hours / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288559
Date20 February 2008
CreatorsZampieri, Marinaldo Henrique
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Consani, Rafael Leonardo Xediek, 1974-, Tanji, Mauricio, Mesquita, Marcelo Ferraz
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format68p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0247 seconds