Submitted by Fatima Fonseca (fatima.fonseca@sibi.ufrj.br) on 2017-08-31T17:45:40Z
No. of bitstreams: 1
144555.pdf: 4167700 bytes, checksum: 809b19c17a9ff58429b4c2c4f597e1e1 (MD5) / Made available in DSpace on 2017-08-31T17:45:40Z (GMT). No. of bitstreams: 1
144555.pdf: 4167700 bytes, checksum: 809b19c17a9ff58429b4c2c4f597e1e1 (MD5)
Previous issue date: 1976-11 / O presente trabalho visa a título de contribuição ao estudo de Problemas de Construção de Aterros sobre depósitos naturais de argila mole, apresentar e discutir características de adensamento com drenagem na direção vertical e radial e a influência nestas características do método de instalação de dreno vertical de areia. O estudo foi feito através de ensaios de laboratório. Uma revisão da bibliografia consultada sobre drenos verticais de areia á apresentada. Resultados de ensaios de adensamento oedométrico com drenagem vertical e radial (interna e externa) e ensaios de adensarnento triaxial radial interno são apresentados. A influência de condições de fronteiras indesejáveis no ensaio oedométrico com drenagem radial interna é mostrada. O efeito do amolgamento em algumas características de adensamento foi examinado. Procurou-se conhecer o coeficiente de compressão secundária, Cα, da argila em estudo e o efeito em Cα da instalação de dreno de areia. Tentou-se verificar a influência, na resistência ao cisalhamento não drenado, da instalação de drenos de areia - tubo com ponta fechada, através de ensaios de palheta em laboratório. / This dissertation, as a contribution to the study of problems in construction of embankments on natural soft clay deposits, presents and discusses laboratory vertical and radial drainage consolidation charactheristics with the influence of communly used sand drain installation methods. A partial bibliography review on vertical sand drains is presented. Results of vertical and radial (internal and external drainage) oedometer consolidation and triaxial consolidation tests with radial internal drainage are presented. The influence of undesirable boundary conditions in oedometer tests with radial internal drainage is shown. Disturbance effect on some consolidation charactheristics has been examined. The coefficient of secondary compression (Cα) and the effect on it due to sand drain installation rnethod has been tentatively evaluated. The influence on undrained shear strength due the installation of vertical sand drains by the closed madrel method has also been tentatively evaluated.
Identifer | oai:union.ndltd.org:IBICT/oai:pantheon.ufrj.br:11422/2757 |
Date | 11 1900 |
Creators | Coutinho, Roberto Quental |
Contributors | Lacerda, Willy Alvarenga |
Publisher | Universidade Federal do Rio de Janeiro, Programa de Pós-Graduação em Engenharia Civil, UFRJ, Brasil, Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa em Engenharia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFRJ, instname:Universidade Federal do Rio de Janeiro, instacron:UFRJ |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0033 seconds