Return to search

Estudo comparativo entre o metodo tradicional de anestesia, seringa carpule, e um novo sistema de injeção anestesica

Orientador: Jose Ranali, Maria Cristina Volpato / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T01:29:16Z (GMT). No. of bitstreams: 1
Correa_ElisabeteMiriamdeCarvalho_M.pdf: 3055879 bytes, checksum: 74b204d21975c91c13e4180a32cc77b6 (MD5)
Previous issue date: 1997 / Resumo: O uso da menor dose possível de anestésico local para obtenção de uma anestesia eficaz sempre foi uma preocupação na anestesia odontológica, especialmente com relação a determinados grupos de pacientes (idosos, crianças, gestantes, cardiopatas etc). Observações prévias com o uso do Control Inject, um novo sistema de aplicação anestésica que controla eletronicamente a dosagem e a velocidade de administração da droga, sugeriram a possibilidade de obtenção de anestesia adequada, com um menor volume que o normalmente utilizado e maior conforto para o paciente. Sendo assim, o objetivo deste estudo foi comparar a administração dos anestésicos locais pelo método tradicional de anestesia, seringa carpule, com o sistema Control Inject. Para tal, foi realizado um estudo clínico, duplo cego, estudo cruzado, com 23 voluntários, os quais receberam anestesias infiltrativas pelos dois métodos de aplicação anestésica. Os parâmetros avaliados foram latência, profundidade da anestesia, duração do efeito anestésico e grau de desconforto experimentado durante o procedimento anestésico. A análise dos resultados (testes não- paramétricos de Friedman e de Wi1coxon) revelou não haver diferenças estatisticamente significantes entre os métodos testados (p > 0,05) / Abstract: The use of least possible dose of local anesthetic for obtaining an effective anesthesia, specially with some groups of patients (elderlies, children, pregnants, cardiac patients e~c) was always a matter of concem in Odontology. Previous observations about the use of Control Inject, a new injection sistem of local anesthetics that controls electronicaly the doses and the speed of administration of the drug suggested the possibility of obtaining a suitable anesthesia using a less volume that the generaly used and greater comfort for the patient. The purpose of this study was to compare the injection of local anesthetics
by the tradicional method, carpule syringe, with the Control Inject sistem. It was made a clinical study, double blind, cross over, with the participation of 23 volunteers, who received infiltration anesthesias by with both anesthetics methods. The parameters evaluated were latency period, depth and duration of anesthesia and degree of discomfort experienced during the anesthetic solution deposition. The statistical analysis (Friedman's and Wilcoxon's no parametric tests) showed no significant differences between the tested methods (p >0.05) / Mestrado / Farmacologia / Mestre em Ciências

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289406
Date18 June 1997
CreatorsCorrea, Elisabete Miriam de Carvalho
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Volpato, Maria Cristina, 1962-, Ranali, José, 1949-, Groppo, Francisco Carlos, Rocha, Rodney Garcia
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format65f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0265 seconds