Return to search

Estudo de mistura de solos para impermeabilização eficiente de camada de base de aterros sanitários.

Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-13T20:50:04Z
No. of bitstreams: 1
THIAGO FERNANDES DA SILVA – DISSERTAÇÃO (PPGECA) 2017.pdf: 2028190 bytes, checksum: 54afe9db3986c5fc9afbadce4f2e7f1c (MD5) / Made available in DSpace on 2018-04-13T20:50:04Z (GMT). No. of bitstreams: 1
THIAGO FERNANDES DA SILVA – DISSERTAÇÃO (PPGECA) 2017.pdf: 2028190 bytes, checksum: 54afe9db3986c5fc9afbadce4f2e7f1c (MD5)
Previous issue date: 2017-08 / Capes / Os aterros sanitários representam a alternativa mais utilizada em todo mundo para disposição ambientalmente adequada de Resíduos Sólidos Urbanos (RSU), sendo sua camada de base (liners) um dos principais componentes. A ausência de cuidados com essas camadas podem gerar danos ambientais imensuráveis, como a infiltração de lixiviado para corpos hídricos superficiais e lençóis freáticos próximos, além de contaminação do solo. O coeficiente de permeabilidade à água é a principal variável utilizada para verificar a eficiência das liners. Dentro desse contexto, este trabalho tem como objetivo obter uma composição adequada de solos para camada de base de aterro sanitário atendendo às exigências de permeabilidade à água de acordo com padrões nacionais e internacionais. O campo experimental para esta pesquisa foi o aterro sanitário no município de Campina Grande – PB, que utiliza uma composição entre dois tipos de solos para camada em estudo. Inicialmente, foram realizadas caracterizações geotécnicas, físico-químicas e mineralógicas desses dois tipos de solos, sendo denominados de Solo 1 aquele obtido na área do empreendimento e Solo 2 obtidos em jazidas no município de Boa Vista – PB. Aplicou-se a técnica do planejamento fatorial na qual foram avaliadas as variáveis da mistura: energia de compactação, umidade e porcentagem de Solo 2. Com isso, foi possível otimizar o processo de interação entre as variáveis de controle e reduzir o número de ensaios realizados. Foram utilizados os delineamentos composto central (modelo plano) e composto central rotacional (modelo com curvatura). Para determinação da permeabilidade à água, foi selecionado o modelo que apresentou melhor ajuste, de acordo com o Critério de Akaike (AiC), a Soma dos Quadrados dos Resíduos (SQR) e o Coeficiente de Determinação (R²). O valor de K admissível foi determinado de acordo exigências da Companhia Ambiental do Estado de São Paulo (CETESB), da Associação Brasileira de Normas Técnicas (ABNT) e da Agência de Proteção Ambiental Americana (EPA). O Solo 1 é uma areia mal graduada argilosa e o Solo 2 é um material com presença argilominerais esmectíticos, apresentando Índice de Plasticidade (IP) de 124%. O modelo que apresentou melhor ajuste foi o plano. Foram obtidos valores de K: energia de compactação de 0,476 MN.m/m³, umidade de 8,285% e porcentagem de Solo 2 de 29,685%. Como o Solo 1 apresenta percentual granulométrico de areia elevado (89,67%), a porcentagem de Solo 2 obtida para a mistura é necessária para preencher os interstícios do Solo 1, com umidade suficiente para lubrificar as partículas e energia de compactação suficiente para fornecer a acomodação destas partículas. Com isso, foi possível obter uma camada de base adequada para o aterro sanitário em estudo atendendo às exigências de permeabilidade à água de acordo com padrões nacionais e internacionais, permitindo que este estudo seja aplicado também a aterros com características semelhantes, podendo ainda, com esses resultados, ser sugerido o redirecionamento na operação destes aterros. / Landfills represent the most widely used worldwide alternative for the environmentally sound disposal of Urban Solid Waste (RSU), with its liners being one of the main components. Lack of care with these layers can generate immeasurable environmental damage, such as leachate infiltration to nearby surface water bodies and groundwater, in addition to soil contamination. The water permeability coefficient is the main variable used to verify liners efficiency. Within this context, this work aims to obtain an adequate composition of soils for the base layer of landfill, meeting the water permeability requirements according to national and international standards. The experimental field for this research was the sanitary landfill in the city of Campina Grande - PB, which uses a composition between two types of soils for the study layer. Initially, geotechnical, physical-chemical and mineralogical characterizations of these two types of soils were carried out, being called of Soil 1 that obtained in the area of the project and Soil 2 obtained in deposits in the municipality of Boa Vista - PB. The technique of factorial planning was applied in which the variables of the mixture were evaluated: energy of compaction, humidity and percentage of Soil 2. With this, it was possible to optimize the interaction process between the control variables and to reduce the number of tests performed . The central composite (plane model) and rotational central composite (curvature model) were used. To determine the permeability to water, the model that presented the best fit was selected according to the Akaike criterion (AiC), the sum of squares of the residuals (SQR) and the coefficient of determination (R²). The admissible K value was determined in accordance with requirements of the Environmental Protection Agency of the State of São Paulo (CETESB), the Brazilian Association of Technical Standards (ABNT) and the American Environmental Protection Agency (EPA). Soil 1 is a clayey poorly graded sand and Soil 2 is a material with smectite clayey minerals, with a Plasticity Index (PI) of 124%. The model that presented the best fit was the plan. K values were obtained: compaction energy of 0.476 MN.m / m³, humidity of 8.285% and Soil 2 percentage of 29.685%. Since Soil 1 has a high sand particle size (89.67%), the percentage of Soil 2 obtained for the mixture is required to fill the interstices of Soil 1, with sufficient moisture to lubricate the particles and sufficient compaction energy to provide the accommodation of these particles. With this, it was possible to obtain a suitable base layer for the sanitary landfill under study, meeting the requirements of water permeability according to national and international standards, allowing this study to be applied also to landfills with similar characteristics. redirecting the operation of these landfills.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:riufcg/390
Date13 April 2018
CreatorsSILVA, Thiago Fernandes da.
ContributorsMONTEIRO, Veruschka Escarião Dessoles., PAIVA, William de., MELO, Márcio Camargo de., SANTOS, Gerson Marques dos., PEREIRA, Ronildo Alcântara.
PublisherUniversidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL, UFCG, Brasil, Centro de Tecnologia e Recursos Naturais - CTRN
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0029 seconds