Bearing currents are not all the same. Under certain circumstances and special use cases classic bearing insulations are not sufficient anymore to prevent bearing currents due to the operation of frequency converters. Additional corrective measures have to be implemented to reduce the source of bearing currents the common mode current. The usage of nanocrystalline tape wound
cores shows high effectiveness. As part of a big field study with more than 50 large drive trains in the primary industry, the damaging mechanics of bearing currents are examined under real conditions. Of exceptional high interest is the influence of disturbances which can hardly be simulated in the laboratory. Additional to the shielded motor cable parallel installed functional potential equalization cables applied multiple times have almost no effect in regard to reducing the bearing current. With an optimal installed functional potential equalization system more than 95 percent of the common mode current can flow back through the motor cable shield to the converter. The disturbance impact in the field can influence the voltage over the bearing that breakthroughs are favored but also reduced.
Identifer | oai:union.ndltd.org:DRESDEN/oai:qucosa:de:qucosa:38455 |
Date | 28 February 2020 |
Creators | Tröger, Sven, Kröger, Matthias |
Contributors | TU Bergakademie Freiberg |
Publisher | TU Bergakademie Freiberg |
Source Sets | Hochschulschriftenserver (HSSS) der SLUB Dresden |
Language | English |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, doc-type:conferenceObject, info:eu-repo/semantics/conferenceObject, doc-type:Text |
Rights | info:eu-repo/semantics/openAccess |
Relation | 978-3-86012-610-3, urn:nbn:de:bsz:105-qucosa2-384478, qucosa:38447 |
Page generated in 0.0024 seconds