Desenvolvimento de procedimentos analíticos limpos e com alta sensibilidade para a determinação de espécies de interesse ambiental / Development of clean analytical procedures with high sensitivity for determination of species of environmental interest

Procedimentos analíticos limpos e com alta sensibilidade foram desenvolvidos para a determinação de espécies de interesse ambiental (carbaril, sulfato e cloro livre). Os procedimentos foram baseados no acoplamento de sistemas de análises em fluxo com microbombas solenoides à espectrofotometria com longo caminho óptico ou em procedimentos de extração em ponto nuvem, visando a concentração das espécies de interesse sem o emprego de solventes tóxicos. A determinação de carbaril em águas naturais foi baseada em uma dupla extração em ponto nuvem: uma etapa de clean-up para a remoção de substâncias orgânicas interferentes e outra de pré-concentração do indofenol formado na reação com a forma oxidada do p-aminofenol. Resposta linear foi observada entre 10 e 500 µg L-1, com absortividade molar aparente estimada em 4,6x105 L mol-1 cm-1. O limite de detecção foi estimado em 7 µg L-1 e coeficiente de variação em 3,4% (n = 8). Recuperações entre 91 e 99% foram estimadas para adições de carbaril em amostras de águas naturais. Uma cela simples e de baixo custo com 30 cm de caminho óptico foi construída para medidas espectrofotométricas. A cela apresenta características desejáveis como baixa atenuação do feixe de radiação e volume interno (75 µL) comparável a de uma cela convencional. O desempenho da cela foi avaliado na determinação de fosfato utilizando o método azul de molibdênio com resposta linear obtida entre 0,05 e 0,8 mg L-1 de fosfato (r = 0,999). O aumento na sensibilidade (30,4 vezes) em comparação com o obtido com uma cela de fluxo convencional de 1 cm está de acordo com o estimado pela lei de Lambert-Beer. A formação do indofenol foi também explorada para a determinação de carbaril no procedimento em fluxo com celas de 30 e 100 cm. Respostas lineares; limite de detecção e coeficiente de variação foram estimados entre 50 - 750 e 5 - 200 µg L-1; 4,0 e 1,7 µg L-1 e 2,3 e 0,7%, respectivamente, para as celas de 30 e 100 cm. O procedimento proposto foi seletivo para a determinação de carbaril, sem interferências de outros pesticidas carbamatos. O resíduo gerado foi tratado com persulfato de potássio e irradiação ultravioleta, com redução de 94% do carbono orgânico total, não sendo o resíduo degradado considerado tóxico, frente às bactérias Vibrio-fischeri. A determinação de sulfato foi baseada em medidas turbidimétricas com cela de fluxo de 1 cm, com resposta linear observada entre 20 - 200 mg L-1. Deriva de linha base não foi observada em função do fluxo pulsado gerado pelas microbombas solenoides. O limite de detecção e o coeficiente de variação (n = 20) foram estimados em 3 mg L-1 e 2,4%, respectivamente, com frequência de amostragem de 33 determinações por hora. Para aumentar a sensibilidade, uma cela de fluxo de 100 cm foi empregada e deriva de linha base foi evitada utilizando uma etapa de limpeza periódica com EDTA em meio alcalino. Resposta linear foi observada entre 7 - 16 mg L-1 com limite de detecção de 150 µg L-1 e coeficiente de variação de 3,0% (n = 20). A frequência de amostragem foi estimada em 25 determinações por hora. Resultados obtidos para amostras de águas naturais e de chuva foram concordantes a nível de confiança de 95% com o procedimento turbidimétrico em batelada. A determinação de cloro livre em águas naturais e de torneira foi baseada na reação com N,N-dietil-p-fenilenodiamina, com resposta linear entre 5 e 100 µg L-1 de hipoclorito e limite de detecção e coeficiente de variação estimados em 0,23 µg L-1 e 3,4%, respectivamente. A frequência de amostragem foi estimada em 58 determinações por hora. / Clean analytical procedures with high sensitivity for the determination of species of environmental interest (carbaryl, sulphate and chlorine) were developed. Flow systems with solenoid micropumps were coupled to long optical pathlength spectrophotometry or cloud point extraction procedures, aiming the concentration of species for determination without employing toxic solvents. Carbaryl determination in natural waters was based on a double cloud point extraction: a clean-up step for removal of interfering organic species and pre-concentration of the indophenol blue, formed in the reaction with the oxidized of p-aminophenol. Linear response was observed between 10 and 50 µg L-1, with apparent molar absortivity estimated as 4.6x105 L mol-1 cm-1. Detection limit was estimated as 7 mg L-1 and the coefficient of variation as 3.4% (n = 8). Recoveries between 91 and 99% were obtained for carbaryl spiked to natural waters. A simple and low cost flow cell with 30 cm optical path was constructed for spectrophotometric measurements. The cell shows desirable characteristics such as reduced attenuation of the radiation beam and internal volume (75 µL) comparable to conventional flow cells. The performance was evaluated by phosphate determination by the molibdenium blue method, with linear response between 0.05 and 0.8 mg L-1 of phosphate (r = 0.999). The increase in sensitivity (30.4 fold) in comparison to the obtained with a conventional 1 cm optical path flow cell agreed to theoretical value estimated by the Lambert-Beer law. The determination of carbaryl was also carried out in a flow system coupled to 30 and 100 cm optical path flow cells, also exploiting the formation of indophenol compound. Linear responses, detection limits and coefficients of variation were 50 - 750 and 5 - 200 µg L-1;4.0 and 1.7 µg L-1 and 2.3 and 0.7%, respectively, for 30 and 100 cm cells. The proposed procedure was selective for the determination of carbaryl, without interferences of other carbamate pesticides. The waste of the analytical procedure was treated with potassium persulphate and ultraviolet irradiation, with decrease of 94% of total organic carbon. The residue after treatment was not toxic for Vibrio-fischeri bacteria. Sulphate determination was based on turbidimetric measurements with 1-cm flow cell, with linear response between 20 and 200 mg L-1. Baseline drift was avoided in view of the pulsed flow related to the solenoid micropumps. The detection limit and the coefficient of variation were estimated as 3 mg L-11 and 2.4%, respectively, for a sampling rate of 33 determinations per hour. Aiming the increase in sensitivity, a 100 cm optical path flow cell was employed and baseline drift was avoided with a washing, step employing EDTA in alkaline medium. Linear response was observed between 7 - 16 mg L-1, with a detection limit of 150 µg L-1, coefficient of variation of 3.0% (n = 20) and sampling rate of 25 determinations per hour. Results obtained natural and rain for water samples agreed at 95% confidence level with the batch turbidimetric procedure. The determination of free chlorine in natural and tap waters was based on the reaction with N,N-diethyl-p-phenylenediamine, with linear response between 5 and 100 µg L-1, and detection limit and coefficient of variation estimated as 0.23 µg L-1 and 3.4%, respectively. Sampling rate was estimated as 58 determinations per hour.

Identiferoai:union.ndltd.org:usp.br/oai:teses.usp.br:tde-25062009-150929
Date28 May 2009
CreatorsMelchert, Wanessa Roberto
ContributorsRocha, Fábio Rodrigo Piovezani
PublisherBiblioteca Digitais de Teses e Dissertações da USP
Source SetsUniversidade de São Paulo
LanguagePortuguese
Detected LanguageEnglish
TypeTese de Doutorado
Formatapplication/pdf
RightsLiberar o conteúdo para acesso público.

Page generated in 0.003 seconds