Return to search

Avaliação da pressão intraocular, pressão arterial e diâmetro pupilar em coelhos (Oryctolagus cuniculus) submetidos ao bloqueio retrobulbar com diferentes protocolos anestésicos locais

Submitted by Emanoel Martins Filho (emanoelfilho@ufba.br) on 2016-09-12T18:02:51Z
No. of bitstreams: 1
RenataMoncao.pdf: 3406316 bytes, checksum: d4633de60b23d619f3d881549f59297f (MD5) / Approved for entry into archive by Patricia Barroso (pbarroso@ufba.br) on 2016-09-13T20:33:37Z (GMT) No. of bitstreams: 1
RenataMoncao.pdf: 3406316 bytes, checksum: d4633de60b23d619f3d881549f59297f (MD5) / Made available in DSpace on 2016-09-13T20:33:37Z (GMT). No. of bitstreams: 1
RenataMoncao.pdf: 3406316 bytes, checksum: d4633de60b23d619f3d881549f59297f (MD5) / O objetivo deste estudo foi buscar novos protocolos de anestesia loco regional para procedimentos oftálmicos que proporcionem segurança e manutenção das funções vitais, além de manter a pressão intraocular estável, com centralização do bulbo do olho e acinesia palpebral. Foram utilizados 20 coelhos da raça nova Zelândia para realização de quatro protocolos de anestesia local através do bloqueio retrobulbar com lidocaína 2% com vasoconstritor, lidocaína 2% sem vasoconstritos associada ao tramadol, ropivacaína 1% e bupivacaína 0,5%, cada animal recebeu o volume anestésico de 1ml. Todos os protocolos anestésicos utilizados promoveram acinesia palpebral e centralização do bulbo do olho durante todo o período de avaliação. A realização do bloqueio retrobulbar com os protocolos anestésicos propostos demonstrou ser factível e segura quanto à manutenção da pressão intraocular, pressão arterial invasiva e diâmetro pupilar e pode ser utilizada para realização de cirurgias intraoculares, respeitando-se o tempo de ação de cada anestésico. Todos os anestésicos demonstraram excelente qualidade de bloqueio, porém a bupivacaína foi o anestésico que proporcionou o maior diâmetro pupilar comparativamente aos demais fármacos testados. / The aim of this study was to evaluate four protocols of loco regional anesthesia for ophthalmic procedures that could provide safety and life support, in addition to maintain intraocular pressure stable, with eye centralization and eyelid akinesia. 20 New Zealand rabbits were used to perform local anesthesia by retrobulbar block with four protocols: 2% lidocaine with epinephrine, 2% lidocaine without epinephrine associated with tramadol, 1% ropivacaine and bupivacaine 0.5 %. Each animal received an anesthetic volume of 1ml. All anesthetic protocols used promoted eyelid akinesia and centralization of the eye during the assessment period. The retrobulbar block with the proposed anesthetic protocols proved to be feasible and safe for the maintenance of intraocular pressure, invasive blood pressure and pupillary diameter and can be used on intraocular surgeries, respecting the time of action of each anesthetic. All protocols showed an excellent blockage action, but bupivacaine promoted the highest pupil diameter compared to the other drugs tested.

Identiferoai:union.ndltd.org:IBICT/oai:192.168.11:11:ri/20369
Date21 January 2014
CreatorsSilva, Renata Maria Monção da
ContributorsOriá, Arianne Pontes, Castro, Vanessa Bastos de, Barbosa, Vivian Fernanda, Peixoto, Tiago da Cunha, Costa Neto, João Moreira da, Oriá, Arianne Pontes
PublisherUniversidade Federal da Bahia, Programa de Pós Graduação em Ciência Animal nos Trópicos, UFBA, brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFBA, instname:Universidade Federal da Bahia, instacron:UFBA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds